Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isobar separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Separating the Impact of Nuclear Skin and Nuclear Deformation in High-Energy Isobar Collisions

Bulk nuclear structure properties, such as radii and deformations, leave distinct signatures in the final state of relativistic heavy-ion collisions. Isobaric collisions offer an easy route to establish explicit connections between the colliding nuclei's structure and the observable outcomes. Here, we investigate the effects of nuclear skin thickness and nuclear deformations on the elliptic flow (v 2 ) and its fluctuations in high-energy 96 Ru + 96 Ru and 96 Zr + 96 Zr collisions. Furthermore, our findings reveal that the difference in skin thickness between these isobars only influences the inherent ellipticity of the collision systems, $v_2^{rp}$. In contrast, differences in nuclear deformations solely impact the fluctuations of v 2 around $v_2^{rp}$. Hence, we have identified a data-driven method to disentangle the effects of nuclear skin and nuclear deformations, marking a significant step toward assessing the consistency of nuclear phenomena across energy scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct evaluation of the phase diagrams of dense multicomponent plasmas by integration of the Clapeyron equations

Accurate phase diagrams of multicomponent plasmas are required for the modeling of dense stellar plasmas, such as those found in the cores of white dwarf stars and the crusts of neutron stars. Those phase diagrams have been computed using a variety of standard techniques, which suffer from physical and computational limitations. Here we present an efficient and accurate method that overcomes the drawbacks of previously used approaches. In particular, finite-size effects are avoided as each phase is calculated separately; the plasma electrons and volume changes are explicitly taken into account; and arbitrary analytic fits to simulation data as well as particle insertions are avoided. Furthermore, no simulations at “uninteresting” state conditions, i.e., away from the phase coexistence curves, are required, which improves the efficiency of the technique. The method consists of an adaptation of the so-called Gibbs-Duhem integration approach to electron-ion plasmas, where the coexistence curve is determined by direct numerical integration of its underlying Clapeyron equation. The thermodynamics properties of the coexisting phases are evaluated separately using Monte Carlo simulations in the isobaric semigrand canonical ensemble (NPT Δ μ ). We describe this Monte Carlo-based Clapeyron integration method, including its basic physical and numerical principles, our extension to electron-ion plasmas, and our numerical implementation. We illustrate its applicability and benefits with the calculation of the melting curve of dense carbon-oxygen plasmas under conditions relevant for the cores of white dwarf stars and provide analytic fits to implement this new melting curve in white dwarf models. While this work focuses on the liquid-solid phase boundary of dense two-component plasmas, a wider range of physical systems and phase boundaries are within the scope of the Clapeyron integration method, which had until now only been applied to simple model systems of neutral particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Simulations Probing the Adsorption and Diffusion of Ammonia, Nitrogen, Hydrogen, and Their Mixtures in Bulk MFI Zeolite and MFI Nanosheets at High Temperature and Pressure

Recent advances in the synthesis of MFI zeolite nanosheets have led to highly selective membranes that are promising candidates for small-scale ammonia separation from ammonia/nitrogen/hydrogen mixtures in distributed green ammonia production plants. Using force-field-based molecular simulations, we evaluate the performance of bulk all-silica MFI zeolite and a 3 nm thick all-silica MFI nanosheet for ammonia/nitrogen/hydrogen separations at moderate temperature and pressure conditions (T = 373 K, p = 5 bar) as well as conditions relevant for a membrane-based reactor–separator process (T = 523 or 623 K, p = 80 bar). Isobaric–isothermal Gibbs ensemble Monte Carlo (GEMC) simulations were carried out to understand the selective adsorption behavior for these mixtures. Molecular dynamics simulations in the canonical ensemble were performed to examine the transport behavior of ammonia in a mixture with nitrogen or hydrogen at loadings obtained from the GEMC simulations. Our results show that both bulk MFI and the nanosheet with explicit surface silanols are highly selective toward ammonia adsorption, but the adsorption selectivity decreases by factors of 4 and 10 for ammonia/nitrogen and ammonia/hydrogen mixtures as the temperature is increased from 373 to 623 K. Conversely, the diffusion selectivities toward ammonia are more favorable at process-relevant temperatures and for the MFI nanosheet. Here, at T = 523 K and p = 80 bar, our simulations predict overall separation factors of 3.8 ± 0.2 and 4.5 ± 0.3 for ammonia/nitrogen and ammonia/hydrogen mixtures, respectively, in the bulk MFI zeolite, and separation factors of 8.6 ± 0.4 and 12.5 ± 0.8, respectively, for the MFI nanosheet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system

The determination of actinide (e.g., U and Pu) content and isotopics is of importance to the nuclear forensics and safeguards communities. However, in the analysis of environmental samples, such as those collected by the International Atomic Energy Agency, uranium measurements can be complicated by isobaric interferences from polyatomic variants of heavy elements (e.g., Pb). This leads to complex, time-consuming sample manipulations (i.e., separations) before determining isotope ratios. An alternative strategy to sample pretreatment is to use high-resolution mass spectrometric platforms during the analysis to fully resolve the uranium isotopes from potential polyatomic interferences, negating the need for prior chemical separation. The liquid sampling - atmospheric pressure glow discharge (LS-APGD) coupled with an Orbitrap mass spectrometer provides a high-resolution (>70,000 m/Δm at m/z 200) inorganic mass spectrometry platform. Further, as a demonstration of the power of this instrumental platform, and indeed, the high-resolution approach in general, uranium isotope ratios were determined in the presence of elemental impurities (e.g., Pb, Pt, Ta, W) commonly encountered with environmental sample swipe analysis, without any prior treatment. Even at elemental impurity concentrations of 1000–5000× relative to uranium, no interference was observed with the 235 U or 238 U signal. In addition, the 235 U/ 238 U isotope ratio for the samples with the concomitants present are within 2 standard deviations of the values obtained without their addition, indicating that these impurities do not impact the determined uranium isotope ratio. These findings represent a significant first step in leveraging the high resolution of the LS-APGD-Orbitrap-MS to overcome isobaric and molecular interferences instead of relying on chemical separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Implications of the isobar-run results for the chiral magnetic effect in heavy-ion collisions

The chiral magnetic effect (CME) is a macroscopic transport phenomenon induced by a quantum anomaly in the presence of chiral imbalance and an external magnetic field. Relativistic heavy ion collisions provide the unique opportunity to look for CME in a non-Abelian plasma, where the chiral imbalance is created by topological transitions similar to those occurring in the early universe. The isobar run at Relativistic Heavy Ion Collider was proposed as a way to separate the possible CME signal driven by magnetic field from the background. The first blind analysis results from this important experiment were recently released by the STAR Collaboration. Notably, under the pre-defined assumption of identical background in RuRu and ZrZr, the results are inconsistent with the presence of CME, as well as with all existing theoretical models (whether including CME or not). However the observed difference of backgrounds must be taken into account before any physical conclusion is drawn. In this paper, we show that once the observed difference in hadron multiplicity and collective flow are quantitatively taken into account, the STAR results could be consistent with a finite CME signal contribution of about (6.8 ± 2.6)%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evolution of radiative thermal instability in a confined medium

Thermally bistable fluid tends to self-organize into clouds of hot and cold material, which are internally uniform and separated by thin conduction fronts. The evolution of these clouds has been studied for isobaric systems, but when pressure is instead treated as a dynamical quantity and allowed to evolve self-consistently, fundamentally different dynamics appear. Such a treatment is necessary in some laboratory plasmas, whose volume is constrained but whose pressure can vary. Here, solutions are derived for the evolution of clouds, accounting for pressure variation and interactions between conduction fronts. Additional stable configurations and secondary instabilities are derived, which may be relevant to fusion plasmas and to the study of photoionized plasma in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high-voltage MR-ToF mass spectrometer and separator for the study of exotic isotopes at FRIB

The Facility for Rare Isotope Beams (FRIB) delivers a wide variety of rare isotopes as fast, stopped, or reaccelerated beams to enable forefront research in nuclear structure, astrophysics, and fundamental interactions. To expand the scientific potential of FRIB’s stopped and reaccelerated beam programs, we are designing a Multi-Reflection Time-of-Flight mass spectrometer and separator (MR-ToF MS). It will enable high-precision mass measurements of short-lived isotopes, improve beam diagnostics, and deliver isobarically and isomerically purified beams to downstream experimental stations. It is designed to store ions at a kinetic energy of 30 keV, significantly enhancing ion throughput while maintaining high mass resolving power. In conclusion, we present the scientific motivation, technical design, and simulations demonstrating the expected performance of the system, which has the potential to significantly enhance FRIB’s mass measurement, diagnostic, and mass separation capabilities.

Electrostatic ion beam trap↗

A single column separation method for barium isotope analysis of geologic and hydrologic materials with complex matrices

Abstract The increasing significance of barium (Ba) in environmental and geologic research in recent years has led to interest in the application of the Ba isotopic composition as a tracer for natural materials with complex matrices. Most Ba isotope measurement techniques require separation of Ba from the rest of sample prior to analysis. This paper presents a method using readily available materials and disposable columns that effectively separates Ba from a range of geologic and hydrologic materials, including carbonate minerals, silicate rocks, barite, river water, and fluids with high total dissolved solids and organic content such as oil and gas brines, rapidly and without need for an additional cleanup column. The technique involves off-the-shelf columns and cation exchange resin and a two-reagent elution that uses 2.5 N HCl followed by addition of 2.0 N HNO 3 . We present data to show that major matrix elements from almost any natural material are separated from Ba in a single column pass, and that the method also effectively reduces or eliminates isobaric interferences from lanthanum and cerium.

Matecha, R. M.↗

Influence of 73 Rb on the ashes of accreting neutron stars

We find that the proton separation energy, S(p), of 73 Rb is –640(40) keV, deduced from the observation of β-delayed ground-state protons following the decay of 73 Sr. This lower-limit determination of the proton separation energy of 73 Rb coupled with previous upper limits from nonobservation, provides a full constraint on the mass excess with ΔM ( 73 Rb) = –46.01 ± 0.04 MeV. With this new mass excess and the excitation energy of the J π = 5/2 – isobaric-analog state (T = 3/2) in 73 Rb, an improved constraint can be put on the mass excess of 73Sr using the isobaric-multiplet mass equation (IMME), and we find ΔM( 73 Sr) = –31.98 ± 0.37 MeV. Furthermore, these new data were then used to study the composition of ashes on accreting neutron stars following Type I x-ray bursts. Counterintuitively, we find that there should be an enhanced fraction of A > 102 nuclei with more negative proton separation energies at the 72 Kr rp-process waiting point. Larger impurities of heavier nuclei in the ashes of accreting neutron stars will impact the cooling models for such astrophysical scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for the chiral magnetic effect with isobar collisions at $\sqrt{s_{NN}}$ = 200 GeV by the STAR Collaboration at the BNL Relativistic Heavy Ion Collider

The chiral magnetic effect (CME) is predicted to occur as a consequence of a local violation of P and CP symmetries of the strong interaction amidst a strong electro-magnetic field generated in relativistic heavy-ion collisions. Experimental manifestation of the CME involves a separation of positively and negatively charged hadrons along the direction of the magnetic field. Previous measurements of the CME-sensitive charge-separation observables remain inconclusive because of large background contributions. In order to better control the influence of signal and backgrounds, the STAR Collaboration performed a blind analysis of a large data sample of approximately 3.8 billion isobar collisions of $^{96}_{44}$Ru + $^{96}_{44}$Ru and $^{96}_{40}$Zr + $^{96}_{40}$Zr at $\sqrt{s_{NN}}$ = 200 GeV. Prior to the blind analysis, the CME signatures are predefined as a significant excess of the CME-sensitive observables in Ru + Ru collisions over those in Zr + Zr collisions, owing to a larger magnetic field in the former. Here, a precision down to 0.4% is achieved, as anticipated, in the relative magnitudes of the pertinent observables between the two isobar systems. Observed differences in the multiplicity and flow harmonics at the matching centrality indicate that the magnitude of the CME background is different between the two species. No CME signature that satisfies the predefined criteria has been observed in isobar collisions in this blind analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Complete β-decay patterns of 142 Cs, 142 Ba, and 142 La determined using total absorption spectroscopy

Background: The β decays of fission products produced in nuclear fuel are important for nuclear energy applications and fundamental science of reactor antineutrinos. In particular, nuclear reactor safety is related to the decay modes of radioactive neutron-rich nuclei, primarily via the emission of γ rays, neutrons, and electrons. Additionally nuclear reactors are the most powerful man-made source of antineutrinos emitted during the β decay of fission products. These antineutrinos are used to inspect fundamental properties of leptons as well as informing reactor operation. However, the majority of data on complex decays of fission products collected in the evaluated nuclear data repositories like Evaluated Nuclear Structure Data File (ENSDF) and Evaluated Nuclear Data Files (ENDF) are based on low-efficiency and often incomplete measurements resulting in questionable reference reactor antineutrino flux predictions, see the analysis by [Nichols, J. Nucl. Sci. Technol. 52, 17 (2015)]. Various assessments like the one done under the auspices of the [Yoshida et al., Assessment of Fission Product Decay Data for Decay Heat Calculations: A report by the Working Party on International Evaluation Co-operation of the Nuclear Energy Agency Nuclear Science Committee (Nuclear Energy Agency, Organization for Economic Co-operation and Development, Paris, France, 2007), Vol. 25], as well as by [Sonzogni, Johnson, and McCutchan, Phys. Rev. C 91, 011301(R) (2015)] and [Dwyer and Langford, Phys. Rev. Lett. 114, 012502 (2015)], list the A = 142 isobars with high cumulative fission yield among the important nuclei where data for reactor decay heat and/or antineutrino production should be verified and/or improved. Purpose: Here, our goal is to improve the quality of β -decay measurements and evaluate the impact of modified decay schemes on reactor decay heat and antineutrino energy spectra, for fission products along the A = 142 isobaric chain. This work is an in depth follow-up on [Rasco et al., Phys. Rev. Lett. 117, 092501 (2016)]. which presented briefly the impact of the corrected decay scheme of 142 Cs . Here, we extend the data to full isobaric decay chain including the daughter nuclei, 142 Ba and 142 La, and present more details on the 142 Cs results. Method: The decays of neutron-rich isobars of mass A = 142 produced by means of proton-induced fission of 238 U were measured using the Modular Total Absorption Spectrometer (MTAS) array on-line at the mass separator and Tandem accelerator at Oak Ridge National Laboratory. Results: The β -decay schemes for 142 Cs and 142 La were modified with respect to the nuclear data repositories. A small β-delayed neutron branching ratio for 142 Cs emitter was remeasured as $0.10^{+5}_{–3}% %. Improved precision on the measured half-lives is reported. Small corrections to the low-energy decay of 142 Ba are made. The β-decay patterns for 142 La and 142 Cs are presented. The decay heat release and cross section for the detection of reactor antineutrinos are deduced and compared to earlier results. Conclusions: The β-feeding pattern for 142 Cs having decay energy value $Q_β$ of over 7 MeV was substantially modified with respect to the current ENSDF entry. Smaller changes were encountered for 142 La, but since this A = 142 isobar also has a large cumulative yield in fission, the changes influence both decay heat and the antineutrino spectra. The previously known β intensities for 142 Ba decay ($Q_β$ value of 2.2 MeV) were verified and slightly modified. Overall, increased decay heat values and lower flux of antineutrinos interacting with matter are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Myalgic encephalomyelitis/chronic fatigue syndrome and fibromyalgia are indistinguishable by their cerebrospinal fluid proteomes

Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) and fibromyalgia have overlapping neurologic symptoms particularly disabling fatigue. This has given rise to the question whether they are distinct central nervous system (CNS) entities or is one an extension of the other. To investigate this, we used unbiased quantitative mass spectrometry-based proteomics to examine the most proximal fluid to the brain, cerebrospinal fluid (CSF). This was to ascertain if the proteome profile of one was the same or different from the other. We examined two separate groups of ME/CFS, one with (n = 15) and one without (n = 15) fibromyalgia. We quantified a total of 2083 proteins using immunoaffinity depletion, tandem mass tag isobaric labelling and offline two-dimensional liquid chromatography coupled to tandem mass spectrometry, including 1789 that were quantified in all the CSF samples. ANOVA analysis did not yield any proteins with an adjusted p value <.05. This supports the notion that ME/CFS and fibromyalgia as currently defined are not distinct entities.

60 APPLIED LIFE SCIENCES↗

Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

Radio-chronometric studies on plutonium (Pu) materials require independent measurement of the Pu (parent) content and isotopic distribution as well as concentration and isotopic distribution of the plutonium isotopic decay products. We performed a series of experiments to demonstrate the consistency of separations using the Lewatit MP 800 macroporous anion exchange resin and the AG MP-1M resin with traceable Pu isotopic certified reference material (CRM) standards 136, 137, 138, and 126-A. Two different mesh-sizes of the AG MP-1M resin were tested and the 50–100 mesh size resin was found to work more efficiently for the separation task. Both Lewatit and AG MP-1M resins were found to perform satisfactorily for quantitatively extracting the americium (Am) and uranium (U) progeny as well as gallium (Ga) present as a tracer in the Pu material. Both resins were effective in removing isobaric interferences from the Pu fraction used in isotopic measurements by thermal ionization mass spectrometry (TIMS). To address the co-elution of uranium and gallium, Alizarin red S (ARS) was used as a colorimetric dye to determine the behavior of UO 2 2+ and Ga 3+ on AG MP-1M resin with various acidic solutions as eluents using UV–vis spectra. Poor resolution of these peaks complicated quantitative analysis by UV–vis spectroscopy, but these results were informative in planning automated separation experiments by HPLC. LA-UR-24-28919.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Collective Summary of sCO2 Materials Development (Supercritical Transformational Electric Power Generation (STEP) Level 2 Milestone Report) (Parts I - II)

Polymers such as PTFE (polytetrafluorethylene or Teflon), EPDM (ethylene propylene diene monomer) rubber, FKM fluoroelastomer (Viton), Nylon 11, Nitrile butadiene (NBR) rubber, hydrogenated nitrile rubber (HNBR) and perfluoroelastomers (FF_202) are commonly employed in super critical CO 2 (sCO2) energy conversion systems. O-rings and gaskets made from these polymers face stringent performance conditions such as elevated temperatures, high pressures, pollutants, and corrosive humid environments. In FY 2019, we conducted experiments at high temperatures (100°C and 120°C) under isobaric conditions (20 MPa). Findings showed that elevated temperatures accelerated degradation of polymers in sCO2, and that certain polymer microstructures are more susceptible to degradation over others. In FY 2020, the focus was to understand the effect of sCO2 on polymers at low (10 MPa) and high pressures (40 MPa) under isothermal conditions (100°C). It was clear that the same selectivity was observed in these experiments wherein certain polymeric functionalities showed more propensity to failure over others. Fast diffusion, supported by higher pressures and long exposure times (1000 hours) at the test temperature, caused increased damage in sCO2 environments to even the most robust polymers. We also looked at polymers under compression in sCO2 at 100°C and 20 MPa pressure to imitate actual sealing performance required of these materials in sCO2 systems. Compression worsened the physical damage that resulted from chemical attack of the polymers under these test conditions. In FY 2021, the effect of cycling temperature (from 50°C to 150°C to 50°C) for polymers under a steady sCO2 pressure of 20 MPa was studied. The aim was to understand the influence of cycling temperatures of sCO2 for typical polymers under isobaric (20 MPa) conditions. Thermoplastic polymers (Nylon, and PTFE) and elastomers (EPDM, Viton, Buna N, Neoprene, FF202, and HNBR) were subjected to 20 MPa sCO2 pressure for 50 cycles and 100 cycles in separate experiments. Samples were extracted for ex-situ characterization at 50 cycles and upon the completion of 100 cycles. Each cycle constituted of 175 minutes of cycling from 50°C to 150°C. The polymer samples were examined for physical and chemical changes by Dynamic Mechanical and Thermal Analysis (DMTA), Fourier Transform Infrared (FTIR) spectroscopy, and compression set. Density and mass changes immediately after removal from test were measured for degree of swell comparisons. Optical microscopy techniques and micro computer tomography (micro CT) images were collected on select specimens. Evaluations conducted showed that exposures to super-critical CO2 environments resulted in combinations of physical and/or chemical changes. For each polymer, the dominance of cycling temperatures under sCO2 pressures, were evaluated. Attempts were made to qualitatively link the permanent sCO2 effects to polymer micro- structure, free volume, backbone substitutions, presence of polar groups, and degree of crystallinity differences. This study has established that soft polymeric materials are conducive to failure in sCO2 through mechanisms of failure that are dependent on polymer microstructure and chemistry. Polar pendant groups, large atom substitutions on the backbone are some of the factors that are influential structural factors.

36 MATERIALS SCIENCE↗

Charge radii of exotic neon and magnesium isotopes

We compute the charge radii and ground-state energies of even-mass neon and magnesium isotopes from neutron number N = 8 to the dripline. Our calculations are based on nucleon-nucleon and three-nucleon potentials from chiral effective field theory that include Δ isobars. These potentials yield an accurate saturation point and symmetry energy of nuclear matter. We use the coupled-cluster method and start from an axially symmetric reference state. Binding energies and two-neutron separation energies largely agree with data, and the dripline in neon is accurate. The computed charge radii are accurate for many isotopes where data exist. Finer details, such as isotope shifts, however, are not accurately reproduced. These chiral potentials indicate a subshell closure at N = 14 for the radii (but not for two-neutron separation energies) and a decrease in charge radii at N = 8 (observed in neon and predicted for magnesium). Furthermore, they yield a continued increase of charge radii as neutrons are added beyond N = 14 yet underestimate the large increase at N = 20 in magnesium.

20 ≤ A ≤ 38↗