Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Transition radiation light sources

Transition radiation from nanotubes, nanosheets, and nanoparticles and in particular, boron nitride nanomaterials, can be utilized for the generation of light. Wavelengths of light of interest for microchip lithography, including 13.5 nm (91.8 eV) and 6.7 nm (185 eV), can be generated at useful intensities, by transition radiation light sources. Light useful for monitoring relativistic charged particle beam characteristics such as spatial distribution and intensity can be generated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Review of the 1st EUV Light Sources Code Comparison Workshop

We review the results of the 1 st Extreme Ultraviolet (EUV) Light Sources Code Comparison Workshop. The goal of this workshop was to provide a platform for specialists in EUV light source plasma modeling to benchmark and validate their numerical codes using well-defined case studies. Detailed consideration of a plethora of atomic collisional and radiative processes is required for modeling EUV light source plasmas. Eight institutions spanning four countries contributed data to the workshop. Two topics were addressed, namely (i) the atomic kinetics and radiative properties of tin plasmas under EUV-generating conditions and (ii) laser absorption in a fully ionized, one-dimensional hydrogen plasma. In this paper, we summarize the key findings of the workshop and outline plans for future iterations of the code comparison activity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating Advanced Light Source Science Through Multi-Facility HPC Workflows

Synchrotron light sources support a wide array of techniques to investigate materials, often producing complex, high-volume data that challenge traditional workflows. At the Advanced Light Source (ALS), we developed infrastructure to move microtomography data over ESnet to ALCF and NERSC, where CPU- and GPU-based algorithms generate 3D reconstructed volumes of experimental samples. We employ two data movement and reconstruction models: real-time processing as data streams directly to NERSC compute nodes, and automated file transfer to NERSC and ALCF file systems. The streaming pipeline provides users with feedback in under ten seconds, while the file-based workflow produces high-quality reconstructions suitable for deeper analysis in 20-30 minutes. This infrastructure enables users to utilize HPC resources without direct access to backend systems. We plan to extend this architecture to more endstations, supporting our beamline scientists and users.

Abramov, David↗

On-PIC Light Source Integration & Micro-dispensing of Solder Paste for Flip Chip Application

To reach the next level benefits of photonic integrated circuits (PICs), the Integrated Photonic Systems Roadmap-International describes the necessity of either heterogeneous or hybrid integration of light sources [1]. A new approach for hybrid integration is Photonic Wire Bonding where 3D nanolithography is used to pattern a polymer waveguide that connects light sources to PIC waveguides. The waveguides resemble electrical wire bonds and essentially do the same as their electrical counterpart for packaging photonic chips together. In order to reap the full benefits of a photonic wire bonds, the light source must be carefully packaged. In this work I seek to expand RIT’s photonic packaging capability by establishing a packaging process to integrate light sources, specifically an Indium Phosphide distributed feedback lasers and a reflective semiconductor optical amplifiers, directly onto a photonic integrated circuits. Another necessary requirement for PIC packaging is densely integrated electrical connectivity. In this thesis I developed a fine pitch flip chip interconnect technique demonstrated using gold stud bumps in conjunction with micro-dispensed solder paste. This work opens the door to high density photonic flip chip applications. The micro-dispensed solder paste dots having diameters 50-125 µm are currently being tested at a pitch of 150 µm . The gold stud bumps are formed with 1mil gold wire creating bumps with a diameter of 40-60 µm depending on specific parameter values. These capabilities will allow RIT to assemble and test novel photonic integrated devices, cutting down on the time and cost associated with third party assembly and tests facilities. Thereby keeping RIT at the forefront of photonic research.

Wongk, Nicole↗

Developing in-situ capabilities for synchrotron light source relevant to PNNL mission research areas

The main objective of the proposed research is to engage synchrotron light source capabilities to address the critical mission areas at PNNL. We have carried out Multi-model chemical analysis and imaging to unravel the role of surface chemistry during realistic heterogeneous interfacial processes - through a close collaboration that will help BES and BER research projects. In particular, we performed the following activities to understand role of surface chemistry on metal and oxide reactivity and metal ion transfer across oxide surface and aqueous solutions: 1) Perform light source experiments utilizing samples generated at PNNL; 2) Develop early career PNNL scientists utilizing light sources; 3) Build collaborations with ALS scientists in developing new in-situ capabilities; 4) Complete AMBER capabilities in collaboration with ALS scientists and make those available to the scientific community including PNNL scientists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavefront Preservation in Soft X-Ray Beamlines for the Advanced Light Source Upgrade

In the 4th generation of X-ray light sources, including Free-Electron Lasers (FEL) and Diffraction-Limited Storage Rings (DLSR), the emittance of the electron beam is small or negligible compared to the emittance of the photon beam produced by insertion devices, thus generating coherent beams of light. Over the next few years, several lightsource facilities will be built or upgraded to produce X-ray beams of unprecedented coherent flux. Delivering these exceptional beams to the sample chambers requires beamline optical systems that are designed to preserve the wavefront properties. Our goal in the Advanced Light Source upgrade project (ALS-U) is to create a new class of beamlines that reach diffraction-limited X-ray optical quality through tightly integrated, efficient optical systems, diagnostics, and adaptive mirrors, thus providing users with new scientific capabilities offered by coherent X-ray light interactions with matter. Herein we describe aspects of the beamlines’ design as they enter the project’s final design phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Application of deep learning methods for beam size control during user operation at the Advanced Light Source

Past research at the Advanced Light Source (ALS) provided a proof-of-principle demonstration that deep learning methods could be effectively employed to compensate for the significant perturbations to the transverse electron beam size induced by user-controlled adjustments of the insertion devices. However, incorporating these methods into the ALS’ daily operations has faced notable challenges. The complexity of the system’s operational requirements and the significant upkeep demands has restricted their sustained application during user operation. Here, we introduce the development of a more robust neural network (NN)-based algorithm that utilizes a novel online fine-tuning approach and its systematic integration into the day-to-day machine operations. Our analysis emphasizes the process of NN model selection, demonstrates the superior performance of the NN-based method over traditional feedback methods, and examines the effectiveness and resilience of the new algorithm during user-operation scenarios. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Broadband impedance modeling and single bunch instabilities estimations of the advanced light source upgrade project

We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of the keto-enol tautomerization in acetaldehyde, acetone, cyclohexanone, and methyl vinyl ketone with a novel VUV light source

The discovery of enols in combustion environments and our atmosphere has garnered increasing attention to the many unanswered questions surrounding enol chemistry. The scarcity of experimental data concerning these enols renders combustion and atmospheric models with a lack of constraining parameters, leading to varying computational predictions. Experimental detection is difficult because mass spectrometry, a powerful tool for probing a wide variety of species, cannot distinguish between enols and their thermodynamically favorable ketone isomers. A solution to this ambiguity is to use tunable vacuum ultraviolet (VUV) light from a synchrotron to identify the presence of the enol by its lower ionization energy compared to the isomer. We present a tabletop-scale VUV light source that implements highly cascaded harmonic generation, a new regime of cascaded nonlinear optics, to provide a set of spectral lines spaced by 1.2 eV. We demonstrate that the variety of photon energies available allows us to detect the keto-enol tautomerization of four aldehydes and ketones. By combining this novel VUV light source with an established microreactor, we first revisit the formation of vinyl alcohol from acetaldehyde and confirm that the observed isomerization is indeed unimolecular. Secondly, we observe the thermal tautomerization of acetone to propen-2-ol for the first time. Finally, we observe the thermal tautomerization of cyclohexanone to 1-cyclohexenol and methyl vinyl ketone to 2-hydroxybutadiene, where the results are in good agreement with those reported at a synchrotron. Furthermore, our measurements can be used to constrain models, inform future experimental studies of enol reactivity, and potentially enhance current understanding of combustion and environmental chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Measurement of shock roughness due to phase plate speckle imprinting relevant for x-ray diffraction experiments on 3rd and 4th generation light sources

Laser-shock compression experiments at 3rd and 4th generation light sources generally employ phase plates, which are inserted into the beamline to achieve a repeatable intensity distribution at the focal plane. Here, the laser intensity profile is characterized by a high-contrast, high-frequency laser speckle. Without sufficient smoothing, these laser non-uniformities can translate to a significant pressure distribution within the sample layer and can affect data interpretation in x-ray diffraction experiments. Here, we use a combination of one- and two-dimensional velocity interferometry to directly measure the extent to which spatial frequencies within the laser focal spot intensity pattern are smoothed out during propagation within the laser plasma and a polyimide ablator. We find that the use of thicker polyimide layers results in spatially smoother shock fronts, with the greatest degree of smoothing associated with the highest spatial frequencies. Focal spots with the smallest initial speckle separation produce the most rapid smoothing. Laser systems that employ smoothing by spectral dispersion techniques to rapidly modulate the focal plane intensity distribution are shown to be the most effective ones in producing a spatially smooth shock front. We show that a simple transport model combined with the known polyimide Hugoniot adequately describes the extent of shock smoothness as a function of polyimide thickness. Finally, our results provide a description of spatial structure smoothing across a shock front, which can be used to design targets on x-ray free electron laser facilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demonstration of a diamond anvil cell platform at the Linac Coherent Light Source: capabilities and outlook

A novel X-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. The new diamond window at the Matter at Extreme Conditions (MEC) instrument allows hard X-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures, and details of the X-ray beam and diagnostics. Example data are presented, including a reversible XFEL-induced phase transition in CsPbI 3 . The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.

Linac Coherent Light Source (LCLS)↗

Sextupole reduction via chaos suppression at the National Synchrotron Light Source II

We revisit the nonlinear lattice design approach for the National Synchrotron Light Source II (NSLS-II) storage ring. By suppressing chaos, we identify alternative sextupole configurations to the original design, which relied on the conventional strategy of simultaneously minimizing resonance driving terms (RDTs) and amplitude-dependent detuning (ADD). These alternatives achieve comparable performance while requiring fewer sextupoles. A detailed comparison of two representative solutions is presented and supported by experimental validation. Our results show that the dynamic aperture correlates more strongly with global chaos than with individual RDTs, and that the importance of minimizing ADD may have been overstated in earlier design strategies.

36 MATERIALS SCIENCE↗