Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isotope quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ecosystem consequences of a nitrogen-fixing proto-organelle

Microscale symbioses can be critical to ecosystem functions, but the mechanisms of these interactions in nature are often cryptic. Here, we use a combination of stable isotope imaging and tracing to reveal carbon (C) and nitrogen (N) exchanges among three symbiotic primary producers that fuel a salmon-bearing river food web. Bulk isotope analysis, nanoSIMS (secondary ion mass spectrometry) isotope imaging, and density centrifugation for quantitative stable isotope probing enabled quantification of organism-specific C- and N-fixation rates from the subcellular scale to the ecosystem. After winters with riverbed-scouring floods, the macroalga Cladophora glomerata uses nutrients in spring runoff to grow streamers up to 10 m long. During summer flow recession, riverine N concentrations wane and Cladophora becomes densely epiphytized by three species of Epithemia, diatoms with N-fixing endosymbionts (proto-organelles) descended from a free-living Crocosphaera cyanobacterium. Over summertime epiphyte succession on Cladophora, N-fixation rates increased as Epithemia spp. became dominant, Cladophora C-fixation declined to near zero, and Epithemia C-fixation increased. Carbon transfer to caddisflies grazing on Cladophora with high densities of Epithemia was 10-fold higher than C transfer to caddisflies grazing Cladophora with low Epithemia loads. In response to demand for N, Epithemia allocates high levels of newly fixed C to its endosymbiont. Consequently, these endosymbionts have the highest rates of C and N accumulation of any taxon in this tripartite symbiosis during the biologically productive season and can produce one of the highest areal rates of N-fixation reported in any river ecosystem.

Marks, Jane C. [Northern Arizona Univ., Flagstaff,↗

Systematic comparison of local approaches for isotopically nonstationary metabolic flux analysis

Quantification of reaction fluxes of metabolic networks can help us understand how the integration of different metabolic pathways determine cellular functions. Yet, intracellular fluxes cannot be measured directly but are estimated with metabolic flux analysis (MFA) that relies on the patterns of isotope labeling of metabolites in the network. For metabolic systems, typical for plants, where all potentially labeled atoms effectively have only one source atom pool, only isotopically nonstationary MFA can provide information about intracellular fluxes. There are several global approaches that implement MFA for an entire metabolic network and estimate, at once, a steady-state flux distribution for all reactions with identifiable fluxes in the network. In contrast, local approaches deal with estimation of fluxes for a subset of reactions, with smaller data demand for flux estimation. Here we present a systematic comparative review and benchmarking of the existing local approaches for isotopically nonstationary MFA. The comparison is conducted with respect to the required data and underlying computational problems solved on a synthetic network example. Furthermore, we benchmark the performance of these approaches in estimating fluxes for a subset of reactions using data obtained from the simulation of nitrogen fluxes in the Arabidopsis thaliana core metabolism. The findings pinpoint practical aspects that need to be considered when applying local approaches for flux estimation in large-scale plant metabolic networks.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of ambient gas on self-reversal in Li transitions relevant to isotopic analysis

Laser induced breakdown spectroscopy is a promising, rapid analysis method for the detection and quantification of Li and its isotopes needed in geochemical, nuclear, and energy storage applications. However, spectral broadening in laser produced plasmas, presence of fine and hyperfine structures, and self-reversal effects make Li isotopic analysis via laser induced breakdown spectroscopy challenging. The present study explores the influence of Ar, N 2 , and He ambient gases over the pressure range of 0.05 - 100 Torr on line broadening and self-reversal of the Li I transition with the greatest isotopic shift in the VIS spectral region (i.e., ≈670.8 nm, ≈15.8 pm isotopic shift). We perform spatially and temporally resolved optical emission spectroscopy of plasmas produced via laser ablation of LiAlO 2 substrates. Our results show that the self-reversal and linewidth is reduced at lower pressures for all gases, and using optimized plasma conditions with chemometric methods, the 6 Li/ 7 Li isotopic ratios can be predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Rapid Analytical Methodology for Chloride Molten Salt Reactor Safeguards and Process Monitoring

Technologies that enable near real-time isotopic analysis of advanced molten salt reactor (MSR) fuels are critically needed to safeguard these reactors, increase their operational efficiency, and enable their widespread deployment with confidence. We present a systematic approach to developing near real-time dissolution and chemical isolation of U, Pu, and major fission products from highly radioactive chloride molten salt samples. Chemical yields greater than 95% were observed for both uranium and the lanthanides. Interference reduction enabled the detection and quantification of key diagnostic isotopes (including 112Ag, 147Nd, and 153Sm) that were previously undetectable in the original sample. The results from this initial scoping study lay the foundation for the development of future automated systems that can enable cost-efficient, near-real time chemical separation and analysis of extremely highly radioactive molten salt samples.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Analysis of hydrogen and lithium isotopes using Laser-Induced Breakdown Spectroscopy

The detection and quantification of hydrogen (1,2,3H) and lithium (6,7Li) isotopes are critical to several energy and defense application areas, including hydrogen storage, nuclear forensics, and safeguards/non-proliferation. In this context, laser-induced breakdown spectroscopy (LIBS) is very promising and it comes with certain advantages such as rapid detection, and standoff capability. Although LIBS provides experimental simplicity and is capable of detecting all elements in the periodic table in any phase (solid, liquid, or gas), there exist certain challenges for isotopic analyses of H and Li due to spectral broadening, the presence of closely spaced fine and hyperfine structures, and line distortion effects (e.g., self-absorption and self-reversal) present in laser-produced plasmas. This article reports recent developments in H and Li isotopic analysis using LIBS, and existing challenges.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Considerations of Radiation-Hardened Electronics for Alpha Detectors in Molten Salt Reactors

Along with advanced generations of reactors quickly becoming reality, the need for instrumentation to provide reliable information for their safety and operation is also becoming relevant. Instrumentation-wise, molten salt reactors (MSRs) represent an especially challenging case in which detectors must survive extreme temperatures, high amounts of radiation, and a highly corrosive coolant. Adding to the complexity, tight material control and accounting must be maintained with any special nuclear material (SNM), a practice made more difficult by the nature of a loop of flowing fuel. Alpha spectroscopy offers a unique window into investigating the isotopic concentrations of actinides within just such a molten salt environment. The characteristic α emissions of specific actinide isotopes in the salt enable quantification of their concentrations. Semiconductor devices based on wide bandgap materials such as silicon carbide and gallium oxide can withstand the extreme temperatures within MSRs and offer good chemical stability with the corrosive salt. Collaborators at The Ohio State University are fabricating and testing a β gallium oxide α particle sensor that could identify actinide concentrations within the fuel salt to help improve the material control and accounting required for complicated system inherent to MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Global protein turnover quantification in Escherichia coli reveals cytoplasmic recycling under nitrogen limitation

Protein turnover is critical for proteostasis, but turnover quantification is challenging, and even in well-studied E. coli, proteome-wide measurements remain scarce. Here, we quantify the turnover rates of ~3200 E. coli proteins under 13 conditions by combining heavy isotope labeling with complement reporter ion quantification and find that cytoplasmic proteins are recycled when nitrogen is limited. We use knockout experiments to assign substrates to the known cytoplasmic ATP-dependent proteases. Surprisingly, none of these proteases are responsible for the observed cytoplasmic protein degradation in nitrogen limitation, suggesting that a major proteolysis pathway in E. coli remains to be discovered. Lastly, we show that protein degradation rates are generally independent of cell division rates. Thus, we present broadly applicable technology for protein turnover measurements and provide a rich resource for protein half-lives and protease substrates in E. coli, complementary to genomics data, that will allow researchers to study the control of proteostasis.

59 BASIC BIOLOGICAL SCIENCES↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Quantification of SARS-CoV-2 spike protein expression from mRNA vaccines using isotope dilution mass spectrometry

The advent of mRNA vaccine technology has been vital in rapidly creating and manufacturing COVID-19 vaccines at an industrial scale. To continue to accelerate this leading vaccine technology, an accurate method is needed to quantify antigens produced by the transfection of cells with a mRNA vaccine product. This will allow monitoring of protein expression during mRNA vaccine development and provide information on how changes to vaccine components affects the expression of the desired antigen. Developing novel approaches that allow for high-throughput screening of vaccines to detect changes in antigen production in cell culture prior to in vivo studies could aid vaccine development. Here, we have developed and optimized an isotope dilution mass spectrometry method to detect and quantify the spike protein expressed after transfection of baby hamster kidney cells with expired COVID-19 mRNA vaccines. Five peptides of the spike protein are simultaneously quantified and provide assurance that protein digestion in the region of the target peptides is complete since results between the five peptides had a relative standard deviation of less than 15 %. In addition, two housekeeping proteins, actin and GAPDH, are quantified in the same analytical run to account for any variation in cell growth within the experiment. IDMS allows a precise and accurate means to quantify protein expression by mammalian cells transfected with an mRNA vaccine.

60 APPLIED LIFE SCIENCES↗

Arabidopsis ABCG14 forms a homodimeric transporter for multiple cytokinins and mediates long-distance transport of isopentenyladenine-type cytokinins

Phytohormone cytokinins (CKs), primarily including trans-zeatin (tZ) and isopentenyladenine (iP) types, play critical roles in plant growth, development, and stress response. Long-distance transport of trans-zeatin (tZ)-type CKs has been well elucidated. However, long-distance transport of isopentenyladenine (iP)-type CKs remains unknown. Here, we demonstrated that the physiologically characterized ABC transporter AtABCG14 is also involved in long-distance transport of iP-type CKs. Biochemical characterization of AtABCG14 revealed that it forms homodimers and exhibits transporter properties towards multiple CKs, including iP and tZ types. AtABCG14 expression was induced by iP-type CKs in wild type and cyp735a1/a2 (cypDM) double mutant. The triple mutant atabcg14 cypDM exhibited more severe developmental phenotypes than atabcg14 and cypDM. CK quantification and 2 H 6 -iP isotope tracer experiment showed that the root-to-shoot transport of iP-type CKs was suppressed in atabcg14 cypDM. The reciprocal grafting of atabcg14 cypDM and cypDM revealed that AtABCG14 is responsible for the root xylem-loading and shoot phloem-distribution in the shootward transport of iP-type cytokinoins. Additionally, 2 H 6 -iP tracer experiment showed that the rootward transport of iP-type CKs was dependent on AtABCG14 expression in the roots. Collectively, our results demonstrate the long-distance circular transport of iP-type CKs mediated by AtABCG14 and provide new insights into the transport of CKs and other phytohormones.

59 BASIC BIOLOGICAL SCIENCES↗

Potential defect structure effects in the volatility separation of sub-picogram quantities of fission and activation products from an irradiated UO2 matrix

Here, the use of fluorination as a rapid separation technique for quantification of trace-mass, short-lived isotopes is illustrated. Single crystal 238 UO 2 was exposed to a 14 MeV neutron source to produce mixed fission and activation products. Selective removal of trace volatile fluorides from non-volatile ones produced two results of interest. A decrease in background produced better detection and quantification of select analytes across the gamma spectrum. Second, at the very low burnup condition described, the volatility behaviors of common isotopes were altered relative to their well-established behaviors in higher burnup metal and metal oxide fuels.

Fission and activation product separations↗

Identification and Quantification of Beta-Emitters in Waste Packages by Segmented Gamma-Scanning - 20114

A commonly applied method for the non-destructive characterization of the radioactive inventory of waste packages (e.g. 200-l drums) is segmented gamma-scanning. The gamma-emitting inventory is identified via their characteristic lines in the measured spectra. The corresponding net peak areas allow for quantification applying appropriate models. The identification and quantification of beta-emitters present in the waste package require further evaluation. While some of them emit gamma-rays, too, which can be used for identification and quantification, pure beta-emitters contribute to the gamma-spectra only by their Bremsstrahlung-spectra. {sup 32}P, {sup 90}Sr and {sup 90}Y are typical representatives of these isotopes. A method is developed for identification and quantification of these pure beta-emitters in radioactive waste packages. Origin of the procedure is the evaluation of the measured gamma-spectrum. After the identification of all lines present in the spectrum (characteristic gamma-lines, single- and double-escape-lines, X-ray-lines, annihilation peak etc.) this information is used together with calibration data of the detection system and further a-priori information like matrix composition, cross-section data from databases etc. to simulate the spectra without the Bremsstrahlung-components by an appropriate method. This may be Monte Carlo simulations or, like in our case, a computer code taking into account mathematical descriptions of the physical effects like photo effect, (multiple) Compton scattering, backscattering etc. and the attenuation effects of the waste matrix. In any case, the resulting spectrum must simulate the real spectrum without its Bremsstrahlung-component as good as possible. Subtracting the simulated from the measured spectrum then results in the Bremsstrahlung-components caused by the beta-emitters. Prior to evaluation, a set of Bremsstrahlung-spectra is calculated and stored for different beta-emitters in different matrices using the Bethe-Heitler equation. This data set can be extended for new conditions, if necessary, and is allocated in a data base for future application. Applying a non-linear optimization using the generalized reduced gradient method for comparing the calculated with the derived Bremsstrahlung-spectra results in the identification of the beta-emitter and a factor, which is proportional to its activity. The proportionality is determined by previous calibration measurements. The application of the method is demonstrated by measurements on a 200-l mock-up drum and a real waste package. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Proceedings for the Workshop on Applied Nuclear Data Activities 2024

The Workshop for Applied Nuclear Data Activities (WANDA) is designed to increase communication among nuclear data (ND) users in multidisciplinary federal programs, ND producers, ND funders, and other ND experts. It also presents an opportunity to cross-pollinate ideas as well as introduce ND gaps identified by federal programs to ND experts and ND capabilities to the various federal ND users. WANDA 2024 included five technical sessions, three of which focused on Fusion Energy Sciences (FES)—FES Fusion Neutronics, FES Tritium Production, and FES Material Damage—and two stand-alone sessions—Isotopes and Targetry for Nuclear Data and Uncertainty Quantification. The FES sessions successfully brought new voices to the WANDA discussions, expanding the application space in which nuclear data are critical. FES programs need accurate nuclear data with realistic uncertainty quantification to properly estimate, for example, shielding, activation, tritium production, helium production, structural material integrity, and superconducting magnet operation. This includes a variety of projectile (neutrons, photons, charged particles) and target atoms. One of the action items common to all the FES sessions was a need to perform sensitivity studies to identify the prioritization of nuclear data needs. The Isotopes and Targetry session highlighted the many capabilities available to produce high-quality targets for nuclear data measurements, including 3D printing with spherical powders, combustion synthesis coupled with spin coating & electrospraying, inkjet printing, and isotopic doping. These new methods open doors for more accurate measurement, but it was also stressed that sample characterization following any method of fabrication is of the highest importance to accurately interpret nuclear data measurement results that used that sample. The Uncertainty Quantification (UQ) session was broken into two categories: nuclear data uncertainty quantification and the use of that uncertainty quantification. Thematic to the UQ session was the loss of information when going from nuclear data measurement, to evaluation, to evaluated file, and finally to neutron transport calculations. Current evaluated ND libraries typically only contain covariances, which assume that the probability distributions are Gaussian. Beyond being a simplified assumption for many evaluations, this can lead to negative values on many observables when attempting to sample the covariance. The covariance format, however, is very efficient in that a simple set of linear equations can transform uncertainty from parameters or cross sections to the application of interest. Focused collaboration is needed between nuclear data evaluators and nuclear data users to ensure that needs are being met.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Separation of Lanthanide Isotopes from Mixed Fission Product Samples

The measurement of radioactive fission products from nuclear events has important implications for nuclear data production, environmental monitoring, and nuclear forensics. In a previous paper, the authors reported the optimization of an intra-group lanthanide separation using LN extraction resin from Eichrom Technologies®, Inc. and a nitric acid gradient. In this work, the method was demonstrated for the separation and quantification of multiple short-lived fission product lanthanide isotopes from a fission product sample produced from the thermal irradiation of highly enriched uranium. The separations were performed in parallel in quadruplicate with reproducible results and high decontamination factors for 153 Sm, 156 Eu, and 161 Tb. Based on the results obtained here, the fission yields for 144 Ce, 153 Sm, 156 Eu, and 161 Tb are consistent with published fission yields. This work demonstrates the effectiveness of the separations for the intended application of short-lived lanthanide fission product analysis requiring high decontamination factors.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Detection and quantification of trace technetium in the presence of molybdenum using laser-induced breakdown spectroscopy

Technetium (Tc) is a very important element that is encountered in many aspects, from its presence in radioactive waste and its potential environmental impact to its use as a medical radioisotope. Its detection and quantification in liquid samples is traditionally cumbersome, involving detailed sample preparation and analysis by mass spectrometry or scintillation. This article demonstrates the first comprehensive emission spectral analysis of Tc from a liquid sample by immobilization in a polymer and analysis by laser-induced breakdown spectroscopy (LIBS). A survey of LIBS spectra was completed to identify the strongest analytical lines for quantification of trace Tc in the presence of Mo. The quantification of Tc in a Mo-containing matrix was selected because Tc radioisotopes are the daughter products of Mo isotope decay. The first reported calibration curves by LIBS are provided with limits of detection and quantification down to 0.710 µg mL −1 and 1.39 µg mL −1 , respectively. Ultimately, this study demonstrated the feasibility of trace Tc quantification using LIBS and will serve as a reference for future research related to monitoring this radioactive species.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗