Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

Thermo-Fluid Modeling Framework for Supercomputer Digital Twins: Part 1, Demonstration at Exascale

A thermo-fluid modeling framework is being developed for ExaDigiT---an open-source framework for developing comprehensive digital twins of liquid-cooled supercomputers. The work is being conducted in two parts, and discussion is divided into two companion papers. The work documented in this paper focuses on the development of a cooling system library in Dymola for the Frontier supercomputer at Oak Ridge National Laboratory. The second part, outlined in a companion paper, focuses on a templating structure called Auto-CSM for easily creating model-agnostic, physics-based thermo-fluid cooling system models for liquid-cooled supercomputers using a text-based schema. The cooling model is being developed using primarily the open-source Transient Simulation Framework of Reconfigurable Models (TRANSFORM) library. The library follows the templating architecture developed within the TRANSFORM library for modeling subsystems. A full-system validation was performed to validate a very simple model that is integrated with the system controls, and the results are presented herein.

Kumar, Vineet↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EVSE Characterization

NextGen Profiles' EVSE characterization efforts explored performance variability in production EVSE through the use of EV emulation equipment and assessed how different operational conditions influence charging behavior. Data were collected at a frequency of 10 Hz from both the EV emulator and EVSE during each charge session and stored in a time-series database for further analysis. As part of the NextGen Profiles project, characterization of high-power EVSE was performed on both conductive and wireless charging infrastructure; however, only conductive charging data are currently included in this repository. This EVSE characterization was performed over a range of DC output currents and voltages, covering both nominal and off-nominal test conditions. This EVSE characterization dataset includes high-power charging data from two types of 350-kW-capable EVSE using liquid-cooled Combined Charging System-1 (CCS1, North American version) cables and connectors. To protect confidentiality, all EVSE metadata are anonymized, and the publicly released datasets are metered at 10-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVSE Characterization, A Next-Gen Profiles Project Report

As part of the U.S. DOE EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization was conducted over a wide range of DC output current and DC voltage charging for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2023 study conducted on electric vehicle supply equipment (EVSE) characterization by Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) include one 350 kW capable EVSE using a liquid-cooled combined charging system-1 (CCS-1, North American version) cable and connector and an ORNL-developed 100-kW polyphase wireless charger. Characterization results during nominal operation show the AC-to-DC power transfer efficiency for the 350kW conductive EVSE is 95.1% peak and is >92% when the AC power is at least 50 kW. The power quality of the 350 kW conductive EVSE is also measured during nominal conditions. The power factor is >0.91 for power transfer above 50 kW AC input during nominal conditions with a maximum power factor of 0.975. The AC current harmonics produced by the EVSE as measured at the AC input connection to the EVSE is <25% harmonics for power transfer greater than 50 kW and <10% harmonics for power transfer greater than 180 kW.

25 ENERGY STORAGE↗

Review of Tools for Modeling Core Radial Expansion in Liquid Metal-Cooled Fast Reactors

Core radial expansion in liquid-metal cooled fast reactor systems is a well-known phenomenon that produces strong reactivity feedback effects. It is crucial from a safety standpoint to design a reactor with the proper core restraint system to guide expansion of the fuel assemblies into a formation that produces negative reactivity feedback in accident conditions. However, the modeling of core radial expansion and its associated reactivity feedback is extremely challenging. Liquid metal-cooled fast reactor designers (both industry and commercial) have pointed to improved modeling of core radial expansion as a key modeling challenge for these types of reactors. The Department of Energy Nuclear Energy Advanced Modeling and Simulation (DOE-NEAMS) program has an important role to play in helping to develop a robust, predictive tool for this phenomenon. A literature review has been performed to identify current simulation capabilities applicable to the prediction of core radial expansion in liquid metal-cooled fast reactors and the resultant reactivity feedback effects. An overview as well as a detailed description of the multi-physics phenomena underlying core radial expansion is given in the first two chapters. The objective of this report is to identify existing software that has been or could be applied to the core radial expansion problem, and then to identify possible paths to develop a robust, coupled Multiphysics tool for advanced analysis, in which all three physics (radiation transport, structural mechanics, thermal fluids) are taken into account considering feedback effects from each physics to the other. Several computer codes and workflows have been developed in the United States and abroad to perform individual aspects of radial expansion calculations or to perform loosely coupled analysis. No code system currently exists which tightly and robustly couples the neutronics, thermal hydraulics, and thermal mechanical physics with enough detail to fully resolve the complex core radial expansion reactivity feedback effects. The future availability of such a code system is of vital importance to fully understanding the reactivity feedback effects that occur due to radial expansion, and consequently to optimizing the design of the core restraint system. A potential code development path forward using MOOSE-based tools is suggested in order to leverage the natural tight coupling and robustness of MOOSE-based applications. Additionally, potential gaps for modeling and common assumptions are listed which require further investigation to ensure accuracy for prediction of deformations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Single and Double-Sided Jet Impingement Cooling for SiC-Based Power Modules

Efficient thermal management of power electronics systems is crucial for higher reliability. With the miniaturization of systems, high-loss-density electronics require cooling systems that can extract a large amount of heat. This study explored a liquid-jet-impingement-based direct substrate cooling system for single-sided and double-sided cooling to improve heat extraction efficiency and improve the power density by reducing the volume and mass. The cooling system was implemented for a SiC-based direct bonded copper substrate. Numerical simulations were performed to determine the effects of nozzle diameter, the number of nozzles, and nozzle array orientation on single-sided cooling and thermal performance gain over double-sided cooling. A novel manifold design was proposed that reduced the volume and mass of the manifold and still achieved the target power density. The performance of the proposed design was compared with the pin-fin-based cooling system used in the BMW I3 module, and a comparative analysis was done.

Barua, Himel↗

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

New High-Strength Ni-based Alloys for High Temperature Service in Liquid Fluoride Salt Environments

The ever-increasing demand for higher system thermal efficiency necessitates the operation of power generation cycles and heat conversion systems for chemical processes at progressively higher temperatures. As the system operating temperature increases, fewer and fewer materials are available with the required mechanical properties and environmental compatibility. This dearth of materials is particularly acute in structural applications at temperatures above 700°C in liquid Fluoride Salt Cooled High-Temperature Reactors (FHRs) and Concentrated Solar Power (CSP) systems where liquid fluoride and/or liquid chloride salts are used for their high thermal capacity and low thermal conductivity to store and transport heat. It has been shown that fluorides and chlorides can degrade the properties of the material used for storage and transport due to corrosive effects thus affecting the performance and lifetime characteristics. Thus, materials used for storage and transport for fluoride/chloride-salt must at the minimum have good compatibility with the salt by exhibiting low corrosion rates at the required temperatures. In addition, since many of the components will be subject to stresses in service, they need to have sufficient strength to resist plastic deformation, and the resistance to time dependent creep deformation at these temperatures, and stress levels. Achieving the combination of these properties required for higher temperatures is particularly challenging considering traditionally, the expected lifetime of some of the components used in these systems are from 30 years (CSP) to 80 years (FHRs). Although 316 stainless steel and associated redox corrosion reduction techniques are being considered for use in the first generational systems, use of 316SS is limited to operating temperatures up to ~ 650°C, thereby resulting in lower reactor efficiencies. Hastelloy ® N, developed at ORNL in the 1950s-60s for molten salt service is currently the leading candidate FHR structural alloy but has inadequate creep properties at high temperatures. Using a computationally-guided approach, Oak Ridge National Laboratory had developed new high strength alloys strengthened by γ’ precipitates (about 2X the strength of Hastelloy ® N) in small laboratory-scale heats that show good resistance to corrosion by fluorides and improved creep rupture life at temperatures up to 850°C (U.S. Patent Application No. 13/833,357 entitled “High Strength Alloys for High Temperature Service in Liquid-Salt Cooled Energy Systems”- granted U. S. Patent No. 9,540,714).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of MOOSE-Based Tools for Calculating Radial Core Expansion

Radial core expansion in liquid-metal cooled fast reactor systems is a well-known phenomenon that produces strong reactivity feedback effects. An inherently safe reactor design takes advantage of negative reactivity feedback in accident scenarios by utilizing a core restraint system which produces a bowed shape that allows for radial expansion of the fuel regions. Detailed modeling and simulation of core radial expansion itself as well as subsequent reactivity feedback is a challenging task involving contact of many fuel assembly elements and physics feedback from neutronics, thermal hydraulics, and thermal mechanical response. A variety of physics codes have been developed to model aspects of radial core expansion but in general invoke geometrical or physics approximations. No code system currently exists which tightly and robustly couples these physics with enough detail to fully resolve the complex core radial expansion reactivity feedback effects. The future availability of such a code system is of vital importance to fully understanding the reactivity feedback effects that occur due to radial expansion, and consequently to optimizing the design of the core restraint system. A high-fidelity code will also be used to benchmark existing lower fidelity, faster running models to understand their benefits, limitations, and range of applications. A code development path using MOOSE-based tools is proposed in order to leverage the detailed geometry capabilities and natural tight coupling and robustness of MOOSE-based applications for modeling this complex phenomena. While simulation of the full phenomenon involves several physics, an assessment has been initiated on the capabilities and readiness of the currently available Tensor Mechanics module within MOOSE for calculation of the structural mechanical responses which occur within the reactor core. This report focuses on modeling the force-deformation response which mimics the physics of a duct contact deformation, as well as differential thermal expansion which produces a thermal bowed shaped for the fuel assemblies in a core. Simple examples were initially performed such as simple supported beam bending under load. The complexity of examples was progressively increased to better mimic the duct behavior by including a differential thermal example and inclusion of hexagonal cross-sections in the geometry. Further assessment of the structural mechanical response simulation capability is still required for modeling duct contact interactions and irradiation creep and swelling. Companion thermal hydraulic and neutronics assessments will also be required; these activities are planned for future years. Finally, integration of the multiple physics components through MOOSE is required to predict the core radial expansion and subsequent feedback effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gear Test Assembly – Experimental Testing and Gear Analysis (FY2021 Year End Report)

The Gear Test Assembly (GTA) is an experimental apparatus designed to test mechanical components used in fuel handling systems of liquid-sodium cooled fast-spectrum nuclear reactors. The performance and lifetime of gears, bearings, and dynamic seals are the primary focus of study. Three experimental campaigns have been completed since the start of operation in 2019, and the GTA is currently assembled and ready to begin the fourth experimental campaign. Sodium operations at the Mechanisms Engineering Test Loop (METL) have been paused while repairs are made to the Building 308 Alkali Metal Scrubber. This work is nearly complete, and once METL is brought back into operation the GTA will begin sodium testing immediately.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plant Engineers Solar Energy Handbook: Southern California Region

Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.

14 SOLAR ENERGY↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generic Behavior of Ultrastability and Anisotropic Molecular Packing in Codeposited Organic Semiconductor Glass Mixtures

Vapor-deposited glass mixtures of organic semiconductors commonly serve as active layers in organic electronic devices, whose lifetime and performance are strongly influenced by the stability and structure of these mixed glasses. Here, we study the stability and anisotropic molecular packing of six co-deposited organic semiconductor glass mixtures with 50:50 weight ratio, by differential scanning calorimetry and spectroscopic ellipsometry. We also find that all six binary systems exhibit high kinetic stability and significantly reduced enthalpy relative to the corresponding liquid-cooled glassy mixtures (ultrastable behavior), even for systems where the glass transition temperatures of the components differ by more than 90 K. Furthermore, we demonstrate that the birefringence of a co-deposited glass mixture, a measure of its anisotropic packing, can be predicted from the birefringence of glasses of the two pure components. These results for stability and structure are expected to be applicable to other co-deposited organic semiconductor glass mixtures, so long as the two components mix well in the glass and individually can form ultrastable glasses. Therefore, our findings are significant for designing novel electronic devices with enhanced device lifetime and increased operational efficiency.

36 MATERIALS SCIENCE↗

Experimental Validation of Thermal Hydraulic Behavior in Sodium Fast Reactors (SFR) with the Thermal Hydraulic Experimental Test Article (THETA)

Thermal stratification and transition to natural circulation pose two of the largest sources of uncertainty in systems-level modeling of liquid metal-cooled fast reactors. As these phenomena typically develop during transient event sequences, licensing-basis events analyzed using systemslevel models may have considerable uncertainties associated with thermal-hydraulic parameters of the system to account for these phenomena. As a result, the validation basis for these phenomena for systems-level codes is insufficient to fully support the wide range of liquid metal fast reactors being developed in the US. Currently, the most viable path for licensing a design is to take significant conservatisms and maintain sufficiently large safety margins to account for this uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.