Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light field imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Chlorophyll fluorescence imaging captures photochemical efficiency of grain sorghum (Sorghum bicolor) in a field setting

Abstract Background Photosynthesis is one of the most important biological reactions and forms the basis of crop productivity and yield on which a growing global population relies. However, to develop improved plant cultivars that are capable of increased productivity, methods that can accurately and quickly quantify photosynthetic efficiency in large numbers of genotypes under field conditions are needed. Chlorophyll fluorescence imaging is a rapid, non-destructive measurement that can provide insight into the efficiency of the light-dependent reactions of photosynthesis. Results To test and validate a field-deployed fluorescence imaging system on the TERRA-REF field scanalyzer, leaves of potted sorghum plants were treated with a photosystem II inhibitor, DCMU, to reduce photochemical efficiency (F V /F M ). The ability of the fluorescence imaging system to detect changes in fluorescence was determined by comparing the image-derived values with a handheld fluorometer. This study demonstrated that the imaging system was able to accurately measure photochemical efficiency (F V /F M ) and was highly correlated ( r = 0.92) with the handheld fluorometer values. Additionally, the fluorescence imaging system was able to track the decrease in photochemical efficiency due to treatment of DCMU over a 7 day period. Conclusions The system’s ability to capture the temporal dynamics of the plants’ response to this induced stress, which has comparable dynamics to abiotic and biotic stressors found in field environments, indicates the system is operating correctly. With the validation of the fluorescence imaging system, physiological and genetic studies can be undertaken that leverage the fluorescence imaging capabilities and throughput of the field scanalyzer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rotational Velocities of Am and Non-chemical-peculiar Stars Based on Kepler and LAMOST DR5

Rotation is a critical physical process operating in the formation of Am stars. There is a strong correlation between low-velocity rotation and chemical peculiarity. However, the existence of many non-chemical-peculiar slow rotators challenges the understanding of Am stars. The purpose of our work is to search for low-velocity rotating non-chemical-peculiar A-type stars and Am stars and to make a comparative analysis. In this paper, we pick out a sample from the LAMOST–Kepler project, including 21 Am stars, 125 non-chemical-peculiar slow rotators, and 53 non-chemical-peculiar fast rotators. We calculate the rotational frequencies through a periodic change of light curves caused by inhomogeneous stellar surfaces and then obtain the rotational velocities. For slow rotators, the age of Am stars is statistically younger than that of non-chemical-peculiar stars in the same temperature bin. In the comparison of the period, the average amplitude, and stellar mass of Am and non-chemical-peculiar stars, we discover that there is no difference in the photometric variability between Am and non-chemical-peculiar stars, which implies similar inhomogeneities on the surfaces. The average amplitude of non-chemical-peculiar stars has a downward trend with the increase of effective temperature and stellar mass, which is consistent with the theoretical prediction caused by weak dynamo-generated magnetic fields in A-type stars. In addition, we confirm four non-chemical-peculiar stars that have flares by checking field-of-view images, pixel images, and pixel-level light curves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Lens-free compound eye cameras based on angle-sensitive meta-surfaces

A lens-free ultrathin imaging sensor using a compound-eye vision modality can be formed by forming a metasurface on each pixel of an array of pixels in a solid state imaging sensor. The metasurface can be configured to form a diffraction grating that directs light incident on the metasurface at a predefined angle to excite surface plasmon polaritons into the solid state imaging sensor and light incident at any other angle is reflected or diffracted away from the metasurface. Each pixel of the imaging sensor can be configured using the metasurface to only receive light incident from a different portion of a field of view. A computational imaging system can be used to construct the image from the individual pixels.

Paiella, Roberto↗

Field-resolved space–time characterization of few-cycle structured light pulses

Accompanied by the rapid development of ultrafast laser platforms in recent decades, the spatiotemporal manipulation of ultrashort laser pulses has attracted much attention due to the potential for cutting-edge applications of structured light, including optical tweezers, optical communications, super-resolution imaging, time-resolved spectroscopy in molecules and quantum materials, and strong-field physics. Today, techniques capable of characterizing the full spatial, temporal, and polarization state properties of structured light are strongly desired. Here, we demonstrate a technique, termed 3D TIPTOE, for characterizing structured mid-infrared waveforms, which uses only a two-dimensional silicon-based image sensor as both the detector and the nonlinear medium. By combining the advantages of the sub-cycle time resolution afforded by nonlinear excitation and the spatial resolution inherent to the two-dimensional sensor, the 3D TIPTOE technique allows full characterization of structured electric fields, significantly reducing the complexity of detection compared to other techniques. The validity of the technique is established by measuring both few-cycle Bessel–Gaussian pulses and radially polarized femtosecond vector beams.

Liu, Yangyang (ORCID:0000000335205332)↗

Imaging Light‐Induced Migration of Dislocations in Halide Perovskites with 3D Nanoscale Strain Mapping

Abstract In recent years, halide perovskite materials have been used to make high‐performance solar cells and light‐emitting devices. However, material defects still limit device performance and stability. Here, synchrotron‐based Bragg coherent diffraction imaging is used to visualize nanoscale strain fields, such as those local to defects, in halide perovskite microcrystals. Significant strain heterogeneity within MAPbBr 3 (MA = CH 3 NH 3 + ) crystals is found in spite of their high optoelectronic quality, and both 〈100〉 and 〈110〉 edge dislocations are identified through analysis of their local strain fields. By imaging these defects and strain fields in situ under continuous illumination, dramatic light‐induced dislocation migration across hundreds of nanometers is uncovered. Further, by selectively studying crystals that are damaged by the X‐ray beam, large dislocation densities and increased nanoscale strains are correlated with material degradation and substantially altered optoelectronic properties assessed using photoluminescence microscopy measurements. These results demonstrate the dynamic nature of extended defects and strain in halide perovskites, which will have important consequences for device performance and operational stability.

36 MATERIALS SCIENCE↗

Development of a true single line of sight 3D hot-spot imaging for the National Ignition Facility

High resolution 3D self-emission x-ray imaging during inertial confinement fusion capsule implosion enables the measurement of the shape of the hotspot. While current 3D imaging capabilities use multiple lines of sight to perform image reconstruction, it would be highly desirable to use only one line of sight, as this would significantly reduce the number of windows in the target hohlraum and decrease their impacts on implosion symmetry. Such a goal is achievable using the zone plate coded imaging technique developed by N. M. Ceglio [Proc. SPIE 0106, 55-62 (1977)]. It consists of fielding a visible light Fresnel zone plate on shot to record a shadowgraph. Here, the image can then be reconstructed either by printing the shadowgraph on a transparent film and shining a suitable wavelength light through it or by numerical reconstruction. A new approach using numerical reconstruction is presented, and it relaxes the constraint by an order of magnitude on the optic design, thus enabling an easier fabrication process, as it allows a scaling-up of the optic dimensions. The design, fabrication process, and testing with an x-ray source of a prototype is presented. The reconstruction of an ~14.5 × 17 μm 2 broadband x-ray source was successful and shows that the performances are in line with expectation with an at least 5 mm axial resolution.

47 OTHER INSTRUMENTATION↗

Conservation of angular momentum in second harmonic generation from under-dense plasmas

Spin and orbital angular momentum of an optical beam are two independent parameters that exhibit distinct effects on mechanical objects. However, when laser beams with angular momentum interact with plasmas, one can observe the interplay between the spin and the orbital angular momentum. Here, by measuring the helical phase of the second harmonic 2ω radiation generated in an underdense plasma using a known spin and orbital angular momentum pump beam, we verify that the total angular momentum of photons is conserved and observe the conversion of spin to orbital angular momentum. We further determine the source of the 2ω photons by analyzing near field intensity distributions of the 2ω light. The 2ω images are consistent with these photons being generated near the largest intensity gradients of the pump beam in the plasma as predicted by the combined effect of spin and orbital angular momentum when Laguerre-Gaussian beams are used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-field imaging and spectroscopy of terahertz resonators and metasurfaces [Invited]

Terahertz (THz) metasurfaces have become a key platform for engineering light-matter interaction at THz frequencies. They have evolved from simple metallic resonator arrays into tunable and programmable devices, displaying ultrafast modulation rates and incorporating emerging quantum materials. The electrodynamics which govern metasurface operation can only be directly revealed at the scale of subwavelength individual metasurface elements, through sampling their evanescent fields. It requires near-field spectroscopy and imaging techniques to overcome the diffraction limit and provide spatial resolution down to the nanoscale. Through a series of case studies, this review provides an in-depth overview of recently developed THz near-field microscopy capabilities for research on metamaterials.

Hale, Lucy L. (ORCID:0000000176544272)↗

Metastability and Degradation of CdTe Solar Cells Investigated by nm-Scale Electrical Potential Imaging

We report on investigations of reversible metastability and irreversible degradation of MZO/CdSeTe/CdTe devices from the perspective of electric field across the device using Kelvin probe force microscopy (KPFM). The device showed reversible transitions between the light-soak state (LSS) with the best device efficiency and the dark-soak state (DSS) with an inferior efficiency. However, it showed an irreversible degradation state (DgS) driven by long-hour light soaking at an elevated temperature. The nm-scale KPFM electric field imaging on cross-sections of the devices revealed different anomalous electric field profiles. The electric field at the LSS exhibits a main peak inside the CdSeTe layer but not at the MZO/CdSeTe heterointerface, demonstrating that working junction of the device is a buried homojunction (BHJ). At the DSS, a second electric field peak was observed at the MZO/CdSeTe interface with a similar strength to the main BHJ, which probably caused the decrease in fill factor at the DSS. At the DgS, the electric field peak at the MZO/CdSeTe interface increased significantly and a third electric field was measured at the back contact of the device. Device modeling using COMSOL and in alignment with both the electric field and device current-voltage curves suggest that a slightly low n-doped CdSeTe in the region near the MZO/CdSeTe interface caused the BHJ, and that either a loss of MZO doping or increase of the conduction band offset spike due to long-term stress caused the fill factor-dominated degradation and the increased electric field near the MZO/CdSeTe interface at the DgS. The former, MZO doping decrease, is more plausible by referring the related literature.

BHJ↗

Shape- and Orientation-Dependent Scattering of Isolated Gold Nanostructures Using Polarized Dark-Field Microscopy

In this work, we demonstrate a simple and robust method for measuring the shape- and orientation-dependent optical scattering of various plasmonic nanostructures adsorbed onto a solid surface using polarized dark-field microscopy. By analyzing the dark-field scattering images of gold nanostructures using grazing incidence polarized light with a bench-top microscope, we are able to correlate optical scattering from the individual nanostructures with their shape and orientation. Depending on the size, shape, and orientation of the plasmonic nanostructures, they exhibit characteristic angle- and polarization-dependent scattering signals. Extracting the red, green, and blue channels of the scattering signals from a color-imaging detector as a function of azimuthal angle provides a polar plot of color intensity values that is characteristic of the underlying nanostructure. Examples are presented for various nanostructures, including spherical nanoparticles, nanotriangles, and nanorods. Experimental results are complemented by numerical calculations of the scattering spectra of representative model nanostructures. We demonstrate that the polarization- and orientation-dependent scattering behavior is a consequence of various localized surface plasmon modes existing in the nanostructures and can be used to verify the shape of individual objects as well as quickly identify the orientation of numerous objects on a densely populated substrate. We anticipate that this method will provide a rapid and efficient complement to the typical structural analysis of nanoparticles that is achieved by electron microscopy as well as providing a simple method for generating detailed information of the optical scattering of various types of individual plasmonic nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

Fluid Flow Observations of The Spray Near-Field Using High-Speed X-Ray Imaging

Sprays are important to may industrial processes, but the near-field region where spray formation takes place is difficult to visualize and characterize through visible light imaging because this region is typically optically dense. X-ray imaging is one technique that can penetrate this optically dense region and provide unique observations of the spray formation process. This study uses high-speed white beam X-ray imaging conducted at the Advanced Photon Source to capture spray formation dynamics from a canonical airblast atomizer. In this work, a range of momentum flux ratios are visualized by varying the gas flow rate while the liquid flow rate is held constant. The use of X-rays show overlapping flow structures including bags, ligaments, mushrooms, and webs. Air bubbles are captured within the liquid regions, and a very dynamic crown forms at the liquid needle exit at higher momentum flux ratios. Finally, at the highest momentum flux ratios, air bubbles and liquid droplets are observed migrating upstream in the center of the crown, and this motion is attributed to a toroidal recirculation cell at the nozzle exit.

47 OTHER INSTRUMENTATION↗

Super-resolution Imaging of Plasmonic Near-Fields: Overcoming Emitter Mislocalizations

Plasmonic nano-objects have shown great potential in enhancing applications like biological/chemical sensing, light harvesting and energy transfer, and optical/quantum computing. Therefore, an extensive effort has been vested in optimizing plasmonic systems and exploiting their field enhancement properties. Super-resolution imaging with quantum dots (QDs) is a promising method to probe plasmonic near-fields but is hindered by the distortion of the QD radiation pattern. Here, we investigate the interaction between QDs and “L-shaped” gold nanoantennas and demonstrate both theoretically and experimentally that this strong interaction can induce polarization-dependent modifications to the apparent QD emission intensity, polarization, and localization. Based on FDTD simulations and polarization-modulated single-molecule microscopy, we show that the displacement of the emitter’s localization is due to the position-dependent interference between the emitter and the induced dipole, and can be up to 100 nm. Our results help pave a pathway for higher precision plasmonic near-field mapping and its underlying applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultimate brightness of a medium-energy synchrotron light source at operational beam intensity

Synchrotron light sources are key instruments of modern science, providing unique opportunities for groundbreaking studies in diverse scientific disciplines and driving innovation in numerous scientific and technological fields. Fourth-generation light sources provide unprecedented capabilities in imaging, spectroscopy and diffraction techniques. Ultimate brightness is the key to advancing to a smaller scale, faster response, and higher data measurement and processing rate. The brightness is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of the electron bunches combined with a very small transverse beam size. Consequently, the high particle density leads to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance and brightness scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction and bunch lengthening provided by higher-harmonic RF systems to identify optimal combinations of machine and beam parameters.

36 MATERIALS SCIENCE↗

Quantitative investigation of sooting dynamics in droplet combustion using an automated image analysis algorithm

This paper reports an image analysis approach using a newly-developed open-source program to extract quantitative measurements of soot volume fraction (SVF) from digital video images of burning n-heptane droplets. The automated program developed in this work can analyze images of fixed and untethered droplets to quantify sooting dynamics. The images analyzed in the program were taken from experiments carried out in the Multi-user Droplet Combustion Apparatus (MDCA) onboard the International Space Station (ISS). In these experiments, video imaging of burning droplets was obtained using backlighting by a laser diode with a wavelength of 653 nm. Here, the light was collimated before it passed through the droplet and soot-containing region, after which the light was then attenuated and projected onto the camera’s sensors. This technique facilitates the measurements of SVF based on the principles of the full field light extinction method (FFLEM). The measurements provide quantitative data that reveal the sooting dynamics of liquid fuels during droplet combustion processes. The analyses of a soot-attenuating image (ISS n-heptane, untethered droplet) at an instant during the burning show that the SVF distribution has a peak at the soot shell location. It then decreases due to soot oxidation when the location is further away from the burning droplet. Regarding temporal effects on the maximum SVF (SVF max ), results show that SVF max first increases after the burning is initiated until a peak value is reached, after which SVF max decreases. The SVF max values identified in this study for n-heptane are quantitatively consistent with previously reported values for fiber-supported droplets and are reached relatively early in the burning history. n-Heptane images are also analyzed to show the effects of initial droplet sizes on the maximum soot volume fraction. Results show that SVF max decreases with increasing initial droplet size, which is consistent with visual observations of less soot formed and dimmer flame brightness as Do increases.

42 ENGINEERING↗