Floating Photovoltaic System Cost Benchmark: Q1 2021 Installations on Artificial Water Bodies

In this report, we conduct a bottom-up analysis of the installed costs for FPV systems deployed on artificial water bodies under average site conditions (wind load of about 40 m/s, snow load of 20 psf, water depth of 50 m, water level variation of 10 m, and swell height of 1 m). We estimate an installed system cost premium of $\$0.26$/WDC (25%) for 10-MWDC fixed-tilt FPV systems, compared with ground-mounted, fixed-tilt PV installed over bare ground. Higher structural costs related to the floats and anchoring system are the largest contributors to this premium. Currently, site investigation costs are also higher for FPV because of the additional effort needed to plan and design these more complex installations. Our preliminary sensitivity analysis shows that the installed cost of FPV systems is most sensitive to float costs, wind and snow loading, and module efficiency. FPV deployment is in an early stage, and additional experience, best practice development, and new configurations and technologies could help reduce the costs of FPV systems over time.

14 SOLAR ENERGY↗

Empirical Estimation of the Energy Impacts of Projects Installed through Residential Property Assessed Clean Energy Financing Programs in California

We examine the energy use impacts of energy efficiency and solar PV projects financed by residential property assessed clean energy (R-PACE) programs in California. We leverage household-level interval meter data to apply normalized metered energy consumption (NMEC) methods at significant scale—more than 25,000 electric meters and more than 15,000 gas meters. We develop a comparison group to account for non-project-related changes in usage. The projects include homes that replaced existing HVAC equipment with higher-efficiency units and homes that installed central heating or air conditioning equipment for the first time. We have limited information on pre-project household equipment stock so we develop a method to infer new installations. We find that projects that installed energy efficiency technologies reduce electricity consumption by approximately 3% and gas consumption by approximately 3.5% on average. When we remove homes that installed new cooling and heating equipment for the first time, savings rise to approximately 5% for electricity and approximately 6% for gas. Given the California climate and the results of an existing study of similar California projects, these results are in line with expectations. Solar PV projects produce electricity that offsets approximately 69% of household electricity consumption on average. We estimate that California R-PACE projects installed through the end of 2019 produce annual reductions in grid-tied electricity consumption of 506 GWh (equivalent to the electricity consumption of approximately 74,000 California households) and gas consumption reductions of 2 million therms (equivalent to the gas consumption of approximately 4700 California households) in a typical weather year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vehicle for installing anchors in an underwater substrate

A method of installing one or more anchors in an underwater substrate in a body of water including installing an anchor into the underwater substrate by rotating an anchor installation vehicle about a central axis Y to drive the anchor coupled to the anchor installation vehicle into the underwater substrate. The anchor installation vehicle includes a vehicle frame having a top end and bottom end, a plurality of arms extending outward from the vehicle frame, one or more rotational thrusters disposed at distal ends of the respective arms, and an anchor system that holds the anchor extending from the bottom end of the vehicle frame with the anchor aligned with a central axis Y.

42 ENGINEERING↗

Installer Badges Toolkit and Visualization Resources

NREL staff (Jal Desai and Cory Chovanec) will introduce the U.S. Department of Energy Weatherization Assistance Program (DOE WAP) Installer Badges Toolkit. The presentation will cover topics such as how this toolkit can be customized and implemented in a program, the potential benefits of using the Badges, and lessons learned from other implementers. This session will also engage participants to share their experiences regarding their existing training and how they are bringing their workforce up to speed in their building envelope-related programs. The Installer Badges Toolkit consists of 25 Badges, each representing different energy efficiency tasks that an installer could perform on a home. Each Badge defines the desired outcome, criteria to verify the work, applicable material requirements, and references to DOE's Standard Work Specifications (SWS) or other relevant standards. Workers earn Badges by completing each task and receiving approval from a qualified supervisor. The Badges provide a consistent approach to training by ensuring that installers are learning the same skills nationwide. Organizations can also customize the Toolkit by choosing only those Badges that are relevant to their program. NREL staff will also showcase new visualization resources like the Single-family and manufactured home job aids and the Single-family 3D house tool.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Monitoring installation of partially occluded subassemblies in modular construction factories using BIM, ray tracing, and computer vision

Modular and offsite construction methods are being increasingly adopted due to the advantages they offer in terms of project completion time, quality, and energy-efficiency. Despite these advantages, the current state of monitoring systems in modular construction factories highly relies on labor-intensive, subjective, and error-prone observational methods. A large body of research has aimed to automate the monitoring process using an array of sensors, such as IMUs and RFIDs, during the past two decades. Recently, computer vision-based methods have gained increasing interest as a non-intrusive technology to monitor the process inside modular construction factories. However, partial occlusion challenges have impeded their practical application on a large scale. This challenge is specifically important for monitoring the installation of subassemblies since they can obstruct the view of the monitoring camera, especially those that enable long-term monitoring like closed-circuit television (CCTV) fixed-view surveillance cameras. Here, this paper aims to address this challenge by proposing a novel computer vision-based method to monitor the installation of new subassemblies inside modular factories in highly occluded scenes. The proposed methodology identifies the subassemblies in the CCTV video footage using computer vision, analyzes the occlusions using BIM and ray casting techniques, and estimates the progress of assembly by comparing the BIM model with the detected subassemblies in the video. The proposed methodology was successfully validated on surveillance videos captured from a volumetric modular construction factory in the U.S., achieving 93% accuracy in identifying the installation of subassemblies. The results from this research show that the integration of BIM and computer vision is a promising method for monitoring the installation processes inside modular factories under severe occlusion.

97 MATHEMATICS AND COMPUTING↗

Opportunities for installed combined heat and power (CHP) to increase grid flexibility in the U.S.

Increasing use of renewable energy requires sufficient grid flexibility to address uncertainty and variability in electricity generation. Previous studies suggest that combined heat and power (CHP) systems may support grid flexibility but they do not consider operating hours. In this paper, we used CHP operating data and determined annual and monthly availability of the installed CHP capacity from various sectors (e.g., utility, independent power producer, commercial, and industrial) in all seven U.S. independent system operators (ISOs) and regional transmission organizations (RTOs). Also, we estimated hourly CHP availability installed in five facility types (i.e., hospitals, universities, hotels, offices, and manufacturing) in the state of New York. The results show that regardless of ISO/RTO, sector, or season, more than 40% of the installed CHP capacity (0.7–8.7 GW) was not fully utilized in 2019; the results are similar for 2018. This available CHP capacity accounted for up to 9% of the ISO/RTO's peak electric demand, which may yield cost savings up to $16 billion by avoiding installation costs of new natural gas combustion or combined-cycle turbines. To exploit the available CHP capacity to enhance grid flexibility, we recommend different policy implications including flexible contract lengths between CHP owners and grid operators, improved market designs, and simplified interconnection standards.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The roles of learning mechanisms in services: Evidence from US residential solar installations

Non-hardware costs are majority of the cost of producing solar photovoltaic (PV) electricity. Here we use matched data on patents and over 125,000 residential PV installations to estimate the effects of three learning mechanisms in reducing PV costs: learning by doing, searching, and interacting. While previous work in this area has focused predominantly on learning by doing, we find that learning by searching and interacting are also significant mechanisms to facilitate non-hardware cost reductions. Including these two mechanisms reduces the effect of learning by doing in explaining non-hardware cost reductions by 43%. Our results suggest that prior work may overemphasize the role of learning by doing and the policies that help generate learning by doing. Analysis of the supplier-network between installers and their suppliers shows that concentrated supplier networks are associated with lower non-hardware costs, although there are key differences between installer-panel and installer-inverter manufacturer networks. An important implication is that policies for reducing non-hardware costs need to take a more complete view of how different learning mechanisms engender cost reductions. They should particularly consider the important role of learning in supplier networks in cost reductions—an effect that until now has largely been missing in analyses of solar non-hardware costs.

14 SOLAR ENERGY↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Full Scale 3D Computational Model of the Industrial -Scale Coal Fired Boiler Performance for Temperature Sensor Installation Guidance

Abstract Nearly 30% of the electricity is generated by using coal as the primary fuel in the US. One of the major concerns in coal-fired power plants is the failure of boiler tubes that leads to unscheduled maintenance and has a huge economical and societal impact. High temperature flue gas along with ash pass over the boiler tubes, which over time leads to tube failure. Therefore, developing temperature sensors for harsh environments and install them for temperature sensing and boiler tube lifetime prediction is an urgent need. On the side of sensor development, the location of the sensor installation is important for stable sensing performance and easy calibration. In this study, computational fluid dynamics and heat transfer modeling are adopted to establish a full-scale 3-dimensional model of a coal-fired boiler to investigate the flue gas temperature distribution within the boiler and identify the proper locations for sensor installation. We proposed three criteria to select the temperature sensor installation location: (1) select the boiler tube panel away from the sidewalls, (2) select the boiler tube section closer to the top wall of the boiler; and (3) select the boiler tube on the back of the boiler panel (not directly facing the flue gas flow). In these regions, the flue gas temperature is stable, providing an ideal environment for stable temperature sensing and calibration.

Gupta, Tanuj↗

Installation and imaging of thousands of minirhizotrons to phenotype root systems of field-grown plants

Roots are vital to plant performance because they acquire resources from the soil and provide anchorage. However, it remains difficult to assess root system size and distribution because roots are inaccessible in the soil. Existing methods to phenotype entire root systems range from slow, often destructive, methods applied to relatively small numbers of plants in the field to rapid methods that can be applied to large numbers of plants in controlled environment conditions. Much has been learned recently by extensive sampling of the root crown portion of field-grown plants. But, information on large-scale genetic and environmental variation in the size and distribution of root systems in the field remains a key knowledge gap. Minirhizotrons are the only established, non-destructive technology that can address this need in a standard field trial. Prior experiments have used only modest numbers of minirhizotrons, which has limited testing to small numbers of genotypes or environmental conditions. This study addressed the need for methods to install and collect images from thousands of minirhizotrons and thereby help break the phenotyping bottleneck in the field. Over three growing seasons, methods were developed and refined to install and collect images from up to 3038 minirhizotrons per experiment. Modifications were made to four tractors and hydraulic soil corers mounted to them. High quality installation was achieved at an average rate of up to 84.4 minirhizotron tubes per tractor per day. A set of four commercially available minirhizotron camera systems were each transported by wheelbarrow to allow collection of images of mature maize root systems at an average rate of up to 65.3 tubes per day per camera. This resulted in over 300,000 images being collected in as little as 11 days for a single experiment. The scale of minirhizotron installation was increased by two orders of magnitude by simultaneously using four tractor-mounted, hydraulic soil corers with modifications to ensure high quality, rapid operation. Image collection can be achieved at the corresponding scale using commercially available minirhizotron camera systems. Along with recent advances in image analysis, these advances will allow use of minirhizotrons at unprecedented scale to address key knowledge gaps regarding genetic and environmental effects on root system size and distribution in the field.

54 ENVIRONMENTAL SCIENCES↗

Optimizing Residential HVAC Systems: Evaluating How the Usage of Smart Diagnostic Tools for Quality Installation and Commissioning Impacts System Performance and HVAC Contractor Businesses

The adoption of digital quality installation and fault detection tools has the potential to transform the $14 billon residential heating, ventilating, and air conditioning (HVAC) service and installation industry. Increased market penetration can be accelerated by providing an increased understanding of the energy and economic value proposition of the usage of these tools. In tandem with energy and HVAC system performance impact research and analysis, the Southface Team investigated the economic business implications for HVAC service and installation contractors adopting the use of measureQuick (mQ), a smart diagnostic app that aids in quality installation and fault detection and works agnostically with Bluetooth-enabled HVAC technician tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of shading following installation of agrivoltaic systems on eco-physiological and biochemical attributes of “Howes” cranberry in Massachusetts

Agrivoltaic (AV) systems, which integrate solar energy generation with crop production on the same piece of land, offer a sustainable solution for optimizing land-use efficiency. However, the impact of shading induced by solar panels on crop growth, physiology, and metabolic activities of cranberry is not known. Understanding these interactions is essential for assessing the feasibility of AV systems in cranberry production. In this study we evaluated eco-physiological and biochemical crop responses on a commercial ‘Howes’ cranberry bog grown under an agrivoltaics system using different row spacings in the year immediately following installation. Following installation of fixed tilt solar panels at a height of 3.0 m above the plant canopy, four shading treatments were evaluated: an uncovered control area and row spacings of 9.0 m, 7.0 m, and 5.0 m, corresponding to 30%, 35%, and 37% shading respectively. The shading effect was also evaluated at three different fruit developmental stages (green, blush, and full-red stage). Using microclimate sensors installed in the treatment areas, key eco-physiological and biochemical parameters, including leaf gas exchange, chlorophyll, anthocyanin, and antioxidant content, electrolyte leakage, proline and trehalose accumulation, were assessed. While moderate shading (30% and 35%) alleviated environmental stress, as reflected by improved leaf water status and reduced electrolyte leakage, these same treatments suppressed key physiological and metabolic functions, including photosynthetic activity, carbon reserve accumulation, and the biosynthesis of stress-related osmolytes and antioxidant compounds. Under higher shading (37%), these reductions were even more pronounced, indicating a potential threshold beyond which the benefits of shading are outweighed by declines in assimilate production and secondary metabolism. These findings highlight a trade-off between the stress-mitigating benefits of shading and the alterations in key physiological and metabolic processes under agrivoltaic systems. Minimizing these trade-offs by optimizing row spacing in agrivoltaics systems is critical to maintain cranberry physiological status. Since commercial cranberry is grown as a continuous plant canopy (no interrow spaces for equipment travel), damage caused by the installation process likely impacted crop response evaluated in the first year; multi-year studies are needed to fully understand the dynamics of a dual-use system. Notably, this work provides the first direct measurements of proline, trehalose content, and electrolyte leakage in cranberry grown under AV conditions, offering new insight into their physiological adjustments to shading.

14 SOLAR ENERGY↗

Assessing the Impacts of Extreme Weather Events on Photovoltaic Installations Using Remote Sensing Imagery

In this study, we analyze poststorm satellite imagery to assess solar photovoltaic (PV) damage for over 11,300 systems following a catastrophic hailstorm in Austin, TX, in September 2023, which produced softball‐sized hail and for over 1500 systems across Puerto Rico and the US Virgin Islands after Hurricanes Irma and Maria in September 2017. Findings show that approximately 5.5% of identified PV sites were damaged in the hailstorm and approximately 17% of PV installations were damaged after the hurricanes. A weak correlation between hurricane wind gust speed and percent site damage was determined, with installation practices playing a heavy role in site resilience. Additionally, we show that newer module vintages are more susceptible to hail damage than older modules, possibly due to a convergence of larger size modules, decreased frame dimensions, and decreased front glass thickness but more research is needed. For hail sizes of 60 mm or greater, consistent hail damage is sustained by PV installations, regardless of system configuration.

14 SOLAR ENERGY↗

Installation protocol for charge transfer dissociation mass spectrometry on ion trapping mass spectrometers

Abstract Rationale Charge transfer dissociation (CTD) is a novel fragmentation technique that demonstrates enhanced structural characterization for a wide variety of molecules compared to standard fragmentation techniques like collision‐induced dissociation (CID). Alternative fragmentation techniques, such as electron transfer dissociation, electron capture dissociation, and ultraviolet photodissociation, also overcome many of the shortfalls of CID, but none of them are a silver bullet that can adequately characterize a wide variety of structures and charge states of target compounds. Given the diversity of structural classes and their occasional obstinance towards certain activation techniques, alternative fragmentation techniques are required that rely on novel or alternative modes of activation. Methods Herein, we present a step‐by‐step protocol for the installation of CTD on a quadrupole ion trap mass spectrometer and best practices for optimizing the signal‐to‐noise ratio and acquisition times for CTD mass spectra. Results In addition to two CTD installations in the Jackson laboratory, CTD has also been installed, and is currently in operation, on two 3D ion trap mass spectrometers in France: one in the laboratory of Dr. David Ropartz and Dr. Hélène Rogneaux at INRAE in Nantes, and the other in the laboratory of Dr. Jean‐Yves Salpin at Université d'Évry Val‐d'Essonne, part of the Paris‐Saclay University system. Conclusions Here, we provide a visual protocol to help others accomplish the instrument modification.

47 OTHER INSTRUMENTATION↗

Uplifting winds: The surprisingly positive community-wide impact of wind energy installations on property values

A primary concern of stakeholders when considering a new wind project is the potential negative effects wind turbines may have on home values. Yet, what has been surprisingly overlooked in the literature and general discourse around wind energy is that the well-researched positive economic development and fiscal and amenity benefits of wind energy (e.g., increased tax base, tax revenue, better public services and employment gains) might positively affect jurisdiction-wide housing values. With a focus on school districts in the United States, we compare home values in school districts with wind energy installations, before and after a wind energy installation becomes operational, to home values in other school districts located in the same county but without a wind energy installation to provide some of the first causal evidence on the relationship between wind energy projects and district-wide property values. We find that wind projects lead to economically meaningful increases in district-wide housing values of approximately 3 %, when those values are compared to similar homes located in school districts in same-county without wind energy. The effect is strongly correlated with wind project size. The mechanisms, our research suggests, are likely related to relatively large increases in school district per-pupil revenues and expenditures, which are also correlated with wind project size. We suggest other possible mechanisms for the increased values as well.

Attitudes↗

First STAX detector installation at the National Institute for Radioelements (IRE)

The Source Term Analysis of Xenon (STAX) project has been installing stack detectors at medical isotope production facilities to measure radioxenon emissions to investigate the effect of radioxenon releases on nuclear explosion monitoring. This paper outlines the installation of the first STAX detection system at the National Institute for Radioelements (IRE) in Fleurus, Belgium which has been operating for over three years and transferring collected data to the STAX repository. Information about the equipment installed, the data flow established, and calculations for determination of radioxenon releases from the facility are presented. Further. data quality was investigated to confirm values reported by STAX automated data processing and in a comparison of collected STAX data with data collected by IRE for regulatory reporting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. Furthermore, the electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank

This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current’s kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15*), 53.4 cm (21*), and 68.6 cm (27*) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65–80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.