Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intrusion detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SHARP-Net: Platform for Self-Healing and Attack Resilient PMU Networks

Synchrophasor technology plays a pivotal role in developing the next generation of wide-area monitoring, protection, and control in the smart grid environment. As technology and communications infrastructures evolve, however, so do the attack surfaces in the synchrophasor network that can be exploited by advanced persistent threat (APT) actors to affect power system stability and reliability. In this paper, we propose a novel platform for developing a self-healing and attack-resilient PMU network (SHARP-Net) by instituting a state-of-the-art intrusion detection system (IDS) with an intrusion mitigation system (IMS) and an alert management system (AMS). In particular, the proposed platform detects anomalies during cyberattacks on phasor data concentrators (PDCs) based on the rules defined in the IDS, then the generated alerts are published to the IMS through the AMS. The proposed IMS proceeds to take automated corrective responses to mitigate cyberattacks by reconfiguring the synchrophasor network to isolate the compromised PDCs, and it orchestrates new PDCs to prevent the future propagation of attacks. Further, the IMS restores the system's observability by reconnecting the new PDCs to make the grid attack-resilient. In this work, the SHARP-Net platform is developed by using Python-based libraries, minimega's software-defined network, and virtual machine orchestration. We implement and validate the proposed SHARP-Net architecture by testing a PMU network in the smart grid environment. SHARP-Net showed promising performance in detecting cyberattacks and mitigating them through the network reconfiguration.

computer architecture↗

Inter-Domain Fusion for Enhanced Intrusion Detection in Power Systems: An Evidence Theoretic and Meta-Heuristic Approach

False alerts due to misconfigured or compromised intrusion detection systems (IDS) in industrial control system (ICS) networks can lead to severe economic and operational damage. However, research using deep learning to reduce false alerts often requires the physical and cyber sensor data to be trustworthy. Implicit trust is a major problem for artificial intelligence or machine learning (AI/ML) in cyber-physical system (CPS) security, because when these solutions are most urgently needed is also when they are most at risk (e.g., during an attack). To address this, the Inter-Domain Evidence theoretic Approach for Inference (IDEA-I) is proposed that reframes the detection problem as how to make good decisions given uncertainty. Specifically, an evidence theoretic approach leveraging Dempster–Shafer (DS) combination rules and their variants is proposed for reducing false alerts. A multi-hypothesis mass function model is designed that leverages probability scores obtained from supervised-learning classifiers. Using this model, a location-cum-domain-based fusion framework is proposed to evaluate the detector’s performance using disjunctive, conjunctive, and cautious conjunctive rules. The approach is demonstrated in a cyber-physical power system testbed, and the classifiers are trained with datasets from Man-In-The-Middle attack emulation in a large-scale synthetic electric grid. For evaluating the performance, we consider plausibility, belief, pignistic, and general Bayesian theorem-based metrics as decision functions. To improve the performance, a multi-objective-based genetic algorithm is proposed for feature selection considering the decision metrics as the fitness function. Finally, we present a software application to evaluate the DS fusion approaches with different parameters and architectures.

42 ENGINEERING↗

ThunderSecure: deploying real-time intrusion detection for 100G research networks by leveraging stream-based features and one-class classification network

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks (40/100G) across distributed sites for processing, storage, and analysis. Like general purpose networks, research networks experience intrusions. However, monitoring anomalies in such high-speed network traffics is challenging given current cyber-infrastructure. Moreover, traditional network intrusion detection systems (NIDS) are signature based. However, anomaly patterns are difficult to define and that rulesets are often not updated frequently enough to reflect the changes of attack behaviors. We present ThunderSecure, a high-throughput, unsupervised learning-based intrusions detection system for 100G research networks. ThunderSecure implements an efficient packet processing and detection pipeline using multi-cores and GPUs. It extracts statistical and temporal features from real-time network data streams and feeds them to a one-class anomaly detection network. A baseline of normal distribution will be created based on the training observation. Testing traffic deviated from the learned profile will be marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets mirrored from two 100G network connections at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. Results show that ThunderSecure can recognize science data traffic captured long after the training and made nearly certain detection on the segment of the streams where anomalous flows were injected.

100G research network↗

Review of Intrusion Detection Methods and Tools for Distributed Energy Resources

Recent trends in the growth of distributed energy resources (DER) in the electric grid and newfound malware frameworks that target internet of things (IoT) devices is driving an urgent need for more reliable and effective methods for intrusion detection and prevention. Cybersecurity intrusion detection systems (IDSs) are responsible for detecting threats by monitoring and analyzing network data, which can originate either from networking equipment or end-devices. Creating intrusion detection systems for PV/DER networks is a challenging undertaking because of the diversity of the attack types and intermittency and variability in the data. Distinguishing malicious events from other sources of anomalies or system faults is particularly difficult. New approaches are needed that not only sense anomalies in the power system but also determine causational factors for the detected events. In this report, a range of IDS approaches were summarized along with their pros and cons. Using the review of IDS approaches and subsequent gap analysis for application to DER systems, a preliminary hybrid IDS approach to protect PV/DER communications is formed in the conclusion of this report to inform ongoing and future research regarding the cybersecurity and resilience enhancement of DER systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Leveraging High-Fidelity Datasets for Machine Learning-based Anomaly Detection in Smart Grids

Data-driven intrusion detection systems are increasingly becoming essential for protecting critical cyber-physical infrastructure, such as the power grid, against the growing number of sophisticated cyber-attacks. The development of such tools is reliant on the availability of high-fidelity cyber-physical datasets that cover a diverse variety of potential cyber events. In this work, a high-fidelity smart grid platform is utilized to develop an extensive dataset, which is used to train and test a machine learning-based intrusion detection system. The evaluation of the developed IDS shows robust performance even when tested with statistically diverse test data not used in training.

Hyder, Burhan↗

Modeling Data Flows with Network Calculus in Cyber-Physical Systems: Enabling Feature Analysis for Anomaly Detection Applications

The electric grid is becoming increasingly cyber-physical with the addition of smart technologies, new communication interfaces, and automated grid-support functions. Because of this, it is no longer sufficient to only study the physical system dynamics, but the cyber system must also be monitored as well to examine cyber-physical interactions and effects on the overall system. To address this gap for both operational and security needs, cyber-physical situational awareness is needed to monitor the system to detect any faults or malicious activity. Techniques and models to understand the physical system (the power system operation) exist, but methods to study the cyber system are needed, which can assist in understanding how the network traffic and changes to network conditions affect applications such as data analysis, intrusion detection systems (IDS), and anomaly detection. In this paper, we examine and develop models of data flows in communication networks of cyber-physical systems (CPSs) and explore how network calculus can be utilized to develop those models for CPSs, with a focus on anomaly and intrusion detection. This provides a foundation for methods to examine how changes to behavior in the CPS can be modeled and for investigating cyber effects in CPSs in anomaly detection applications.

97 MATHEMATICS AND COMPUTING↗

Cyber-physical Architecture For Automated Responses (cyphar) In Adversarial Ot Environments

The ability to react to a malicious attack starts with high fidelity recognition, and with that, an agile response to the attack. The current operational technology (OT) systems for a critical infrastructure may include an intrusion detection system (IDS), but the ability to adapt to an intrusion is a human initiated response. Orchestrators, which are coming of age in the financial sector and allow for levels of automated response, are not prevalent in the OT space. To evolve to such responses in the OT space, a tradeoff analysis is first needed, The tradeoff analysis, which evaluates the mitigation benefits of responses versus the physical affects that result, inform an automated response decision. The intent of this paper is to provide a formulation of a tradeoff analysis and its use in advancing automated, agile responses.

Rieger, CraigG.↗

Malware analysis and recovery

A system and method detects malware by processing notifications from an intrusion detection system and baseline snapshots from an image capture utility. The image capture utility constructs an image of the suspected malware intrusion and links the suspected malware intrusion to the baseline snapshots. The system and method propagates the image of the suspected malware intrusion across multiple networks before it distinguishes malicious code, device state, and files from benign code, device state, and files. Some systems and methods include a malware recovery system that executes machine learning instructions and heuristics to revert a client and/or a remote server to one or more baseline snapshots.

Smith, Jared M.↗

Twenty Years and Counting—Where are they? Practical Recommendations for Commercializing AI/ML for Intrusion Detection in the Nuclear Industry

Research and development into applications for improving equipment condition monitoring programs at nuclear facilities has been around since the 1990s. However, while the field has moved from using data-driven machine learning (ML) algorithms for detection and prediction of equipment degradation and failure to prognostic capabilities, these applications are still not widely used in the U.S. nuclear industry. Additionally, there has been significant effort in designing both data-driven and physics-based artificial intelligence (AI) and ML models for many other potential applications in the nuclear industry, including cyber intrusion detection systems (IDS). However, as the last twenty years in condition-based maintenance research has shown us, there are significant hurdles that must be overcome for deployment of IDS on plant systems. This paper provides a discussion on the practical recommendations that researchers should consider for successful adoption of AI/ML IDS in the nuclear industry.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detecting Masquerade Attacks in Controller Area Networks Using Graph Machine Learning

Modern vehicles rely on a myriad of electronic control units (ECUs) interconnected via controller area networks (CANs) for critical operations. Despite their ubiquitous use and reliability, CANs are susceptible to sophisticated cyberattacks, particularly masquerade attacks, which inject false data that mimic legitimate messages at the expected frequency. These attacks pose severe risks such as unintended acceleration, brake deactivation, and rogue steering. Traditional intrusion detection systems (IDS) often struggle to detect these subtle intrusions due to their seamless integration into normal traffic. This paper introduces a novel framework for detecting masquerade attacks in the CAN bus using graph machine learning (ML). We hypothesize that the integration of shallow graph embeddings with time series features derived from CAN frames enhances the detection of masquerade attacks. We show that by representing CAN bus frames as message sequence graphs (MSGs) and enriching each node with contextual statistical attributes from time series, we can enhance detection capabilities across various attack patterns compared to using graph-based features only. Our method ensures a comprehensive and dynamic analysis of CAN frame interactions, improving robustness and efficiency. Extensive experiments on the ROAD dataset validate the effectiveness of our approach, demonstrating statistically significant improvements in the detection rates of masquerade attacks compared to a baseline that uses graph-based features only as confirmed by Mann-Whitney U and Kolmogorov-Smirnov tests (p < 0.05) .

Marfo, William [Univ. of Texas, El Paso, TX (Unite↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗

IoT Intrusion Detection Taxonomy, Reference Architecture, and Analyses

This paper surveys the deep learning (DL) approaches for intrusion-detection systems (IDSs) in Internet of Things (IoT) and the associated datasets toward identifying gaps, weaknesses, and a neutral reference architecture. A comparative study of IDSs is provided, with a review of anomaly-based IDSs on DL approaches, which include supervised, unsupervised, and hybrid methods. All techniques in these three categories have essentially been used in IoT environments. To date, only a few have been used in the anomaly-based IDS for IoT. For each of these anomaly-based IDSs, the implementation of the four categories of feature(s) extraction, classification, prediction, and regression were evaluated. We studied important performance metrics and benchmark detection rates, including the requisite efficiency of the various methods. Four machine learning algorithms were evaluated for classification purposes: Logistic Regression (LR), Support Vector Machine (SVM), Decision Tree (DT), and an Artificial Neural Network (ANN). Therefore, we compared each via the Receiver Operating Characteristic (ROC) curve. The study model exhibits promising outcomes for all classes of attacks. The scope of our analysis examines attacks targeting the IoT ecosystem using empirically based, simulation-generated datasets (namely the Bot-IoT and the IoTID20 datasets).

97 MATHEMATICS AND COMPUTING↗

Bayesian GAN-Based False Data Injection Attack Detection in Active Distribution Grids With DERs

Advancements in information and communication technologies have revolutionized monitoring and control capabilities within smart grids. However, it also brings new vulnerabilities to data acquisition systems and state estimation functions, which attackers can subtly tamper with the measurement data through compromising the communication network. Moreover, the high penetration of renewable energy sources with the inherited characteristics of uncertainty and variability further complicates the design of effective intrusion detection systems. In this paper, a Bayesian deep learning-based approach is developed to detect cyber attacks and maintain the security of smart grids. Our method specifically addresses the prevalent issue of imbalanced data in real power systems, which arises from the predominance of normal system operations over compromised or attacked states. Employing a novel Bayesian GAN-based technique, our approach successfully discriminates between secure and compromised measurement data, even in scenarios with significant data imbalance. Furthermore, the proposed method accommodates various practical application factors, ensuring accurate intrusion detection despite the presence of measurement noise. The feasibility and effectiveness of the proposed detection mechanism are validated by testing on IEEE 13-node and 123-node test systems. Simulation results and comparisons with literature methods demonstrate the superiority of proposed cybersecurity solutions.

Bayesian GAN↗

Laika BOSS (Binary Object Scanning System)

Laika BOSS (Binary Object Scanning System), often written as "Laikaboss", is an object scanner and intrusion detection system that strives to be scalable, flexible, and verbose. Its goal is to take arbitrary file input and extract all relevant subfiles and metadata for use in helping analysts determine the function and maliciousness of a file at a glance. This is an extension to the original code developed by Lockheed Martin.

Walkup, Gregory↗

Man‐in‐the‐middle attacks and defence in a power system cyber‐physical testbed

Abstract Man‐in‐The‐Middle (MiTM) attacks present numerous threats to a smart grid. In a MiTM attack, an intruder embeds itself within a conversation between two devices to either eavesdrop or impersonate one of the devices, making it appear to be a normal exchange of information. Thus, the intruder can perform false data injection (FDI) and false command injection (FCI) attacks that can compromise power system operations, such as state estimation, economic dispatch, and automatic generation control (AGC). Very few researchers have focused on MiTM methods that are difficult to detect within a smart grid. To address this, we are designing and implementing multi‐stage MiTM intrusions in an emulation‐based cyber‐physical power system testbed against a large‐scale synthetic grid model to demonstrate how such attacks can cause physical contingencies such as misguided operation and false measurements. MiTM intrusions create FCI, FDI, and replay attacks in this synthetic power grid. This work enables stakeholders to defend against these stealthy attacks, and we present detection mechanisms that are developed using multiple alerts from intrusion detection systems and network monitoring tools. Our contribution will enable other smart grid security researchers and industry to develop further detection mechanisms for inconspicuous MiTM attacks.

Wlazlo, Patrick↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Supporting Cyber Security of Power Distribution Systems by Detecting Differences Between Real-time Micro-Synchrophasor Measurements and Cyber-Reported SCADA (Final Report)

As modern power grids tend towards greater levels of automation and communication, the challenges of identifying and mitigating vulnerabilities to cyber-attacks are ones that are increasingly demanding attention. Today’s power system has evolved to form the foundational bedrock of modern society, and an attack on this infrastructure could prove disastrous. In this project we were tasked to investigate the use of distribution synchrophasors as an independent isolated sensor network with which we can corroborate, or flag potentially spoofed,Supervisory Control And Data Acquisition (SCADA) data. We adapted an approach to marry the underlying physical properties of power systems with the network communications used by power systems in order to offer insights unattainable by either data stream isolation. While the concept of intrusion detection systems (IDS) is well understood for monitoring network traffic and traditional IT computing systems, the approach discussed in this report is motivated by several key notions: first, current SCADA communications alone presents an incomplete view of the grid. Second, the power grid, and the equipment controlling it, is grounded by laws of physics. Given this, we leverage high-frequency physical grid measurements to understand the physical condition of the grid, and combine this with SCADA. While high-frequency physical grid measurements and SCADA communication over Internet Protocol (IP) networks are fundamentally disparate information sources, when collectively examined through appropriate lenses, they offer a much more nuanced depiction of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗