Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isothermal compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Estimation of the Tritium Isotope Effect inthe SAS Compressor Bed 1 Material (LANA10)

A recent report presented a method to estimate the SAS Compressor Bed 1 (SAS CB1) loading level, in Q/M units, based on measured equilibrium pressure and temperature where the material was clearly loaded into the β-phase. This method requires the use of the equilibrium desorption isotherm plateau pressure, but no data exists to specify that value at this time. This report details a previously unreported investigation into tritium isotope effects on plateau pressure of a closely related material, herein called LANA05, conducted in the 1989-to-1993 time frame by then-SRL (Savannah River Laboratory) researchers. Data from that investigation is used to estimate the tritium isotope effect on plateau pressure in the SAS CB1 virgin LANA10 material by constructing a tritium van’t Hoff plot for LANA10 that mimics the isotope behavior in LANA05.

36 MATERIALS SCIENCE↗

Isotherm modeling and techno-economic analysis of a TSA moving bed process using a tetraamine-appended MOF for NGCC applications

Tetraamine-appended metal-organic frameworks (MOF) are a new family of amine-functionalized MOF materials that show potential for CO 2 capture from flue gas conditions relevant to natural gas combined cycle (NGCC) power plants. This work presents isotherm modeling of the tetraamine-appended MOF Mg 2 (dobpdc)(3-4-3)(dobpdc 4- =4,4'-dioxidobiphenyl-3,3'dicarboxylate;3-4-3=N,N'bis(3-aminopropyl)-1,4-diaminobutane), process modeling, scale up, and a techno-economic optimization of a moving bed Temperature Swing Adsorption (TSA) process for carbon capture using this sorbent. This MOF exhibits a unique two-step CO 2 adsorption profile in three different pressure ranges. Thus, arctangent-based logistic functions and, quadratic and Langmuir models were employed to represent such isotherm behavior. The results of the isotherm model show good fitting vs the experimental data with an RMSE of 0.41. Here, to model the carbon capture process, the isotherm model was embedded into a moving bed contactor model, and this was used to simulate a TSA CO 2 capture cycle and evaluate cost-optimal designs considering flue gas from a -650 MWe NGCC power plant. The capital cost model consists of CAPEX correlations for reactors, compressors, ducting, etc., while the operating costs include steam, water, chemicals, and electricity (following NETL's quality guidelines for energy systems studies). A techno-economic optimization of the capture system was performed by using NETL's Framework for the Optimization and Quantification of Uncertainty and Surrogates tool (FOQUS). Results suggest that a moving bed carbon capture system with tetraamine-appended MOF can be competitive compared to conventional MEA solvent-based capture processes for NGCC plants, when a heat recovery efficiency of at least 40% is achieved, and MOF materials can be produced at a cost below -$9/kg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗