Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inverter testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Deep Learning-Based Failure Prognostic Model for PV Inverter Using Field Measurements

Here, this study presents a novel approach for the precise monitoring and prognosis of photovoltaic (PV) inverter status, which is crucial for the proactive maintenance of PV systems. It addresses the gaps in traditional model-based methods, which tend to neglect the overall reliability of inverters, and the limitations of data-driven approaches that largely depend on simulated data. This research presents a robust solution applicable to real-world scenarios. The proposed data-driven model for PV inverter failure prognosis employs actual inverter measurements, integrating various operational and weather-related factors based on domain knowledge. This approach effectively represents inverter stressors and operational status. Utilizing an Enhanced Siamese Convolutional Neural Network (ESCNN), the model merges operational data with domain knowledge features, redefining the prognosis challenge as a classification task. Furthermore, the paper discusses an ESCNN-based real-time inverter failure monitoring method developed on the well-trained model. The proposed models are rigorously trained and tested with real inverter data and a novel filtering method is included to address accidental failures in practical scenarios. The results validate the model's efficacy, and the directions for future research are also outlined.

42 ENGINEERING↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

black start↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation: Preprint

Photovoltaic inverter (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. Due to this proprietary nature, it is not possible to share EMT domain models for system studies. This research work presents a novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to enhance the PV inverter modeling. We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests including voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data was used in learning-based model training. This learning-based model was imported into an Electromagnetic Transient (EMT) simulation tool using co-simulation techniques to complete the modeling effort and integrate the model into an EMT simulation tool. The three key components in this research work are the design of experimental setup, use of learning-based approach for model development and use of co-simulation to complete the approach. The proposed approach will allow users to develop a model in a really short period of time and achieve reasonable inverter models.

artificial intelligence↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments: Preprint

Existing state-of-the-art of single-phase grid-forming (GFM) inverter are primarily focused on electromagnetic transient simulation, and there are very few works performing hardware test, and there is no clear understanding how the single-phase GFM inverter should behave from a hardware perspective. Therefore, this paper addresses the gap by performing hardware experiment to evaluate the performance of a single-phase GFM hardware inverter. We enrich the existing GFM testing protocols by investigating transient performance of GFM inverters under different grid dynamic events, and quantifiable performance metrics are made to have a common understanding of expected performance of single-phase GFM inverters. A commercial single-phase GFM inverter is used to verify the test protocols and understand the inverter's performance and functionalities.

dynamic events↗

Multilevel Cybersecurity for Photovoltaic Systems

The motivation behind this project is to protect critical infrastructure in electric power generation pertaining to solar photovoltaic (PV) systems. This growing renewable energy resource is becoming a more vital part of the nation’s energy portfolio, particularly since it has achieved grid-parity to existing generation methods in terms of cost. It is thus vital that steps be taken to ensure the cybersecurity of these assets. The project goal was to devise a multilevel cybersecurity solution to address PV security gaps at the inverter and system levels, and field test the solution under the supervision and review of a US-based solar inverter manufacturer and PV installer/operator. A two-level cyberattack defense approach was formulated whereby the first level, the solar inverter level, hardens individual devices and achieves a deeply cyber-secure inverter. The inverter level security involves a multi-layer defense-in-depth approach for securing the inverter while also providing data for the system level algorithms. The second level, the system level, addresses intrusion detection and restoration involving an ensemble of inverters and relevant systems.

14 SOLAR ENERGY↗

Advancing Dynamic Modeling of Grid-Connected PV Inverter Using Bi-LSTM-Based AI Model

Power electronic converters (PECs) are widely used in modern power systems to facilitate the interconnection between various AC or DC sources and loads. Because of the extensive integration, the power system has grown into a more dynamic system in which the dynamics of the PECs must be adequately modeled. The paper presents a new bidirectional long short-term memory (Bi-LSTM) method for evaluating grid-connected inverter-based resources (IBR) dynamics. The method is tested using real hardware data from a grid -connected commercial inverter in laboratory experiments. Results show the Bi-LSTM model accurately reproduces the detailed IBR model's dynamics, even when the internal structure is unknown and parameters are unknown, preventing the disclosure of the manufacturer's confidential data.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Experiences and Lessons from Field Demonstration of Grid-forming Inverter in An AC Microgrid

The validation of GFM control strategies through simulation and hardware demonstration is important before their large-scale deployments in the real grid. Considering the importance of testing and validation, several works have explored the GFM inverter’s capability to blackstart a microgrid, synchronize and share loads, and interact with various types of generation sources and loads present in the grid. Herein, this paper complements the existing works by presenting the results and analysis of a field demonstration in an actual AC microgrid. The capability of a three-level neutral point clamped (NPC) GFM inverter equipped with a recursive feedback type of non-linear device level control to operate with PV source on its DC input and off-the-shelf PVGFL inverters and EV chargers of different kinds on the AC side is explored. The analysis and conclusions drawn would inform the readers to make better decisions during the field demonstration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2024 Photovoltaic Inverter Reliability Workshop Summary Report & Proceedings

The National Renewable Energy Laboratory (NREL) organized the 2024 Photovoltaic Inverter Reliability Workshop on April 11-12, 2024, hosted at NREL's South Table Mountain campus in Golden, Colorado. The workshop was organized around seven key topics, including the present state of inverter reliability; solutions for reliability challenges; life cycle cost and ownership issues; testing, standards, performance, and reliability metrics; data reporting, analytics, and sharing; and the future of PV inverter reliability research. Participants included inverter manufacturers, national laboratory researchers, academics, independent testing laboratories, and more. Over the course of the two-day workshop, attendees arrived at several key priorities and conclusions. This report summarizes these conclusions and then collects presentations from the workshop into a record of the workshop's proceedings.

14 SOLAR ENERGY↗

UNIFI Specifications for GFM IBRs (V3) and Transitioning to an IEEE Standard [Slides]

This presentation describes version 3 of the grid-forming (GFM) specifications for inverter-based resources developed by the UNIFI (Uniform Interoperability for Grid-Forming Inverters) Consortium. It summarizes the requirements for GFM inverters, the four categories of GFM capability, and the tests designed to assess GFM capability. The tests including time-domain tests similar to those in use by some industry entities and frequency-domain tests that are largely new. This presentation also describes ongoing efforts to use the UNIFI GFM specifications as the starting point for a new IEEE standard called IEEE P2800.1.

14 SOLAR ENERGY↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Scalable Solution for Grid Optimization and DER Integration (CRADA Final Report)

Utilidata Inc. is an energy software company that provides clean energy and digital solutions for utilities. This work was the result of Utilidata Inc. being awarded a New York State Energy Research and Development Agency award to integrate Utilidata volt-VAR optimization (VVO) software with smart inverters to explore enhanced voltage control. This project was conducted in partnership with Utilidata Inc., National Grid, the New York State Energy and Research Development Authority, and the National Renewable Energy Laboratory (NREL). As part of the project NREL conducted modeling and simulation analysis, developed cost-benefit analysis framework, and conducted laboratory testing to understand the potential for smart inverter integration to a centralized VVO control scheme. The remainder of the report provides an executive summary of the work, an introduction to the challenges, sections detailing specific aspects of the work, and the overall findings and conclusions.

14 SOLAR ENERGY↗