Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Benzene, Toluene, and Xylene by means of an ion mobility spectrometer device using photoionization

The continuous monitoring of changes on the quality of ambient air is a field of advantage of ion mobility spectrometry. Benzene, Toluene, and Xylene are substances of special interest because of their toxicity. We present an optimized drift tube for ion mobility spectrometers, which uses photo-ionization tubes to produce the ions to be analyzed. The actual version of this drift tube has a length of 45 mm, an electric field strength established within the drift tube of about 180 V/cm and a shutter-opening-time of 400 mus. With the hydrogen tube used for ionisation a mean flux of 10(exp 12) photons/sq cm s was established for the experiments described. We discuss the results of investigations on Benzene, Toluene, and Xylene in normal used gasoline SUPER. The detection limits obtained with the ion mobility spectrometer developed in co-operation are in the range of 10 ppbv in this case. Normally, charge transfer from Benzene ions to Toluene takes place. Nevertheless the simultaneous determination in mixtures is possible by a data evaluation procedure developed for this case. The interferences found between Xylene and others are rather weak. The ion mobility spectra of different concentrations of gasoline SUPER are attached as an example for the resolution and the detection limit of the instrument developed. Resolution and sensitivity of the system are well demonstrated. A hand-held portable device produced just now is to be tested for special environmental analytical problems in some industrial and scientific laboratories in Germany.

Leonhardt, J. W.↗

Implementation of Ion Mobility Spectrometry-Based Separations in Structures for Lossless Ion Manipulations (SLIM)

Structures for Lossless Ion Manipulations (SLIM) is a powerful variant of traveling wave ion mobility spectrometry (TW-IMS) that uses a serpentine pattern of microelectrodes deposited onto printed circuit boards to achieve ultralong ion path lengths (13.5 m). Ions are propelled through SLIM platforms via arrays of TW electrodes while RF and DC electrodes provide radial confinement, establishing near lossless transmission. The recent ability to cycle ions multiple times through a SLIM has allowed ion path lengths to exceed 1000 m, providing unprecedented separation power and the ability to observe ion structural conformations unobtainable with other IMS technologies. The combination of high separation power, high signal intensity, and the ability to couple with mass spectrometry places SLIM in the unique position of being able to address longstanding proteomics and metabolomics challenges by allowing the characterization of isomeric mixtures containing low abundance analytes.

Hollerbach, Adam L.↗

Environment applications for ion mobility spectrometry

The detection of environmentally important polychlorinated aromatics by ion mobility spectrometry (IMS) was investigated. Single polychlorinated biphenyl (PCB) isomers (congeners) having five or more chlorine atoms were reliably detected in isooctane solution at levels of 35 ng with a Barringer IONSCAN ion mobility spectrometer operating in negative mode; limits of detection (LOD) were extrapolated to be in the low ng region. Mixtures of up to four PCB congeners, showing characteristic multiple peaks, and complex commercial mixtures of PCBs (Aroclors) were also detected. Detection of Aroclors in transformer oil was suppressed by the presence of the antioxidant BHT (2,6-di-t-butyl4-methylphenol) in the oil. The wood preservative pentachlorophenol (PCP) was easily detected in recycled wood shavings at levels of 52 ppm with the IONSCAN; the LOD was extrapolated to be in the low ppm region.

Ritchie, Robert K.↗

Ion Mobility Spectrometry-Mass Spectrometry for High-Throughput Analysis

Ion mobility spectrometry is a widely used analytical technique providing gas phase separation of molecules. It has received increasing attention in the recent years with the advancement in technology development and the availability of commercial instruments. In this chapter, we introduced the ion mobility fundamental theory and provided examples of IMS applications, especially for isomer separation, collision cross section database generation, high throughput analysis workflows, software tools for IMS data analysis, and ongoing high resolution SLIM IMS development. While IMS is not yet routinely utilized in drug discovery and pharmaceutical industry, there has been increased interest in high throughput library screening and antibody characterization. With all the ongoing development in IMS technology and informatics, we foresee more and more exciting applications of high throughput IMS analysis in different fields including omics studies, drug discovery and clinical applications in the near future.

Ross, Dylan H.↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Evaluating Material Design Principles for Calcium-Ion Mobility in Intercalation Cathodes

Multivalent-ion batteries offer an alternative to Li-based technologies, with the potential for greater sustainability, improved safety, and higher energy density, primarily due to their rechargeable system featuring a passivating metal anode. Although a system based on the Ca 2+ /Ca couple is particularly attractive given the low electrochemical plating potential of Ca 2+ , the remaining challenge for a viable rechargeable Ca battery is to identify Ca cathodes with fast ion transport. In this work, a high-throughput computational pipeline is adapted to (1) discover novel Ca cathodes in a largely unexplored space of empty intercalation hosts and (2) develop material design rules for Ca-ion mobility. One candidate from the screening, W 2 O 3 (PO 4 ) 2 , is confirmed to have a low Nudged Elastic Band (NEB) barrier of 168 meV within a one-dimensional (1D) ion percolation topology. This candidate is subsequently synthesized and electrochemically tested, achieving reversible Ca cycling with a capacity of 25 mA h/g. To further accelerate the screening for promising Ca intercalation electrodes, machine learning (ML) Random Forest (RF) and Extreme Gradient Boosting (XGB) classification models are created with local environment descriptors based on a large, structurally and chemically diverse dataset of minimum energy pathways, spanning over 5,000 density functional theory (DFT) site energy calculations. Accuracies of 92% are achieved, material design metrics are quantified, ML force-fields are leveraged in an accelerated iteration of the screening, and a total of 27 novel Ca cathode materials are highlighted for further investigation.

25 ENERGY STORAGE↗

Analysis of model Titan atmospheric components using ion mobility spectrometry

The Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS) was proposed as an analytical technique for the analysis of Titan's atmosphere during the Cassini Mission. The IMS is an atmospheric pressure, chemical detector that produces an identifying spectrum of each chemical species measured. When the IMS is combined with a GC as a GC-IMS, the GC is used to separate the sample into its individual components, or perhaps small groups of components. The IMS is then used to detect, quantify, and identify each sample component. Conventional IMS detection and identification of sample components depends upon a source of energetic radiation, such as beta radiation, which ionizes the atmospheric pressure host gas. This primary ionization initiates a sequence of ion-molecule reactions leading to the formation of sufficiently energetic positive or negative ions, which in turn ionize most constituents in the sample. In conventional IMS, this reaction sequence is dominated by the water cluster ion. However, many of the light hydrocarbons expected in Titan's atmosphere cannot be analyzed by IMS using this mechanism at the concentrations expected. Research at NASA Ames and PCP Inc., has demonstrated IMS analysis of expected Titan atmospheric components, including saturated aliphatic hydrocarbons, using two alternate sample ionizations mechanisms. The sensitivity of the IMS to hydrocarbons such as propane and butane was increased by several orders of magnitude. Both ultra dry (waterless) IMS sample ionization and metastable ionization were successfully used to analyze a model Titan atmospheric gas mixture.

Kojiro, D. R.↗

Development of Ion Mobility Spectrometry for Exobiology Flight Experiments

Ion Mobility Spectrometry (IMS) can provide gas chromatography with sample identification independent of sample retention time, with minimal interface. Initial commercial methods of IMS however, did not possess sufficient analytical capabilities and presented operational parameters which were unsuitable for exobiology missions. Subsequent development of IMS technology, with the focus on exobiology analytical requirements and mission imposed operational limitations, has produced an IMS interfaced with a GC capable of fulfilling the analytical requirements of several exobiology missions. Future exobiology missions will require further development of the IMS, particularly in the areas of overall instrument miniaturization and complex sample identification. The evolution of the exobiology focused IMS will be presented up to the current prototype design, which is a component of several proposed exobiology instruments. Areas of future development will also be discussed.

Kojiro, Daniel R.↗

Utilizing Ion-Mobility Data to Estimate Molecular Masses

A method is being developed for utilizing readings of an ion-mobility spectrometer (IMS) to estimate molecular masses of ions that have passed through the spectrometer. The method involves the use of (1) some feature-based descriptors of structures of molecules of interest and (2) reduced ion mobilities calculated from IMS readings as inputs to (3) a neural network. This development is part of a larger effort to enable the use of IMSs as relatively inexpensive, robust, lightweight instruments to identify, via molecular masses, individual compounds or groups of compounds (especially organic compounds) that may be present in specific environments or samples. Potential applications include detection of organic molecules as signs of life on remote planets, modeling and detection of biochemicals of interest in the pharmaceutical and agricultural industries, and detection of chemical and biological hazards in industrial, homeland-security, and industrial settings.

Duong, Tuan↗

FTP-Server for exchange, interpretation, and database-search of ion mobility spectra, literature, preprints and software

To assist current discussion in the field of ion mobility spectrometry, at the Institut fur Spectrochemie und angewandte Spektroskopie, Dortmund, start with 4th of December, 1994 work of an FTP-Server, available for all research groups at univerisities, institutes and research worker in industry. We support the exchange, interpretation, and database-search of ion mobility spectra through data format JCAMP-DS (Joint Committee on Atomic and Molecular Physical Data) as well as literature retrieval, pre-print, notice, and discussion board. We describe in general lines the entrance conditions, local addresses, and main code words. For further details, a monthly news report will be prepared for all common users. Internet email address for subscribing is included in document.

Baumbach, J. I.↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS): CRADA 410 (Final Report)

This document is the final report for CRADA 410 (Project No. 72496). The purpose of this project was supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. PNNL worked with Agilent to evaluate and improve the integration of ion mobility into existing MS data analysis methods of Agilent software tools. The project augmented PNNL’s capabilities to analyze complex omics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

97 MATHEMATICS AND COMPUTING↗

Classification of ion mobility spectra by functional groups using neural networks

Neural networks were trained using whole ion mobility spectra from a standardized database of 3137 spectra for 204 chemicals at various concentrations. Performance of the network was measured by the success of classification into ten chemical classes. Eleven stages for evaluation of spectra and of spectral pre-processing were employed and minimums established for response thresholds and spectral purity. After optimization of the database, network, and pre-processing routines, the fraction of successful classifications by functional group was 0.91 throughout a range of concentrations. Network classification relied on a combination of features, including drift times, number of peaks, relative intensities, and other factors apparently including peak shape. The network was opportunistic, exploiting different features within different chemical classes. Application of neural networks in a two-tier design where chemicals were first identified by class and then individually eliminated all but one false positive out of 161 test spectra. These findings establish that ion mobility spectra, even with low resolution instrumentation, contain sufficient detail to permit the development of automated identification systems.

Non-NASA Center↗

Electrochemical Reactions Under Reverse Bias Create Additional Mobile Ions That Enable Hole Tunneling in Metal Halide Perovskite Diodes

Gradual reverse-bias breakdown in metal-halide perovskite diodes and solar cells is thought to originate from hole tunneling through steep bands in an ionic depletion region near the electron-transport layer after positively charged iodine vacancies accumulate near the hole-transport layer (HTL). However, typical reported mobile-ion concentrations near 1 x 10^17 cm-3 are too small to quantitatively explain significant tunneling-current densities and (Zener) breakdown observed near -5 V. Here, we show that inferred mobile-ion concentrations increase by more than 100x, to over 1 x 10^18cm-3 , within just 3 min of reverse bias at -6.0 V in p-i-n perovskite diodes. We attribute this increase to iodide oxidation and coupled iodine vacancy creation that must be balanced by reduction reactions near the HTL. Sub-optimal HTL coverage leads to direct contact between the transparent conducting electrode and perovskite, facilitates reduction events, enables the creation of even larger inferred mobile-ion concentrations (~1 x 10^19cm-3 ), and leads to faster degradation under reverse bias. This explains previous work that showed increased breakdown voltages and improved reverse-bias stability by implementing thick, uniform HTLs.

14 SOLAR ENERGY↗

Quantitative analysis of volatile organic compounds using ion mobility spectra and cascade correlation neural networks

Ion Mobility Spectrometry (IMS) is a powerful technique for trace organic analysis in the gas phase. Quantitative measurements are difficult, because IMS has a limited linear range. Factors that may affect the instrument response are pressure, temperature, and humidity. Nonlinear calibration methods, such as neural networks, may be ideally suited for IMS. Neural networks have the capability of modeling complex systems. Many neural networks suffer from long training times and overfitting. Cascade correlation neural networks train at very fast rates. They also build their own topology, that is a number of layers and number of units in each layer. By controlling the decay parameter in training neural networks, reproducible and general models may be obtained.

Harrington, Peter DEB.↗

Proton-bound cluster ions in ion mobility spectrometry

Gaseous oxygen and nitrogen bases, both singly and as binary mixtures, have been introduced into ion mobility spectrometers to study the appearance of protonated molecules, and proton-bound dimers and trimers. At ambient temperature it was possible to simultaneously observe, following the introduction of molecule A, comparable intensities of peaks ascribable to the reactant ion (H2O)nH+, the protonated molecule AH+ and AH+ H2O, and the symmetrical proton bound dimer A2H+. Mass spectral identification confirmed the identifications and also showed that the majority of the protonated molecules were hydrated and that the proton-bound dimers were hydrated to a much lesser extent. No significant peaks ascribable to proton-bound trimers were obtained no matter how high the sample concentration. Binary mixtures containing molecules A and B, in some cases gave not only the peaks unique to the individual compounds but also peaks due to asymmetrical proton bound dimers AHB+. Such ions were always present in the spectra of mixtures of oxygen bases but were not observed for several mixtures of oxygen and nitrogen bases. The dimers, which were not observable, notable for their low hydrogen bond strengths, must have decomposed in their passage from the ion source to the detector, i.e. in a time less than approximately 5 ms. When the temperature was lowered to -20 degrees C, trimers, both homogeneous and mixed, were observed with mixtures of alcohols. The importance of hydrogen bond energy, and hence operating temperature, in determining the degree of solvation of the ions that will be observed in an ion mobility spectrometer is stressed. The possibility is discussed that a displacement reaction involving ambient water plays a role in the dissociation.

Non-NASA Center↗