Engineering PapersSearch

SEARCH · Engineering Papers

Results for “lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental longitudinal emittance manipulation using laser-based photoionization in the Fermilab Linac

A series of simulations and beam studies were conducted at Fermilab’s linear accelerator to evaluate the effectiveness of longitudinal emittance control via laser-induced photoionization. While similar laser techniques have been employed at Fermilab to enhance injection and extraction efficiency into the Booster, the work presented here focuses on extending these methods to bunch-by-bunch manipulation. This approach utilizes fine-scale correction of the H- bunches’ longitudinal spatial distribution. In theory, loosely confined particles in longitudinal phase space contribute to emittance growth during acceleration. By selectively removing these outlying particles through laser scraping (H- + γ → H + e-), this growth can be reduced. This report presents experimental results from both symmetric and asymmetric longitudinal scraping of H⁻ bunches in the Fermilab linac, which were subsequently injected into Booster, and evaluates the broader applicability of this method for future high-intensity accelerator operations.

Landon, Parker [Boston U.; Fermilab]

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

An Investigation of Oxides of Tantalum Produced by Pulsed Laser Ablation and Continuous Wave Laser Heating

Recent progress has seen multiple Ta 2 O 5 polymorphs generated by different synthesis techniques. However, discrepancies arise when these polymorphs are produced in widely varying thermodynamic conditions and characterized using different techniques. This work aimed to characterize and compare Ta 2 O 5 particles formed at high and low temperatures using nanosecond pulsed laser ablation (PLA) and continuous wave (CW) laser heating of a local area of tantalum in either air or an 18 O 2 atmosphere. Scanning electron microscopy (SEM) and Raman spectroscopy of the micrometer-sized particles generated by PLA were consistent with either a localized amorphous Ta 2 O 5 phase or a similar, but not identical, crystalline β-Ta 2 O 5 phase. The Raman spectrum of the material formed at the point of CW laser impingement was in good agreement with the previously established ceramic “H-Ta 2 O 5 ” phase. TEM and electron diffraction analysis of these particles indicated the phase structure matched an oxygen-vacated superstructure of monoclinic H-Ta 2 O 5 . Further from the point of laser impingement, CW heating produced particles with a Raman spectrum that matched β-Ta 2 O 5 . We confirmed that the high-temperature ceramic phase characterized in previous work by Raman spectroscopy was the same monoclinic phase characterized in different work by TEM and could be produced by direct laser heating of metal in air.

36 MATERIALS SCIENCE

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En

Particle-in-cell simulation of laser wakefield accelerators with oblique lasers in quasicylindrical geometry

In the studies of optical injections in laser or beam-driven wakefield accelerators, there is a frequent demand for using obliquely propagating assistant lasers in particle-in-cell simulations. In conventional methods, this is only possible in either two- or three-dimensional Cartesian geometries, which have the drawbacks of either lack of fidelity for the actual situation or requiring a huge amount of computational resources. In this work, we develop a new method that uses an expression-defined oblique laser field to simulate such situations in quasicylindrical geometry particle-in-cell simulations, having the advantages of both maintaining good fidelity and saving computational resources. As an example, we use this method in the scissor-cross ionization injection scheme for the optimization of the injected beam quality. This method is widely applicable to particle injections with assistant lasers in wakefield accelerators, as long as the assistant lasers only influence the injected particles during the injection process. Published by the American Physical Society 2025

Ma, Minghao (ORCID:0009000602317775)

Pulse duration dependent effects of ultrafast laser induced damage on a 1030 nm multi-layer dielectric mirror for high repetition rate, high average power laser systems

High repetition rate, high peak, and average power laser systems are crucial for next-generation particle accelerators, inertial confinement fusion, and secondary particle sources. These applications demand durable laser optics, particularly interference coatings on optics lasting millions of shots at high fluence. This study focuses on designing, testing, and simulating multi-layer dielectric (MLD) mirrors for pulse durations of 260 fs, 77 fs, and 25 fs at 1030 nm wavelength and 45-degree incidence angle with p -polarization. S-on-1 laser-induced damage thresholds (LIDT) for varying pulse numbers were determined, with single-shot LIDT values of 0.98 Jcm -2 , 1.63 Jcm -2 , and 2.3 Jcm -2 for 25 fs, 77 fs, and 260 fs respectively. A strong correlation between blister shape and local fluence was observed, implying that the layer expansion in a blister depends on local fluence. We have also examined mechanisms responsible for laser-induced stress generation and energy release rates in blister formation. Damage mechanisms are further explored by finite-difference time-domain (FDTD) simulations, incorporating Keldysh strong field ionization, whose predictions were in excellent agreement with the onset of damage determined experimentally. These findings offer insights for enhancing MLD coating technology, promising more efficient and resilient laser systems for diverse scientific and industrial applications.

Noor, Mohamed Yaseen (ORCID:000000021036644X)

Improved laser-plasma accelerator stability via high-bandwidth longitudinal focal position stabilization of a 100 TW-class laser system

Laser-plasma accelerators (LPAs) offer an attractive alternative to conventional accelerators for the development of compact electron sources and next-generation light sources. Due to orders-of-magnitude larger accelerating gradients, LPAs enable the acceleration of high-brightness electron beams to ultrarelativistic energies in millimeter- to centimeter-scale distances. However, LPA stability is limited by shot-to-shot fluctuations of the driving laser system. Specifically, fluctuations in the final-focus longitudinal position result in correlated instability in LPA electron beam qualities, including total beam charge, average beam energy, and energy spread. We demonstrate active stabilization of the longitudinal focal position for a 100 TW-class laser system. This repetition-rate scalable stabilization system leverages noninvasive wave front monitoring of a copropagating, unamplified kHz pulse train to guide corrective adjustments to the focal position of a 1 Hz amplified drive laser via an upstream telescope on millisecond timescales. In this demonstration, the approach limits standard deviation fluctuations of the amplified drive beam’s longitudinal focal position to ±0.22⁢ mm (representing at least a 53% reduction), achieved with a correction bandwidth that reaches the Nyquist frequency limit. Consequently, we observe marked improvements in both long-term and shot-to-shot LPA stability in terms of charge and spectrum.

Beam control

Over 8 hours of continuous operation of a free-electron laser driven by a laser-plasma accelerator

Since the emergence of laser-plasma accelerators (LPAs), substantial work has been dedicated to using LPAs to drive free-electron lasers (FELs) for a broad range of applications. Despite recent breakthroughs, which have proven the fundamental feasibility of operating FELs with an LPA source, stable FEL operation over multiple hours without operator input had yet to be achieved. In this work, we report significant improvements to the stability of a hundred terawatt laser system, resulting in successful demonstration of reliable, long-term operation of an LPA-driven FEL in the self-amplified spontaneous emission (SASE) regime at 420 nm. The LPA source delivered 100 MeV electron beams at 1 Hz with high stability over more than 10 h, enabling over 8 h of continuous FEL operation without operator input. The acquired data were subsequently used to investigate correlations between the measured undulator radiation and parameters of the drive laser, plasma source, and electron beam. The revealed connections between LPA and FEL performance gave important additional insights into ways to further improve and stabilize the system, thus demonstrating the capability of our setup to serve as a powerful platform for future studies of LPA-driven FEL operation. The one-of-a-kind integration of multiple stabilization concepts onto the LPA facility discussed in this manuscript yielded significant accelerator and light source improvements (with residual correlations suggesting even more is possible), which will positively impact LPA applications at large.

Kohrell, Finn [Lawrence Berkeley National Laborato

Controlling mechanical properties of laser powder bed fused AlSi10Mg through manipulation of laser scan rotation

The microstructure and mechanical properties of laser powder bed fused (LPBF) AlSi10Mg alloys can be controlled by many processing parameters. This study focuses on the scan rotation angle, α, between adjacent layers, and establishes the relationship between α and tensile behavior of the as-built LPBF-processed AlSi10Mg alloy. Near-full density cubic coupons were manufactured using the same processing parameters but with systematic variation of α from 0° to 90°. Microscopic observations and X-ray diffraction analysis showed that differences among various coupons mainly include orientations of the melt pools with respect to the build direction and development of the crystallographic texture. The α=0° coupon and α=30° coupon showed the highest and lowest texture index, although the overall crystallographic texture was mild. Tensile specimens were manufactured horizontally and vertically using either α=0° or α=30°, but with various first layer laser direction with respect to the build plate. Notably, the α=0° specimen that was tested along the laser scan direction showed the largest yield strength (283 MPa) and highest tensile ductility (10.1 %). Quantitative image analysis and fractography were performed on all specimens. Results showed that the melt pool orientation with respect to the tensile direction affected the tensile behavior across the different specimens. This was closely related to the localized strain distribution within the melt pool and along the melt pool boundary for the different melt pool orientations observed. Further, these results demonstrate that the laser scan rotation angle between layers can be used to fine tune the mechanical properties of LPBF AlSi10Mg alloy.

36 MATERIALS SCIENCE

Robust direct laser acceleration of electrons with flying-focus laser pulses

Direct laser acceleration (DLA) offers a compact source of high-charge, energetic electrons for generating secondary radiation or neutrons. While DLA in high-density plasma optimizes the energy transfer from a laser pulse to electrons, it exacerbates nonlinear propagation effects, such as filamentation, that can disrupt the acceleration process. Here, we show that superluminal flying-focus pulses (FFPs) mitigate nonlinear propagation, thereby enhancing the number of high-energy electrons and resulting x-ray yield. Three-dimensional particle-in-cell simulations show that, compared to a Gaussian pulse of equal energy (1 J) and intensity (2 × 10 20 W/cm 2 ), an FFP produces 80 × more electrons above 100 MeV, increases the electron cutoff energy by 20%, triples the high-energy x-ray yield, and improves x-ray collimation. These results illustrate the ability of spatiotemporally structured laser pulses to provide additional control in the highly nonlinear, relativistic regime of laser-plasma interactions.

Laser-produced plasmas

Laser wavelength dependence of particle acceleration mechanisms in high intensity laser–solid density plasma interactions

We investigate the generation of relativistic electrons and the subsequent ion acceleration due to target-normal sheath acceleration when ultra-intense (⁠ I > 10 18 W/cm 2 ⁠) short pulse (⁠ τ L < 10ps⁠) lasers are incident onto solid density targets as laser wavelength is varied. Scaling laws for the hot electron temperature, T hot ⁠, and the maximum ion energy, E max ⁠, are recast as a function of laser wavelength. These predictions are compared to results from particle-in-cell computer simulations in a variety of geometries, including cases where realistic plasma density profiles as determined by a radiation hydrodynamics code are used. It is found that the wavelength dependence observed in simulation is less pronounced than what is predicted from the well-established scaling laws. An assessment of how switching to longer laser wavelengths, specifically 2 μm Tm:YLF technology, would impact current high energy density science applications and diagnostics is made.

Electromagnetism

Study of ablation and shock generation across three orders of magnitude of laser intensity with 100 ps laser pulses

The laser ablation and subsequent shock generation in solid targets plays an important role in a variety of research topics from equation of state models for materials to inertial confinement fusion. One of the long-standing issues is the knowledge of ablation depth in the picosecond time regime. Here, we report on a direct technique for determining the ablation depth in aluminum using x-ray diffraction data from Linac Coherent Light Source at the Stanford Linear Accelerator Center. This technique gives a direct measurement of the shock wave propagation in the bulk target, enabling an ability to discern early timescale physics from late timescale effects not available in postmortem analysis. We find that the ablation depths only vary by 0.2 μm across three orders of magnitude of laser intensity, while the pressure increased by a factor of 10 following a square root dependence on laser pulse energy. We further observe that the ablation depth in this intensity range (10 11 –10 13 W/cm 2 in intensity, corresponding to 0.8–80 J/cm 2 in fluence) cannot be modeled by a universal scaling law, given the complexity of the mechanisms governing laser ablation in this intensity regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications

Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ~ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

2025 Peregrine in-situ monitoring and training dataset for laser powder bed fusion and binder jet printers

Peregrine, a software tool developed at Oak Ridge National Laboratory (ORNL), was used to collect and analyze in-situ monitoring (ISM) data from a Concept Laser M2 (Colibrium Additive) laser powder bed fusion (L-PBF) printer and an ExOne Innovent (Desktop Metal) binder jet printer. Data for four builds (print jobs) were saved to HDF5 (high performance data) files for release. Additionally, process anomalies were annotated by the authors across 37 image stacks (i.e., print layers) and are also provided as HDF5 files.

36 MATERIALS SCIENCE

Prediction of laser beam spatial profiles in a high-energy laser facility by use of deep learning

We adapt the significant advances achieved recently in the field of generative artificial intelligence/machine-learning to laser performance modeling in multipass, high-energy laser systems with application to high-shot-rate facilities relevant to inertial fusion energy. Advantages of neural-network architectures include rapid prediction capability, data-driven processing, and the possibility to implement such architectures within future low-latency, low-power consumption photonic networks. Four models were investigated that differed in their generator loss functions and utilized the U-Net encoder/decoder architecture with either a reconstruction loss alone or combined with an adversarial network loss. We achieved inference times of 1.3 ms for a 256 × 256 pixel near-field beam with errors in predicted energy of the order of 1% over most of the energy range. It is shown that prediction errors are significantly reduced by ensemble averaging the models with different weight initializations. These results suggest that including the temporal dimension in such models may provide accurate, real-time spatiotemporal predictions of laser performance in high-shot-rate laser systems.

47 OTHER INSTRUMENTATION

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]

Imaging of dark line defect growth in high-power diode laser cavities using broadband near infrared light emission from the laser cavity

An in situ and nondestructive technique is developed to image the formation and evolution of dark line defects in the cavity of a high-power diode laser. Here, the technique uses broadband near infrared emission that originates in the laser's core layers and enables defects to be imaged with high spatial resolution through the substrate. In particular, it enables defect imaging through the substrate of shorter wavelength lasers, even when the substrate is opaque near the lasing wavelength. The evolution of dark line defects during aging is studied in several devices, with correlations established between the observed characteristics of defect growth and changes in device parameters such as optical power, operating wavelength, threshold current, and slope efficiency. Gradual degradation is found to be associated with dark line defects that slowly propagate from dark spots that are present in the device interior in its fresh (unaged) condition, rather than propagating from spots that are formed during aging, suggesting a strategy to screen fresh devices for expected reliability. This defect growth phenomenon is found to be particularly evident in the dark spots near the output facet.

47 OTHER INSTRUMENTATION