Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lighting quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Plastoquinone redox status influences carboxysome integrity via a RpaA ‐ and reactive oxygen species‐dependent regulatory network

SUMMARY Carboxysomes are bacterial microcompartments that encapsulate Rubisco and are a core component of the cyanobacterial carbon concentration mechanism (CCM). While carboxysome number, size, and spatial organization vary in different environmental conditions (CO 2 , light availability, redox state, temperature, and light quality), the molecular mechanisms underlying this potentially adaptive process remain elusive. Herein, we observe that mutants of the circadian rhythm/metabolism factor, Regulator of Phycobilisome Association A (RpaA), exhibit a striking breakdown of carboxysomes under certain environmental conditions. We find that conditions leading to overreduction of the plastoquinone (PQ) pool (mixotrophic growth, high irradiance, or chemical inhibition of electron transfer from PQ to the cytochromeb 6 fcomplex) are accompanied by an elevated generation of reactive oxygen species (ROS) and correlate with the loss of carboxysome integrity. Carboxysome breakdown is reversed by environmental conditions or chemical inhibitors that prevent PQ overreduction and accompanying ROS generation. Taken together, our data support a novel link between the redox status of the PQ pool and carboxysome integrity. Our results have implications for the fundamental understanding of cyanobacterial energy‐balancing pathways and may indicate new research directions for understanding how the carboxysome is remodeled in response to changing environments.

Plant Sciences↗

LiDAR For Heliostat Optical Assessment (Final Report)

This project has sought to develop new uses for surveying-quality Light Detecting and Ranging (LiDAR) 3D scanning sensors in the automatic/autonomous assessment of optical errors in largescale concentrating solar power heliostat fields. Past experiments have demonstrated the ability of a 3D-LiDAR to acquire highly accurate point cloud measurements across several Sandia NSTTF heliostats. The goal of this project is to expand upon this work to see if and how it can be used in large commercial heliostat fields.

14 SOLAR ENERGY↗

Examining Perceptual Luminance Uniformity of Simulated Luminaire Patterns

Luminaire luminance uniformity is an important aspect that can affect perceived lighting quality, discomfort glare, and efficacy. While several metrics have been proposed to characterize luminance uniformity, previous studies have shown that current metrics such as Max:Min or Avg:Min luminance ratios can be insensitive to important differences in luminance gradient that may affect perceived uniformity. In an attempt to resolve this issue, previous studies incorporated a contrast sensitivity function for the human eye based on spatial frequency, such as in the UHVS metric; however, this metric has not been comprehensively studied in relation to perceived uniformity ratings. The study presented in this paper aimed to examine the relationship between the UHVS metric and perceived uniformity ratings. Specifically, the study used a web-based questionnaire that presented simulated luminance patterns and asked participants to assess uniformity using a two-alternative forced-choice procedure. Responses were collected and analyzed from 94 participants. The results showed a significant correlation and relationship between the UHVS metric and perceived uniformity. However, comparisons between patterns that had similar UHVS and between patterns that had larger differences in UHVS did not yield consistent results. These results suggest that the UHVS metric might be used for general guidance but may warrant further studies to better understand its sensitivity and improve its alignment with perceived uniformity ratings.

Abboushi, Belal K.↗

Modular low cost trackerless spectral sensor

A non-tracking solar sensor device and systems. The non-tracking solar sensor system includes a transparent hemispherical dome enclosure for receiving light. A diffuser is disposed with the enclosure for diffusing the light. A photodiode sensor array senses at least one discrete wavelength of the diffused light. A data acquisition module is configured to receive a sensor signal from the sensor array, the signal indicative of light quality at least one discrete wave band for processing via a processor module.

Armijo, Kenneth M.↗

Let's Get Greedy: The L-Prize Invites Innovators to 'Have It All'

LEDs have arrived. They’re long-lasting, energy-efficient, and priced competitively with the products they’re replacing. Case closed and let’s move on, right? And yet… transformative lighting has the capacity do more, with excellent energy and application efficiency, data-driven functionality, material sustainability, and the ability to make buildings better places to work, live, learn, and heal – for people in all communities. This article on the DOE L-Prize invites competitors to participate in the $12.2 million L-Prize competition. The competition sets ambitious innovation goals for efficacy, quality of light, connectivity, material sustainability, and diversity, equity, and inclusion. LED lighting offers the opportunity to address all of these - to "have it all". The article will be published in the August edition of Lighting Design and Application (LD&A) magazine.

LED Lighting, Efficacy, Lighting Quality, Connecte↗

Opinion: Lighting Research During and After the Pandemic

For many lighting researchers, the recent restrictions related to COVID-19 have paused most in-person laboratory or field experiments. In certain countries, regulatory institutions have allowed such experiments to resume but issued safety recommendations like pre-checking participants for disease symptoms and excluding those that are especially vulnerable. To avoid potential complications and delays, researchers are likely to resort to other research designs that enable remote research — eliminating the need for the experimenter and subjects to be in the same room. While unanticipated, this shift to remote research methods is an opportunity to revisit and further develop remote experimental techniques, which can have beneficial long-lasting implications on lighting research during and after the pandemic. Perhaps the most common type of remote research is online experiments; which can greatly benefit from improved techniques to allow for greater control or characterization of experimental conditions, like those proposed by Villa and Labayrade . These techniques require validation specific to the type of response collected and context, e.g. space type and attributes. New research techniques continue to emerge and will enable remote collection of objective measures such as gaze direction and high dynamic range images (HDRIs) without specialized equipment. In fact, many of these methods and techniques are commonly used in other disciplines, like vision science and psychology, and can be adapted for lighting research. Not all lighting studies can be conducted online, but in the age of ubiquitous and connected technologies, there is a largely missed opportunity to utilize crowdsourced responses to lighting conditions in real environments where people live and go about their daily lives without the research being limited to a certain time and laboratory locations. For instance, outdoor street luminaires can be rated by passersby using ecological momentary assessments on mobile phones. While this approach does not provide laboratory-level control over experimental conditions, it can provide more contextual responses resulting from ‘normal’ dynamic gaze, behavior, and interactions. Further, it can also reduce bias related to the experimental setting. Further development of remote research methods and their use in lighting research can improve the quality of lighting research. Given that sample sizes in most lighting research are relatively small, remote research can substantially increase sample sizes, reduce research costs, and shorten study duration, all while reducing interaction between experimenter and subjects. Another benefit is reaching a wider audience and including under-represented individuals who typically are not reachable using common recruitment methods. The pandemic has set back our plans for in-lab experiments, but can it inspire us to think of new and creative ways to expand lighting research?

Abboushi, Belal K.↗

Designing an Optimal LSST Deep Drilling Program for Cosmology with Type Ia Supernovae

The Vera C. Rubin Observatory's Legacy Survey of Space and Time (LSST) is forecast to collect a large sample of Type Ia supernovae (SNe Ia) expected to be instrumental in unveiling the nature of dark energy. The feat, however, requires accurately measuring the two components of the Hubble diagram, distance modulus and redshift. Distance is estimated from SN Ia parameters extracted from light-curve fits, where the average quality of light curves is primarily driven by survey parameters. An optimal observing strategy is thus critical for measuring cosmological parameters with high accuracy. We present in this paper a three-stage analysis to assess the impact of the deep drilling (DD) strategy parameters on three critical aspects of the survey: redshift completeness, the number of well-measured SNe Ia, and cosmological measurements. We demonstrate that the current DD survey plans (internal LSST simulations) are characterized by a low completeness (z ~ 0.55–0.65), and irregular and low cadences (several days), which dramatically decrease the size of the well-measured SN Ia sample. We propose a method providing the number of visits required to reach higher redshifts. We use the results to design a set of optimized DD surveys for SN Ia cosmology taking full advantage of spectroscopic resources for host galaxy redshift measurements. The most accurate cosmological measurements are achieved with deep rolling surveys characterized by a high cadence (1 day), a rolling strategy (at least two seasons of observation per field), and ultradeep (z ≳ 0.8) and deep (z ≳ 0.6) fields. A deterministic scheduler including a gap recovery mechanism is critical to achieving a high-quality DD survey.

79 ASTRONOMY AND ASTROPHYSICS↗

A Case Study of Tunable White LED Lighting with Networked Lighting Controls (Emory University Cognitive Empowerment Program)

Emory University and Georgia Institute of Technology (Georgia Tech) partnered to create the Charlie and Harriet Schaffer Cognitive Empowerment Program (CEP) facility in northeast Atlanta. Together with the funders they are building a program to help individuals experiencing mild cognitive impairment (MCI) to maintain their physical and cognitive health, and independence as long as possible. In addition to applying effective strategies and therapies, the two research groups are investigating the responses of the MCI members to treatments that involve acoustical conditions, exercise and movement, and lighting changes that may support retention or relearning of skills. Care partners and family members receive support and instruction to improve home and work life, promoting joy, purpose, and wellness in the family groups. The lighting system uses tunable-white LEDs, employing luminaires with both warm and cool-color emitters that can be dimmed separately to produce any white correlated color temperature (CCT) between 2700 K and 6500 K. All luminaires were dimmable to achieve subdued or lively surroundings for different treatments, time-of-day, and mood. A central networked digital control system was employed to allow tuning of multiple spaces together (for example, bright, cool morning light could be programmed for extra stimulation, or lighting in all spaces at the end of the day could be reduced in both light output and CCT to promote relaxation and not interfere with the melatonin cycle of occupants). Almost all spaces were equipped with individual room control of dimming and color temperature with touch screens to allow users to tune the lighting as desired, but each room’s controls could also be specially programmed through the server in case the research staff were investigating lighting settings on learning, for example. The server incorporates a timeclock, and it is able to send signals to switch off all lighting after occupancy hours, or enable occupancy sensors to control the lighting. The bulk of the construction work was completed in January 2020. It was clear from an initial walk-through that although the lighting system produced the expected high light level with low-glare qualities of light, that there were issues and inconsistencies to be resolved. These were noted in an initial punchlist visit and expected to be resolved when the tech representatives from the agency visited with the electrical contractor in the following few weeks. What followed was 2.5 years of identifying unexpected lighting performance in terms of light output, color, scheduling, and occupancy. This report documents the issues encountered in the effort to get the lighting and controls systems to operate as intended. It concludes with guidance for design professionals and manufacturers to help avoid problematic complexity in future projects.

42 ENGINEERING↗

Fundamental limits to the generation of highly displaced bright squeezed light using linear optics and parametric amplifiers

High-quality squeezed light is an important resource for a variety of applications. Multiple methods for generating squeezed light are known, having been demonstrated theoretically and experimentally. However, the effectiveness of these methods—in particular, the inherent limitations to the signals that can be produced—has received little consideration. Here we present a comparative theoretical analysis for generating a highly displaced squeezed light from a linear optical method—a beamsplitter mixing a squeezed vacuum and a strong coherent state—and well-studied parametric amplification methods including an optical parametric oscillator, an optical parametric amplifier, and a dissipative optomechanical squeezer seeded with coherent states. We show that the quality of highly displaced squeezed states that can be generated using these methods is limited on a fundamental level by the physical mechanism utilized; across all methods there are significant trade-offs between displacement, squeezing, and overall uncertainty. We explore the nature and extent of these trade-offs specific to each mechanism and identify the optimal operation modes for each. Finally, we identify the conditions for minimum-uncertainty squeezing in arbitrary parametric amplifying systems and show that displacing the output signal will in general violate these conditions, adding noise and degrading squeezing. Published by the American Physical Society 2025

Young, Steve M. (ORCID:0000000173839366)↗

Human-Centric Lighting: Foundational Considerations and a Five-Step Design Process

At its best, human-centric lighting considers the visual and non-visual effects of light in support of positive human outcomes. At its worst, it is a marketing phrase used to healthwash lighting products or lighting design solutions. There is no doubt that environmental lighting contributes to human health, but how might one practice human-centric lighting given both the credible potential and the implausible hype? Marketing literature is filled with promises. Technical lighting societies have summarized the science but have not yet offered design guidance. Meanwhile, designers are in the middle, attempting to distinguish credible knowledge from that which is dubious to make design decisions that affect people directly. This article is intended to: (1) empower the reader with fundamental understandings of ways in which light affects health; (2) provide a process for human-centric lighting design that can dovetail with the decision-making process that is already a part of a designer's workflow.

60 APPLIED LIFE SCIENCES↗

Optically thin light-absorbers for increasing photochemical energy-conversion efficiencies

Photochemical energy conversion is more efficient when a single light-absorbing unit is split into multiple light-absorbing units (N) that are each 1/N as thick as the single light-absorbing unit and thus use the same amount of material as the single light-absorbing unit. For electrocatalytic parameters relevant to water electrolysis, the maximum efficiency for solar-to-fuel conversion from a 1.75 eV bandgap material increases from approximately 1% for a single light-absorbing unit to greater than 20% for 128 identical stacked light-absorbing units. Alterations in utilization of photons results in a better match of the light-absorber power output to the load of the chemical transformation and in the case of high-quality light-absorbers there is an added benefit from radiative coupling between the light-absorbing units via photon recycling.

Ardo, Shane↗

The Dark Energy Survey Supernova Program: Light Curves and 5 Yr Data Release

We present griz photometric light curves for the full 5 yr of the Dark Energy Survey Supernova (DES-SN) program, obtained with both forced point-spread function photometry on difference images (DiffImg) performed during survey operations, and scene modelling photometry (SMP) on search images processed after the survey. This release contains 31,636 DiffImg and 19,706 high-quality SMP light curves, the latter of which contain 1635 photometrically classified SNe that pass cosmology quality cuts. This sample spans the largest redshift (z) range ever covered by a single SN survey (0.1 < z < 1.13) and is the largest single sample from a single instrument of SNe ever used for cosmological constraints. We describe in detail the improvements made to obtain the final DES-SN photometry and provide a comparison to what was used in the 3 yr DES-SN spectroscopically confirmed Type Ia SN sample. We also include a comparative analysis of the performance of the SMP photometry with respect to the real-time DiffImg forced photometry and find that SMP photometry is more precise, more accurate, and less sensitive to the host-galaxy surface brightness anomaly. The public release of the light curves and ancillary data can be found at github.com/des-science/DES-SN5YR and doi:10.5281/zenodo.12720777.

79 ASTRONOMY AND ASTROPHYSICS↗

System-Level Optimization to Improve Biofuel Potential via Genetic Engineering and Hydrothermal Liquefaction

The economic success of biofuels and bioproducts depends on system-level optimization including biomass production and conversion. Hydrothermal liquefaction (HTL) can convert wet biomass such as microalgae into a biofuel intermediate (BFI) under elevated temperatures and pressure. An understanding of the impacts of biomass composition on BFI yield and quality can inform genetic engineering strategies in the improvement of biochemical composition for biofuel production. In this work, wild type cyanobacterium Synechocystis sp. PCC 6803 biomass was doped with various common cellular storage compounds in lab-scale HTL experiments. Doping with glycogen or polyhydroxybutyrate (PHB) significantly reduced BFI yields, while doping with triglycerides (TAG) or medium chain-length polyhydroxyalkanoate (mcl-PHA) increased BFI yield and quality. In light of these observations, a genetically engineered Synechocystis strain deficient in glycogen biosynthesis was cultivated to produce biomass for HTL, leading to a 17% increase in BFI yield. In addition, we built a multiphase component additivity (MCA) model that can predict BFI yield and quality with PHAs in the biomass. This work demonstrates an effective strategy to integrate strain development with downstream biomass conversion to maximize biofuel yield, with lessons applicable to microalgae as well as other biomass.

09 BIOMASS FUELS↗

Probing Light-Dependent Regulation of the Calvin Cycle Using a Multi-Omics Approach

Photoautotrophic microorganisms are increasingly explored for the conversion of atmospheric carbon dioxide into biomass and valuable products. The Calvin-Benson-Bassham (CBB) cycle is the primary metabolic pathway for net CO 2 fixation within oxygenic photosynthetic organisms. The cyanobacteria, Synechocystissp. PCC 6803, is a model organism for the study of photosynthesis and a platform for many metabolic engineering efforts. The CBB cycle is regulated by complex mechanisms including enzymatic abundance, intracellular metabolite concentrations, energetic cofactors and post-translational enzymatic modifications that depend on the external conditions such as the intensity and quality of light. However, the extent to which each of these mechanisms play a role under different light intensities remains unclear. In this work, we conducted non-targeted proteomics in tandem with isotopically non-stationary metabolic flux analysis (INST-MFA) at four different light intensities to determine the extent to which fluxes within the CBB cycle are controlled by enzymatic abundance. The correlation between specific enzyme abundances and their corresponding reaction fluxes is examined, revealing several enzymes with uncorrelated enzyme abundance and their corresponding flux, suggesting flux regulation by mechanisms other than enzyme abundance. Additionally, the kinetics of 13 C labeling of CBB cycle intermediates and estimated inactive pool sizes varied significantly as a function of light intensity suggesting the presence of metabolite channeling, an additional method of flux regulation. These results highlight the importance of the diverse methods of regulation of CBB enzyme activity as a function of light intensity, and highlights the importance of considering these effects in future kinetic models.

54 ENVIRONMENTAL SCIENCES↗

Controllable Phycobilin Modification: An Alternative Photoacclimation Response in Cryptophyte Algae

Cryptophyte algae are well-known for their ability to survive under low light conditions using their auxiliary light harvesting antennas, phycobiliproteins. Mainly acting to absorb light where chlorophyll cannot (500-650 nm), phycobiliproteins also play an instrumental role in helping cryptophyte algae respond to changes in light intensity through the process of photoacclimation. Until recently, photoacclimation in cryptophyte algae was only observed as a change in the cellular concentration of phycobiliproteins; however, an additional photoacclimation response was recently discovered that causes shifts in the phycobiliprotein absorbance peaks following growth under red, blue, or green light. Here, we reproduce this newly identified photoacclimation response in two species of cryptophyte algae and elucidate the origin of the response on the protein level. We compare isolated native and photoacclimated phycobiliproteins for these two species using spectroscopy and mass spectrometry, and we report the X-ray structures of each phycobiliprotein and the corresponding photoacclimated complex. We find that neither the protein sequences nor the protein structures are modified by photoacclimation. We conclude that cryptophyte algae change one chromophore in the phycobiliprotein β subunits in response to changes in the spectral quality of light. Ultrafast pump-probe spectroscopy shows that the energy transfer is weakly affected by photoacclimation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanism of Antiferroelectricity in Polycrystalline ZrO 2

The size and electric field dependent induction of polarization in antiferroelectric ZrO 2 is the key to several technological applications that are unimaginable a decade ago. However, the lack of a deeper understanding of the mechanism hinders progress. Molecular dynamics simulations of polycrystalline ZrO 2 , based on machine-learned interatomic forces with near ab initio quality, shed light on the fundamental mechanism of the size effect on the transition fields. Stress in the oxygen sublattice is the most important factor. The so constructed interatomic forces allow the calculation of the transition fields as a function of the ZrO 2 film thickness and predict the ferroelectricity at large thickness. The simulation results are validated with electrical and piezo response force microscopy measurements. The results allow a clear interpretation of the properties of the double-hysteresis loops as well as the construction of the free energy landscape of ZrO 2 grains.

36 MATERIALS SCIENCE↗

The Dark Energy Survey Supernova Program: Cosmological Analysis and Systematic Uncertainties

We present the full Hubble diagram of photometrically classified Type Ia supernovae (SNe Ia) from the Dark Energy Survey supernova program (DES-SN). DES-SN discovered more than 20,000 SN candidates and obtained spectroscopic redshifts of 7000 host galaxies. Based on the light-curve quality, we select 1635 photometrically identified SNe Ia with spectroscopic redshift 0.10 < z < 1.13, which is the largest sample of supernovae from any single survey and increases the number of known z > 0.5 supernovae by a factor of 5. In a companion paper, we present cosmological results of the DES-SN sample combined with 194 spectroscopically classified SNe Ia at low redshift as an anchor for cosmological fits. Here we present extensive modeling of this combined sample and validate the entire analysis pipeline used to derive distances. We show that the statistical and systematic uncertainties on cosmological parameters are ${\sigma }_{{{\rm{\Omega }}}_{M},\mathrm{stat}+\mathrm{sys}}^{{\rm{\Lambda }}\mathrm{CDM}}=$ 0.017 in a flat ΛCDM model, and $({\sigma }_{{{\rm{\Omega }}}_{M}},{\sigma }_{w}{)}_{\mathrm{stat}+\mathrm{sys}}^{w\mathrm{CDM}}$ = (0.082, 0.152) in a flat wCDM model. Combining the DES SN data with the highly complementary cosmic microwave background measurements by Planck Collaboration reduces by a factor of 4 uncertainties on cosmological parameters. In all cases, statistical uncertainties dominate over systematics. We show that uncertainties due to photometric classification make up less than 10% of the total systematic uncertainty budget. This result sets the stage for the next generation of SN cosmology surveys such as the Vera C. Rubin Observatory's Legacy Survey of Space and Time.

79 ASTRONOMY AND ASTROPHYSICS↗

High-quality Extragalactic Legacy-field Monitoring (HELM) with DECam

High-quality Extragalactic Legacy-field Monitoring (HELM) is a long-term observing program that photometrically monitors several well-studied extragalactic legacy fields with the Dark Energy Camera (DECam) imager on the CTIO 4m Blanco telescope. Since Feb 2019, HELM has been monitoring regions within COSMOS, XMM-LSS, CDF-S, S-CVZ, ELAIS-S1, and SDSS Stripe 82 with few-day cadences in the $(u)gri(z)$ bands, over a collective sky area of $\sim 38$ deg${\rm ^2}$. The main science goal of HELM is to provide high-quality optical light curves for a large sample of active galactic nuclei (AGNs), and to build decades-long time baselines when combining past and future optical light curves in these legacy fields. These optical images and light curves will facilitate the measurements of AGN reverberation mapping lags, as well as studies of AGN variability and its dependences on accretion properties. In addition, the time-resolved and coadded DECam photometry will enable a broad range of science applications from galaxy evolution to time-domain science. We describe the design and implementation of the program and present the first data release that includes source catalogs and the first $\sim 3.5$ years of light curves during 2019A--2022A.

79 ASTRONOMY AND ASTROPHYSICS↗