The Use of Pristine and Intercalated Graphite Fiber Composites as Buss Bars in Lead-Acid Batteries

This study was conducted as a part of the Firefly Energy Space Act Agreement project to investigate the possible use of composite materials in lead acid batteries. Specifically, it examined the use of intercalated graphite composites as buss bars. Currently, buss bars of these batteries are made of lead, a material that is problematic for several reasons. Over time, the lead is subject to both corrosion at the positive plate and sulfation at the negative plate, resulting in decreased battery life. In addition, the weight and size of the lead buss bars make for a heavy and cumbersome battery that is undesirable. Functionality and practicality of lead buss bars is adequate at best; consequently, investigation of more efficient composite materials would be advantageous. Practically speaking, graphite composites have a low density that is nearly one fourth that of its lead counterpart. A battery made of less dense materials would be more attractive to the consumer and the producer because it would be light and convenient. More importantly, low weight would be especially beneficial because it would result in greater overall power density of the battery. In addition to power density, use of graphite composite materials can also increase the life of the battery. From a functional standpoint, corrosion and sulfation at the positive and negative plates are major obstacles when considering how to extend battery life. Neither of these reactions are a factor when graphite composites replace lead parts because graphite is chemically non-reactive with the electrolyte within the battery. Without the problem of corrosion or sulfation, battery life expectancy can be almost doubled. The replacement of lead battery parts with composite materials is also more environmentally favorable because of easy disposal of organic materials. For this study, both pristine and bromine intercalated single-ply graphite fiber composites were created. The composites were fabricated in such a way as to facilitate their use in a 3" x 1/2" buss bar test cell. The prime objective of this investigation was to examine the effectiveness of a variety of graphite composite materials to act as buss bars and carry the current to and from the positive and negative battery plates. This energy transfer can be maximized by use of materials with high conductivity to minimize the buss resistance. Electrical conductivity of composites was measured using both a contactless eddy current probe and a four point measurement. In addition, the stability of these materials at battery-use conditions was characterized.

Opaluch, Amanda M.↗

Chopper-controlled discharge life cycling studies on lead-acid batteries

State-of-the-art 6 volt lead-acid golf car batteries were tested. A daily charge/discharge cycling to failure points under various chopper controlled pulsed dc and continuous current load conditions was undertaken. The cycle life and failure modes were investigated for depth of discharge, average current chopper frequency, and chopper duty cycle. It is shown that battery life is primarily and inversely related to depth of discharge and discharge current. Failure mode is characterized by a gradual capacity loss with consistent evidence of cell element aging.

Kraml, J. J.↗

A new lead-acid battery for high pulse power applications

The development of new electronically conductive materials which can withstand the environment of the positive plates has made possible the construction of a high pulse power sealed bipolar lead-acid battery. The new battery is described and its advantages over other electrochemical systems are outlined. Performance projections show that the peak specific power of the battery can be as high as 90 kW/kg, and that a specific power of 5 kW/kg can be sustained over several thousand pulses.

Rowlette, J. J.↗

Fundamental benchmarking of the discharge properties of negative electrodes in lead acid batteries

The unprecedented scale of energy storage deployment needed to allow high penetration of intermittent renewable energy sources into the electrical grid places significant economic cost and performance targets on battery technologies. Lead batteries, owing to their highly abundant and inexpensive raw materials, can be considered an important solution to grid storage as long as they achieve high material utilization, fast recharge rates, and long cycle life. To address the limitations in material utilization, we need to revisit the electrochemical processes during the discharge step and answer the following question: what are the fundamental limits of the discharge reaction? In this work we discuss how well-defined lead metal surfaces with nanometer scale roughness allow us to resolve the accessible discharge capacity for both faradaic and non-faradaic processes as a function of electrolyte concentration and in the presence of traditional additives. The direct connection between PbSO 4 layer morphology and discharge rates gives us important insights on the mechanism of discharge as related to the dissolution and passivation events. In conclusion, this work sets the stage for reimagining the design of lead batteries with implications to grid storage applications.

25 ENERGY STORAGE↗

Response of lead-acid batteries to chopper-controlled discharge: Preliminary results

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses up to 25 percent compared to constant current discharges at the same average discharge current of 100 amperes. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-ampere pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

Response of lead-acid batteries to chopper-controlled discharge

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses at up to 25 percent compared to constant current discharges at the same average discharge current of 100 A. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-A pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

Response of lead-acid batteries to chopper-controlled discharge

The results of tests on an electric vehicle battery, using a simulated electric vehicle chopper-speed controller, show energy output losses up to 25 percent compared to constant current discharges at the same average current of 100 A. However, an energy output increase of 22 percent is noticed at the 200 A average level and 44 percent increase at the 300 A level using pulse discharging. Because of these complex results, electric vehicle battery/speed controller interactions must be considered in vehicle design.

Cataldo, R. L.↗

Electric and hybrid vehicles charge efficiency tests of ESB EV-106 lead acid batteries

Charge efficiencies were determined by measurements made under widely differing conditions of temperature, charge procedure, and battery age. The measurements were used to optimize charge procedures and to evaluate the concept of a modified, coulometric state of charge indicator. Charge efficiency determinations were made by measuring gassing rates and oxygen fractions. A novel, positive displacement gas flow meter which proved to be both simple and highly accurate is described and illustrated.

Rowlette, J. J.↗

Characterization, performance, and prediction of a lead-acid battery under simulated electric vehicle driving requirements

A state-of-the-art 6-V battery module in current use by the electric vehicle industry was tested at the NASA Lewis Research Center to determine its performance characteristics under the SAE J227a driving schedules B, C, and D. The primary objective of the tests was to determine the effects of periods of recuperation and long and short periods of electrical regeneration in improving the performance of the battery module and hence extendng the vehicle range. A secondary objective was to formulate a computer program that would predict the performance of this battery module for the above driving schedules. The results show excellent correlation between the laboratory tests and predicted results. The predicted performance compared with laboratory tests was within +2.4 to -3.7 percent for the D schedule, +0.5 to -7.1 percent for the C schedule, and better than -11.4 percent for the B schedule.

Ewashinka, J. G.↗

Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures

Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.

Chapman, P.↗

Bipolar lead-acid batteries for electrical actuation applications

This document presents in viewgraph format information on bipolar battery development at Johnson Controls, Incorporated. The organization structure, goals, progress to date, future plans, and battery parameters and electrical properties are given.

Pierce, Douglas C.↗

Lead-acid battery

A sealed, low maintenance battery (10, 100) is formed of a casing (14, 102) having a sealed lid (12, 104) enclosing cell compartments (22, 110) formed by walls (24, 132). The cells comprise a stack (26) of horizontally disposed negative active plates (30) and positive active plates (28) interspersed with porous, resilient separator sheets (30). Each plate has a set of evenly spaced tigs (40, 41) disposed on one side thereof; like polarity tigs being disposed on one side and opposite polarity tigs on the other. Columns of tigs are electrically and mechanically joined by vertical bus bars (46). The bus bars contain outwardly projecting arms (56) of opposite polarity which are electrically joined at each partition wall (24) to electrically connect the cells in series. The stack is compressed by biasing means such as resilient pad (58) attached to the lid or by joining the tigs (52) to the post (48) at a distance less than the thickness of the mat (124). The end bus bars (46) are joined to straps (60, 62) which connect to the terminals (16, 18). The negative plates contain more capacity than the positive plates and the starved electrolyte imbibed in the separator sheets permits pressurized operation during which oxygen diffuses through the separator sheet to the negative plate where it recombines. Excess pressure is relieved through the vent and pressure relief valve (20).

Edwards, Dean B.↗

Energy Storage Grand Challenge: Energy Storage Market Report

As part of the Department of Energy's (DOE) Energy Storage Grand Challenge (ESGC), DOE intends to synthesize and disseminate best available energy storage data, information, and analysis to inform decision-making and accelerate technology adoption. The ESGC Roadmap provides options for addressing technology development, commercialization, manufacturing, valuation, and workforce challenges to position the United States for global leadership in the energy storage technologies of the future. This report provides a baseline understanding of the numerous, dynamic energy storage markets that fall within the scope of the ESGC via an integrated presentation of deployment, investment, and manufacturing data from the best, publicly-available sources. This report covers the following energy storage technologies: lithium ion batteries, lead acid batteries, pumped storage hydropower, comrpessed air energy storage, redox flow batteries, hydrogen, building thermal energy storage, and select long duration energy storage technologies. Not all energy storage technologies and markets could be addressed in this report. Due to the wide array of energy technologies, market niches, and data availability issues, this market report only included a select group of technologies. For example, thermal energy storage technologies are very broadly defined and cover a wide range of potential markets, technology readiness levels, and primary energy sources. In other areas, data scarcity necessitates a greater understanding of future applications and emerging science. Future efforts will update data presented in this report and be expanded to include other energy storage technologies. This data-driven assessment of the current status of energy storage markets is essential to track progress toward the goals described in the Energy Storage Grand Challenge and inform the decision-making of a broad range of stakeholders. At the same time, gaps identified through the development of this report can point to areas where further data collection and analysis could provide an even greater level of understanding of the full range of markets and technologies. Finally, numerous complementary analyses are planned, underway, or completed that will provide a deeper understanding of the specific technologies and markets covered at a high-level in this report.

25 ENERGY STORAGE↗

An Evaluation of Energy Storage Cost and Performance Characteristics

The energy storage industry continues to expand globally as costs continue to fall and opportunities in consumer, transportation and grid applications are defined. As the rapid evolution of the industry continues, it has become increasingly important to understand how varying technologies compare in terms of cost and performance. This paper defines and evaluates cost and performance parameters of six battery energy storage technologies (BESS) - lithium-ion batteries, lead-acid batteries, redox flow batteries, sodium-sulfur batteries, sodium metal halide batteries, and zinc-hybrid cathode batteries - four non-BESS storage technologies - pumped storage hydropower, flywheels, compressed air energy storage, and ultracapacitors - and combustion turbines. Cost and performance information was compiled based on an extensive literature review, conversations with vendors and stakeholders, and costs of systems procured at sites across the United States. Detailed cost and performance estimates are presented for 2018 and projected out to 2025. Annualized costs were also calculated for each technology.

Mongird, Kendall↗

Power Sources Conference, 29th, Atlantic City, NJ, June 9-12, 1980, Proceedings

Fuel systems are considered along with thermal batteries, primary batteries, lithium primary batteries, lithium/sulfur dioxide primary batteries, lithium/oxychloride primary batteries, high temperature secondary batteries, advanced secondary batteries, and nickel secondary batteries. Attention is given to a Ni-Fe battery with gas recombination device and state-of-charge indication, the development of the nickel-iron battery system for electric vehicle propulsion, improved lead-acid batteries, the behavior of the lead-acid batteries used to start the military vehicles at low temperatures, a life cycle energy analysis of the lead-acid battery, and the anodic corrosion of fiber reinforced lead composites for use in lead-acid submarine batteries. A description is presented of the key physical characteristics for predicting Zr powder burn times, the production of zirconium metal powder for rapid rise time thermal battery application, and high rate lithium-iron disulfide batteries.

Source record↗