Engineering PapersSearch

SEARCH · Engineering Papers

Results for “linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)

Transverse BBU Suppression with Feedback for Energy Recovery Linacs

In this study, we present beam dynamics simulations of the Strong Hadron Cooling (SHC) Energy Recovery Linac (ERL) that incorporate a feedback (FB) system designed to mitigate Beam Breakup (BBU) instabilities. The FB effectively suppresses BBU and increases the threshold current by roughly an order of magnitude. Our analysis revealed the aliasing behavior of the dominant higher-order mode (HOM) and its suppression by the FB, as evident from the power spectral density (PSD) of the beam centroid’s horizontal motion at the exit of the final linac section. Although the FB system— even when affected by noise—successfully reduced the BBU peak, it also amplified the PSD at other frequencies. These results provide important insights into BBU suppression and threshold current enhancement in ERLs.

Setiniyaz, S. [Thomas Jefferson National Accelerat

Design and optimization of higher order mode couplers for the superconducting cavities of the PERLE energy recovery linac

The Powerful Energy Recovery Linac for Experiments (PERLE) is an energy recovery linac (ERL) facility based on superconducting radio-frequency (SRF) technology to be hosted at the Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab) in France. With a target beam power of 10 MW, PERLE aims to demonstrate the high-current, continuous wave, multi-pass operation to validate options for future high-energy machines, such as the 50 GeV ERL proposed for the Large Hadron electron Collider (LHeC) and the Future Circular electron-hadron Collider (FCC-eh), and host dedicated particle physics and nuclear experiments. In high-current ERLs, the regenerative Beam Breakup (BBU), emerging from the beam and cavity Higher Order Modes (HOMs) interaction, is a major concern for their stable operation. Beam-induced HOMs can increase the cavity heat load at cryogenic temperature and cause beam instabilities. HOM couplers are installed in the cavity beam pipes to absorb HOM energy and mitigate these effects. This thesis presents the design and optimization of several coaxial HOM couplers for the 5-cell 801.58 MHz elliptical Nb cavities of the 500 MeV PERLE ERL configuration. The RF transmission of the HOM couplers was optimized to enhance the damping of the most dangerous HOMs. The optimized HOM couplers were integrated into endgroups to simulate their damping performance and thermal behavior. The optimized HOM couplers were 3D-printed in epoxy and copper-coated. Low-power RF measurements were conducted on the produced HOM couplers installed in copper PERLE-type cavities to validate their damping performance and propose several endgroups for the PERLE 5-cell cavity to mitigate HOMs below the BBU instability limits.

Barbagallo, Carmelo

A multi-scale cognitive interaction model of instrument operations at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is the world’s first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S. Department of Energy. As beam time at LCLS is extremely valuable and limited, experimental efficiency—getting the most high quality data in the least time—is critical. Our overall project employs cognitive engineering methodologies with the goal of improving experimental efficiency and increasing scientific productivity at LCLS by refining experimental interfaces and workflows, simplifying tasks, reducing errors, and improving operator safety and stress. Here, in this study, we describe a multi-agent, multi-scale computational cognitive interaction model of instrument operations at LCLS. Our model simulates the aspects of human cognition at multiple cognitive and temporal scales, ranging from seconds to hours, and among agents playing multiple roles, including instrument operator, real time data analyst, and experiment manager. The model can roughly predict impacts stemming from proposed changes to operational interfaces and workflows. Example results demonstrate the model’s potential in guiding modifications to improve operational efficiency. We discuss the implications of our effort for cognitive engineering in complex experimental settings and outline future directions for research. The model is open source, and the videos of the supplementary material provide extensive detail.

47 OTHER INSTRUMENTATION

Radiation Shielding Analysis of Linac Extension Area in APS Using FLUKA and PHITS Monte Carlo Radiation Transport Codes

The Linac extension area tunnel can accept 300- to 500-MeV electrons for experiments. Radiations from various normal and accident beam loss scenarios were analyzed with the FLUKA and PHITS Monte Carlo radiation transport codes. In normal beam loss scenarios, the beam was dumped on the horizontal and vertical beam dumps, while the accident scenarios were horizontal and vertical mis-steered beams that can occur due to incorrect beam energy and magnet settings. The extent of beam deviation, which was established using particle tracking studies, was used to define the beam directions in the Monte Carlo transport calculations. Further, a mis-steered condition, where the beam was not intercepted by the dumps, was also analyzed. For the horizontal dump, the PHITS results above the berm were higher for neutrons and somewhat lower for photons, compared to the FLUKA results. Comparison of the secondary particle yields from FLUKA and PHITS from an Al block with dimensions comparable to what was used in the beam dumps showed a 40% higher neutron yield and a 10% lower photon yield. Finally, to ensure compliance with Argonne National Laboratory's shielding policy, the design of the horizontal beam dump was modified, and additional shielding was recommended.

FLUKA

Demonstration of a diamond anvil cell platform at the Linac Coherent Light Source: capabilities and outlook

A novel X-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. The new diamond window at the Matter at Extreme Conditions (MEC) instrument allows hard X-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures, and details of the X-ray beam and diagnostics. Example data are presented, including a reversible XFEL-induced phase transition in CsPbI 3 . The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.

Linac Coherent Light Source (LCLS)

48 Ca(p,pn) 47 Ca linac production for the preparation of a 47 Ca/ 47 Sc generator

Here, the production of 47 Sc via the nuclear reaction 48 Ca(p,pn) 47 Ca→(β-, T 1/2 = 4.54 d) 47 Sc and the assembly of a 47 Ca/ 47 Sc generator system has been investigated at Brookhaven National Laboratory. To produce 47 Ca, a pressed nat CaCl 2 target was irradiated with a proton beam at energy on target of 27.5 MeV at Brookhaven Linac Isotope Producer. Irradiated targets were dissolved in water and then acidified with concentrated HCl before separation using extraction chromatography through a diglycolamide (DGA) resin column. After ingrowth, 47 Sc was collected at >90 % with low contamination from both nonradioactive metals and coproduced radionuclides. A total of four 47 Ca/ 47 Sc separations were performed with 6–7 days between the irradiation and the separation to allow the equilibration of the ingrowing 47 Sc.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS

Beam breakup instability studies of powerful energy recovery linac for experiments

The maximum achievable beam current in an energy recovery linac (ERL) is often constrained by beam breakup (BBU) instability. Our previous research highlighted that filling patterns have a substantial impact on BBU instabilities in multipass ERLs. In this study, we extend our investigation to the eight-cavity model of the Powerful ERL for Experiment (PERLE). We evaluate its requirements for damping cavity higher order modes (HOMs) and propose optimal filling patterns and bunch timing strategies. Our findings reveal a significant new insight: while filling patterns are crucial, the timing of bunches also plays a critical role in mitigating HOM beam loading and BBU instability. This previously underestimated factor is essential for effective BBU control. We estimated the PERLE threshold current using both analytical and numerical models, incorporating the designed PERLE HOM dampers. During manufacturing, HOM frequencies are expected to vary slightly. Our study found no significant difference in BBU suppression for relative rms frequency jitters of 0.001, 0.002, and 0.005 for the same HOM. Introducing a jitter of 0.001 into our models, we found that the dampers effectively suppressed BBU instability, achieving a threshold current an order of magnitude higher than the design requirement. Our results offer new insights into ERL BBU beam dynamics and have important implications for the design of future ERLs. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)

Macromolecular crystallography and biology at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) has significantly impacted the field of biology by providing advanced capabilities for probing the structure and dynamics of biological molecules with high precision. The ultrashort coherent X-ray pulses from the LCLS have enabled ultrafast, time-resolved, serial femtosecond crystallography that is inaccessible at conventional synchrotron light sources. Since the facility's founding, scientists have captured detailed insights into biological processes at atomic resolution and fundamental timescales. The ability to observe these processes in real time and under conditions closely resembling their natural state is transforming our approach to studying biochemical mechanisms and developing new medical and energy applications. This work recounts some of the history of the LCLS, advances in biological research enabled by the LCLS, key biological areas that have been impacted and how the LCLS has helped to unravel complex biological phenomena in these fields.

59 BASIC BIOLOGICAL SCIENCES

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics

Automated RF Phase Adjustment for Beam Stabilization in the Fermilab Linac

The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally corrected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift correction, employing a prototype-based classification approach. Our model utilizes a 34-dimensional feature set (RF settings and BPM readings) and leverages a 7x27 response matrix for system modeling. To overcome limited real-world data, we generate synthetic data, enhancing model training and generalizability. Custom loss functions, including a surrogate energy-consistent loss and a temporal smoothness constraint, ensure physically plausible drift predictions. The goal is a robust system for autonomous phase adjustments, ensuring stable beam acceleration and reduced manual intervention.

Chichili, R. R. [Illinois U., Chicago]

Design of a microbunched electron cooler energy recovery linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics

Measuring orbit responses with oscillating trajectories in the Fermilab Linac

Recording changes in beam transverse positions and longitudinal phase reported by Beam Position Monitors (BPMs) in response to a beam deflection by an upstream dipole corrector or RF cavity phase (orbit response) is a powerful tool for analysis of accelerator optics and assisting with machine tuning. In Fermilab Linac, orbit responses were recorded by oscillating the corrector currents and cavity phases in a sinusoidal manner parasitically during regular operation, simultaneously oscillating up to 19 correctors and 7 cavities at distinct frequencies, providing faster, drift-resistant measurements through frequency-domain analysis. This report describes the technique, including error estimations and consistency checks and shows examples of the measurements.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501

Space charge studies on strong hadron cooler energy recovery linac

An Energy Recovery Linac (ERL) based cooler, using Coherent electron Cooling (CeC) is being designed for cooling hadron beams of the Electron-Ion Collider (EIC). The ERL design utilizes highcurrent, high-brightness electron beams with low emittance and a uniform longitudinal distribution for efficient hadron cooling. This is designed to operate in two modes to accommodate cooling requirements for hadron bunches at 100 GeV and 275 GeV, each with an average current of 100 mA and 1 nC bunch charge. With these parameters, the space charge effects become significant in this ERL design due to the low beam energy and high beam current. In this paper, we discuss strategies for including space charge effects in the optics design and implementation of an interface for space charge dominated and non-dominated regions of this ERL lattice.

Accelerator Physics

Calibration and Measurement techniques in the LLRF systems of the Fermilab PIP-II Linac

he PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems are a based on two different hardware platforms controlling a variety of cavity types and resonance control systems including temperature, pneumatic and piezzo tuners. The various calibrations required prior to beam operation include, signal power, gradient, amplifier characterization, cavity Q measurement and detune constants. Measurements such as piezzo capacitance, cavity piezo transfer function help in determining tuner health and in devising microphonics control strategies. These measurement and calibration methods of the PIP-II LLRF system are discussed here.

Varghese, P.

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip