Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measuring the Loschmidt Amplitude for Finite-Energy Properties of the Fermi-Hubbard Model on an Ion-Trap Quantum Computer

Calculating the equilibrium properties of condensed-matter systems is one of the promising applications of near-term quantum computing. Recently, hybrid quantum-classical time-series algorithms have been proposed to efficiently extract these properties from a measurement of the Loschmidt amplitude ⟨ ψ | e − i H ^ t | ψ ⟩ from initial states | ψ ⟩ and a time evolution under the Hamiltonian H ^ up to short times t . In this work, we study the operation of this algorithm on a present-day quantum computer. Specifically, we measure the Loschmidt amplitude for the Fermi-Hubbard model on a 16 -site ladder geometry (32 orbitals) on the Quantinuum H2-1 trapped-ion device. We assess the effect of noise on the Loschmidt amplitude and implement algorithm-specific error-mitigation techniques. By using a thus-motivated error model, we numerically analyze the influence of noise on the full operation of the quantum-classical algorithm by measuring expectation values of local observables at finite energies. Finally, we estimate the resources needed for scaling up the algorithm. Published by the American Physical Society 2024

Physics↗

Progress Report for W911NF-23-1-0323: Development of Scalable Three-Dimensional Ion Traps for Quantum Information Processing

Trapped atomic ions are a promising platform for scalable quantum information processing. They lead in many key metrics such as single and two qubit gate fidelities, as well as quantum volume. We recently realized novel 3D ion traps with a high resolution 3D-printing process. The traps combine the scalability potential of surface chip traps with the superior trap performance of macroscopic 3D ion traps. Like photolithography, 3D-printing is a digitally defined process and hence allows for rapid iteration between design and fabrication. In contrast to photolithography, it also allows for fully defined 3D structures and, thus, is an ideal process to develop large, well-defined trap arrays with complex 3D electrode structures. Our current goal is to implement key procedures and perform critical measurements that justify incorporation of 3D-printed traps into large-scale quantum computing efforts. En route, we recently realized trapping in horizontal traps that are operating at cryogenic temperatures.

74 ATOMIC AND MOLECULAR PHYSICS↗

Bilayer Ion Trap Design for 2D Arrays

Junctions are fundamental elements that support qubit locomotion in two-dimensional ion trap arrays and enhance connectivity in emerging trapped-ion quantum computers. In surface ion traps they have typically been implemented by shaping radio frequency (RF) electrodes in a single plane to minimize the disturbance to the pseudopotential. However, this method introduces issues related to RF lead routing that can increase power dissipation and the likelihood of voltage breakdown. Here, we propose and simulate a novel two-layer junction design incorporating two perpendicularly rotoreflected (rotated, then reflected) linear ion traps. The traps are vertically separated, and create a trapping potential between their respective planes. The orthogonal orientation of the RF electrodes of each trap relative to the other provides perpendicular axes of confinement that can be used to realize transport in two dimensions. While this design introduces manufacturing and operating challenges, as now two separate structures have to be precisely positioned relative to each other in the vertical direction and optical access from the top is obscured, it obviates the need to route RF leads below the top surface of the trap and eliminates the pseudopotential bumps that occur in typical junctions. Here in this paper the stability of idealized ion transfer in the new configuration is demonstrated, both by solving the Mathieu equation analytically to identify the stable regions and by numerically modeling ion dynamics. Our novel junction layout has the potential to enhance the flexibility of microfabricated ion trap control to enable large-scale trapped-ion quantum computing.

42 ENGINEERING↗

Two-tone Doppler cooling of radial two-dimensional crystals in a radio-frequency ion trap

We study the Doppler-cooling of radial two-dimensional (2D) Coulomb crystals of trapped barium ions in a radiofrequency trap. Ions in radial 2D crystals experience micromotion of an amplitude that increases linearly with the distance from the trap center, leading to a position-dependent frequency modulation of laser light in each ion's rest frame. We use two tones of Doppler-cooling laser light separated by approximately 100 MHz to efficiently cool distinct regions in the crystals with differing amplitudes of micromotion. This technique allows us to trap and cool more than 50 ions populating 4 shells in a radial two-dimensional crystal, where with a single tone of Doppler cooling light we are limited to 30 ions in 3 shells. Here, we also individually characterize the micromotion of all ions within the crystals, and use this information to locate the center of the trap and to determine the Matthieu parameters q x and q y .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Linear ion trap based atomic frequency standard

In order to develop a trapped ion-based fieldable frequency standard with stability 1 x 10 to the -13th/sq rt tau for averaging times tau greater than 10,000 s, a hybrid RF/DC linear ion trap was developed which permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. The authors have confined Hg-199(+) ions in this trap and have measured very high Q transitions with good SNRs. In preliminary measurements they obtained stabilities of 1.6 x 10 to the -13th/sq rt tau (tau between 50 and 800 s) with a 160-mHz wide atomic resonance linewidth and a signal-to-noise ratio of 40 for each measurement cycle. Atomic resonance lines as narrow as 30 mHz on the 40.5-GHz clock transition have been measured with no appreciable reduction in the ion signal. A stability of 7 x 10 to the -14th/sq rt tau is made possible by the signal-to-noise and line Q of this measured transition. Analysis of fundamental sources of frequency instability indicates that a long-term stability of 2 x 10 to the -16th is feasible for this device with existing technology for tau = 10 to the 6th s or more.

Prestage, John D.↗

Ultra-stable Hg(+) trapped ion frequency standard

A fieldable trapped ion frequency standard based on Hg-199(+) ions confined in a hybrid rf/dc linear ion trap is developed. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the rf confining fields. In preliminary measurements a stability of 2 to 3 x 10(exp -15) was obtained for 10000 second averaging times. These measurements were carried out with a 120 mHz wide atomic resonance line for the 40.5 GHz clock transition with a second order Doppler shift from the rf trapping field of 6 x 10(exp -13).

Prestage, John D.↗

Ion Traps and Packaging for Heterogenous Integration - Chimera

Microfabricated surface ion traps and silicon-based photonics are critical technologies for scaling quantum systems. Current ion trap architectures face scalability and integration challenges due to limitations in optical access, fabrication techniques, and material compatibility. State-of-the-art quantum computers and atomic clocks are investigating monolithic integration, which necessitates custom traps for each ion species and has not overcome the integration hurdles presented by merging these technologies. The Chimera (Ion Traps and Packaging for Heterogeneous Integration) project proposes a novel approach utilizing heterogeneous integration (HI) of ion traps and photonic circuits. This separation of components allows for flexibility in ion trap design and reduces fabrication compromises. The Chimera project specifically designed an ion trap to interface vertically with a separately fabricated waveguide chip and demonstrates the first steps to integrating them at the packaging level. The ion trap features a large area of removed silicon, allowing the photonics chip outputs closer to the ion trap, improving alignment and packaging processes. The alignment must be accurate to < 1 µm to ensure that the light from the waveguide can overlap with the trapping region. This fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. By combining separate chips, we demonstrate a new path for scaling trapped ion technology that is less reliant on monolithic integration. We successfully fabricated a trap with a large area of oxide removed, resulting in a region thinned to about 40 µm, a key milestone toward successful integration.

42 ENGINEERING↗

Entangling-gate error from coherently displaced motional modes of trapped ions

Entangling gates in trapped-ion quantum computers are most often applied to stationary ions with initial motional distributions that are thermal and close to the ground state, while those demonstrations that involve transport generally use sympathetic cooling to reinitialize the motional state prior to applying a gate. Future systems with more ions, however, will face greater nonthermal excitation due to increased amounts of ion transport and exacerbated by longer operational times and variations over the trap array. In addition, pregate sympathetic cooling may be limited due to time costs and laser access constraints. In this paper, we analyze the impact of such coherent motional excitation on entangling-gate error by performing simulations of Mølmer-Sørenson (MS) gates on a pair of trapped-ion qubits with both thermal and coherent excitation present in a shared motional mode at the start of the gate. Here, we quantify how a small amount of coherent displacement erodes gate performance in the presence of experimental noise, and we demonstrate that adjusting the relative phase between the initial coherent displacement and the displacement induced by the gate or using Walsh modulation can suppress this error. We then use experimental data from transported ions to analyze the impact of coherent displacement on MS-gate error under realistic conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microfabricated Devices and Ion Trapping Capabilities

Next generation ion traps will likely need to support tens if not hundreds of ions in order to achieve several logical qubits. As we scale to those sizes, the same problems we face now – rf dissipation, control I/O, and optical access – will only grow and become more complicated. While many of these challenges can potentially be solved with technology integration, independently researching the feasibility of that integration and other solutions may help reduce the time and risk in scaling up to larger traps, by testing on smaller less complex devices. We should also consider other fabrication techniques that may help scale to larger devices, such as: through-substrate-vias (TSVs), different metal coatings, exotic rf routing, on chip laser sources, or even a secondary macroscopic trap to reload ions from. To have these technologies ready for full scale integration when we need them, ion traps with some of these capabilities need to be produced now. Developing the rigorous fabrication methods for producing reliable traps takes time and experimentation. We propose developing larger ion traps and reliable integrated technology in conjunction to make both available faster.

36 MATERIALS SCIENCE↗

Recipe for coating ceramic blades for ion trapping

The first batches of ion traps patterned and coated were processed per the standard 3-step clean, air fire, and metallization processes. The third or fourth lot using this process resulted in poorly adhering metallization. Up until this point, the standard process was used to metallize and pattern ceramic ion traps without fail. At about the 4th batch of parts something changed. After the 5th batch, the ceramic ion traps received generally came with some unknown contamination that does not come off in a standard 3-step clean (Lenium Vapor Degreaser, Acetone, IPA) and air fire (860C for 1 hour) for which this process removes the vast majority of all contamination for most ceramic metallization. This is highly unusual. Using HF + Boiling H 2 O 2 is extreme for cleaning the ceramic ion traps. The contamination was never identified and is stubborn to effectively clean. Standard as-fired ceramic should be very easy to clean as if s fired at temperatures greater than 1400°C and not much in terms of contamination should exist at these temperatures, so there must be an intermediate step/process which is imparting this contamination. It is likely a polishing compound or previous polishing contaminant, but also not easily visually distinguishable until after metallization. The halo marks observed on parts might be fingerprints (less likely) or potential polishing marks (more likely) as metallization typically doesn't cover/hide any damage or contamination, but rather quite clearly the opposite, it accentuates it. Blotchy appearances in the metallization usually indicated an adhesion issue. As a result of the fragility of the parts (yield loss due to handling) and difficulty in identifying the contamination during cleaning, we have taken a conservative approach of HF + H 2 O 2 cleaning for all batches after the contamination and adhesion issues were identified.

36 MATERIALS SCIENCE↗

SIREN: Scaling Ion-Traps by REquiring iNnovative Heterogenous Integration

The SIREN (Scaling Ion Traps by Requiring iNnovative heterogenous integration) project explores the feasibility of heterogeneous integration (HI) as a transformative approach to scaling ion traps, a critical technology for advancing quantum computers and atomic clocks. Traditional ion trap architectures face significant challenges in scalability due to limitations in optical access, fabrication techniques, and material constraints. SIREN addresses these challenges by leveraging HI, which combines different materials and fabrication processes to create more complex and efficient ion trap structures. HI integrated structures can be manufactured without compromising the process to maintain compatibility to ion traps. This project focuses on integrating a separately fabricated waveguide with a fully functional ion trap. The respective alignment between the pieces needs to be accurate to less than 2 µm to ensure that the light from the waveguide can overlap with the trapping region. The fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. The project's outcomes suggest that heterogeneous integration is a promising pathway for overcoming current scalability barriers, paving the way for the next generation of quantum technologies. SIREN's findings contribute significantly to the field, offering a scalable solution that could accelerate the development of practical quantum computers and highly accurate atomic clocks.

42 ENGINEERING↗

Theory of the thermionic current beyond the traditional space charge limit enabled by trapped ions in the virtual cathode

We show that trapped ions in virtual cathode potential wells can raise the transmitted current of emitted electrons into a plasma much closer to the full emission than is predicted by cathode sheath theories without trapped ions. The transmitted current is controlled by the well barrier voltage, which must adjust to balance the creation of low-energy ions within the well, and their loss. Our model considers the case of a plasma-facing cathode where trapped ions are created passively via charge-exchange collisions and lost passively via thermal leakage over the well. We quantify these rates and estimate the current in terms of system parameters for thermionic emission into a plasma with several cathode geometries. A general prediction is that the current as a function of emitted flux does not saturate at the traditional space charge limit (the onset of a well) but can reach far higher values until the trapped ion balance breaks down, causing instability. The maximum stable current depends on parameters but in principle can be arbitrarily high if active techniques are used to manipulate the trapped ion balance. We conclude that major improvements in plasma technologies with hot cathodes might be achieved by optimizing the current enhancement enabled by trapped ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

1 / ω electric-field noise in surface ion traps from correlated adsorbate dynamics

Ion traps are promising architectures for implementing quantum computers, but they suffer from excessive “anomalous” ion motional heating that limit their overall coherence and practicality for scalable quantum computing. The exact microscopic origins of anomalous heating remain an open question, but experiments point to adsorbates on trap electrodes as one likely source. Many different models of anomalous heating have been proposed, but these models have yet to pinpoint the atomistic origin of the experimentally observed 1/ω electric-field noise scaling seen in ion traps at frequencies between 0.1–10 MHz. In this work, we show that a model based on previously proposed surface-induced dipole fluctuations on adsorbates, but which also incorporates interparticle interaction dynamics through molecular dynamics simulations of up to multiple monolayers of adsorbates, gives rise to 1/ω frequency scaling at the MHz frequencies typically employed in ion traps. Overall, these results demonstrate that moderate-to-high densities of adsorbates can give rise to a set of activated motions that produce the 1/ω noise observed in ion traps and that collective adsorbate motions produce the observed noise spectra that a noninteracting model does not capture.

36 MATERIALS SCIENCE↗

Observation of Slow Eigen-Zundel Interconversion in H + (H 2 O) 6 Clusters upon Isomer-Selective Vibrational Excitation and Buffer Gas Cooling in a Cryogenic Ion Trap

The formation of isomers when trapping floppy cluster ions in a temperature-controlled ion trap is a generally observed phenomenon. This involves collisional quenching of the ions initially formed at high temperature by buffer gas cooling until their internal energies fall below the barriers in the potential energy surface that separate them. Here we explore the kinetics at play in the case of the two isomers adopted by the H + (H 2 O) 6 cluster ion that differ in the proton accommodation motif. One of these is most like the Eigen cation with a tricoordinated hydronium motif (denoted E), and the other is most like the Zundel ion with the proton equally shared between two water molecules (denoted Z). After initial cooling to about 20 K in the radiofrequency (Paul) trap, the relative populations of these two spectroscopically distinct isomers are abruptly changed through isomer-selective photoexcitation of bands in the OH stretching region with a pulsed (~6 ns) infrared laser while the ions are in the trap. We then monitor the relaxation of the vibrationally excited clusters and reformation of the two cold isomers by recording infrared photodissociation spectra with a second IR laser as a function of delay time from the initial excitation. The latter spectra are obtained after ejecting the trapped ions into a time-of-flight photofragmentation mass spectrometer, thus enabling long (~0.1 s) delay times. Excitation of the Z isomer is observed to display long-lived vibrationally excited states that are collisionally cooled on a ms time scale, some of which quench into the E isomer. These excited E species then display spontaneous interconversion to the Z form on a ~10 ms time scale. Furthermore, these qualitative observations set the stage for a series of experimental measurements that can provide quantitative benchmarks for theoretical simulations of cluster dynamics and the potential energy surfaces that underlie them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TISCC: A Surface Code Compiler and Resource Estimator for Trapped-Ion Processors

We introduce the Trapped-Ion Surface Code Compiler (TISCC), a software tool that generates circuits for a universal set of surface code patch operations in terms of a native trapped-ion gate set. To accomplish this, TISCC manages an internal representation of a trapped-ion system where a repeating pattern of trapping zones and junctions is arranged in an arbitrarily large rectangular grid. Surface code operations are compiled by instantiating surface code patches on the grid and using methods to generate transversal operations over data qubits, rounds of error correction over stabilizer plaquettes, and/or lattice surgery operations between neighboring patches. Beyond the implementation of a basic surface code instruction set, TISCC contains corner movement functionality and a patch translation that is implemented using ion movement alone. Except in the latter case, all TISCC functionality is extensible to alternative grid-like hardware architectures. TISCC output has been verified using the Oak Ridge Quasi-Clifford Simulator (ORQCS).

LeBlond, Tyler↗

In situ detection of RF breakdown on microfabricated surface ion traps

We report microfabricated surface ion traps are a principal component of many ion-based quantum information science platforms. The operational parameters of these devices are pushed to the edge of their physical capabilities as the experiments strive for increasing performance. When the applied radio-frequency (RF) voltage is increased excessively, the devices can experience damaging electric discharge events known as RF breakdown. We introduce two novel techniques for in situ detection of RF breakdown, which we implemented while characterizing the breakdown threshold of surface ion traps produced at Sandia National Laboratories. In these traps, breakdown did not always occur immediately after increasing the RF voltage, but often minutes or even hours later. This result is surprising in the context of the suggested mechanisms for RF breakdown in vacuum. Additionally, the extent of visible damage caused by breakdown events increased with the applied voltage. To minimize the probability for damage when RF power is first applied to a device, our results strongly suggest that the voltage should be ramped up over the course of several hours and monitored for breakdown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-fidelity trapped-ion qubit operations with scalable photonic modulators

Abstract Experiments with trapped ions and neutral atoms typically employ optical modulators in order to control the phase, frequency, and amplitude of light directed to individual atoms. These elements are expensive, bulky, consume substantial power, and often rely on free-space I/O channels, all of which pose scaling challenges. To support many-ion systems like trapped-ion quantum computers or miniaturized deployable devices like clocks and sensors, these elements must ultimately be microfabricated, ideally monolithically with the trap to avoid losses associated with optical coupling between physically separate components. In this work we design, fabricate, and test an optical modulator capable of monolithic integration with a surface-electrode ion trap. These devices consist of piezo-optomechanical photonic integrated circuits configured as multi-stage Mach-Zehnder modulators that are used to control the intensity of light delivered to a single trapped ion on a separate chip. We use quantum tomography employing hundreds of multi-gate sequences to enhance the sensitivity of the fidelity to the types and magnitudes of gate errors relevant to quantum computing and better characterize the performance of the modulators, ultimately measuring single qubit gate fidelities that exceed 99.7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

It's a Trap! A Review of MOMA and Other Ion Traps in Space or Under Development

Since the Viking Program, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, including (from the inner to outer reaches): Venus (Pioneer); our moon (LADEE); Mars (Viking, Phoenix, and Mars Science Laboratory); and, Saturns largest moon Titan (Cassini-Huygens). More recently, however, ion trap mass spectrometer (ITMS) instruments have found a niche as smaller, versatile alternatives to traditional quadrupole mass analyzers, capable of in situ characterization of planetary environments and the search for organic matter. For example, whereas typical QMS systems are limited to a mass range up to 500 Da and normally require multiple RF frequencies and pressures of less than 10(exp -6) mbar for optimal operation, ITMS instruments commonly reach upwards of 1000 Da or more on a single RF frequency, and function in higher pressure environments up to 10(exp -3) mbar.

ion trap↗