Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

In situ quantification of fracture slip induced by hydraulic injections in a deep borehole: A comparison of two different borehole techniques

In situ measurements of fracture deformation during fluid injection are rare, yet essential for understanding the mechanical response of fractured rock. In this study, we evaluate the reliability of two methods by comparing their slip vector estimates: high-resolution borehole acoustic televiewer images captured before and after injection tests, and displacement data from a three-component borehole deformation probe recorded during the injections. Acoustic televiewer images capture only final in-plane displacement, whereas three-component borehole deformation measurements provide full 3D, transient fracture movement. Four injection tests in a fractured granitic rock mass along an inclined borehole at the Bedretto Underground Laboratory (Switzerland), beneath more than 1100 m of overburden, were analyzed. The two methods yielded consistent kinematics and comparable slip magnitudes, typically in the range of 0.2 – 0.6 mm. Angular differences between estimated slip directions ranged from 0.2° to 28°. For two test intervals with pre-existing fractures optimally oriented for slip, the measured slip vectors agreed with forward-modeled slip vectors based on the regional in situ stress field, supporting the Wallace–Bott hypothesis. Measurable shear displacement was identified in two test intervals containing fractures oriented nearly perpendicular to the least principal stress, including a newly formed hydraulic fracture. This demonstrates that even fractures unfavorably oriented for slip can undergo shear due to local stress perturbations around an inclined borehole.

Acoustic televiewer↗

Chemically Enabled CO 2 -Enhanced Oil Recovery in Multi-Porosity, Hydrothermally Altered Carbonates in the Southern Michigan Basin - Task 2 Topical Report

This attachment A is a detailed Topical Report for Task 2 (Advanced Field Characterization and Machine Learning Based Data Integration) under the project "Chemically Enabled CO 2 -Enhanced Oil Recovery in Multi-Porosity, Hydrothermally Altered Carbonates in the Southern Michigan Basin." The overall project activity and finding, including the field pilot testing of CO 2 injection are summarized in the companion Final Technical Report The Advanced Field Characterization and Machine Learning Based Data Integration task (Task 2) involved a systematic geologic characterization of the Trenton-Black River (TBR) play in the SMB which included the development of comprehensive datasets, advanced data analytics, risk assessment, and piggyback field characterization. These activities aimed to address the complex carbonate systems by evaluating the extent of fractures, dolomitization, facies, and reservoir properties with the primary objective of informing the static and dynamic modeling, field injection test, and providing input into the development strategy plan. The task was divided into four subtasks: • Subtask 2.1 – Data compilation, review, and analysis • Subtask 2.2 – Risk Assessment • Subtask 2.3 – Advanced Field Characterization • Subtask 2.4 – Integrated Physics-Based Machine Learning and Advanced Data Analytics

02 PETROLEUM↗

Performance and automatic calibration scheme of the waveform sampler in the ETROC2 ASIC chip

The waveform sampler in the CMS ETROC2 chip for LGAD gain aging monitoring is a 2.56-GS/s 12-bit 8x-Interleaved ADC that consists of a coarse SAR stage, and a fine stage. This architecture delivers high performance on a relatively modest 65 nm process, while requires finding up to 24 calibration constants through calibration. We developed an automatic calibration method using charge injection test data. After calibration, the baseline random error is reduced by a factor of 2.5–3 compared to the default calibration, and a 5% charge measurement precision is achieved in 15 fC charge injection tests.

Fu, Tao [Unlisted, US]↗

Closed cycle MHD power generation experiments using a helium-cesium working fluid in the NASA Lewis Facility

A MHD channel, which was previously operated for over 500 hours of thermal operation, ten thermal cycles, and 200 cesium injection tests, was removed from the facility and redesigned. The cross sectional dimensions of the channel were reduced to 5 by 16.5 cm to allow operation over a variety of conditions. The redesigned channel has been operated for well over 300 hours, 10 thermal cycles, and 150 cesium injection tests with no problems. Experiments have been run at temperatures of 1900-2100 K and Mach numbers from 0.3 to 0.55 in argon and 0.2 in helium. The best results to date have been obtained in the helium tests. Power outputs of 2.2 kw for tests with 28 electrodes and 2.1 kw for tests with 17 electrodes were realized. Power densities of 0.6 MW/cu m and Hall fields of about 1,100 V/m were obtained in the tests with 17 electrodes.

Sovie, R. J.↗

Ignition overpressure study from solid rocket motor firings

The objective was to investigate, through experimental means, the basic mechanisms influencing ignition overpressure and to determine ways to suppress ignition overpressure. Ignition overpressure was studied using solid rocket motors with geometry scaled at 1 percent of the Shuttle's Solid Rocket Boosters. Both water injection and aerosol foam were examined as a mean of reducing ignition overpressure. The results of the water injection tests indicate that a relatively small amount of water is sufficient to provide significant suppression. Of the flow rates tested, the lower water injection flow rates provided the best reduction of the ignition overpressure wave. Also, the test results show there is an optimum water flow rate range that provides the best suppression, and as this range is exceeded the effectiveness of water to reduce ignition overpressure is decreased. Aerosol foam provided very little reduction of ignition overpressure, but only small volumes of foam were used and further testing is necessary to determine its total effectiveness as a means of suppression.

Counter, Douglas D.↗

Go/No-Go Decision Point 1 Report

To satisfy the G/NG point 1 we have employed GEOS hydraulic fracturing module to simulate one of the Diagnostic Fracture Injection Tests conducted at well 58-32. The hydraulic fracturing solver relies on a finite element discretization of the mechanics fully coupled to a finite volume discretization of the fluid flow. Fractures are explicitly modeled as lower dimensional manifolds and discretized by 2D elements sitting at the boundary of cell elements. We have calibrated our model to reproduce the DFIT corresponding to Zone 2 Cycle 4 of the injection tests that took place at well 58-32.

15 GEOTHERMAL ENERGY↗

High Fidelity Modeling of WELL58-32 DFITS

Between 2017 and 2019, a series of injection tests were performed at pilot vertical well 58-32 at the Utah FORGE site. These injection activities were conducted in three distinct zones, isolated with packers and bridge plugs during the tests. Zone 1 consists of an open-hole section at the toe of the well, whereas Zones 2 and 3 are three-meter long cased and perforated sections. Several injection cycles were conducted in each zone. A detailed description of the geology of the FORGE site, of well 58-32 and of all injection cycles can be found in (Xing et al., 2020). The injection cycles included Diagnostic Fracture Injection Tests (DFITs). DFITs comprise two primary stages: an injection (pump-in) phase, where controlled fluid injection is employed to create a small hydraulic fracture in the surrounding rock, followed by a shut-in phase, where injection ceases, allowing observation of the formation’s pressure response. Utilizing methodologies such as the G-function analysis, DFITs provide valuable insights, including fracture closure pressure and the Instantaneous Shut-in Pressure (ISIP) and can be employed to estimate the minimum horizontal stress.

42 ENGINEERING↗

Coupling Factor Determination in the Control of Unintentionally Generated RF Fields

Radiated emissions and susceptibility requirements imposed in bands where intentional RF reception or transmission does not occur is problematical. It is often desired to compare radiated emissions with radiated susceptibility performance to assess system level compatibility. For reasons purely theoretical and because of practical measurement limitations, this not realistic. McCollum and Clark proposed a limit and test method that provided a direct comparison of radiated emissions and radiated susceptibility performance in those cases where only unintentional emissions and reception are of interest (non-tunable electronics). This test method, referred to as bulk current emissions (BCE) testing, and its associated limit is a complementary test method to bulk current injection testing and radiated susceptibility testing. Previous work utilized victim and culprit circuits with low common-mode loop impedance. Forward work identified in this publication was to determine how different loop impedance on culprit and victim circuits affected cable-to-cable coupling and the corresponding BCE test limit. Cable coupling factors for victim and culprit circuits with different loop impedance are investigated.

McCollum, Matthew B.↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Simulation of dilatancy-controlled gas migration processes in saturated bentonite using a coupled multiphase flow and elastoplastic H 2 M model

Dilatancy-controlled gas flow in preferential pathways plays a key role in the safety analysis of radioactive waste repositories. This is particularly the case for bentonite, an often-preferred barrier material. Gas flow in preferential pathways is characterized by localization and spontaneous behavior, which is challenging to simulate in numerical models due to strong hydro-mechanical coupling. To analyze a laboratory experiment in the framework of the DECOVALEX-2023 project, this study introduced a new approach of combining continuous modelling methods with spatial material properties derived from material heterogeneities and experimental observations. The proposed model utilized hydro-mechanical spatial distributions, namely Young's modulus and gas entry pressure, and elastoplasticity combined with a linear swelling model. A conceptual strain-dependent permeability approach simulated dilatancy-controlled gas flow based on hydro-mechanical coupling. To test the effectiveness of the presented approach, a gas injection test in a compacted, saturated bentonite sample was simulated using the open-source code OpenGeoSys 5.8 and compared with experimental observations. The presented methodology is capable of simulating localized gas flow in preferential pathways. The spatial distributions of Young's modulus and gas entry pressure affect the swelling pressure, relative permeability and, in combination with the strain-dependent permeability model, also the intrinsic permeability.

42 ENGINEERING↗

Advanced information processing system: Fault injection study and results

The objective of the AIPS program is to achieve a validated fault tolerant distributed computer system. The goals of the AIPS fault injection study were: (1) to present the fault injection study components addressing the AIPS validation objective; (2) to obtain feedback for fault removal from the design implementation; (3) to obtain statistical data regarding fault detection, isolation, and reconfiguration responses; and (4) to obtain data regarding the effects of faults on system performance. The parameters are described that must be varied to create a comprehensive set of fault injection tests, the subset of test cases selected, the test case measurements, and the test case execution. Both pin level hardware faults using a hardware fault injector and software injected memory mutations were used to test the system. An overview is provided of the hardware fault injector and the associated software used to carry out the experiments. Detailed specifications are given of fault and test results for the I/O Network and the AIPS Fault Tolerant Processor, respectively. The results are summarized and conclusions are given.

Burkhardt, Laura F.↗

Insights into the hydro-mechanical behavior of a decimeter-scale fracture using the mini-SIMFIP probe

ABSTRACT: Understanding hydro-mechanical couplings in fractured rocks is essential for predicting the rock mass response during high-pressure fluid injection, including the stimulation of enhanced geothermal systems. However, fluid-driven fracture dislocations are challenging to measure due to the need for local displacement data at high fluid pressures. In this study, fluid-driven displacement across a decimeter-scale laboratory fracture was investigated using the mini-SIMFIP (step rate injection method for fracture in-situ properties) probe, which is a smaller version of the SIMFIP tool (Guglielmi et al., 2014). The mini-SIMFIP probe is able to resolve the full 3D displacement vector of a fracture. The probe was installed in one of two boreholes across a decimeter-scale saw-cut granite fracture. Two pressure step injection tests were conducted under the same isotropic stress conditions. By varying injection between the boreholes, we estimated the aperture profile across the fracture. The results show a consistent pressure-dependent opening as long as steady-state flow was maintained. At a certain pressure step, steady-state conditions were no longer achievable and the fracture opened rapidly. The pressure-opening relationship diverged between the two tests and indicated a homogenization of the aperture profile and an increase in the non-linearity of the flow regime.

Osten, J↗

Characterization and controllability of radiated power via extrinsic impurity seeding in strongly negative triangularity plasmas in DIII-D

Experiments with extrinsic impurity seeding in strongly negative triangularity shapes in DIII-D achieved radiated power fractions (relative to input power) of up to ≈85% total radiation and ≈55% core radiation in steady-operating conditions. The relationship between core and total radiation was sensitive to impurity species and input power. Attempts to reach higher radiation levels via higher impurity flows resulted in radiative collapse disruptions. Nitrogen, neon, argon, and krypton were tested. Injection was by gas puffing, usually controlled by feeding back real-time estimates for core or total radiating fractions ($P_\textrm{rad} / P_\textrm{input}$). Argon and krypton were controlled by feeding back total radiating fraction, whereas neon was controlled by feeding back the core radiating fraction, due to the lower efficiency of neon as a divertor radiator. Nitrogen flows were pre-programmed. Reasonable total $P_\textrm{rad}$ control target following was achieved with argon or krypton. Control was more challenging with the neon/core radiation configuration, which was more prone to slow response and overshooting of the control target. Poor particle removal contributed to the control challenge: neon particle inventory within the last closed flux surface was roughly constant for up to 1 s (the longest duration tested) after neon injection was halted. However, separate experiments with laser-blow off of non-recycling impurities measured a short impurity confinement time, on the scale of the energy confinement time of ∼100 ms. Modeling with the Aurora impurity transport simulation matched experimental neon density profiles with full recycling (R = 1.0) and weak pumping but predicted rapid decreases in neon inventory if pumping were increased or recycling decreased. This indicates that changes outside the confined plasma (adding a well-placed pump) would improve controllability for all highly recycling species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flowback Test Analyses at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

Abstract In 2017 and 2019, injection testing was carried out in three zones in a vertical well in granite at the Frontier Observatory for Research in Geothermal Energy site near Milford, Utah, USA. In several injection cycles, flowback was implemented rather than shut-in. The goal was to explore an alternative to prolonged shut-in periods for inferring closure stress, formation compressibility, and formation permeability (permeability thickness product). The flowback procedures involved a cyclic flowback/shut-in, while pressure decreased. The flowback data are presented, and analyses are shown. The inferred closure stress(es) from flowback analyses are lower than for equivalent injection cycles that were strictly shut-in. Relatively high formation compressibility obtained from the flowback analyses indicates an extensive, fractured system. This study also includes numerical simulation of the flowback events. The numerical model shows that the rebound pressure is not necessarily the lower bound of the minimum principal stress. The signature of stiffness change can be identified as the process when the depletion mainly transitions from hydraulic fracture to natural fractures from numerical analysis. Overall, flowback potentially has advantages over shut-in because of the reduced time to closure.

15 GEOTHERMAL ENERGY↗

A micromechanical hydro-mechanical-damage coupled model for layered rocks considering multi-scale structures

An anisotropic Hydro-Mechanical-Damage coupled model was established in the framework of thermodynamics for saturated layered rocks, which contain arbitrarily-distributed cracks of smaller scales and orientated bedding planes of much larger scales. Here, the proposed model considers the anisotropic damage growth and frictional sliding of cracks and shear sliding and dilatancy of bedding planes, as well as the interaction between cracks and bedding planes. Numerical implementation of the nonlinear coupled model was developed based on TOUGHREACT, which is a well-established simulator for multiphase fluid flow and reactive transport analysis. The proposed model was first validated with laboratory water injection test results on rock blocks, and then used to study the effects of injection rates, in situ stresses and bedding planes on fluid injection processes at the field scale, demonstrating the importance to consider the variation of multi-scale structures for better understanding the coupled Hydro-Mechanical responses in layered rocks.

58 GEOSCIENCES↗

Multiple-orifice liquid injection into hypersonic air streams.

Review of oblique water and fluorocarbon injection test results obtained in experimental studies of the effects of multiple-orifice liquid injection into hypersonic air streams. The results include the finding that maximum lateral penetration from such injections increases linearly with the square root of the jet-to-freestream dynamic-pressure ratio and is proportional to an equivalent orifice diameter.

Weaver, W. L.↗

3D Simulations of gas injection on callovo-oxfordian claystone assuming spatial heterogeneity and anisotropy

A series of gas injection tests on Callovo-Oxfordian (COx) claystone from the Bure underground research laboratory (URL) in France were carried out at the British Geological Survey (BGS). The tests were performed using a triaxial apparatus specifically designed to capture small volumetric strains induced by the injected gas flow and consequent material dilatancy. The long-duration experiments were monitored throughout. Measurements also included pressure, stresses (axial and radial stresses prescribed for each test stage), rate of gas inflow, gas outflow volume as well as pore-pressures observed at various points of the sample. A coupled hydro-gas-mechanical 3D numerical model has been developed to simulate the tests. Initial permeability is assumed heterogeneous throughout the specimen and embedded fractures are incorporated in the formulation. Gas pressure-induced deformations during the test lead to variations of permeability due to changes in matrix porosity and, especially, fracture aperture as well as fracture orientation due to material anisotropy. A programme of sensitivity analyses involving the variation of different aspects and parameters of the model contributes to a better understanding of the phenomena and highlights its complexity. The model is able to reproduce the observed behaviour of the tests.

58 GEOSCIENCES↗

A Numerical Simulation of a Normal Sonic Jet into a Hypersonic Cross-Flow

This study involves numerical modeling of a normal sonic jet injection into a hypersonic cross-flow. The numerical code used for simulation is GASP (General Aerodynamic Simulation Program.) First the numerical predictions are compared with well established solutions for compressible laminar flow. Then comparisons are made with non-injection test case measurements of surface pressure distributions. Good agreement with the measurements is observed. Currently comparisons are underway with the injection case. All the experimental data were generated at the Southampton University Light Piston Isentropic Compression Tube.

Jeffries, Damon K.↗