Effect of critical Mach number and flutter on maximum power loading of ducted fans
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Small turbofan engine design concepts were applied to military trainer airplanes to establish the potential for commonality between civil and military engines. Several trainer configurations were defined and studied. A ""best'' engine was defined for the trainer mission, and sensitivity analyses were performed to determine the effects on airplane size and efficiency of wing loading, power loading, configuration, aerodynamic quality, and engine quality. It is concluded that a small civil aircraft is applicable to military trainer airplanes. Aircraft designed with these engines are smaller, less costly, and more efficient than existing trainer aircraft.
Power supply voltage-regulator circuit speeds up response to sudden load changes. As load increases, additional feedback path is enabled. Path bypasses and provides faster loop response than normal feedback path. Steady-state instability due to faster loop response avoided by progressively disabling bypass loop and allowing normal feedback path to take over.
In December, 1986, a Center Director's Discretionary Fund (CDDF) proposal was granted to study power system control techniques in large space electrical power systems. Presented are the accomplishments in the area of power system control by power quality load management. In addition, information concerning the distortion problems in a 20 kHz ac power system is presented.
In a DC grid, constant power loads (CPLs) necessitate a large bus capacitor to prevent negative impedance instability. Some of the capacitance can be realized virtually through CPL control to reduce the bus capacitor size. Here, this paper analytically studies system stability with virtual capacitor control. We demonstrate that the effectiveness of virtual capacitor control is highly sensitive to the implementation of the derivative action required to emulate the capacitor. For the first time, we theoretically demonstrate that a virtual capacitor can stabilize the system without any physical bus capacitor, provided that a set of analytically derived conditions are met. However, this stabilization is not achievable in practice due to the influence of non-idealities. In an example system requiring a $14$ mF capacitor to stably support the CPL, we show that stability can be achieved through virtual capacitor control, using only a 2 mF physical capacitor to account for the switching ripple non-idealities. Hardware-in-the-loop tests verify the analysis.
Power and load priorty control concept for Brayton cycle power system providing speed control and field current control for alternator and load simulation which includes energy storage
The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.
The influx of non-linear power electronic loads into the distribution network has the potential to disrupt the existing distribution transformer operations. They were not designed to mediate the excessive heating losses generated from the harmonics. To have a good understanding of current standing challenges, a knowledge of the generation and load mix as well as the current harmonic estimations are essential for designing transformers and evaluating their performance. In this paper, we investigate a mixture of essential power electronic loads for a household designed in PSCAD/EMTdc and their potential impacts on transformer eddy current losses and derating using harmonic analysis. Our findings reveal that in the presence of high power electronic loads (especially third harmonics), increasing PV generation may worsen transformer degradation. However, with a low amount of power electronic loads, additional PV generation helps to reduce the harmonic content in the current and improve transformer performance.
Load driven by two motors continuously draws power from a varying source (solar cells) and steady auxiliary source (utility company). Power-factor controller apportions electrical load between two sources to maintain motor speed. This novel application of power-factor controller would regulate input of auxiliary energy to a solar-powered system in response to availability of Sunlight.
The example embodiments are directed to a system and method for forecasting load flexibility of a power grid. In one example, the method includes receiving temperature values associated with temperature set points of a plurality of loads that are included on a power grid, forecasting a flexibility of the plurality of loads using a polynomial-time mixed-integer non-linear programming (MINLP) optimization based on the received temperature values for the plurality of loads, and outputting information about the forecasted flexibility for display to a display device. The MINLP optimization performs the forecasting of the load flexibility on a fine-grained basis in comparison to conventional methods and is still fast enough that it can be computed in real-time.
The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.
Spacecraft are typically complex assemblies of interconnected systems and components that have highly time-varying thermal communications, and power requirements. It is essential that systems designers be able to assess the capability of the spacecraft to meet these requirements which should represent a realistic projection of demand for these resources once the vehicle is on-orbit. To accomplish the assessment from the power standpoint, a computer code called ECAPS has been developed at NASA Lewis Research Center that performs a load-driven analysis of a spacecraft power system given time-varying distributed loading and other mission data. This program is uniquely capable of synthesizing all of the changing spacecraft conditions into a single, seamless analysis for a complete mission. This paper presents example power load timelines with which numerous data are integrated to provide a realistic assessment of the load-following capabilities of the power system. Results of analyses show how well the power system can meet the time-varying power resource demand.
Dedicated experiments were performed on MAST Upgrade to study beam-ion losses caused by charge exchange (CX) with edge neutrals. The fuelling was switched from the high-field side to the low-field side mid-discharge. Direct measurements suggest a strong increase in the neutral density around the plasma and a decrease in the beam-ion density, which is qualitatively explained by CX losses. Measurements by a resistive bolometer have suggested particle bombardment during neutral beam injection, providing a unique opportunity to separate CX from other loss mechanisms. To verify and quantify CX losses, the orbit-following code ASCOT, which accounts both for CX neutralization and reionization, was used to simulate beam-particle power loads on the bolometer. Simulations reproduce measured bolometer power loads during high-field-side fuelling, verifying CX losses of approximately 10% of the off-axis beam power. Toroidally symmetric simulations overestimate power loads on the bolometer during low-field-side fuelling, which is explained by toroidal asymmetry in the neutral density distribution, as is demonstrated by toroidally asymmetric simulations. Results suggest significantly higher CX losses during low-field-side fuelling, up to about 50% of off-axis beam power.
A variety of methods has been devised for vibrational control of a structure using both passive and active controls. Presented in this paper is a relatively new method for vibration suppression, uniform damping control. This method consists of implementing a control law which tends to dampen each vibrational mode of the structure at the same desirable exponential rate. The unique aspects of this method are that the control law is not explicitly dependent on the structural stiffness, the control forces are directly proportional to the distribution of the structural mass, and the control law is natural and decentralized. The control law was applied to a flexible planar truss structure and the various aspects of implementation of the control law examined are: actuator/sensor number, placement, and the impact of the actuator/sensor number and placement on the necessary control 'power' requirements such as peak power loads, total power requirements, etc. Also examined are the effects of using a limited number of active members in terms of the vibrational performance when compared with the 'ideal' distributed control law.
The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.
This paper describes a dynamic load which is computer-controlled and has an increased bandwidth of more than 10 times that commercially available at the time the development of the project began. The load is 3 kW with a bandwidth of 35 kHz. The hardware and software are described, and the control circuitry is shown.
Here, this study presents theoretical formulations to evaluate the fundamental parameters and performance characteristics of a bottom-raised oscillating surge wave energy converter (OSWEC) device. Employing a flat plate assumption and potential flow formulation in elliptical coordinates, closed-form equations for the added mass, radiation damping, and excitation forces/torques in the relevant pitch-pitch and surge-pitch directions of motion are developed and used to calculate the system's response amplitude operator and the forces and moments acting on the foundation. The model is benchmarked against numerical simulations using WAMIT and WEC-Sim, showcasing excellent agreement. The sensitivity of plate thickness on the analytical hydrodynamic solutions is investigated over several thickness-to-width ratios ranging from 1:80 to 1:10. The results show that as the thickness of the benchmark OSWEC increases, the deviation of the analytical hydrodynamic coefficients from the numerical solutions grows from 3% to 25%. Differences in the excitation forces and torques, however, are contained within 12%. While the flat plate assumption is a limitation of the proposed analytical model, the error is within a reasonable margin for use in the design space exploration phase before a higher-fidelity (and thus more computationally expensive) model is employed. A parametric study demonstrates the ability of the analytical model to quickly sweep over a domain of OSWEC dimensions, illustrating the analytical model's utility in the early phases of design.
This paper describes a system to regulate the speed and power output of a Brayton Cycle Power System under varying load. A typical user load profile is applied and a simple load priority and parasitic load is used for system regulation. Power storage is provided by batteries with charge and discharge converters to demonstrate support capability. The breadboard system is tested with the Brayton Cycle Demonstrator at the National Aeronautics and Space Administration, Manned Space Craft Center, Houston, Texas.