Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion soft landing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Structure and Stability of the Ionic Liquid Clusters [EMIM]n[BF4]n+1- (n = 1 – 9): Implications for Electrochemical Separations

Precise functionalization of electrodes with size-selected ionic liquid (IL) clusters may improve the application of ILs in electrochemical separations. Herein, we report our combined experimental and theoretical investigation of the IL clusters [EMIM]????[BF4]????+1- (n = 1 – 9) and demonstrate their selectivity and efficiency towards targeted adsorption of molecules from solution. The structures and energies of the IL clusters, predicted with global optimization, agree with and help interpret the ion abundances and stabilities measured by high mass resolution electrospray ionization mass spectrometry and collision induced dissociation experiments. The [EMIM][BF4]2- cluster, which was identified as the most stable IL cluster, was selectively soft landed onto a working electrode. Electrochemical impedance spectroscopy revealed a lower charge transfer resistance on the soft-landed electrode containing [EMIM] [BF_4 ]_2^- compared to an electrode prepared by drop casting of IL solution, which contains the full range of IL clusters. Our findings indicate that specific IL clusters may be used to increase the efficiency of electrochemical separations by lowering the overpotentials involved.

Zhang, Jun↗

An Examination of Issues Related to a Europa Subsurface Component for the JIMO Mission

The Galileo Europa data set served to revolutionize our view of Europa. In particular the strong evidence of a large, cold, salty Ocean beneath 5-30 km of ice has profoundly altered the significance of Europa in our thinking, especially of context of habitability in the solar system. While much remains to be learned from spacecraft observations of several sorts, there are significant questions answerable only by in-situ techniques; these relate to the formation of Europa, the nature of its ocean, and the prospects for life in its ocean, sediments, and ice. We feel that wide-ranging discussion of an in-situ subsurface mission to Europa, as part of JIMO, should proceed. The science objective of the mission is to characterize the icy shell of Europa to resolve its provenance, estimate the composition of brine of the Europa ocean, and search for evidence of Earth-like life. Probably anyone would agree that an in-situ mission to Europa would be of great value, but he or she would also immediately take the position that such a mission is utterly impractical. We take the position here of defining the least complex mission that can nonetheless justify its cost and to argue that such a mission is realistic enough that it should be seriously considered. Our mission thinking has been: 1) Soft landing. A soft lander is required on a site sufficiently flat to offer a stable platform; no further site selectivity is required. 2) Subsurface exploration. The Europa subsurface must be examined. Surficial processes on Europa arguably have exposed the upper 200 m of shell to chemical effects from the Jovian radiation belts as well as cometary infall, etc; to examine native ice we must descend below that point to, for discussion, 300 m. At that depth we argue that the ice is characteristic of ice at depth and possibly is effectively sea ice. 3) Science data. A few simple measurements at various depths and at 300 m constitute a scientifically successful mission. Measurements would include analysis of meltwater for a few inorganic ions and amino acids and an optical examination of the borehole wall. 4) Communication. Transmission of data to an orbiter is essential, but we will constrain the landed mission to a daily communication over a few days. 5) Subsurface access. Drilling to 300 m is a significant challenge; it can be addressed by several means: Thermal Probe (Cryobot) which permits water to refreeze above the vehicle. This is our tentative choice with plutonium as the fuel to generate thermal energy for drilling and electrical power for operations. Open Hole Drill, a thermal system in which the meltwater is removed for greater thermal efficiency. Meltwater removal on Europa is both a complexity and a risk, but analysis is improved. Mechanical Drilling in which cutting or grinding generates ice chips which are removed. This is too complex at Europa temperatures. The measurement objectives for the mission will be: Obj. 1: Determine the concentration of simple inorganic salts in the Europa Ice Shell and, by extrapolation, of the ocean. These data will also validate spaceborne sensors. Obj. 2: Determine the nature and abundance of amino acids in the ice such that cometary infall material in the upper ice can be compared to material at depth. Obj. 3: Optically examine the ice to resolve inclusion structure, particulate content, and stratification. Access to 300 m depth is a significant if not audacious plan; we are aware that this has not been done on any planetary body. Our approach is the use of a plutonium heat source; to overcome Europa's surface temperature and to melt ice a significant amount of plutonium is needed, and significant shielding and other protective steps will be required. The quantity of plutonium is a key concern. The mission will require subsurface collection and processing of samples for in situ analysis, calling for a miniature, high pressure micro-sampling system designed to meet needs of instruments that require low presses for operation. The inlet system itself collects a micro-sample in the external high pressure environment, then transfers it into a protected low pressure environment for analysis.

Carsey, F. D.↗

Pulsed laser synthesis of mesoporous metal chalcogenide thin films

Mesoporous films of the metal chalcogenide B-FeSe were grown on MgO substrates by KrF pulsed laser deposition (PLD) in an argon background. At 100 mTorr, gated intensified charge-coupled device imaging and ion probe measurements showed that the plasma plume responsible for crystal growth initially comprised three components, with distinct expansion velocities. Plume interactions with the substrate heater and ablation target gave rise to complex dynamics, including collisions between the charged leading edge—rebounding between the substrate and the target—and slower-moving species in the plume interior. Film growth was dominated by species with kinetic energies ≤0.5 eV/atom. X-ray reflectivity revealed that films grown in this environment—with a substrate temperature of 350 ° C, a laser fluence of 1.0 J cm −2 , and a 7.5 mm 2 spot area—formed a porous framework with 15% porosity. Atomic force microscopy showed surface features that suggest pore sizes below 100 nm. X-ray diffraction indicated that the porous films were epitaxial with respect to the substrate and likely grew by oriented-attachment of gas-phase molecular clusters or very small nanoparticles, in contrast to the conventional epitaxy of vacuum films from atomic constituents. The in-plane orientation of the mesoporous films was B-FeSe [100]||[110] MgO, attributed to the soft landing of pre-formed crystallites on the MgO substrates, where protruding Se rows of B-FeSe aligned with corrugations of the MgO surface. In conclusion, this work implies that growth of candidate electrocatalyst materials by PLD in inert gas background may allow mesoporous frameworks with a single crystallographic orientation that expose specific crystal facets for electrochemical reactions and active site engineering.

cluster epitaxy↗

Characterization of Gas-Phase Native(-like) Proteins Using Structures for Lossless Ion Manipulations

High-resolution mobility-based ion separations in Structures for Lossless Ion Manipulations (SLIM) have been useful for ion mobility separations for a variety of molecular classes in the gas phase. Here, in this study, we present multipass SLIM separations for gas-phase proteins in their near-native state exhibiting charge-state-dependent arrival time distributions using carbonic anhydrase (29 kDa), alcohol dehydrogenase (148 kDa), and apo-transferrin (79 kDa). The experimental CCS values were obtained from calibration curves for the arrival times of Agilent Tune Mix ions. For multipass separations, the ATDs were converted to CCS values by deconvoluting the multipass arrival times into accurate single-pass values amenable to the single-pass calibration curves. Mass spectra of carbonic anhydrase (CA) showed three different charge states (z = 9+ to 11+). Their corresponding mobility peaks were baseline-separated by using 8-m single-pass separations. When compared to the corresponding drift tube ion mobility (DTIMS) measurements, the CCS values obtained from DTIMS and SLIM were in agreement within experimental error. Single-pass analysis of alcohol dehydrogenase (ADH) exhibits three predominant charge states (z = 23+ to 25+) with mobility overlap between adjacent charge states. The mobility peak resolution for ADH improved with multipass separations (up to 24-m path length). In addition, CCS distributions obtained for charge states z = 16+ to 18+ of apo-transferrin reveal a transition from a compact unimodal form (z = 18+ and 19+) to broader multimodal CCS distributions for z = 16+. For apo-transferrin, 40-m multipass separations were performed allowing for complete isolation of the selected mobility range corresponding to z = 17+, leading to selective isolation of a narrow arrival time window. The extended mobility separations provided minimal alterations to the structure of the proteins, and the experimentally derived CCS values showed minimal change as a function of the separation time or number of passes. Mobility-based ion separations for native-like proteins, using SLIM, open opportunities for native-IMS applications as well as other manipulations enabled by SLIM-like mobility-selective isolation and collection.

charge state distribution↗