Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “knee injury”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

21 records · Page 2

Determining the Importance of In-Flight Treadmill Running Capabilities for Maintaining Astronaut Health and Performance

BACKGROUND: Physical deconditioning induced via spaceflight is most effectively attenuated through in-flight exercise training. Throughout its evolution, NASA has implemented advancements to in-flight exercise countermeasures, culminating in the triad of devices currently used aboard the International Space Station (ISS): a treadmill (T2), cycle ergometer (CEVIS), and resistance exercise device (ARED). Despite high-quality exercise devices and prescriptions, many crewmembers experience reductions in both aerobic capacity (VO2peak pre-post mean change: -10%) and strength (knee isokinetic pre-post mean change: -15%). As NASA moves towards exploration missions, which will impose greater size, power, and time constraints on exercise systems in addition to physically demanding surface extravehicular activities (EVAs), providing robust capabilities to protect crew health and performance should be prioritized. OVERVIEW: Future missions to the Lunar and Martian surfaces will include EVAs requiring ambulation and greater physical exertion than those in Apollo missions. While the exercise device concepts planned for exploration missions include resistive and aerobic capabilities, they do not allow for ambulation. Specifically, the countermeasure planned for Artemis Lunar transit is a flywheel device, which provides both exercise modalities through a single resistive cable. While more robust than the flywheel, the devices planned for the Lunar orbital space station, and subsequent Mars habitats, will provide distinct aerobic and resistance modalities capable of achieving high intensities. However, these modalities do not include a treadmill. Recent research suggests that greater in-flight running intensity and volume attenuate decrements in aerobic capacity and strength; however, this has not been experimentally confirmed. The Exploration Exercise Treadmill Requirements study is currently underway, aiming to determine the effects of exercising without a treadmill on aerobic capacity, strength, bone density, and sensorimotor function during long-duration spaceflight. DISCUSSION: Providing running capabilities on future exploration missions may help to maintain astronaut physical ability, reduce injury, and promote health. Studies quantifying the effects of using exploration exercise devices are in progress, which will help provide critical recommendations on whether a treadmill is a necessary component of the in-flight training regime. This presentation will discuss the capabilities of exploration exercise devices and the potential implications of not having running capabilities during long-duration spaceflight.

Alyssa N Varanoske↗

Crashworthy Seats Would Afford Superior Protection

Seats to prevent or limit crash injuries to astronauts aboard the crew vehicle of the Orion spacecraft are undergoing development. The design of these seats incorporates and goes beyond crash-protection concepts embodied in prior spacecraft and racing-car seats to afford superior protection against impacts. Although the seats are designed to support astronauts in a recumbent, quasi-fetal posture that would likely not be suitable for non-spacecraft applications, parts of the design could be adapted to military and some civilian aircraft seats and to racing car seats to increase levels of protection. The main problem in designing any crashworthy seat is to provide full support of the occupant against anticipated crash and emergency-landing loads so as to safely limit motion, along any axis, of any part of the occupant s body relative to (1) any other part of the occupant s body, (2) the spacecraft or other vehicle, and (3) the seat itself. In the original Orion spacecraft application and in other applications that could easily be envisioned, the problem is complicated by severe limits on space available for the seat, a requirement to enable rapid egress by the occupant after a crash, and a requirement to provide for fitting of the seat to a wide range of sizes and shapes of a human body covered by a crash suit, space suit, or other protective garment. The problem is further complicated by other Orion-application-specific requirements that must be omitted here for the sake of brevity. To accommodate the wide range of crewmember body lengths within the limits on available space in the original Orion application, the design provides for taller crewmembers to pull their legs back closer toward their chests, while shorter crewmembers can allow their legs to stretch out further. The range of hip-support seat adjustments needed to effect this accommodation, as derived from NASA s Human Systems Integration Standard, was found to define a parabolic path along which the knees must be positioned. For a given occupant, the specific position along the path depends on the distance from the heel to the back of the knee. The application of the concept of parabolic adjustment of the hip-support structure caused the seat pan to also take on a parabolic shape, yielding the unanticipated additional benefit that the seat pan fits the occupant s buttocks and thighs more nearly conformally than do seat pans of prior design. This more nearly conformal fit effectively eliminates a void between the occupant s body and the seat pan, thereby helping to prevent what, in prior seat designs, was shifting of the occupant s body into that void during an impact.

Gohmert, Dustin↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗