Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simultaneous broadband laser ranging and photonic Doppler velocimetry for dynamic compression experiments

A diagnostic was developed to simultaneously measure both the distance and velocity of rapidly moving surfaces in dynamic compression experiments, specifically non-planar experiments where integrating the velocity in one direction does not always give the material position accurately. The diagnostic is constructed mainly from fiber-optic telecommunications components. The distance measurement is based on a technique described by Xia and Zhang [Opt. Express 18, 4118 (2010)], which determines the target distance every 20 ns and is independent of the target speed. We have extended the full range of the diagnostic to several centimeters to allow its use in dynamic experiments, and we multiplexed it with a photonic Doppler velocimetry (PDV) system so that distance and velocity histories can be measured simultaneously using one fiber-optic probe. The diagnostic was demonstrated on a spinning square cylinder to show how integrating a PDV record can give an incorrect surface position and how the ranging diagnostic described here obtains it directly. The diagnostic was also tested on an explosive experiment where copper fragments and surface ejecta were identified in both the distance and velocity signals. We show how the distance measurements complement the velocity data. Potential applications are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Progress at the International Laser Ranging Service (ILRS)

The International Laser Ranging Service (ILRS) is experiencing significant growth. New stations are being built and brought into operation, expanding the spatial and temporal coverage of the Satellite Laser Ranging (SLR) observations. Some of these stations are multi-technique Core Sites that allow us to exploit the combined strengths of different geodetic space techniques. New satellites are strengthening the ILRS contribution to the International Terrestrial Reference Frame (ITRF), and expanding the spectrum of satellite applications supported by the ILRS. New analysis, modeling, and data processing techniques continue to improve the science products. New campaigns are continuing to expand SLR applications into relativity and the study of non-gravitational forces. The ILRS is currently participating in the Galileo for Science campaign (G4S_2.0 project), funded by the Italian Space Agency (ASI), which aims to perform a set of measurements in the field of gravitation with the Galileo satellites, taking advantage of the accuracy of the on-board atomic clocks and, in particular, of GSAT0201and GSAT0202 by exploiting their relatively high eccentricity (~0.16). New activities underway in Lunar Laser Ranging (LLR), with the imminent launch and deployment of the upcoming Next Generation Lunar Retroreflector - 1 (NGLR-1) to the lunar surface. Some new satellites supported by the ILRS are now exploring means of capturing Space Debris, while some ILRS stations run local laser ranging projects to track space debris, contributing to the maintenance of various data catalogs. Time transfer experiments are also expanding the application of laser ranging, linking two fully characterized optical clocks at different locations with SLR (Einstein Synchronization) providing measurements of height differences, demonstrating the feasibility of a physical height system. Two-way and one-way transponders activity has been underway since the LASSO experiment in the 1990’s. More experiments are underway or planned. Applications include time and frequency transfer and clock synchronization between ground and space, interplanetary laser ranging, and fundamental physics. This presentation will give an update on ILRS activities and the impact that these activities have had and will have on ILRS data products.

Lunar Laser Ranging↗

New progress of ranging technology at Wuhan Satellite Laser Ranging Station

A satellite laser ranging system with an accuracy of the level of centimeter has been successfully developed at the Institute of Seismology, State Seismological Bureau with the cooperation of the Institute of Geodesy and Geophysics, Chinese Academy of Science. With significant improvements on the base of the second generation SLR system developed in 1985, ranging accuracy of the new system has been upgraded from 15 cm to 3-4 cm. Measuring range has also been expanded, so that the ETALON satellite with an orbit height of 20,000 km launched by the former U.S.S.R. can now be tracked. Compared with the 2nd generation SLR system, the newly developed system has the following improvements. A Q modulated laser is replaced by a mode-locked YAG laser. The new device has a pulse width of 150 ps and a repetition rate of 1-4 pps. A quick response photomultiplier has been adopted as the receiver for echo; for example, the adoption of the MCP tube has obviously reduced the jitter error of the transit time and has improved the ranging accuracy. The whole system is controlled by an IBM PC/XT Computer to guide automatic tracking and measurement. It can carry out these functions for satellite orbit calculation, real-time tracking and adjusting, data acquisition and the preprocessed of observing data, etc. The automatization level and reliability of the observation have obviously improved.

Xia, Zhiz-Hong↗

Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

Laser altimeters measure the time of flight of the laser pulses to determine the range of the target. The simplest altimeter receiver consists of a photodetector followed by a leading edge detector. A time interval unit (TIU) measures the time from the transmitted laser pulse to the leading edge of the received pulse as it crosses a preset threshold. However, the ranging error of this simple detection scheme depends on the received, pulse amplitude, pulse shape, and the threshold. In practice, the pulse shape and the amplitude are determined by the target target characteristics which has to be assumed unknown prior to the measurement. The ranging error can be improved if one also measures the pulse width and use the average of the leading and trailing edges (half pulse width) as the pulse arrival time. The ranging error becomes independent of the received pulse amplitude and the pulse width as long as the pulse shape is symmetric. The pulse width also gives the slope of the target. The ultimate detection scheme is to digitize the received waveform and calculate the centroid as the pulse arrival time. The centroid detection always gives unbiased measurement even for asymmetric pulses. In this report, we analyze the laser altimeter ranging errors for these three detection schemes using the Mars Orbital Laser Altimeter (MOLA) as an example.

Davidson, Frederic M.↗

The solid state detector technology for picosecond laser ranging

We developed an all solid state laser ranging detector technology, which makes the goal of millimeter accuracy achievable. Our design and construction philosophy is to combine the techniques of single photon ranging, ultrashort laser pulses, and fast fixed threshold discrimination while avoiding any analog signal processing within the laser ranging chain. The all solid state laser ranging detector package consists of the START detector and the STOP solid state photon counting module. Both the detectors are working in an optically triggered avalanche switching regime. The optical signal is triggering an avalanche current buildup which results in the generation of a uniform, fast risetime output pulse.

Prochazka, Ivan↗

NASA ground-based and space-based laser ranging systems

The development of NASA laser ranging systems is discussed with reference to applications such as orbit determination, gravity-field studies, and analyses of polar motion, earth tides, and tectonic plate motion. Several laser ranging designs are described noting the first satellite laser ranging experiment, the Moblas II and III systems, and the laser ranging satellites presently in orbit. Primary error sources are identified as atmospheric delay, optical signal-to-noise ratios, the electron multiplier, time-interval measurements, and target noise. Plans for Shuttle-based laser ranging systems are reviewed noting simulation studies of 12-day Shuttle missions.

Fitzmaurice, M. W.↗

Location of Lunakhod 2 from laser ranging observations

Results of laser ranging attempts on Lunakhod 2 are presented. Laser ranging can only be accomplished at night, so only the straight-line distance between the end points of a daytime traverse can be determined. Uncertainties of positional determination are strongly dependent on the length of the tracking arc. The data, obtained in the first two lunar nights, are too sparse to yield reliable positional determinations. The results clearly illustrate the critical importance of a high-quality lunar ephemeris for the interpretation of sparse data.

Mulholland, J. D.↗

Extending Science from Lunar Laser Ranging

The Lunar Laser Ranging (LLR) experiment has accumulated 50 years of range data of improving accuracy from ground stations to the laser retroreflector arrays (LRAs) on the lunar surface. The upcoming decade offers several opportunities to break new ground in data precision through the deployment of the next generation of single corner-cube lunar retroreflectors and active laser transponders. This is likely to expand the LLR station network. Lunar dynamical models and analysis tools have the potential to improve and fully exploit the long temporal baseline and precision allowed by millimetric LLR data. Some of the model limitations are outlined for future efforts. Differential observation techniques will help mitigate some of the primary limiting factors and reach unprecedented accuracy. Such observations and techniques may enable the detection of several subtle signatures required to understand the dynamics of the Earth- Moon system and the deep lunar interior. LLR model improvements would impact multi- disciplinary fields that include lunar and planetary science, Earth science, fundamental physics, celestial mechanics and ephemerides.

Vishnu Viswanathan↗

Calibration of a single-point laser range finder and a camera

Laser and visual imagery have been broadly utilized in computer vision and mobile robotics applications because these sensors provide complementary information. Since the single-point laser range finder can provide depth information of a single pixel in the observed image, its price and size is very suitable for handheld devices or very lightweight robotic platforms. So the combination of a single-point laser range finder and a camera has become increasingly useful in recent report and industrial applications. In this paper, we propose two accurate calibration methods for determining the position and direction of the laser range finder relative to the camera. Furthermore, we can accomplish calibration even without observing the laser spot in camera image. We evaluate the two methods through experiments which demonstrate their efficiency and high reliability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed-laser ranging

Pulsed rubidium laser range measurements with delayed sweep oscilloscope, and with digital readout system

RUBY LASER↗

Satellite Laser Ranging operations

Satellite Laser Ranging (SLR) is currently providing precision orbit determination for measurements of: 1) Ocean surface topography from satellite borne radar altimetry, 2) Spatial and temporal variations of the gravity field, 3) Earth and ocean tides, 4) Plate tectonic and regional deformation, 5) Post-glacial uplift and subsidence, 6) Variations in the Earth's center-of-mass, and 7) Variations in Earth rotation. SLR also supports specialized programs in time transfer and classical geodetic positioning, and will soon provide precision ranging to support experiments in relativity.

Pearlman, Michael R.↗

Laser Ranging System

Laser system points and focuses TV camera. Ranger is modified stock distance-measuring unit mounted on and electrically connected to television camera. Effective over target range of 3 to 500 ft. (approximately 1 to 150m). Developed for television monitoring of nearby objects from Space Shuttle. Super-imposes range and range-rate (speed of approach or recession) data on television image of target. Principle adaptable to applications such as proximity warning and robot control.

Russell, J. K.↗

Spaceborne laser ranging from EOS

High precision laser ranging measurements from an Earth Observing System (EOS) platform would provide data for conducting a variety of basic geoscience investigations. For example, range data to retroreflectors arranged in grids located at tectonic plate boundaries could be used to study the spatial and temporal distribution of the crustal movements associated with stress accumulation and release in an earthquake cycle. The Geodynamics Laser Ranging System (GLRS) is a proposed facility instrument for EOS that can perform the ranging function as well as simple height-measurement altimetry over ice sheets. This instrument is the derivative of several generations of ground-based laser trackers and prototype laboratory systems. The Geoscience Laser Altimetry/Ranging System (GLARS) is an advanced laser ranging system which would provide higher accuracy ranging observations and detailed altimetric mapping of surface height distributions over land and ice sheets.

Cohen, Steven C.↗

Evaluation of a satellite laser ranging technique using pseudonoise code modulated laser diodes

Several types of Satellite Laser Ranging systems exist, operating with pulsed, high-energy lasers. The distance between a ground point and an orbiting satellite can be determined to within a few centimeters. A new technique substitutes pseudonoise code modulated laser diodes, which are much more compact, reliable and less costly, for the lasers now used. Since laser diode technology is only now achieving sufficiently powerful lasers, the capabilities of the new technique are investigated. Also examined are the effects of using an avalanche photodiode detector instead of a photomultiplier tube. The influence of noise terms (including background radiation, detector dark and thermal noise and speckle) that limit the system range and performance is evaluated.

Ball, Carolyn Kay↗

Earth rotation and polar motion from laser ranging to the moon and artificial satellites

Earth-based laser ranging to artificial satellites and to the moon is considered as a technique for monitoring the Earth's polar motion and diurnal rotation. The kinematics of Earth rotation as related to laser ranging is outlined. The current status of laser ranging as regards its measuring capabilities is reviewed. The relative merits of artificial satellite and lunar laser ranging are pointed out. It appears that multistation combined artificial satellite and lunar laser ranging is likely to ultimately meet a 0.002 arcseconds in pole position and 0.1 msec in UT1 daily precision requirement.

Aardoom, L.↗

Performance Analysis of the Spaceborne Laser Ranging System

The 'spaceborne laser ranging system' is a proposed short pulse laser on board an orbiting spacecraft. It measures the distances between the spacecraft and many laser retroreflectors (targets) deployed on the earth's surface. The precision of these range measurements was assumed to be about plus or minus 2 cm. These measurements were then used together with the orbital dynamics of the spacecraft to derive the intersite vector between the laser ground targets. The errors associated with this vector were on the order of 1 to 2 cm. The baseline distances determined range from 25 km to 1200 km. By repeating the measurements of the intersite vector, strain and strain rate errors were estimated. The realizable precision for intersite distance determination was estimated to be on the order of 0.5 cm at 300 km and about 1.5 cm at 1200 km. The corresponding inaccuracies for the intersite distances were larger, than is 1 cm and 3.5 cm respectively. The corresponding precision in the vertical direction was 1 cm and 3 cm.

Kahn, W. D.↗