Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inventory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

2023 Annual Explosives Inventory Completion

The 2023 Lawrence Livermore National Laboratory (LLNL) annual explosives inventory was executed from May 18, 2023 to September 27, 2023 and was verified for accuracy effective September 28, 2023 following the LLNL Explosive Materials Inventory Plan. This year’s annual inventory includes changes incorporated based on the Department of Energy (DOE) Office of Inspector General (OIG) Audit Report DOE-OIG-20-50, The Department of Energy’s Storage and Disposition of Explosives Material at Selected Sites, dated July of 2020. Based on the associated recommendations, explosives at DOE and National Nuclear Safety Administration (NNSA) sites are considered "sensitive personal property" and applicable inventories must comply with 41 CFR 109, Personal Property Management. This regulation adds additional stipulations which require the annual inventory to include accountability of the total site inventory. In addition, the inventory must be performed by personnel other than the property owner, or alternatively must include independent verification. The development of the inventory plan was agreed to by the LLNL Explosives Safety Committee in conjunction with the LLNL Property and Business Division Leader. The LLNL Explosive Materials Inventory Plan was reviewed and approved by the DOE Explosives Safety Committee Chair on May 17, 2023 and by the NNSA Property Management Office on May 25, 2023.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interactive inventory monitoring

Method and system for monitoring present location and/or present status of a target inventory item, where the inventory items are located on one or more inventory shelves or other inventory receptacles that communicate with an inventory base station through use of responders such as RFIDs. A user operates a hand held interrogation and display (IAD) module that communicates with, or is part of, the base station, to provide an initial inquiry. Information on location(s) of the target inventory item is also indicated visibly and/or audibly on the receptacle(s) for the user. Status information includes an assessment of operation readiness and a time, if known, that the specified inventory item or class was last removed or examined or modified. Presentation of a user access level may be required for access to the target inventory item. Another embodiment provides inventory information for a stack as a sight-impaired or hearing-impaired person passes adjacent to that stack.

Spremo, Stevan M.↗

Evaluating Global Emission Inventories of Biogenic Bromocarbons

Emissions of halogenated very short-lived substances (VSLS) are poorly constrained. However, their inclusion in global models is required to simulate a realistic inorganic bromine (Bry) loading in both the troposphere, where bromine chemistry perturbs global oxidizing capacity, and in the stratosphere, where it is a major sink for ozone (O3). We have performed simulations using a 3-D chemical transport model (CTM) including three top-down and a single bottom-up derived emission inventory of the major brominated VSLS bromoform (CHBr3) and dibromomethane (CH2Br2). We perform the first concerted evaluation of these inventories, comparing both the magnitude and spatial distribution of emissions. For a quantitative evaluation of each inventory, model output is compared with independent long-term observations at National Oceanic and Atmospheric Administration (NOAA) ground-based stations and with aircraft observations made during the NSF (National Science Foundation) HIAPER Pole-to-Pole Observations (HIPPO) project. For CHBr3, the mean absolute deviation between model and surface observation ranges from 0.22 (38 %) to 0.78 (115 %) parts per trillion (ppt) in the tropics, depending on emission inventory. For CH2Br2, the range is 0.17 (24 %) to 1.25 (167 %) ppt. We also use aircraft observations made during the 2011 Stratospheric Ozone: Halogen Impacts in a Varying Atmosphere (SHIVA) campaign, in the tropical western Pacific. Here, the performance of the various inventories also varies significantly, but overall the CTM is able to reproduce observed CHBr3 well in the free troposphere using an inventory based on observed sea-to-air fluxes. Finally, we identify the range of uncertainty associated with these VSLS emission inventories on stratospheric bromine loading due to VSLS (Br(VSLS/y)). Our simulations show Br(VSLS/y) ranges from approximately 4.0 to 8.0 ppt depending on the inventory. We report an optimized estimate at the lower end of this range (approximately 4 ppt) based on combining the CHBr3 and CH2Br2 inventories which give best agreement with the compilation of observations in the tropics.

bromocarbons↗

Gridded National Inventory of U.S. Methane Emissions

We present a gridded inventory of US anthropogenic methane emissions with 0.1 deg x 0.1 deg spatial resolution, monthly temporal resolution, and detailed scale dependent error characterization. The inventory is designed to be onsistent with the 2016 US Environmental Protection Agency (EPA) Inventory of US Greenhouse Gas Emissionsand Sinks (GHGI) for 2012. The EPA inventory is available only as national totals for different source types. We use a widerange of databases at the state, county, local, and point source level to disaggregate the inventory and allocate the spatial and temporal distribution of emissions for individual source types. Results show large differences with the EDGAR v4.2 global gridded inventory commonly used as a priori estimate in inversions of atmospheric methane observations. We derive grid-dependent error statistics for individual source types from comparison with the Environmental Defense Fund (EDF) regional inventory for Northeast Texas. These error statistics are independently verified by comparison with the California Greenhouse Gas Emissions Measurement (CALGEM) grid-resolved emission inventory. Our gridded, time-resolved inventory provides an improved basis for inversion of atmospheric methane observations to estimate US methane emissions and interpret the results in terms of the underlying processes.

Methane↗

Effects of Inventory Bias on Landslide Susceptibility Calculations

Many landslide inventories are known to be biased, especially inventories for large regions such as Oregon's SLIDO or NASA's Global Landslide Catalog. These biases must affect the results of empirically derived susceptibility models to some degree. We evaluated the strength of the susceptibility model distortion from postulated biases by truncating an unbiased inventory. We generated a synthetic inventory from an existing landslide susceptibility map of Oregon, then removed landslides from this inventory to simulate the effects of reporting biases likely to affect inventories in this region, namely population and infrastructure effects. Logistic regression models were fitted to the modified inventories. Then the process of biasing a susceptibility model was repeated with SLIDO data. We evaluated each susceptibility model with qualitative and quantitative methods. Results suggest that the effects of landslide inventory bias on empirical models should not be ignored, even if those models are, in some cases, useful. We suggest fitting models in well-documented areas and extrapolating across the study region as a possible approach to modeling landslide susceptibility with heavily biased inventories.

Oregon↗

Effects of Inventory Bias on Landslide Susceptibility Calculations

Many landslide inventories are known to be biased, especially inventories for large regions such as Oregons SLIDO or NASAs Global Landslide Catalog. These biases must affect the results of empirically derived susceptibility models to some degree. We evaluated the strength of the susceptibility model distortion from postulated biases by truncating an unbiased inventory. We generated a synthetic inventory from an existing landslide susceptibility map of Oregon, then removed landslides from this inventory to simulate the effects of reporting biases likely to affect inventories in this region, namely population and infrastructure effects. Logistic regression models were fitted to the modified inventories. Then the process of biasing a susceptibility model was repeated with SLIDO data. We evaluated each susceptibility model with qualitative and quantitative methods. Results suggest that the effects of landslide inventory bias on empirical models should not be ignored, even if those models are, in some cases, useful. We suggest fitting models in well-documented areas and extrapolating across the study region as a possible approach to modelling landslide susceptibility with heavily biased inventories.

landslide↗

Approach to startup inventory for viable commercial fusion power plant

With the increasing efforts to commercialize fusion power, private and government organizations are investing heavily in the development of technology to support a viable fusion power plant. Deuterium-Tritium (DT) fueled reactors are more prevalent than other proposed designs, requiring tritium processing and handling technology for safe operations and self-sufficiency. Further, each fusion power plant will need a specific-to-design startup inventory of tritium to begin operations. This startup inventory is required prior to breeding and is the minimum tritium inventory required to fill each processing component in the fuel cycle, to offset radioactive decay losses, and to avoid a zero-fuel situation for continuous operation. We present an approach to calculate the startup tritium inventory for a 500 MW th reactor, with considerations for reserve inventory for maintenance and commissioning. A baseline startup inventory was calculated to be approximately 327 gs. This value was obtained using modest assumptions about the technology and operating parameters of a fusion power plant. The required operating reserve inventory or the inventory necessary to keep a fusion power plant operational using only direct internal recycling for 24 h for the same plant design is approximately 642 gs. The approach and findings of this paper will enable fusion energy stakeholders to better utilize the existing scarce global tritium supply.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Updates to the Hanford Soil Inventory Model (SIM Version 2) for FY 2023

The purpose of this environmental calculation file (ECF) is to document the updates made to the Soil Inventory Model version 2.1 (SIM-v2.1) (ECF-HANFORD-21-0073, Updates to the Hanford Soil Inventory Model (SIM Version 2) for FY 2021) in FY 2023. These updates to SIM-v2.1 are referred to as the SIM-v2.2 version. The following updates have been made: • Include inventory estimate for a new analyte • hexavalent chromium (Cr(VI)), separate from total chromium inventory • Revise the inventory discharged to the 216-U-10 and 216-T-4 Pond systems based on partitioning of waste streams discharges over time and space among influent ditches and ponds • Enhance the preprocessing and postprocessing of the input and output files Note that the methodology for estimating Cr(VI) inventories is based on ECF-200W-23-0040, Recommendations for Updating Liquid Discharged Inventory and Transport Modeling Parameters for Cumulative Impacts Evaluation of Hexavalent Chromium in the 200 West Area while the revision of inventory discharged to the 216-U-10 and 216-T-4 Pond systems is based on ECF-HANFORD-19-0032, Distribution of Infiltration in the 216-U-10, 216-B-3 Pond, and 216-T-4 Pond Systems 1944-1997.

54 ENVIRONMENTAL SCIENCES↗

Leveraging Radiofrequency Identification Success Beyond Hazardous Material Inventory Management at a National Laboratory

Effective inventory management can be overshadowed by conflicting priorities in organizational procedures, particularly in research-focused institutions such as national laboratories that handle expensive, delicate, and hazardous materials. Here, this study investigated the potential of radiofrequency identification (RFID) technology, currently used for hazardous chemical inventory, in applications with higher metal interference and absorption, specifically pressure release device (PRD) compliance and nuclear container management, at Lawrence Livermore National Laboratory (LLNL). This study was done to document best practices to enhance inventory identification speeds for inventory reconciliation and inventory recall and to explore optimal configurations for RFID implementation compared to traditional manual methods of equipment management. Tests were conducted to determine the ideal RFID tag orientation (read at angles of 0°, 90°, and 270°), various container layouts (linear, separated, curved, operational), and ID methods such as manual, barcode, and RFID performing three trials per method per orientation. Results indicated that 0° was the optimal read angle for minimizing metallic interference, and the operational and curved arrangements significantly outperformed the linear and separated configurations in read speed. 3D printed mounts were developed and tested, increasing the read range of the RFID reader by up to 235% in cases of high metallic interference. The RFID technology demonstrated an average speed increase of 65% over a simplified manual identification, which supports the conclusion that RFID is a more efficient method for large hazardous inventory management and equipment reconciliation. Additionally, capturing meta-data, such as location and date, can be used to query for inventory recall and automated updating of record information.

42 ENGINEERING↗

Interactive Inventory Monitoring

Method and system for monitoring present location and/or present status of a target inventory item, where the inventory items are located on one or more inventory shelves or other inventory receptacles that communicate with an inventory base station through use of responders such as RFIDs. A user operates a hand held interrogation and display (lAD) module that communicates with, or is part of the base station to provide an initial inquiry. lnformation on location(s) of the larget invenlory item is also indicated visibly and/or audibly on the receptacle(s) for the user. Status information includes an assessment of operation readiness and a time, if known, that the specified inventory item or class was last removed or examined or modified. Presentation of a user access level may be required for access to the target inventgory item. Another embodiment provides inventory informatin for a stack as a sight-impaired or hearing-impaired person adjacent to that stack.

rfid↗

Unified Communications for Space Inventory Management

To help assure mission success for long-duration exploration activities, NASA is actively pursuing wireless technologies that promote situational awareness and autonomy. Wireless technologies are typically extensible, offer freedom from wire tethers, readily support redundancy, offer potential for decreased wire weight, and can represent dissimilar implementation for increased reliability. In addition, wireless technologies can enable additional situational awareness that otherwise would be infeasible. For example, addition of wired sensors, the need for which might not have been apparent at the outset of a program, night be extremely costly due in part to the necessary routing of cables through the vehicle. RFID, or radio frequency identification, is a wireless technology with the potential for significant savings and increased reliability and safety in space operations. Perhaps the most obvious savings relate to the application of inventory management. A fully automated inventory management system is highly desirable for long-term sustaining operations in space environments. This assertion is evidenced by inventory activities on the International Space Station, which represents the most extensive inventory tracking experience base in the history of space operations. In the short tern, handheld RFID readers offer substantial savings owing to reduced crew time for inventory audits. Over the long term, a combination of improved RFID technology and operational concepts modified to fully utilize the technology should result in space based inventory management that is highly reliable and requires very little crew time. In addition to inventory management, RFID is likely to find space applications in real-time location and tracking systems. These could vary from coarse-resolution RFID portals to the high resolution afforded by ultra-wideband (UWB) RFID. Longer range RFID technologies that leverage passive surface acoustic wave (SAW) devices are being investigated to track assets on a lunar or planetary surface.

Gifford, Kevin K.↗

A New Global Anthropogenic SO2 Emission Inventory for the Last Decade: A Mosaic of Satellite-Derived and Bottom-Up Emissions

Sulfur dioxide (SO2) measurements from the Ozone Monitoring Instrument (OMI) satellite sensor have been used to detect emissions from large point sources. Emissions from over 400 sources have been quantified individually based on OMI observations, accounting for about a half of total reported anthropogenic SO2 emissions. Here we report a newly developed emission inventory, OMI-HTAP, by combining these OMI-based emission estimates and the conventional bottom-up inventory, HTAP, for smaller sources that OMI is not able to detect. OMI-HTAP includes emissions from OMI-detected sources that are not captured in previous leading bottom-up inventories, enabling more accurate emission estimates for regions with such missing sources. In addition, our approach offers the possibility of rapid updates to emissions from large point sources that can be detected by satellites. Our methodology applied to OMI-HTAP can also be used to merge improved satellite-derived estimates with other multi-year bottom-up inventories, which may further improve the accuracy of the emission trends. OMI-HTAP SO2 emissions estimates for Persian Gulf, Mexico, and Russia are 59%, 65%, and 56% larger than HTAP estimates, respectively, in year 2010. We have evaluated the OMI-HTAP inventory by performing simulations with the Goddard Earth Observing System version 5 (GEOS-5) model. The GEOS-5 simulated SO2 concentrations driven by both HTAP and OMI-HTAP were compared against in situ measurements. We focus for the validation on year 2010 for which HTAP is most valid and for which a relatively large number of in situ measurements are available. Results show that the OMI-HTAP inventory improves the agreement between the model and observations, in particular over the US, with the normalized mean bias decreasing from 0.41 (HTAP) to -0.03 (OMI-HTAP) for year 2010. Simulations with the OMI-HTAP inventory capture the worldwide major trends of large anthropogenic SO2 emissions that are observed with OMI. Correlation coefficients of the observed and modelled surface SO2 in 2014 increase from 0.16 (HTAP) to 0.59 (OMI-HTAP) and the normalized mean bias dropped from 0.29 (HTAP) to 0.05 (OMI-HTAP), when we updated 2010 HTAP emissions with 2014 OMI-HTAP emissions in the model.

Sulfur dioxide (SO2)↗

A System for Standardizing and Combining U.S. Environmental Protection Agency Emissions and Waste Inventory Data

The U.S. Environmental Protection Agency (USEPA) provides databases that agglomerate data provided by companies or states reporting emissions, releases, wastes generated, and other activities to meet statutory requirements. These databases, often referred to as inventories, can be used for a wide variety of environmental reporting and modeling purposes to characterize conditions in the United States. Yet, users are often challenged to find, retrieve, and interpret these data due to the unique schemes employed for data management, which could result in erroneous estimations or double-counting of emissions. To address these challenges, a system called Standardized Emission and Waste Inventories (StEWI) has been created. The system consists of four python modules that provide rapid access to USEPA inventory data in standard formats and permit filtering and combination of these inventory data. When accessed through StEWI, reported emissions of carbon dioxide to air and ammonia to water are reduced approximately two- and four-fold, respectively, to avoid duplicate reporting. StEWI will greatly facilitate the use of USEPA inventory data in chemical release and exposure modeling and life cycle assessment tools, among other things. To date, StEWI has been used to build the recent USEEIO model and the baseline electricity life cycle inventory database for the Federal LCA Commons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium inventory tracking as a non-destructive battery evaluation and monitoring method

Tracking the active lithium (Li) inventory in an electrode shows the true state of a Li battery, akin to a fuel gauge for an engine. However, non-destructive Li inventory tracking is currently unavailable. Here, in this work, we used the theoretical capacity of a transition metal oxide to convert capacity into a Li inventory analysis. The Li inventory in electrodes was tracked reliably to show how battery formulations and test methods affect performance. Contrary to capacity, Li inventory tracking reveals stoichiometric variations near the electrode–electrolyte interface. Verifiable results rationalized differences in measurements, clarifying and reducing interferences from cell formulations and experimental manipulations. By tracing four variables from formation to end-of-life, we characterize electrode and cell performance with a thermodynamic framework. Accurate rationalization of subtle differences in Li inventory utilization promises precise battery engineering, evaluation, failure analysis and risk mitigation. The method could be applicable from cell design optimization and fabrication to battery management, improving battery performance and reliability.

25 ENERGY STORAGE↗

Opinion: Coordinated development of emission inventories for climate forcers and air pollutants

Emissions into the atmosphere of fine particulate matter, its precursors, and precursors to tropospheric ozone impact not only human health and ecosystems, but also the climate by altering Earth's radiative balance. Accurately quantifying these impacts across local to global scales historically and in future scenarios requires emission inventories that are accurate, transparent, complete, comparable, and consistent. In an effort to better quantify the emissions and impacts of these pollutants, also called short-lived climate forcers (SLCFs), the Intergovernmental Panel on Climate Change (IPCC) is developing a new SLCF emissions methodology report. This report would supplement existing IPCC reporting guidance on greenhouse gas (GHG) emission inventories, which are currently used by inventory compilers to fulfill national reporting requirements under the United Nations Framework Convention on Climate Change (UNFCCC) and new requirements of the Enhanced Transparency Framework (ETF) under the Paris Agreement starting in 2024. We review the relevant issues, including how air pollutant and GHG inventory activities have historically been structured, as well as potential benefits, challenges, and recommendations for coordinating GHG and air pollutant inventory efforts. We argue that, while there are potential benefits to increasing coordination between air pollutant and GHG inventory development efforts, we also caution that there are differences in appropriate methodologies and applications that must jointly be considered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How Well Does the Present Surface Inventory of Water on Mars Constrain the Past?

Over the past 40 years, estimates of the total outgassed inventory of water on Mars have ranged from a global equivalent layer (GEL) approximately 7-1000 m deep. However, Carr and Head have recently argued that it is not the total inventory of outgassed water that is important, but the amount that exists in climatically exchangeable surface and near surface reservoirs - suggesting that any exchange with water in the deep subsurface is precluded by the existence of a thick cryosphere, at least during the Amazonian and Hesperian. Based on this assumption and their estimate of the present day near-surface inventory of H2O (approximately 34 m GEL, stored as ice in the polar layered deposits (PLD), lobate debris aprons, ice-rich latitude dependent mantles, and as shallow ground ice), they extrapolate the evolution of this inventory backward in time, taking into account the introduction of new water by volcanism, outflow channel activity, and the loss of water by exospheric escape. They conclude that, at the end of the Noachian, Mars had a near-surface water inventory of approximately 24 m and approximately 62 m by the end of the Hesperian - inventories that Carr and Head argue were incompatible with the existence of a former ocean.

Clifford, S. M.↗

Detection of local-scale changes in greenhouse gas emissions in urban environments using micrometeorological methods and comparison to a high-resolution inventory

We used the Monin–Obukhov similarity theory (MOST) flux-variance relationship to estimate greenhouse gas (GHG) fluxes from high-precision mole fraction measurements at 3 instrumented urban communication towers over several years, demonstrating the ability of this method to detect and quantify changes in emissions. Depending on data availability, we used carbon dioxide (CO 2 ) and carbon monoxide (CO) measurements and/or tracer ratios to estimate fluxes at 1 urban site (Site 3) and 1 suburban site (Site 7) in Indianapolis, IN, USA, and 1 urban site (COM) in Los Angeles, CA, USA. We also compared the estimated fluxes of CO 2 from fossil fuel sources (CO 2 ff) at Sites 3 and 7 and the total CO 2 fluxes at Site 3 to 20 m, hourly resolution subdomains of the high-resolution CO 2 emissions inventory, Hestia, for the year 2020, introducing a new way to evaluate emissions inventories at small spatial and temporal scales. Using the flux-variance relationship, we detected and quantified abrupt decreases in CO and CO 2 fluxes at Site 3 and COM in April 2020, coinciding with the stay-at-home order due to COVID-19 pandemic, as well as abrupt decreases in CO and CO 2 fluxes at Site 3 in July 2018 coinciding with a highway closure next to the site. The Hestia emissions inventory detected a decrease in emissions in April 2020 at Sites 3 and 7, but this decrease differed in magnitude from those detected in the atmospheric estimates. Seasonal trends in emissions are similar between Hestia and the atmospheric estimates at Site 7. We use differences in seasonal and spatial trends between the flux estimation methods to identify potential sources of uncertainty in both the atmospheric and inventory methods. The results from this study show that the flux-variance estimation method is a useful tool to monitor local-scale emissions and evaluate high-resolution emissions inventories.

Carbon dioxide↗

Automated Medical Inventory System (AMIS) TechPort Entry

The current medical inventory paradigm on the International Space Station (ISS) requires crew to report use of medications and supplies to be manually decremented by ground teams. This method is not only tedious and time consuming for both the crew and ground teams but also results in inaccuracies in location and availability of medical supplies over time. Fortunately, the ISS is frequently resupplied by cargo launches and crew expeditions, and an accurate inventory count is less critical. However, for exploration missions, resupply will be greatly limited or unavailable entirely, and increasing communication latency will impair crew-ground communications. On longer missions, with large medical systems and time constrained crew, NASA needs a method of accurately managing medical inventory without reliance on ground teams and with as little crew time and effort as possible. The Exploration Medical Integrated Product Team (XMIPT) project called Medical Exploration Development and Implementation Scoping (MEDIScope) prepared a concept of operations and preliminary requirements for an Automated Medical Inventory System (AMIS) and completed a market survey and trade study of potential inventory management technologies in partnership with the market research firm, yet2. The products from the MEDIScope effort, including the market survey results, preliminary functional requirements and a concept of operations, have been handed off to a development team at Glenn Research Center (GRC) and ZIN Technologies for technology maturation. In the development phase, the AMIS team will finalize system requirements, down select technologies, integrate with a future exploration Crew Health and Performance Integrated Data Architecture, and conduct design reviews. The project will culminate in an ISS technical flight demonstration in FY27.

MEDIScope↗