Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tumor Location, Interval Between Surgery and Radiotherapy, and Boost Technique Influence Local Control After Breast-Conserving Surgery and Radiation: Retrospective Analysis of Monoinstitutional Long-Term Results

Purpose: To obtain long-term data on local tumor control after treatment of invasive breast cancer by breast-conserving surgery and adjuvant radiotherapy (RT), in consideration of the interstitial high-dose-rate boost technique. Patients and Methods: A total of 263 women with 268 mammary carcinomas (International Union Against Cancer Stage I-IIB) who had undergone breast-conserving surgery and adjuvant RT between 1990 and 1994 were included. The potential risk factors for local recurrence-free survival were investigated. Results: During a median follow-up period of 94 months, 27 locoregional recurrences, 25 of which were in breast, were diagnosed. The cumulative rate of in-breast recurrence was 4.1% {+-} 1.4% at 5 years of follow-up and 9.9% {+-} 2.4% at 10 years. The multivariate analysis identified medial tumor location and delayed RT (defined as an interval of >2 months between surgery and the start of RT) as significant risk factors for in-breast recurrence in the overall study population. Medial tumor location vs. lateral/central location (hazard ratio, 2.48; 95% confidence interval, 1.06-5.84) resulted in a cumulative in-breast recurrence rate of 22.5% {+-} 8.3% vs. 6.9% {+-} 2.3% at 10 years. Delayed RT (hazard ratio, 2.84; 95% confidence interval, 1.13-7.13) resulted in a cumulative in-breast recurrence rate of 18.5% {+-} 6.2% vs. 6.8% {+-} 2.4% at 10 years. The multivariate analysis also showed that the risk of in-breast recurrence was lower after high-dose-rate boost therapy than after external beam boost therapy in patients with laterally/centrally located tumors (hazard ratio, 3.25; 95% confidence interval, 0.91-11.65). Conclusion: Tumor location, interval between surgery and RT, and boost technique might influence local control of breast cancer treated by breast-conserving surgery and RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interval Between Hysterectomy and Start of Radiation Treatment Is Predictive of Recurrence in Patients With Endometrial Carcinoma

Purpose: Adjuvant radiation therapy (RT) has been shown to improve local control in patients with endometrial carcinoma. We analyzed the impact of the time interval between hysterectomy and RT initiation in patients with endometrial carcinoma. Methods and Materials: In this institutional review board-approved study, we identified 308 patients with endometrial carcinoma who received adjuvant RT after hysterectomy. All patients had undergone hysterectomy, oophorectomy, and pelvic and para-aortic lymph node evaluation from 1988 to 2010. Patients' demographics, pathologic features, and treatments were compared. The time interval between hysterectomy and the start of RT was calculated. The effects of time interval on recurrence-free (RFS), disease-specific (DSS), and overall survival (OS) were calculated. Following univariate analysis, multivariate modeling was performed. Results: The median age and follow-up for the study cohort was 65 years and 72 months, respectively. Eighty-five percent of the patients had endometrioid carcinoma. RT was delivered with high-dose-rate brachytherapy alone (29%), pelvic RT alone (20%), or both (51%). Median time interval to start RT was 42 days (range, 21-130 days). A total of 269 patients (74%) started their RT <9 weeks after undergoing hysterectomy (group 1) and 26% started ≥9 weeks after surgery (group 2). There were a total of 43 recurrences. Tumor recurrence was significantly associated with treatment delay of ≥9 weeks, with 5-year RFS of 90% for group 1 compared to only 39% for group 2 (P<.001). On multivariate analysis, RT delay of ≥9 weeks (P<.001), presence of lymphovascular space involvement (P=.001), and higher International Federation of Gynecology and Obstetrics grade (P=.012) were independent predictors of recurrence. In addition, RT delay of ≥9 weeks was an independent significant predictor for worse DSS and OS (P=.001 and P=.01, respectively). Conclusions: Delay in administering adjuvant RT after hysterectomy was associated with worse survival endpoints. Our data suggest that shorter time interval between hysterectomy and start of RT may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time Interval From Breast-Conserving Surgery to Breast Irradiation in Early Stage Node-Negative Breast Cancer: 17-Year Follow-Up Results and Patterns of Recurrence

Purpose: A retrospectivechart review was conducted to determine whether the time interval from breast-conserving surgery to breast irradiation (surgery-radiation therapy interval) in early stage node-negative breast cancer had any detrimental effects on recurrence rates. Methods and Materials: There were 566 patients with T1 to T3, N0 breast cancer treated with breast-conserving surgery and breast irradiation and without adjuvant systemic treatment between 1985 and 1992. The surgery-to-radiation therapy intervals used for analysis were 0 to 8 weeks (201 patients), >8 to 12 weeks (233 patients), >12 to 16 weeks (91 patients), and >16 weeks (41 patients). Kaplan-Meier estimates of time to local recurrence, disease-free survival, distant disease-free survival, cause-specific survival, and overall survival rates were calculated. Results: Median follow-up was 17.4 years. Patients in all 4 time intervals were similar in terms of characteristics and pathologic features. There were no statistically significant differences among the 4 time groups in local recurrence (P=.67) or disease-free survival (P=.82). The local recurrence rates at 5, 10, and 15 years were 4.9%, 11.5%, and 15.0%, respectively. The distant disease relapse rates at 5, 10, and 15 years were 10.6%, 15.4%, and 18.5%, respectively. The disease-free failure rates at 5, 10, and 15 years were 20%, 32.3%, and 39.8%, respectively. Cause-specific survival rates at 5, 10, and 15 years were 92%, 84.6%, and 79.8%, respectively. The overall survival rates at 5, 10, and 15 years were 89.3%, 79.2%, and 66.9%, respectively. Conclusions: Surgery-radiation therapy intervals up to 16 weeks from breast-conserving surgery are not associated with any increased risk of recurrence in early stage node-negative breast cancer. There is a steady local recurrence rate of 1% per year with adjuvant radiation alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pathologic Response, When Increased by Longer Interval, Is a Marker but Not the Cause of Good Prognosis in Rectal Cancer: 17-year Follow-up of the Lyon R90-01 Randomized Trial

Purpose: The Lyon R90-01 randomized trial investigated whether the interval between preoperative radiation therapy and surgery influenced rectal cancer outcome. Long-term results are reported here after a median follow-up of 17 years. Methods and Materials: Between February 1991 and December 1995, 210 patients from 29 French centers were randomly assigned (ratio of 1:1) to groups that waited either 2 weeks (short interval [SI]) or 6 to 8 weeks (long interval [LI]) between neoadjuvant radiation therapy and surgery. The primary endpoint was sphincter-preserving surgery. Results: LI group showed a better pathologic response (complete response or few residual cells) after radiation therapy than the SI group (26% vs 10.3%, P=.015). A better pathologic response was associated in multivariate analysis with significant improvement of overall survival (pT: P=.0293 and pN: P=.0048) but it was irrespective of the interval duration. The median follow-up was 17.2 years. The 5-, 10-, 15-, and 17-year overall survival rates were, respectively, 66.8%, 48.7%, 40.0%, and 34.0% for the SI group and, respectively, 67.1%, 53.5%, 41.9%, and 34.0% for the LI group. There were no significant differences between groups in terms of survival (P=.7656) or local recurrence rates (SI: 14.4% vs LI: 12.1%, respectively; P=.6202). Of 24 local disease recurrences, 20 (83%) occurred during the first 2 postoperative years, and all but one (96%) occurred during the first 5 postoperative years. The rate of second new malignancies was 9.4% (19 patients). Conclusions: The radiation-induced sterilization rate of the preoperative cancer specimen was a marker of good prognosis. The interval duration (the treatment being the same) although it is modifying the sterilization rate has no impact on survival. Radiation therapy did not postpone local recurrence, because the rate of local relapse after 5 years was low. Radiation-induced cancers after radiation therapy were unusual and should not influence treatment decisions in adults.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An interval-parameter stochastic robust optimization model for supporting municipal solid waste management under uncertainty

A stochastic robust interval linear programming model (IPRO) was developed for supporting municipal solid waste management under uncertainty. The model improves upon the existing stochastic robust optimization (SRO) and interval linear programming (ILP) methods by allowing evaluations of trade-offs among expected costs, cost variability, and risk of violating relax constraints simultaneously, as well as reflections of complex uncertainties through both interval and stochastic theories. A long-term waste management problem was used to demonstrate the applicability of IPRO model. The results indicated that IPRO normally led to interval solutions, where waste-management alternatives could be generated by adjusting the decision-variable values within their intervals. The model could also help waste managers to identify desired policies that under various environmental, economic, system-feasibility and system-reliability constraints.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Oscillatory dynamics of an intravenous glucose tolerance test model with delay interval

We report that type 2 diabetes mellitus (T2DM) has become prevalent pandemic disease in view of the modern life style. Both diabetic population and health expenses grow rapidly according to American Diabetes Association. Detecting the potential onset of T2DM is an essential focal point in the research of diabetes mellitus. The intravenous glucose tolerance test (IVGTT) is an effective protocol to determine the insulin sensitivity, glucose effectiveness, and pancreatic β-cell functionality, through the analysis and parameter estimation of a proper differential equation model. Delay differential equations have been used to study the complex physiological phenomena including the glucose and insulin regulations. In this paper, we propose a novel approach to model the time delay in IVGTT modeling. This novel approach uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. Normally, larger time delay, either a discrete or a distributed delay, will destabilize the system. However, we find that time delay over a sub-interval might not. We present analytically some basic model properties, which are desirable biologically and mathematically. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Moreover, our numerical simulation results indicate that our model may remove the defect in well known Minimal Model, which often overestimates the glucose effectiveness index. Delay differential equations (DDEs) have been frequently used to study complex dynamics observed in nature. More recently, they are used to understand intriguing physiological phenomena such as those expressed by glucose and insulin interaction. We propose a simple set of delay differential equations to model an intravenous glucose tolerance test. This model uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Lastly and most importantly, our model may remove the defect in the well known Minimal Model (MM) which often overestimates the glucose effectiveness (GE) index.

59 BASIC BIOLOGICAL SCIENCES↗

Bath and Shower Effect in Spinal Cord: The Effect of Time Interval

Purpose: To evaluate the time dependency of the sensitizing effect of a large low-dose field on a small high-dose field in the rat cervical spinal cord. Methods and materials: Irradiation experiments with a relatively low dose to a large volume (bath, 2 cm, 4 Gy) were combined with high doses to a small volume (shower, 4.7 mm, 26-43 Gy) at intervals of 8 minutes and 3, 12, and 24 hours. Both a functional score defined as motor impairment and a histologic score characterized as white matter necrosis were used as end points. Results: Application of the 4-Gy bath dose resulted in a significant decrease in 50% isoeffective dose (ED{sub 50}) from 48.7 Gy (small field) to 40.8 Gy. If the interval was extended, the ED{sub 50} increased to 44.4 (3 hours) and 44.8 Gy (12 hours), whereas a 24-hour interval resulted in a significant increase to 51.9 Gy. If the histologic end point was considered, the ED{sub 50} for all dose-response curves decreased slightly with 0.2 to 2.6 Gy without significantly changing the kinetics. Conclusions: The bath effect as applied in the bath-and-shower experiment lasted for at least 12 hours and disappeared in the 24-hour interval. This time scale clearly deviates from the repair kinetics in spinal cord derived from low-dose-rate and fractionated irradiations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Dispatch Complaint and Critical Prehospital Time Intervals in Suspected Stroke 911 Activations in the National Emergency Medical Services Information System, 2012–2016

Emergency Medical Services can help improve stroke outcomes by recognizing stroke symptoms, establishing response priority for 911 calls, and minimizing prehospital delays. This study examines 911 stroke events and evaluates associations between events dispatched as stroke and critical EMS time intervals. Data from the National Emergency Medical Services Information System, 2012 to 2016, were analyzed. Activations from 911 calls with a primary or secondary provider impression of stroke were included for adult patients transported to a hospital destination. Three prehospital time intervals were evaluated: (1) response time (RT) ≤8 min, (2) on-scene time (OST) ≤15 min, and (3) transport time (TT) ≤12 min. Associations between stroke dispatch complaint and prehospital time intervals were assessed using multivariate regression to estimate adjusted risk ratios (ARR) and 95% confidence intervals (CIs). Approximately 37% of stroke dispatch complaints were identified by EMS as a suspected stroke. Compared to stroke events without a stroke dispatch complaint, median OST was shorter for events with a stroke dispatch (16 min vs. 14 min, respectively). In adjusted analyses, events dispatched as stroke were more likely to meet the EMS time benchmark for OST ≤15 min (OST, 1.20 [1.20–1.21]), but not RT or TT (RT, [1.00–1.01]; TT, 0.95 [0.94–0.95]). Furthermore, our results indicate that dispatcher recognition of stroke symptoms reduces the time spent on-scene by EMS personnel. These findings can inform future EMS stroke education and quality improvement efforts to emphasize dispatcher recognition of stroke signs and symptoms, as EMS dispatchers play a crucial role in optimizing the prehospital response.

59 BASIC BIOLOGICAL SCIENCES↗

Multiplicative scale uncertainties in the unified approach for constructing confidence intervals

We have investigated how uncertainties in the estimation of the detection efficiency affect the 90\% confidence intervals in the unified approach for constructing confidence intervals. The study has been conducted for experiments where the number of detected events is large and can be described by a Gaussian probability density function. We also assume the detection efficiency has a Gaussian probability density and study the range of the relative uncertainties $\sigma_\epsilon$ between 0 and 30\%. We find that the confidence intervals provide proper coverage and increase smoothly and continuously from the intervals that ignore scale uncertainties with a quadratic dependence on $\sigma_\epsilon$.

Smith, Elton↗

Analysis of Onset Mechanisms of a Sphingosine 1-Phosphate Receptor Modulator Fingolimod-Induced Atrioventricular Conduction Block and QT-Interval Prolongation

Fingolimod, a sphingosine 1-phosphate (S1P) receptor subtype 1, 3, 4 and 5 modulator, has been used for the treatment of patients with relapsing forms of multiple sclerosis, but atrioventricular conduction block and/or QT-interval prolongation have been reported in some patients after the first dose. In this study, we directly compared the electropharmacological profiles of fingolimod with those of siponimod, a modulator of sphingosine 1-phosphate receptor subtype 1 and 5, using in vivo guinea-pig model and in vitro human ether-a-go-go-related gene (hERG) assay to better understand the onset mechanisms of the clinically observed adverse events. Fingolimod (0.01 and 0.1 mg/kg) or siponimod (0.001 and 0.01 mg/kg) was intravenously infused over 10 min to the halothane-anaesthetized guinea pigs (n = 4), whereas the effects of fingolimod (1 μmol/L) and siponimod (1 μmol/L) on hERG current were examined (n = 3). The high doses of fingolimod and siponimod induced atrioventricular conduction block, whereas the low dose of siponimod prolonged PR interval, which was not observed by that of fingolimod. The high dose of fingolimod prolonged QT interval, which was not observed by either dose of siponimod. Meanwhile, fingolimod significantly inhibited hERG current, which was not observed by siponimod. These results suggest that S1P receptor subtype 1 in the heart could be one of the candidates for fingolimod- and siponimod-induced atrioventricular conduction block since S1P receptor subtype 5 is localized at the brain, and that direct I{sub Kr} inhibition may play a key role in fingolimod-induced QT-interval prolongation. - Highlights: • Fingolimod and siponimod are S1P{sub 1,3,4,5} and S1P{sub 1,5} receptor modulators, respectively. • Fingolimod and siponimod induced AV block in the halothane-anesthetized guinea pigs. • S1P{sub 1} in the hearts may be the target of fingolimod- and siponimod-induced AV block. • Fingolimod directly inhibited hERG current, which was not observed by siponimod. • I{sub Kr} inhibition may play a key role in the fingolimod-induced QT prolongation.

60 APPLIED LIFE SCIENCES↗

Clustering Interval Load with Weather to Create Scenarios of Behind-the-Meter Solar Penetration

Forecasting load at the feeder level has become increasingly challenging with the penetration of behind-the-meter solar, as this self-generation is only visible to the utility as aggregated net-load. This work proposes a methodology for creation of scenarios of solar penetration at the feeder level for use by forecasters to test the robustness of their algorithm to progressively higher penetrations of solar. The algorithm draws on publicly available observations of weather condition (e.g., rainy/cloudy/fair) for use as proxies to sky clearness. These observations are used to mask and weight the interval deviations of similar native usage profiles from which average interval usage is calculated and subsequently added to interval net generation to reconstruct interval total generation. This approach improves the estimate of annual energy generation by 23%; where the net generation signal currently reflects 52% of total annual gener- ation, now 75% is captured. This methodology for creation of forecast testing scenarios is data driven and extensible to service territories which lack information on irradiance measurements and geocoordinates.

solar, load↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Burst delay line for generating ultrashort pulse bursts with interval tunability from femtoseconds to nanoseconds.

Ultrashort burst laser pulses are important for applications in laser processing and spectroscopy. However, existing burst generators face limitations in pulse time interval tunability and coaxiality. Here, we present a burst pulse generator that delivers coaxial ultrashort pulses with tunable pulse time intervals using a single translation stage. The constructed system produced eight femtosecond pulses with uniform intervals tunable from 100 fs to 1.93 ns, equivalent to burst-internal repetition rates spanning 10 THz to 0.52 GHz. We further demonstrated interval-dependent plasma emission in air filamentation, providing a compact platform to study burst-laser-induced phenomena.

Shimada, Keitaro↗

Correction of confidence intervals in excess relative risk models using Monte Carlo dosimetry systems with shared errors

Introduction: Measurement errors are ubiquitous in epidemiological studies, especially for doses arising from environmental and occupational exposures, which are difficult to assess. Correction methods for independent measurement errors, have been comprehensively described elsewhere, including regression calibration, simulation extrapolation (SIMEX), etc. However, when exposure estimates are constructed using complicated physical and biological models, uncertainties in the dosimetry system can become very complex. In such systems, uncertainties in some parameters may affect a large group of study participants simultaneously, and hence are “shared” as opposed to independent dosimetric uncertainties. Representing the structure of the uncertainty in the dosimetry by providing multiple realizations of possible dose has been described for several studies. The goal of this paper is to implement, and explore the properties of, a generalized estimating equation-based approach to shared uncertainties based on principles described in an earlier paper. Methods: The effects of shared and unshared dosimetry error on parameter estimates and confidence intervals in a generalized excess relative risk model are examined. A post-hoc correction method is implemented that constructs corrected confidence intervals based on an underlying variance structure described in an earlier paper. In this correction method it is assumed that the estimated slope parameter in a linear excess relative risk model is distributed as a mixture of normal and lognormal components. A simulation study of the behavior of this correction was developed based on multiple realizations provided by the Monte Carlo dosimetry system used for the plutonium exposures in the Mayak Worker Cohort and a risk model with close similarity to that used in analyses of lung cancer data in that cohort. Results: In the simulation study we found that shared dose errors severely degraded the coverage probabilities of confidence limits for the slope parameter in the linear excess relative risk model relating uncertain exposure to lung cancer risk. Using our correction method to adjust the confidence intervals provided much improved coverage probabilities for this parameter. A smaller amount of degradation in confidence interval coverage for other parameters (e.g. those in the baseline and dose modification terms) was noted, and the proposed correction method also improved coverage for these parameters as well. Discussion: Compared to other recently described methods our proposed correction method relies on relatively familiar software to fit dose response models. The basic modeling philosophy described here first uses existing Poisson regression methods to estimate parameters in the excess relative risk model; in this first stage mean dose (computed from the multiple realizations) is used as the independent variable in the regression. Once the model is fit we then correct (widen) the standard errors for all parameters using the proposed correction method. The simulation studies indicate that the methods described here are an important contribution to the available tools for dealing with shared measurement errors in complex risk analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories

With an intense work ethic, and high levels of devotion to their craft, seismologists continue to battle the elements and wrestle with complex logistics in their efforts to field instrumentation over the entire globe. We are fortunate to see data volumes accelerating in size, and quality continuing to improve; for example, universal timing issues can now be considered rare. However, instrument response issues are still common, and can hinder research that seeks to understand amplitudes of seismic wavefields. We are interested in using the accumulations of seismic data to develop models that will predict high frequency (0.2-20 Hz, and higher) signal amplitudes for explosion monitoring purposes over broad areas, which requires large data sets and extensive quality control. To identify response and station health issues, we have collected noise time histories for global seismic data, focusing on measurements near (but not restricted to) midnight to eliminate diurnal variations, and have manually determined time intervals that appear inconsistent with background behavior. We assign descriptive labels, but do not attempt to diagnose causes. We use these intervals to discard data. To date, we have examined 39,260 channels from 11,105 stations, heavily weighted toward IRIS holdings, dates through 2017 (depending on station, roughly the date we started our manual review), bands between 1 and 8 Hz, finding 24,733 anomalous time intervals. The great majority (90%) of these intervals appear to be shifts of constant offset, often bounded by times of known instrument changes, likely the result of poor documentation of response parameters at one of many stages between the field and the plotter. We hope these results can be of use to our colleagues, and would encourage community efforts to diagnose anomalous behavior, and fix poor responses. We also hope these results will support automation efforts, including application of supervised learning techniques.

47 OTHER INSTRUMENTATION↗

Monitoring molecular interactions using photon arrival-time interval distribution analysis

A method for analyzing/monitoring the properties of species that are labeled with fluorophores. A detector is used to detect photons emitted from species that are labeled with one or more fluorophores and located in a confocal detection volume. The arrival time of each of the photons is determined. The interval of time between various photon pairs is then determined to provide photon pair intervals. The number of photons that have arrival times within the photon pair intervals is also determined. The photon pair intervals are then used in combination with the corresponding counts of intervening photons to analyze properties and interactions of the molecules including brightness, concentration, coincidence and transit time. The method can be used for analyzing single photon streams and multiple photon streams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical Stopping Power and Range Parameterization for Therapeutic Energy Intervals

The literature on stopping powers and ranges for proton and heavier ions is vast. It includes measurements, theory, evaluations and tabulations, and software programs and routines. Electronic stopping powers are typically calculated with either the Bethe-Bloch Equation or empirically derived functions, depending on the energy regime of the ion. Nuclear stopping powers are typically calculated using a theoretical approach. Ranges are commonly calculated numerically using path length integration, stopping power data and the continuous slowing down approximation. The Stopping and Ranges of Ions in Matter (SRIM) by Ziegler et al., which provides these and other capabilities, exemplifies the integration of highly-realistic theories, evaluated data, and radiation transport capabilities. In applications where speed and simplicity are paramount considerations, analytical calculations of range offer considerable advantages over numerical methods. Range has long been calculated analytically using a simple power law known as the range-energy relationship. This provides excellent accuracy over a surprisingly wide interval of ion species (e.g. protons, carbon), ion energies (e.g. 10-200 MeV/u), absorber compositions (e.g. plastic, water, metal), and thickness (e.g. 0.5-1 10 mm). The major limitation of formulas derived from a simple power law relation was their limited interval of applicability, 1.e., 10-200 MeV for protons in water. Thus, fora projectile in a stopping length target, such as a cancer patient, the simple power law model breaks down in the biologically important interval below 10 MeV. In current standard-of-care treatment planning, this is typically not a concern because the resulting range errors are less than 1 mm (and can be accounted for) and because biological effects are not calculated based on ion stopping power. However, there is considerable interest to perform multi-scale calculations of ion beams, e.g., at dimensions corresponding to cellular DNA, with ion energies below 10 MeV. Thus, there is an increasing need for new fast and simple formulae to calculate range and stopping power across a broader energy intervals of ion energy. It was not known if simple analytical equations would meet this need and, if so, the limits of their applicability. The aim of this work was to develop a simple, non-piecewise continuous model of total stopping power which could be analytically integrated to provide a simple formula for range. More specifically, we sought to develop a model to provide stopping powers with accuracy of better than 20% and range errors less than 1 mm for hydrogen, carbon, iron, and uranium projectile ions and target materials including water, carbon, aluminum, lead, copper, iron, gadolinium, and gold. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bootstrap-based confidence interval estimation for thermal security region of bulk power grid

Thermal security region (TSR) is a powerful tool for monitoring and controlling the thermal security of bulk power grid with high penetration of renewable energy. One of the major challenges of TSR in practical application is to obtain the exact analytical expression of the TSR boundary (TSRB) because TSRB is a nonlinear hypersurface described by an implicit function. For this reason, the TSRB is usually approximated by hyperplane instead of getting the exact analytical expression. Traditionally, the coefficients of the hyperplane are estimated with a set of original TSRB points using least square estimation (LSE). However, LSE is a point estimation method, which is incapable of evaluating the quality of the estimation. In addition, the accuracy and computational efficiency of the hyperplane approximation are influenced by the number of TSRB points significantly. Here, a bootstrap based confidence interval estimation is proposed to estimate not only the coefficients of TSRB approximation hyperplane, but also the standard deviations and confidence intervals of the coefficients for evaluating the quality and reliability of the approximation results. First, empirical distribution functions (EDFs) of the coefficients of TSRB approximation hyperplane are approximated from a set of original TSRB points by using residual resampling bootstrap method. Then, the EDFs of the coefficients are employed to estimate the coefficients of the approximation hyperplane. Meanwhile, the standard deviations and confidence intervals of the estimated coefficients of the hyperplanes are also calculated for evaluating the quality and reliability of the approximation. The proposed approach is tested on the China Southern Power Grid (CSG). Results of simulations validate the accuracy and efficiency of the proposed approach in approximating the TSRB.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗