Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leaf nodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

36 records · Page 2

A Scalable Monitoring for the CMS Filter Farm Based on Elasticsearch

A flexible monitoring system has been designed for the CMS File-based Filter Farm making use of modern data mining and analytics components. All the metadata and monitoring information concerning data flow and execution of the HLT are generated locally in the form of small documents using the JSON encoding. These documents are indexed into a hierarchy of elasticsearch (es) clusters along with process and system log information. Elasticsearch is a search server based on Apache Lucene. It provides a distributed, multitenant-capable search and aggregation engine. Since es is schema-free, any new information can be added seamlessly and the unstructured information can be queried in non-predetermined ways. The leaf es clusters consist of the very same nodes that form the Filter Farm thus providing natural horizontal scaling. A separate central” es cluster is used to collect and index aggregated information. The fine-grained information, all the way to individual processes, remains available in the leaf clusters. The central es cluster provides quasi-real-time high-level monitoring information to any kind of client. Historical data can be retrieved to analyse past problems or correlate them with external information. We discuss the design and performance of this system in the context of the CMS DAQ commissioning for LHC Run 2.

Andre, J. M.↗

SU-C-BRB-04: Characteristics and Performance Evaluation of the First Commercial MLC for a Robotic Delivery System

Purpose: To assess characteristics and performance of the “Incise™” MLC (41 leaf pairs, 2.5mm width, FFF linac) mounted on the robotic SRS/SBRT platform “CyberKnife M6™” in a pre-clinical 5 months (11/2014–03/2015) test period. Methods: Beam properties were measured with unshielded diodes and EBT3 film. The CyberKnife workspace for MLC was analyzed by transforming robot node coordinates (cranial / body paths) into Euler geometry. Bayouth tests for leaf / bank position accuracy were performed in standard (A/P) and clinically relevant non-standard positions, before and after exercising the MLC for 10+ minutes. Total system and delivery accuracy were assessed in End-to-End tests and dosimetric verification of exemplary plans. Stability over time was evaluated in Picket-Fence-and adapted Winston-Lutz-tests (AQA) for different collimator angles. Results: Penumbrae (80–20%, with 100%=2*dose at inflection point; SAD 80cm; 10cm depth) parallel / perpendicular to leaf motion were 2.87/2.64mm for the smallest (0×76×0.75cm{sup 2}) and 5.34/4.94mm for the largest (9.76×9.75cm{sup 2}) square field. MLC circular field penumbrae exceeded fixed cones by 10–20% (e.g. 60mm: 4.0 vs. 3.6mm; 20mm: 3.6 vs. 2.9mm). Interleaf leakage was <0.5%. Clinically accessible workspace with MLC covered (non-coplanar) gantry angles of [-113°;+112°] (cranial) and [-108°;+102°] (body), and collimator angles of [-100°;+107°] (cranial) and [-91°;+100°] (body). Average leaf position offsets were ≤0.2mm in 14 standard A/P Bayouth tests and ≤0.6mm in 8 non-standard direction tests. Pre-test MLC exercise increased jaggedness (range ±0.3mm vs. ±0.5mm) and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.39±0.06mm in 6 End-to-End tests. Picket-Fence and AQA showed no adverse trends during the test period. Conclusion: The Incise™ MLC for CyberKnife M6™ displayed high accuracy and mechanical stability over the test period. The specific CyberKnife geometry and performance after exercise demand dedicated QA measures. This work is in part funded by a research grant from Accuray Inc, Sunnyvale, USA. Erasmus MC Cancer Institute also has research collaborations with Elekta AB, Stockholm, Sweden. C Fuerweger has previously received speaker honoraria from Accuray Inc, Sunnyvale, USA.

60 APPLIED LIFE SCIENCES↗

Eulerian description of high-order bounce-back scheme for lattice Boltzmann equation with curved boundary.

We propose an Eulerian description of the bounce-back boundary condition based on the high-order implicit time-marching schemes to improve the accuracy of lattice Boltzmann simulation in the vicinity of curved boundary. The Eulerian description requires only one grid spacing between fluid nodes when second-order accuracy in time and space is desired, although high-order accurate boundary conditions can be constructed on more grid-point support. The Eulerian description also provides an analytical framework for several different interpolation-based boundary conditions. For instance, the semi-Lagrangian, linear interpolation boundary condition is found to be a first-order upwind discretization that changes the time-marching schemes from implicit to explicit as the distance between the fluid boundary node and the solid boundary increases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator

Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real time tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first experimental investigation of adapting to tumor deformation has been performed using simple deformable phantoms. For the single tumor deformation, the A{sub u}+A{sub o} was reduced over 56% when deformation was larger than 2 mm. Overall, the total improvement was 82%. For the tumor system deformation, the A{sub u}+A{sub o} reductions were all above 75% and the total A{sub u}+A{sub o} improvement was 86%. Similar coverage improvement was also found in simulating deformation tracking during IMRT delivery. The deformable image registration algorithm was identified as the dominant contributor to the tracking error rather than the finite leaf width. The discrepancy between the warped beam shape and the ideal beam shape due to the deformable registration was observed to be partially compensated during leaf fitting due to the finite leaf width. The clinical proof-of-principle experiment demonstrated the feasibility of intrafraction deformable tracking for clinical scenarios. Conclusions: For the first time, we developed and demonstrated an experimental system that is capable of adapting the MLC aperture to account for tumor deformation. This work provides a potentially widely available management method to effectively account for intrafractional tumor deformation. This proof-of-principle study is the first experimental step toward the development of an image-guided radiotherapy system to treat deforming tumors in real-time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vegetation Functional Properties Determine Uncertainty of Simulated Ecosystem Productivity: A Traceability Analysis in the East Asian Monsoon Region

Global and regional projections of climate change by Earth system models are limited by their uncertain estimates of terrestrial ecosystem productivity. At the middle to low latitudes, the East Asian monsoon region has higher productivity than forests in Europe–Africa and North America, but its estimate by current generation of terrestrial biosphere models (TBMs) has seldom been systematically evaluated. Here, we developed a traceability framework to evaluate the simulated gross primary productivity (GPP) by 15 TBMs in the East Asian monsoon region. The framework links GPP to net primary productivity, biomass, leaf area and back to GPP via incorporating multiple vegetation functional properties of carbon–use efficiency (CUE), vegetation C turnover time ( τ veg ), leaf C fraction (F leaf ), specific leaf area (SLA), and leaf area index (LAI)–level photosynthesis (P LAI ), respectively. We then applied a relative importance algorithm to attribute intermodel variation at each node. The results showed that large intermodel variation in GPP over 1901–2010 were mainly propagated from their different representation of vegetation functional properties. For example, SLA explained 77% of the intermodel difference in leaf area, which contributed 90% to the simulated GPP differences. In addition, the models simulated higher CUE (18.1 ± 21.3%), τ veg (18.2 ± 26.9%), and SLA (27.4±36.5%) than observations, leading to the overestimation of simulated GPP across the East Asian monsoon region. Furthermore, these results suggest the large uncertainty of current TBMs in simulating GPP is largely propagated from their poor representation of the vegetation functional properties and call for a better understanding of the covariations between plant functional properties in terrestrial ecosystems.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-57: First Development of Adapting to Intrafraction Relative Motion Between Prostate and Pelvic Lymph Nodes Targets

Purpose Large intrafraction relative motion of multiple targets is common in advanced head and neck, lung, abdominal, gynaecological and urological cancer, jeopardizing the treatment outcomes. The objective of this study is to develop a real-time adaptation strategy, for the first time, to accurately correct for the relative motion of multiple targets by reshaping the treatment field using the multi-leaf collimator (MLC). Methods The principle of tracking the simultaneously treated but differentially moving tumor targets is to determine the new aperture shape that conforms to the shifted targets. Three dimensional volumes representing the individual targets are projected to the beam’s eye view. The leaf openings falling inside each 2D projection will be shifted according to the measured motion of each target to form the new aperture shape. Based on the updated beam shape, new leaf positions will be determined with optimized trade-off between the target underdose and healthy tissue overdose, and considerations of the physical constraints of the MLC. Taking a prostate cancer patient with pelvic lymph node involvement as an example, a preliminary dosimetric study was conducted to demonstrate the potential treatment improvement compared to the state-of- art adaptation technique which shifts the whole beam to track only one target. Results The world-first intrafraction adaptation system capable of reshaping the beam to correct for the relative motion of multiple targets has been developed. The dose in the static nodes and small bowel are closer to the planned distribution and the V45 of small bowel is decreased from 110cc to 75cc, corresponding to a 30% reduction by this technique compared to the state-of-art adaptation technique. Conclusion The developed adaptation system to correct for intrafraction relative motion of multiple targets will guarantee the tumour coverage and thus enable PTV margin reduction to minimize the high target dose to the adjacent organs-at-risk. The authors acknowledge funding support from the Australian NHMRC Australia Fellowship and NHMRC Project Grant No. APP1042375.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-17: Tracking Multiple Targets with Independent Motion in Real-Time Using a Multi-Leaf Collimator

Purpose: Multiple targets with large intrafraction independent motion are often involved in advanced prostate, lung, abdominal, and head and neck cancer radiotherapy. Current standard of care treats these with the originally planned fields, jeopardizing the treatment outcomes. A real-time multi-leaf collimator (MLC) tracking method has been developed to address this problem for the first time. This study evaluates the geometric uncertainty of the multi-target tracking method. Methods: Four treatment scenarios are simulated based on a prostate IMAT plan to treat a moving prostate target and static pelvic node target: 1) real-time multi-target MLC tracking; 2) real-time prostate-only MLC tracking; 3) correcting for prostate interfraction motion at setup only; and 4) no motion correction. The geometric uncertainty of the treatment is assessed by the sum of the erroneously underexposed target area and overexposed healthy tissue areas for each individual target. Two patient-measured prostate trajectories of average 2 and 5 mm motion magnitude are used for simulations. Results: Real-time multi-target tracking accumulates the least uncertainty overall. As expected, it covers the static nodes similarly well as no motion correction treatment and covers the moving prostate similarly well as the real-time prostate-only tracking. Multi-target tracking reduces >90% of uncertainty for the static nodal target compared to the real-time prostate-only tracking or interfraction motion correction. For prostate target, depending on the motion trajectory which affects the uncertainty due to leaf-fitting, multi-target tracking may or may not perform better than correcting for interfraction prostate motion by shifting patient at setup, but it reduces ∼50% of uncertainty compared to no motion correction. Conclusion: The developed real-time multi-target MLC tracking can adapt for the independently moving targets better than other available treatment adaptations. This will enable PTV margin reduction to minimize health tissue toxicity while remain tumor coverage when treating advanced disease with independently moving targets involved. The authors acknowledge funding support from the Australian NHMRC Australia Fellowship and NHMRC Project Grant No. APP1042375.

60 APPLIED LIFE SCIENCES↗

Exploring the benefits of using co-packaged optics in data center and AI supercomputer networks: a simulation-based analysis [Invited]

We investigate the advantages of using co-packaged optics in next-generation data center and AI supercomputer networks. The increased escape bandwidth offered by co-packaged optics provides multiple possibilities for building 50T switches and beyond, expanding the opportunities in both the data center and supercomputing domains. Furthermore, this provides network architects with the opportunity to expand their design space and develop simplified networks with enhanced network locality properties. Co-packaging at the switch and server points enables networks with double capacity while reducing the switch count by 64% compared to state-of-the-art systems. We evaluate these concepts through discrete-event simulations using all-to-all and all-reduce traffic patterns that simulate collective communications commonly found in network-bound applications. Initially, we investigate the all-to-all overhead involved in distributing the virtual machines of the applications across multiple leaf switches and compare it to the scenario in which all VMs are placed under a single switch. Subsequently, we evaluate the performance of an AI supercomputing cluster by simulating both patterns for different message sizes, while also varying the number of participating nodes. The results suggest that networks with improved locality properties become increasingly important as the network stack operates at higher speeds; for a stack latency of 1.25 µs, placing the applications under multiple switches can result in up to 68% higher completion times than placing them under a single switch. For AI supercomputers, significant improvements are observed in the mean server throughput, reaching more than 90% for configurations involving 256 nodes and message sizes of at least 128 KiB.

99 GENERAL AND MISCELLANEOUS↗

Treatment planning for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward higher-radix switches with co-packaged optics for improved network locality in data center and HPC networks [Invited]

In this work, we study the network locality improvements that can be achieved by using co-packaged optics in data center and high-performance computing (HPC) networks. The increased escape bandwidth offered by co-packaged optics can enable switches with speeds of 51.2 Tb/s and beyond. From a network architecture perspective, the key advantages of introducing co-packaged optics at the switch points include the implementation of large-scale topologies of >12,000 end points with 4× higher bisection bandwidth and the reduction of the required number of switches by >40% compared with state-of-the-art approaches. From a network operation perspective, improved network locality and faster operation can be achieved since the higher-radix switches can mitigate the impact of network contention. Placing applications under fewer leaf switches reduces the number of packets that cross the spine switches in a leaf-spine topology. The proposed scheme is evaluated via discrete-event simulations: we initially evaluate the network locality properties of the system by using virtual-machine traces from a production data center, and we subsequently quantify the performance improvements by simulating an all-to-all pattern for a variety of message sizes over a number of nodes. The results suggest that co-packaged optics form a promising solution for keeping up with bandwidth scaling in future networks. The virtual-machine analysis shows that large-scale applications can be placed under up to 50% fewer first-level switches, while the network analysis shows speedups of up to 7.1, which translates to execution time reductions of up to 26% and 42.7% for applications with communication ratios of 0.3 and 0.5, respectively.

99 GENERAL AND MISCELLANEOUS↗

A New Approach to Reduce Number of Split Fields in Large Field IMRT

Intensity-modulated radiation therapy (IMRT) has been applied for treatments of primary head with neck nodes, lung with supraclavicular nodes, and high-risk prostate cancer with pelvis wall nodes, all of which require large fields. However, the design of the Varian multileaf collimator requires fields >14 cm in width to be split into 2 or more carriage movements. With the split-field technique, both the number of monitor units (MUs) and total treatment time are significantly increased. Although many different approaches have been investigated to reduce the MU, including introducing new leaf segmentation algorithms, none have resulted in widespread success. In addition, for most clinics, writing such algorithms is not a feasible solution, particularly with commercial treatment planning systems. We introduce a new approach that can minimize the number of split fields and reduce the total MUs, thereby reducing treatment time. The technique is demonstrated on the Eclipse planning system V7.3, but could be generalized to any other system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating ecosystem water use efficiency under drought stress: a case study of the Helan Mountain region, northwest China

Context Water use efficiency (WUE) is a fundamental ecological indicator links carbon assimilation and water loss in terrestrial ecosystems. Understanding its responses to drought stress is essential for adaptive ecosystem management, particularly in climate-sensitive mountain landscapes. Objectives This study aimed to investigate drought-driven variations in WUE across major vegetation types in the Helan Mountain region of Northwest China. Specifically, we sought to identify dominant ecological drivers of WUE variability and to disentangle their relative importance and causal pathways. Methods We quantified WUE using the Moderate Resolution Imaging Spectroradiometer (MODIS) products and the Drought Severity Index (DSI) data from 2001 to 2020. To examine WUE – drought relationships across contrasting vegetation types, we employed a spatially explicit analytical framework integrating Random Forest (RF) modeling, partial correlation analysis, and structural equation modeling (SEM). Results Regional WUE exhibited relatively stable interannual dynamics, yet pronounced spatial heterogeneity that was strongly modulated by drought conditions. Vegetation properties, particularly Leaf Area Index (LAI) and Normalized Difference Vegetation Index (NDVI), emerged as the dominant determinants of WUE, with NDVI alone explaining over 20% of its spatial variance in forest and grassland during non-drought periods. SEM analyses revealed that climate forcing influenced WUE mainly through indirect pathways mediated by soil moisture availability and vegetation structural dynamics, rather than through direct climatic controls. Among all regulating factors, LAI acted as the central control node governing ecosystem carbon–water coupling. In contrast, short-term climatic stress, especially atmospheric demand and drought duration, exerted weak or negative direct effects on WUE. Ecosystem-specific responses were observed, with croplands mainly regulated by soil water availability, whereas forests and grasslands showed more sensitive to atmospheric drought stress. Together, these results reveal a hierarchical control framework where soil–vegetation interactions mediate climate impacts on WUE, driving strong spatial heterogeneity in drought responses across mountain landscapes. Conclusions Our findings highlight the pivotal role of indirect drought effects mediated by vegetation and soil processes in shaping ecosystem WUE. The identified soil–vegetation–climate regulatory hierarchy provides mechanistic insight into landscape–scale drought sensitivity and supports integrated modeling approaches for evaluating ecosystem resilience and sustainable management in arid mountain regions.

China↗

Sorghum stem aerenchyma formation is regulated by SbNAC_D during internode development

Abstract Sorghum bicolor is a drought‐resilient C4 grass used for production of grain, forage, sugar, and biomass. Sorghum genotypes capable of accumulating high levels of stem sucrose have solid stems that contain low levels of aerenchyma. The D ‐locus on SBI 06 modulates the extent of aerenchyma formation in sorghum stems and leaf midribs. A QTL aligned with this locus was identified and fine‐mapped in populations derived from BT x623* IS 320c, BT x623*R07007, and BT x623*Standard broomcorn. Analysis of coding polymorphisms in the fine‐mapped D ‐locus showed that genotypes that accumulate low levels of aerenchyma encode a truncated NAC transcription factor (Sobic.006G147400, SbNAC_d1 ), whereas parental lines that accumulate higher levels of stem aerenchyma encode full‐length NAC TF s ( SbNAC‐D ). During vegetative stem development, aerenchyma levels are low in nonelongated stem internodes, internode growing zones, and nodes. Aerenchyma levels increase in recently elongated internodes starting at the top of the internode near the center of the stem. SbNAC_D was expressed at low levels in nonelongated internodes and internode growing zones and at higher levels in regions of stem internodes that form aerenchyma. SbXCP1 , a gene encoding a cysteine protease involved in programmed cell death, was induced in SbNAC_D genotypes in parallel with aerenchyma formation in sorghum stems but not in SbNAC_d1 genotypes. Several sweet sorghum genotypes encode the recessive SbNAC_d1 allele and have low levels of stem aerenchyma. Based on these results, we propose that SbNAC_D is the D ‐gene identified by Hilton (1916) and that allelic variation in SbNAC_D modulates the extent of aerenchyma formation in sorghum stems.

59 BASIC BIOLOGICAL SCIENCES↗

Characteristics and performance of the first commercial multileaf collimator for a robotic radiosurgery system

Purpose: The “InCise™ multileaf-collimator (MLC)” is the first commercial MLC to be mounted on a robotic SRS/SBRT platform (CyberKnife). The authors assessed characteristics and performance of this novel device in a preclinical five months test period. Methods: Commissioning beam data were acquired with unshielded diodes. EBT3 radiochromic films were employed for measurement of transmission, leaf/bank position accuracy (garden fence) before and after exercising the MLC, for end-to-end testing and further characterization of the beam. The robot workspace with MLC was assessed analytically by transformation to an Euler geometry (“plane,” “gantry,” and “collimator” angles) and by measuring pointing accuracy at each node. Stability over time was evaluated in picket fence and adapted Winston–Lutz tests (AQA). Results: Beam penumbrae (80%–20%, with 100% = 2 × dose at inflection point for field sizes ≥ 50 × 50 mm{sup 2}) were 2.2–3.7 mm for square fields in reference condition (source-axis-distance 800 mm, depth 15 mm) and depended on field size and off-axis position. Transmission and leakage did not exceed 0.5%. Accessible clinical workspace with MLC covered non-coplanar gantry angles of [−113°; +112°] and collimator angles of [−100°; +107°], with an average robot pointing accuracy of 0.12 ± 0.09 mm. For vertical beams, garden fence tests exhibited an average leaf positioning error of ≤0.2 mm, which increased by 0.25 and 0.30 mm (banks X1 and X2) with leaves traveling parallel to gravity. After execution of a leaf motion stress routine, garden fence tests showed slightly increased jaggedness and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.38 ± 0.05 mm in nine end-to-end tests. Picket fence and AQA tests displayed stable results over the test period. Conclusions: The InCise™ MLC for CyberKnife showed high accuracy and adequate characteristics for SRS/SBRT applications. MLC performance after exercise demands specific quality assurance measures.

60 APPLIED LIFE SCIENCES↗

SU-F-T-437: 3 Field VMAT Technique for Irradiation of Large Pelvic Tumors

Purpose: VMAT treatment planning for large pelvic volume irradiation could be suboptimal due to inability of Varian linac to split MLC carriage during VMAT delivery for fields larger than 14.5cm in X direction (direction of leaf motion). We compare the dosimetry between 3 VMAT planning techniques, two 2-arc field techniques and a 3-arc field technique: a) two small in X direction (less than 14.5cm) arc fields, complementing each other to cover the whole lateral extent of target during gantry rotation, b) two large arc fields, each covering the targets completely during the rotation, c) a 3 field technique with 2 small in X direction arcs and 1 large field covering whole target. Methods: 5 GYN cancer patients were selected to evaluate the 3 VMAT planning techniques. Treatment plans were generated using Varian Eclipse (ver. 11) TPS. Dose painting technique was used to deliver 5300 cGy to primary target and 4500 cGy to pelvic/abdominal node target. All the plans were normalized so that the prescription dose of 5300 cGy covered 95% of primary target volume. PTV and critical structures DVH curves were compared to evaluate all 3 planning techniques. Results: The dosimetric differences between the two 2-arc techniques were minor. The small field 2-arc technique showed a colder hot spot (0.4% averaged), while variations in maximum doses to critical structures were statistically nonsignificant (under 1.3%). In comparison, the 3-field technique demonstrated a colder hot spot (1.1% less, 105.8% averaged), and better sparing of critical structures. The maximum doses to larger bowel, small bowel and gluteal fold were 3% less, cord/cauda sparing was 4.2% better, and bladder maximum dose was 4.6% less. The differences in maximum doses to stomach and rectum were statistically nonsignificant. Conclusion: 3-arc VMAT technique for large field irradiation of pelvis demonstrates dosimetric advantages compared to 2-arc VMAT techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-11: A Dosimetric Comparison of Robotic Prostatic Radiosugery Using Multi- Leaf Collimation Vs Circular Collimators

Purpose: The study compared the dosimetry plans of Stereotatic Body Radiotherapy (SBRT) prostate cancer patients using the M6 Cyberknife with Multi-leaf Collimation (MLC) compared with the plans using G4 Cyberknife with circular collimators. Methods: Eight previously treated prostate cancer patients' SBRT plans using circular collimators, designed with Multiplan v3.5.3, were used as a benchmark. The CT, contours and the optimization scripts were imported into Multiplan v5.0 system and replanned with MLC. The same planning objectives were used: more than 95% of PTV received 36.25Gy, 90% of prostate received 40Gy and maximum dose <45Gy, in five fractions. For organs at risk, less than 1cc of rectum received 36Gy and less than 10cc of bladder received 37Gy. Plans were evaluated on parameters derived from dose volume. The beam number, MU and delivery time were recorded to compare the treatment efficiency. Results: The mean CTV volume was 41.3cc (27.5∼57.6cc) and mean PTV volume was 76.77cc (59.1∼99.7cc). The mean PTV coverage was comparable between MLC (98.87%) and cone (98.74%). MLC plans had a slightly more favorable homogeneity index (1.22) and conformity index (1.17), than the cone (1.24 and 1.15). The mean rectum volume of 36 Gy (0.52cc) of MLC plans was slightly larger than cone (0.38cc) and the mean bladder volume of 37 Gy was smaller in MLC (1.82cc) than in cone plans (3.09cc). The mean number of nodes and beams were 65.9 and 80.5 in MLC vs 65.9 and 203.6 in cone. The mean MUs were significantly less for MLC plans (24,228MUs) than cone (32,347MUs). The total delivery time (which included 5 minutes for setup) was less, 29.6min (26∼32min) for MLC vs 45min (35∼55min) for cone. Conclusion: While the differences in the dosimetry between the MLC and circular collimator plans were rather minor, the MLC plans were much more efficient and required significantly less treatment time.

60 APPLIED LIFE SCIENCES↗

Tailored polyMOFs for ion transport in lithium-based battery electrolyte

Owing to their low flammability, solid-state and quasi-solid-state electrolytes are safer alternatives to liquid organic electrolytes for energy storage applications. Metal–organic frameworks (MOFs), with facile functional tunability, long-range order, and rich host–guest interactions, have been implemented as electrolyte materials in a wide range of energy storage applications. In this work, we investigate a class of MOFs called polyMOFs as quasi-solid-state electrolyte materials. Unlike MOF–polymer composites, which are physical mixtures of MOF particles and polymers, polyMOFs are composed of polymeric linkers and metal ion nodes that self-assembled into crystalline and porous framework materials. PolyMOFs thus marry the ionic transport properties of liquid electrolyte and polymers with the synthetic versatility and host–guest interactions of MOFs. We demonstrate that the functionality of the polymer backbone of the polyMOF linker can improve room-temperature ion transport in the material. The polyMOF based on poly(ethylene glycol) (PEG) exhibits greater ionic conductivity, lithium transference number, and lower activation energy than its polyethylene (PE) analog. Supported by solid-state 7 Li nuclear magnetic resonance spectroscopy, we propose these improvements are due to stronger coordination of Li + to oxide sites in PEG, allowing for dissociation of Li and its associated anion. DFT studies further reveal that the confined solvent molecule mediates Li + transport in PEG-functionalized UiO-66 via a metastable adsorption and hopping mechanism. This work lies at the interface of inorganic and polymer electrolytes, unveiling fundamental insights into the design of next-generation ion conductive materials for energy technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗