Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isopropanol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

32 records · Page 2

Integrated optics ring-resonator chemical sensor with polymer transduction layer

An integrated optics chemical sensor based on a ring resonator with an ethyl cellulose polymer coating has been demonstrated. The measured sensitivity to isopropanol in air is 50 ppm-the level immediately useful for health-related air quality monitoring. The resonator was fabricated using SiO2 and SixNy materials. The signal readout is based on tracking the wavelength of a resonance peak. The resonator layout optimisation for sensing applications is discussed.

chemical sensors.↗

Remote Raman Sensor System for Testing of Rocks and Minerals

Recent and future explorations of Mars and lunar surfaces through rovers and landers have spawned great interest in developing an instrument that can perform in-situ analysis of minerals on planetary surfaces. Several research groups have anticipated that for such analysis, Raman spectroscopy is the best suited technique because it can unambiguously provide the composition and structure of a material. A remote pulsed Raman spectroscopy system for analyzing minerals was demonstrated at NASA Langley Research Center in collaboration with the University of Hawaii. This system utilizes a 532 nm pulsed laser as an excitation wavelength, and a telescope with a 4-inch aperture for collecting backscattered radiation. A spectrograph equipped with a super notch filter for attenuating Rayleigh scattering is used to analyze the scattered signal. To form the Raman spectrum, the spectrograph utilizes a holographic transmission grating that simultaneously disperses two spectral tracks on the detector for increased spectral range. The spectrum is recorded on an intensified charge-coupled device (ICCD) camera system, which provides high gain to allow detection of inherently weak Stokes lines. To evaluate the performance of the system, Raman standards such as calcite and naphthalene are analyzed. Several sets of rock and gemstone samples obtained from Ward s Natural Science are tested using the Raman spectroscopy system. In addition, Raman spectra of combustible substances such acetone and isopropanol are also obtained. Results obtained from those samples and combustible substances are presented.

Garcia, Christopher S.↗

Micro- and Nanostructured Metal Oxide Chemical Sensors for Volatile Organic Compounds

Aeronautic and space applications warrant the development of chemical sensors which operate in a variety of environments. This technical memorandum incorporates various kinds of chemical sensors and ways to improve their performance. The results of exploratory investigation of the binary composite polycrystalline thick-films such as SnO2-WO3, SnO2-In2O3, SnO2-ZnO for the detection of volatile organic compound (isopropanol) are reported. A short review of the present status of the new types of nanostructured sensors such as nanobelts, nanorods, nanotube, etc. based on metal oxides is presented.

Alim, M. A.↗

Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents

A multi-analyte sensor was developed that enables simultaneous detection of rocket engine combustion-product molecules in a launch-vehicle ground test stand. The sensor was developed using a pin-printing method by incorporating multiple sensor elements on a single chip. It demonstrated accurate and sensitive detection of analytes such as carbon dioxide, carbon monoxide, kerosene, isopropanol, and ethylene from a single measurement. The use of pin-printing technology enables high-volume fabrication of the sensor chip, which will ultimately eliminate the need for individual sensor calibration since many identical sensors are made in one batch. Tests were performed using a single-sensor chip attached to a fiber-optic bundle. The use of a fiber bundle allows placement of the opto-electronic readout device at a place remote from the test stand. The sensors are rugged for operation in harsh environments.

Goswami, Kisholoy↗

Higher Magnification Imaging of the Polished Aluminum Collector Returned from the Genesis Mission

The polished aluminum collector (previously referred to as the polished aluminum kidney) was intended for noble gas analysis for the Gene-sis mission. The aluminum collector, fabricated from alloy 6061T, was polished for flight with alumina, then diamond paste. Final cleaning was performed by soak-ing and rinsing with hexane, then isopropanol, and last-ly megasonically energized ultrapure water prior to installation. It was mounted inside the collector canister on the thermal shield at JSC in 2000. The polished aluminum collector was not surveyed microscopically prior to flight.

Rodriquez, Melissa C.↗

Synthesizing Diamond from Liquid Feedstock

A relatively economical method of chemical vapor deposition (CVD) has been developed for synthesizing diamond crystals and films. Unlike prior CVD methods for synthesizing diamond, this method does not require precisely proportioned flows of compressed gas feedstocks or the use of electrical discharges to decompose the feedstocks to obtain free radicals needed for deposition chemical reactions. Instead, the feedstocks used in this method are mixtures of common organic liquids that can be prepared in advance, and decomposition of feedstock vapors is effected simply by heating. The feedstock used in this method is a solution comprising between 90 and 99 weight percent of methanol and the balance of one or more other oxyhydrocarbons that could include ethanol, isopropanol, and/or acetone. This mixture of compounds is chosen so that dissociation of molecules results in the desired proportions of carbon-containing radicals (principally, CH3) and of OH, H, and O radicals. Undesirably, the CVD temperature and pressure conditions thermodynamically favor the growth of graphite over the growth of diamond. The H radicals are desirable because they help to stabilize the growing surface of diamond by shifting the thermodynamic balance toward favoring the growth of diamond. The OH and O radicals are desirable because they preferentially etch graphite and other non-diamond carbon, thereby helping to ensure the net deposition of pure diamond. The non-methanol compounds are included in the solution because (1) methanol contains equal numbers of C and O atoms; (2) an excess of C over O is needed to obtain net deposition of diamond; and (3) the non-methanol molecules contain multiple carbon atoms for each oxygen atom and thus supply the needed excess carbon A typical apparatus used in this method includes a reservoir containing the feedstock liquid and a partially evacuated stainless-steel reaction chamber. The reservoir is connected to the chamber via tubing and a needle valve or other suitable flow controller. When the liquid enters the low-pressure environment inside the chamber, it evaporates to form a vapor mixture of the same chemical composition. In addition to the inlet for the feedstock liquid, the chamber is fitted with an outlet connected to a vacuum pump (not shown) through a throttle valve (also not shown) that is automatically controlled to keep the pressure at or near the required value throughout the deposition process. Inside the chamber, a spiral filament made of tungsten, tantalum, graphite, or other high-melting-temperature material is electrically heated to a temperature >2,000 C high enough to cause dissociation of vapor molecules into the aforementioned radicals. A deposition substrate typically, a diamond-polished silicon wafer about 2.5 cm square is positioned about 2 cm away from the filament. The exact location of the substrate is chosen so that the substrate becomes heated by the filament to a deposition temperature in the approximate range of 800 to 1,000 C.

Tzeng, Yonhua↗

Whole Module Offgas Test Report: Space-X Dragon Module

Between 7 April and 11 April 2012 a chemist from the JSC Toxicology Group acquired samples of air in 500 ml evacuated canisters from the sealed Dragon Module at the Space-X facility at KSC. Three samples were taken of facility air (two before the test and one after the test), and a total of 9 samples were taken from the sealed module in triplicate at the following times: 0 hours, 48 hours, and 96 hours. The module contained 470 kg, which was 100% of the mass to be launched. Analytical data contained in the Toxicology Group Report (attached) show that the ambient facility air was clean except for almost 9 milligrams per cubic meter of isopropanol (IPA) in the sample taken at the end of the test. Space-X must ensure that IPA is not introduced into the module before it is sealed for launch. Other minor contaminants in the ambient air included the following: perfluoro(2-methyl)pentane and hexamethylcyclotrisiloxane. The first-acquired samples of each triplicate from the module were not analyzed. Analyses of pairs of samples that were taken during the test show excellent agreement between the pairs and a linear increase in the T-values during the 4 days of the test (figure below). The rate of increase averaged 0.124 T units per day. If the time from last purge of the module on the ground to crew first entry on orbit is 10 days, then the T value at first entry should be less than 1.2 units, which is well below the criterion of 3.0 for consideration of additional protection of the crew from offgas products. The primary contributors were as follows: trimethylsilanol (0.057), fluorotrimethylsilane (0.047), acetaldehyde (0.004), hexamethylcyclopentasiloxane (0.003), and toluene (0.002).

James, John T.↗

Techniques for Solution- Assisted Optical Contacting

A document discusses a solution-assisted contacting technique for optical contacting. An optic of surface flatness Lambda/20 was successfully contacted with one of moderate surface quality, or Lambda/4. Optics used were both ultra-low expansion (ULE) glass (Lambda/4 and Lambda/20) and fused silica (Lambda/20). A stainless steel template of the intended interferometer layout was designed and constructed with three contact points per optic. The contact points were all on a common side of the template. The entire contacting jig was tilted at about 30 . Thus, when the isopropanol was applied, each optic slid due to gravity, resting on the contact points. All of the contacting was performed in a relatively dusty laboratory. A number of successful contacts were achieved where up to two or three visible pieces of dust could be seen. These were clearly visible due to refraction patterns between the optic and bench. On a number of optics, the final step of dropping isopropyl between the surfaces was repeated until a successful contact was achieved. The new procedures realized in this work represent a simplification for optical contacting in the laboratory. They will both save time and money spent during the contacting process, and research and development phases. The techniques outlined are suitable for laboratory experiments, research, and initial development stages.

DeVine, Glenn↗

Alternative, Green Processes for the Precision Cleaning of Aerospace Hardware

Precision cleaning is necessary to ensure the proper functioning of aerospace hardware, particularly those systems that come in contact with liquid oxygen or hypergolic fuels. Components that have not been cleaned to the appropriate levels may experience problems ranging from impaired performance to catastrophic failure. Traditionally, this has been achieved using various halogenated solvents. However, as information on the toxicological and/or environmental impacts of each came to light, they were subsequently regulated out of use. The solvent currently used in Kennedy Space Center (KSC) precision cleaning operations is Vertrel MCA. Environmental sampling at KSC indicates that continued use of this or similar solvents may lead to high remediation costs that must be borne by the Program for years to come. In response to this problem, the Green Solvents Project seeks to develop state-of-the-art, green technologies designed to meet KSCs precision cleaning needs.Initially, 23 solvents were identified as potential replacements for the current Vertrel MCA-based process. Highly halogenated solvents were deliberately omitted since historical precedents indicate that as the long-term consequences of these solvents become known, they will eventually be regulated out of practical use, often with significant financial burdens for the user. Three solvent-less cleaning processes (plasma, supercritical carbon dioxide, and carbon dioxide snow) were also chosen since they produce essentially no waste stream. Next, experimental and analytical procedures were developed to compare the relative effectiveness of these solvents and technologies to the current KSC standard of Vertrel MCA. Individually numbered Swagelok fittings were used to represent the hardware in the cleaning process. First, the fittings were cleaned using Vertrel MCA in order to determine their true cleaned mass. Next, the fittings were dipped into stock solutions of five commonly encountered contaminants and were weighed again showing typical contaminant deposition levels of approximately 0.00300g per part. They were then cleaned by the solvent or process being tested and then weighed a third time which allowed for the calculation of the cleaning efficiency of the test solvent or process.Based on preliminary experiments, five solvents (ethanol, isopropanol, acetone, ethyl acetate, and tert-butyl acetate) were down selected for further testing. When coupled with ultrasonic agitation, these solvents removed hydrocarbon contaminants as well as Vertrel MCA and showed improved removal of perfluorinated greases. Supercritical carbon dioxide did an excellent job dissolving each of the five contaminants but did a poor job of removing Teflon particles found in the perfluorinated greases. Plasma cleaning efficiency was found to be dependent on which supply gas was used, exposure time, and gas pressure. Under optimized conditions it was found that breathing air, energized to the plasma phase, was able to remove nearly 100% of the contamination.These findings indicate that alternative cleaning methods are indeed able to achieve precision levels of cleanliness. Currently, our team is working with a commercial cleaning company to get independent verification of our results. We are also evaluating the technical and financial aspects of scaling these processes to a size capable of supporting the future cleaning needs of KSC.

Vertrel MCA↗

Effects of Ambient Alcohol Levels on the Real-time Monitoring of the Atmosphere of the International Space Station

Monitoring of the spacecraft environment is required to ensure the health of the crew and the vehicle systems. For the ISS atmosphere, routine volatile organic compound (VOC) monitoring has been performed for almost a decade by Air Quality Monitors (AQMs). The target compounds measured by the AQMs include three types of chemicals: 1) those compounds that would be harmful to crew, 2) those compounds that have been detected regularly in archival samples, and 3) compounds that, while not necessarily harmful to crew health, could present problems for Environmental Control and Life Support Systems (ECLSS). Following the docking of SpaceX-Demo1 (SpX-DM1), the AQMs began to report high levels of isopropanol (IPA). While elevated IPA is routinely observed with visiting vehicles, the level measured by the AQM, and its continued presence following multiple days of scrubbing, caused concerns regarding the U.S. Water Recovery System. Following the departure of SpX-DM1, the IPA levels decreased to nominal levels, allowing the team to investigate the cause of the elevated measurements. Based on the changes in the shape of the gas chromatograph (GC) traces in the IPA region during docked operations, it appeared that an unknown coeluting species was causing problems with quantification. However, with the docking of Northrup-Grumman-11 (NG-11), the elevated IPA returned, as well as the changes in GC traces. In contrast to the SpX-DM1 results, the AQM IPA results did not return to nominal levels following the departure of NG-11, suggesting that the changes could not be tied directly to the visiting vehicle. In this paper, we will discuss a number of potential causes for both the genuine (measured in archival samples) increases in IPA as well as the much higher levels measured by the AQM. Additionally, we will discuss methods being explored to decrease the potential for a reoccurrence in the future.

William T. Wallace↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

W T Wallace↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

William T. Wallace↗