Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid xenon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Anapole moment of neutrinos and radioactive sources near liquid xenon detectors

We show that placing a radioactive source such as 51 Cr near a liquid xenon detector may allow us to detect the contribution induced by the anapole moment to neutrino-electron scattering in the Standard Model (SM) at the 1 − 2⁢𝜎 level. Although the anapole moment of neutrinos induces a scattering rate with the same spectral shape as the neutral and charged current contributions, exposures of ∼ 60 ton × source run at XENONnT or XLZD may be enough to accumulate sufficient statistics for a detection. We also discuss a simple model where the anapole moment of neutrinos is enhanced or decreased with respect to the SM expectation, further demonstrating how a potential measurement of the anapole moment of neutrinos would allow us to constrain new physics.

dark matter direct detection↗

DIREXENO—an apparatus for measuring correlated scintillation signatures in liquid xenon

We present a detector apparatus, DIREXENO (DIREctional XENOn), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments; however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits spatial correlations such as super-radiance which manifests in temporal and spatial structure, depending on the interaction type. Such properties of scintillation light may open a new window for background rejection as well as directionality measurements. We present the apparatus' technical design and the concepts driving it. We demonstrate that for an energy deposition of ~2.5 keV (~7.5 keV) electron (nuclear) recoil the detector is sensitive to an anisotropy fraction of as little as ~ 20% of the total photons emitted over a solid angle of ~0.85 steradian or less. We show results from commissioning runs in which the detector operated with 17 PMTs for over 44 days in stable conditions. The time resolution for individual photons in different PMTs was measured to be ≲1.4 ns full-width at half-maximum

47 OTHER INSTRUMENTATION↗

Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below ∼3 keV nr where signals from dark matter particles of <10 GeV/c 2 masses are expected. The coherent elastic neutrino-nucleus scattering (CE ν NS) by solar 8 B neutrinos also results in a continuum of nuclear recoil events below 3.0 keV nr (99% of events), which further complicates low-mass dark matter searches in LXe experiments. In this paper, we describe a method to quantify the uncertainties of low-energy LXe responses using published calibration data, followed by case studies to evaluate the impact of yield uncertainties on 8 B searches and low-mass dark matter sensitivity in a typical ton-scale LXe experiment. We conclude that naively omitting yield uncertainties leads to overly optimistic limits by factor ∼2 for a 6 GeV WIMP mass. Future nuclear recoil light yield calibrations could allow experiments to recover this sensitivity and also improve the accuracy of solar 8 B flux measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing Advanced Charge Readout Techniques for nEXO and Future Liquid Xenon OVBB Detectors (Final Report)

This award supported the Yale group’s efforts on nEXO, which included the following: 1) Developed techniques for measuring the outgassing of materials into liquid xenon (LXe) and a model for predicting the electron lifetime in nEXO and future LXe TPCs 2) Work to develop the conceptual design for the nEXO Photon Detector subsystem and TPC subsystem interconnections 3) Developed simulation of charge and light propagation and readout in nEXO.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solar neutrino detection in liquid xenon detectors via charged-current scattering to excited states

We investigate the prospects for real-time detection of solar neutrinos via the charged-current neutrino-nucleus scattering process in liquid xenon time projection chambers. We use a nuclear shell model, benchmarked with experimental data, to calculate the cross sections for populating specific excited states of the cesium nuclei produced by neutrino capture on Xe 131 and Xe 136 . The shell model is further used to compute the decay schemes of the low-lying 1 + excited states of Cs 136 , for which there is sparse experimental data. We explore the possibility of tagging the characteristic deexcitation γ rays/conversion electrons using two techniques: spatial separation of their energy deposits using event topology and their time separation using delayed coincidence. The efficiencies in each case are evaluated within a range of realistic detector parameters. We find that the topological signatures are likely to be dominated by radon backgrounds, but that a delayed-coincidence signature from long-lived states predicted in Cs 136 may enable background-free detection of CNO neutrino interactions in next-generation experiments with smaller uncertainty than current measurements. We also estimate the sensitivity as a function of exposure for detecting the solar-temperature-induced line shift in Be 7 neutrino emission, which may provide a new test of solar models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Pushing the limits of pulse shape discrimination in a large liquid xenon detector

Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing tail fraction discriminator is optimized and achieves ER leakage as low as $$15\%$$ 15 % . For specific background processes such as $$^{124}$$ 124 Xe double electron capture, the leakage is reduced further to about $$5\%$$ 5 % . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Measurement of charge and light yields for 127 Xe L -shell electron captures in liquid xenon

Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using β -decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inner-shell electrons. Such events lead to emission of x rays and Auger electrons, resulting in higher electron-ion recombination and thus a more NR-like response than inferred from β -decay calibration. We present a cross-calibration of tritium β -decays and Xe 127 electron-capture decays (which produce inner-shell vacancies) in a small-scale LXe-TPC and give the most precise measurements to date of light and charge yields for the Xe 127 L -shell electron-capture in liquid xenon. We observe a 6.9 σ ( 9.2 σ ) discrepancy in the L -shell capture response relative to tritium β decays, measured at a drift field of 363 ± 14 V / cm ( 258 ± 13 V / cm ), when compared to simulations tuned to reproduce the correct β -decay response. In dark matter searches, use of a background model that neglects this effect leads to overcoverage (higher limits) for background-only multi-kiloton-year exposures, but at a level much less than the 1 - σ experiment-to-experiment variation of the 90% C.L. upper limit on the interaction rate of a 50 GeV / c 2 dark matter particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of dielectric breakdown in liquid xenon with XeBrA: The xenon breakdown apparatus

Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. Here, in this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved modeling of β electronic recoils in liquid xenon using LUX calibration data

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $\beta$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A next-generation liquid xenon observatory for dark matter and neutrino physics

The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for weakly interacting massive particles, while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of 125 Xe and 127 Xe , and double-electron-capture decays of 124 Xe , are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy 𝛽 decays and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1 keV M-shell, 5.2 keV L-shell, and 33.2 keV K-shell at drift fields of 193 and 96.5 V/cm. The LL double-electron-capture decay of 124 Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗