Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leakage inductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of the Transformer Magnetizing Inductance on the Performance of the Dual-Active Bridge Converter

The magnetizing inductance of the high-frequency transformer in the dual-active bridge (DAB) converter is usually assumed to be much larger than its leakage inductance, thereby the magnetizing current can be negligible. However, ignoring the magnetizing current will lead to an error in the DAB converter design process. This paper analyzes the operation and performance of the DAB converter for a general case in which the transformer magnetizing inductance is taken into consideration. The analysis shows that the magnetizing inductance impacts the soft-switching region, the power transfer capability, and the leakage inductor current. A simulation case study is provided to verify the analysis. A DAB converter prototype is built to experimentally validate the analysis as well.

Yin, Shiyuan↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Evaluation of half wave induction motor drive for use in passenger vehicles

Research performed at the University of Missouri-Columbia to devise and design a lower cost inverter induction motor drive for electrical propulsion of passenger vehicles is described. A two phase inverter motor system is recommended. The new design is predicted to provide comparable vehicle performance, improved reliability and a cost advantage for a high production vehicle, decreased total rating of the power semiconductor switches, and a somewhat simpler control hardware compared to the conventional three phase bridge inverter motor drive system. The major disadvantages of the two phase inverter motor drive are that it is larger and more expensive than a three phase machine, the design of snubbers for the power leakage inductances produce higher transient voltages, and the torque pulsations are relatively large because of the necessity to limit the inverter switching frequency to achieve high efficiency.

Hoft, R. G.↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

A Novel Low-Profile High-Efficiency Three-Phase Matrix Transformer

High step-down isolated DC-DC conversion from an 800 V DC bus to low-voltage, high-current outputs is required in automotive auxiliary converters and data center power supplies. In such applications, conventional transformer-based converters require large turns ratios, which increase winding resistance, leakage inductance, and magnetic height. This paper proposes a novel low-profile three-phase matrix transformer that realizes a large effective voltage ratio through flux division among multiple secondary legs, without increasing the physical turns count of each winding. As a result, the proposed structure reduces copper usage and transformer height while preserving the voltage conversion capability of a conventional three-phase transformer. Finite element analysis shows that the proposed design reduces magnetic height by 27%, ferrite volume by 34%, and copper volume by 28%. Circuit-level simulations of an 800 V/12 V,3 kW CLLLC dual-active-bridge converter further show that the lower winding resistance reduces total system loss by 91% and increases DC-DC efficiency from 82.6% to 97.6% at 3 kW output.

Inoue, Shuntaro [ORNL] (ORCID:0000000262637627)↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Isolated transfer of analog signals

Technique transfers analog signal levels across high isolation boundary without circuit performance being affected by magnetizing reactance or leakage inductance. Transfers of analog information across isolated boundary are made by interrupting signal flow, with switch, in such a manner as to produce alternating signal which is applied to transformer.

Bezdek, T.↗

Voltage-spike analysis for a free-running parallel inverter

Unwanted and sometimes damaging high-amplitude voltage spikes occur during each half cycle in many transistor saturable-core inverters at the moment when the core saturates and the transistors switch. The analysis shows that spikes are an intrinsic characteristic of certain types of inverters even with negligible leakage inductance and purely resistive load. The small but unavoidable after-saturation inductance of the saturable-core transformer plays an essential role in creating these undesired thigh-voltage spikes. State-plane analysis provides insight into the complex interaction between core and transistors, and shows the circuit parameters upon which the magnitude of these spikes depends.

Lee, F. C. Y.↗

Lightweight, high-frequency transformers

The 25-kVA space transformer was developed under contract by Thermal Technology Laboratory, Buffalo, N. Y. The NASA Lewis transformer technology program attempted to develop the baseline technology. For the 25-kVA transformer the input voltage was chosen as 200 V, the output voltage as 1500 V, the input voltage waveform as square wave, the duty cycle as continuous, the frequency range (within certain constraints) as 10 to 40 kHz, the operating temperatures as 85 deg. and 130 C, the baseplate temperature as 50 C, the equivalent leakage inductance as less than 10 micro-h, the operating environment as space, and the life expectancy as 10 years. Such a transformer can also be used for aircraft, ship and terrestrial applications.

Schwarze, G. E.↗

High power density dc/dc converter: Selection of converter topology

The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

Divan, Deepakraj M.↗

Spacing Windings Evenly In Toroidal Inductors

Technique for winding toroidal inductor results in even spacing of windings around toroidal core. Heat-shrinkable tubing locks it in place. Shrinkable tubing not necessary to get good results. Minimizes proportion of leakage inductances, especially if core has relatively low permeability. Intended for use in power supply operating at frequency between 250 kHz and 2 MHz.

Mclyman, W. T.↗

High power density dc-to-dc converters for aerospace applications

Three dc-to-dc converter topologies aimed at high-power high-frequency applications are introduced. Major system parasitics, namely, the leakage inductance of the transformer and the device output capacitance are efficiently utilized. Of the three circuits, the single-phase and three-phase versions of the dual active bridge topology demonstrate minimal stresses, better utilization of the transformer, bidirectional, and buck-boost modes of operation. All circuits operate at a constant switching frequency, thus simplifying design of the reactive elements. The power transfer characteristics and soft-switching regions on the Vout-Iout plane are identified. Two coaxial transformers with different cross-sections were built for a rating of 50 kVA. Based on the single-phase dual active bridge topology, a 50 kW, 50 kHz converter operating at an input voltage of 200 Vdc and an output voltage of 1600 Vdc was fabricated. Characteristics of current-fed output make the dual active bridge topologies amenable to paralleling and hence extension to megawatt power levels. Projections to a 1 MW system operating from a 500 Vdc input, at an output voltage of 10 kVdc and a switching frequency of 50 kHz, using MOS-controlled thyristors, coaxially wound transformers operating at three times the present current density with cooling, and multilayer ceramic capacitors, suggests an overall power density of 0.075 to 0.08 kg/kW and an overall efficiency of 96 percent.

Divan, Deepakraj M.↗

Optimal Hairpin Winding Configuration for EV Traction Motors to Enhance Active CMV Cancellation Capability of NPL.X Inverter

Active common-mode voltage (CMV) cancellation in neutral-point-less (NPL.X) inverter is an effective approach for reducing common-mode electromagnetic interference and alleviating voltage stress associated with high-speed switching in EV traction drives. However, the existing hairpin winding configuration often exhibits impedance imbalance due to slot leakage inductance and manufacturing constraints, limiting the effectiveness of active CMV cancellation. This paper investigates symmetric hairpin winding configurations for a dual-three-phase EV traction machine to improve impedance symmetry. Considering the manufacturing constraints of six-layer hairpin windings, four feasible symmetric winding configurations are analyzed. Two-dimensional finite-element analysis is performed to extract the impedance parameters of each configuration. The extracted impedance parameters are used to quantify the impedance mismatch between complementary phase pairs and evaluate its influence on active CMV cancellation. The results show that the fully interleaved winding configuration achieves perfectly balanced phase impedances with 0 % mismatch, whereas the mismatch in the other configurations ranges from approximately 2.4 % to 0.8 %. Consequently, the resulting total CMV overshoot is significantly suppressed to near zero voltage under high-voltage and high switching frequency operating conditions, demonstrating the importance of winding symmetry for maximizing the active CMV cancellation capability of the NPL.X inverter.

Lee, Kangbeen [Purdue Univ., West Lafayette, IN (U↗

Introduction of a Variable Inductance Transformer for the Design of Resonant Power Converters

Magnetic integration is a hot topic in power electronics that concerns the use of a transformer’s leakage and magnetizing inductances purposefully in isolated power electronic converters, thereby giving the opportunity to save the cost and footprint of any additional inductor. This is of prime interest, especially in CLLLC resonant converters which require up to three inductors. For a complete integration of these inductances, the concept of a variable inductance transformer (VIT) is introduced in this thesis. A VIT is an adaptive magnetic structure that facilitates an easy adjustment of both magnetizing and leakage inductances to meet their desired values. However, for a more promising design, an accurate estimation of these inductances is necessary. While the evaluation of magnetizing inductance is quite straightforward, the calculation of leakage inductance is rather convoluted, because the leakage inductance is influenced by both the winding layout and the operating frequency. In this thesis, three new semi-analytical methods for calculating the frequency-independent leakage inductance, and a novel semi-analytical method for evaluating the frequency-dependent leakage inductance are proposed. These methods can calculate the respective leakage inductances of a VIT within an outstanding ±5% uncertainty. Finally, a bidirectional CLLLC resonant dc-dc converter is investigated for the constant current constant voltage (CCCV) charging of the next-generation 900 V traction battery of an electric vehicle. A new voltage gain equation is derived for designing the CLLLC resonant tank, and a small-signal model is presented for designing the variable-frequency feedback controller. Furthermore, a new methodology to design a VIT is developed to overcome the challenges associated with small coupling coefficients and guarantee a complete magnetic integration of the tank inductances. All theoretical results presented herein are verified through simulations and experiments performed on hardware prototypes designed in the lab.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnetic Shield Design for the Double-D Coil-Based Wireless Charging System

In this work, magnetic field emission (MFE) of the high-power double-D (DD) coil-based wireless charging system is investigated and a shielding technique is proposed. The MFE pattern produced by the DD coils is significantly different from the MFE of the unipolar (e.g., circular, square, or rectangular) coils, and the traditional aluminum shield does not suppress the MFE from the DD coils. This study shows that a conventional aluminum shield increases the MFE, and a magnetic shield effectively suppresses the MFE of the DD coils. Therefore, a magnetic shield consisting of high-permeability magnetic material, such as ferrites, nanocrystalline, etc., is proposed for the DD pads. The shielding effectiveness of the proposed shield is evaluated through finite element analysis and verified through experiments. An 11 kW DD coil-based wireless charging system was used to test the proposed shielding technique. The experimental results show that a traditional aluminum shield increased the MFE by 29.8%, and the proposed magnetic shield suppressed the MFE by 50.5%.

42 ENGINEERING↗