Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS

The focus of this dissertation is the development of techniques with which to enhance the existing abilities of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique it has certain strengths and weaknesses. Attempts are made to improve upon those strengths and to overcome certain weaknesses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma density injection and flow during coaxial helicity injection in a tokamak

Whole device, resistive MHD simulations of spheromaks and tokamaks have used a large diffusion coefficient that maintains a nearly constant density throughout the device. In the present work, helicity and plasma are coinjected into a low-density plasma in a tokamak with a small diffusion coefficient. As in previous simulations [Hooper et al., Phys. Plasmas 20, 092510 (2013)], a flux bubble is formed, which expands to fill the tokamak volume. The injected plasma is non-uniform inside the bubble. The flow pattern is analyzed; when the simulation is not axisymmetric, an n = 1 mode on the surface of the bubble generates leakage of plasma into the low-density volume. Closed flux is generated following injection, as in experiments and previous simulations. The result provides a more detailed physics analysis of the injection, including density non-uniformities in the plasma that may affect its use as a startup plasma [Raman et al., Phys. Rev. Lett. 97, 175002 (2006)].

Hooper, E. B. (ORCID:0000000251197451)↗

Systems and methods for geothermal energy storage

A method and system may be used for storing energy in a geothermal system and recovering both the stored energy as well as thermal energy on demand. The geothermal system may include injection and production wells that are hydraulically coupled in a geothermal energy reservoir that behaves as a confined reservoir system with thermal energy transferring to fluid injected into the injection well and removed via the production well. Injection flow rate, injection pressure, production flow rate, production backpressure, or fluid residence time may be managed to control energy consumption or energy generation profiles of the geothermal system. During an energy storage mode, the injection flow rate exceeds the production flow rate thereby storing energy in the geothermal reservoir. During an energy recovery mode, production backpressure is reduced thereby releasing the stored energy and electricity is generated by removing the thermal energy from the fluid in a heat engine.

Norbeck, Jack↗

CFD Validation of Gas Injection in Flowing Mercury over Vertical Smooth and Grooved Wall

The Spallation Neutron Source (SNS) is an accelerator-based neutron source at Oak Ridge National Laboratory (ORNL).The nuclear spallation reaction occurs when a proton beam hits liquid mercury. This interaction causes thermal expansion of the liquid mercury which produces high pressure waves. When these pressure waves hit the target vessel wall, cavitation can occur and erode the wall. Research and development efforts at SNS include creation of a vertical protective gas layer between the flowing liquid mercury and target vessel wall to mitigate the cavitation damage erosion and extend the life time of the target. Since mercury is opaque, computational fluid dynamics (CFD) can be used as a diagnostic tool to see inside the liquid mercury and guide the experimental efforts. In this study, CFD simulations of three dimensional, unsteady, turbulent, two-phase flow of helium gas injection in flowing liquid mercury over smooth, vertically grooved and horizontally grooved walls are carried out with the commercially available CFD code Fluent-12 from ANSYS. The Volume of Fluid (VOF) model is used to track the helium-mercury interface. V-shaped vertical and horizontal grooves with 0.5 mm pitch and about 0.7 mm depth were machined in the transparent wall of acrylic test sections. Flow visualization data of helium gas coverage through transparent test sections is obtained with a high-speed camera at the ORNL target test facility (TTF). The helium gas mass flow rate is 8 mg/min and introduced through a 0.5 mm diameter port. The local mercury velocity is 0.9 m/s. In this paper, the helium gas flow rate and the local mercury velocity are kept constant for the three cases. Time integration of predicted helium gas volume fraction over time is done to evaluate the gas coverage and calculate the average thickness of the helium gas layer. The predicted time-integrated gas coverage over vertically grooved and horizontally grooved test sections is better than over a smooth wall. The simulations show that the helium gas is trapped inside the grooves. The predicted time-averaged gas coverage is in good qualitative agreement with the measured gas coverage.

43 PARTICLE ACCELERATORS↗

Hydraulic and Thermal Stimulation Program at Raft River Idaho, A DOE EGS

A Department of Energy Enhanced Geothermal System (EGS) stimulation program has injected over 254 million gallons of water into the well RRG-9 ST1 since the summer of 2013. Three major stimulations have been conducted during the program increasing injection flow rates from less than 20 gpm to 550 gpm. Geologic, water chemistry, microseismic activity, and borehole imaging data have been used to develop a conceptual model describing possible flow paths of this injected water. This model contains two major fracture zones one of which intersects the RRG-9 ST1 wellbore. Modified Hall and injectivity index plots constructed using injection flow rates, surface temperatures, and wellhead pressures show steady improvement in the injectivity of the well. Here, the injectivity index has risen from 0.15 gpm/psi to 2.0 gpm/ psi. A pressure falloff test conducted on April 28, 2015 indicates a reservoir permeability of 1,220 md and -5.38 skin factor. The well stimulation program was simulated numerically using an Idaho National Laboratory reservoir simulation code, FALCON. These simulations show a significant increase in the permeability of connecting fracture pathways after each stimulation event.

Enhanced geothermal system↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Fuel injector including tandem vanes for injecting alternate fuels in a gas turbine

A fuel injector for injecting fuels having a different energy density in a gas turbine is provided. A first fuel supply channel (18) and a second fuel supply channel (20) may be coaxially arranged in a fuel delivery structure (12). A first set of vanes 22 includes a radial passage (24) in fluid communication with the first channel (18) to receive a first fuel. Passage (24) branches into passages (26) each having an aperture (28) to inject the first fuel without jet in cross-flow injection. A second set of vanes (32) includes a radial passage (34) in fluid communication with the second channel (20) to receive a second fuel. Passage (34) branches into passages (36) each having an aperture (38) arranged to inject the second fuel also without jet in cross-flow injection. This arrangement may be effective to reduce flashback that otherwise may be encountered in fuels having a relatively high flame speed.

Laster, Walter Ray↗

THREE-DIMENSIONAL MAGNETOHYDRODYNAMIC MODELING OF PROPAGATING DISTURBANCES IN FAN-LIKE CORONAL LOOPS

Quasi-periodic propagating intensity disturbances (PDs) have been observed in large coronal loops in EUV images over a decade, and are widely accepted to be slow magnetosonic waves. However, spectroscopic observations from Hinode/EIS revealed their association with persistent coronal upflows, making this interpretation debatable. Motivated by the scenario that the coronal upflows could be the cumulative result of numerous individual flow pulses generated by sporadic heating events (nanoflares) at the loop base, we construct a velocity driver with repetitive tiny pulses, whose energy frequency distribution follows the flare power-law scaling. We then perform three-dimensional MHD modeling of an idealized bipolar active region by applying this broadband velocity driver at the footpoints of large coronal loops which appear open in the computational domain. Our model successfully reproduces the PDs with similar features as the observed, and shows that any upflow pulses inevitably excite slow magnetosonic wave disturbances propagating along the loop. We find that the generated PDs are dominated by the wave signature as their propagation speeds are consistent with the wave speed in the presence of flows, and the injected flows rapidly decelerate with height. Our simulation results suggest that the observed PDs and associated persistent upflows may be produced by small-scale impulsive heating events (nanoflares) at the loop base in the corona, and that the flows and waves may both contribute to the PDs at lower heights.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

Laser Ablation↗

Observations of phase changes in monoolein during high viscous injection

Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effect of foam quality, particle concentration and flow rate on nanoparticle-stabilized CO 2 mobility control foams

CO 2 foam is regarded as a promising technology and widely used in the oil and gas industry, not only to improve oil production, but also to mitigate carbon emissions through their capture. This paper describes a series of nanoparticle-stabilized CO 2 foam generation and foam flow experiments under reservoir conditions. Stable CO 2 foam was generated when CO 2 and a nanosilica dispersion flowed through the core sample under 1500 psi and 25 °C. The foam changed from a fine-texture foam to a coarse foam as the foam quality increased from 20% to 95%. Foam mobility increased slightly with the increasing foam quality from 20% to 80% and then rapidly from 80% to 95%. A stable CO 2 foam was generated as the nanosilica concentration increased to 2500 ppm. Foam mobility and resistance factor increased with the increasing nanosilica concentration. As the injection flow rate increased to 60 ml h -1 , stable and fine-texture CO 2 foam was obtained. Foam mobility was observed to remain almost constant as the injection flow rate increased from 60 ml h -1 to 150 ml h -1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time Intrusion Detection for High-bandwidth Research Networks using Unsupervised Deep Learning

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks across distributed collaboration sites for processing, storage, and analysis. Like general purpose networks, research networks experience attacks. However, monitoring traffic in such high-bandwidth network environments is challenging with conventional deep packet inspection (DPI)- based network intrusion detection systems (NIDS). Recently, machine learning (ML) algorithms have shown potential in detecting anomalous patterns with better generalizability and faster speed. Compared to the general purpose networks, traffic movement in research network is less volatile and more likely to benefit from the ML-based anomaly analysis. We present ThunderSecure, an efficient AI-powered system for detecting anomalies in 100G research networks. ThunderSecure implements a high-throughput packet processing infrastructure using multi-cores and GPUs. It takes time-series statistics from a variety of network measurements and uses 2D Convolutional Neural Network (CNN) to explore both spatial and temporal dependencies in network data stream. Patterns of science data traffic are learned with a one-class neural network, which blends an Adversarial Autoencoder (AAE) with Gaussian mixture density estimation. Testing traffic flows exhibiting significant deviations from the learned baseline of normality are marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets recorded from a 100G research network at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. To the best of our knowledge, this is the first ML work in the area of network anomaly detection that has been validated on such extreme scale datasets. Results show that ThunderSecure can recognize science data traffic that are captured long after the training and make nearly certain detection on those with anomalous flows injected, even in the case when the anomaly-to-normal mixing ratio is 0.1%.

Gong, Qian↗

Operator Action Time Evaluation of Emergency Water Injection Strategy for Extreme SGTR Accidents

In terms of severe accidents caused by earthquakes or tsunamis that are beyond expectation, a special safety inspection for operating plants, following the Fukushima accident, has been conducted by the government of Korea to verify that nation's nuclear power plants have been adequately designed to respond to extreme accidents. The inspection results show that Korean nuclear power plants in operation have no imminent risk for an expected maximum potential earthquake or coastal flooding based on the up-to-date investigation. However, there is a need to implement long- and short-term safety improvements in order to secure the level of safety for natural beyond-design-basis events. One of the measures to increase the mitigation capability during extreme accidents is installing the injection flow paths to provide emergency cooling water of extemal sources using fire engines to the steam generators (SGs) or reactor cooling system (RCS). An emergency cooling water system consists of a fixed pipe connected from the RCS or SGs to the outside of the containment. A standby valve is installed on the pipe. Following the occurrence of an extreme accident, movable equipment (for example, a fire truck hose) can be connected to the pipe hole at the opening of the isolation valve. The emergency cooling water injection strategy was not taken into account for the steam generator tube rupture (SGTR) accident management strategy of the OPR-1000. Therefore, it is necessary to develop some guidelines or strategies to cope with an extreme SGTR scenarios using the newly installed injection flow paths and fire engines. As long as the fission products released from the core during severe accidents are kept inside the containment, there may be several ways to reduce the radionuclide release into the environment, for example, by using plant safety features. The containment bypass sequences, however, allow the fission products to be released into the environment or directly to the auxiliary building. The SGTR accidents, which are one of the containment bypass sequences, have shown during various probabilistic safety assessments (PSAs) to be contributors to plant risk, mainly because of their potential for causing a release outside containment. This paper is intended to be an investigation of the characteristics of accident progressions and assessments for the mitigative effectiveness of the external cooling water injection strategies during extreme SGTR accidents in a typical OPR-1000 plant. Analyses were performed using a MAAP computer code version 5.03. The MAAP code is a system-level computer code capable of conducting integral analyses of potential severe accident progressions in nuclear power plants, whose main purpose is to support a level 2 PSA or severe accident management strategy developments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Two-Phase Terry Turbine Nozzle Models for RCIC Off-Design Operation Conditions

This report presents the effort to extend the single-phase analytical Terry turbine model to cover two-phase off-design conditions. The work includes: (1) adding well-established two-phase choking models – the Isentropic Homogenous Equilibrium Model (IHEM) and Moody’s model, and (2) theoretical development and implementation of a two-phase nozzle expansion model. The two choking models provide bounding cases for the two-phase choking mass flow rate. The new two-phase Terry turbine model uses the choking models to calculate the mass flow rate, the critical pressure at the nozzle throat, and steam quality. In the divergent stage, we only consider the vapor phase with a similar model for the single-phase case by assuming that the liquid phase would slip along the wall with a much slower speed and will not contribute the impulse on the rotor. We also modify the stagnation conditions according to two-phase choking conditions at the throat and the cross-section areas for steam flow at the nozzle throat and at the nozzle exit. The new two-phase Terry turbine model was benchmarked with the same steam nozzle test as for the single-phase model. Better agreement with the experimental data is observed than from the single-phase model. We also repeated the Terry turbine nozzle benchmark work against the Sandia CFD simulation results with the two-phase model for the pure steam inlet nozzle case. The RCIC start-up tests were simulated and compared with the single-phase model. Similar results are obtained. Finally, we designed a new RCIC system test case to simulate the self-regulated Terry turbine behavior observed in Fukushima accidents. In this test, a period inlet condition for the steam quality varying from 1 to 0 is applied. For the high quality inlet period, the RCIC system behaves just like the normal operation condition with a high pump injection flow rate and a nominal steam release rate through the turbine, with the net addition of water to the primary system; for the low quality inlet period, the RCIC turbine shaft work dramatically decreases and results in a much reduced pump injection flow rate, and the mixture flow rate through the turbine increases due to the high liquid phase flow rate. The net effect for this period is net removal of coolant from the primary loop. With the periodic addition and removal of coolant to the primary loop, the self-regulation mode of the RCIC system can be maintained for a quite long time. Both the IHEM and Moody’s models generate similar phenomena; however noticeable differences can be observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Overview of lithium injection and flowing liquid lithium results from the US–China collaboration on EAST

A multi-institutional team consisting of national labs and universities has been conducting research to understand and control the plasma-material interface (PMI) to improve long pulse discharge control and performance in the EAST device in Hefei, China. One particular focus of the group has been to evaluate the performance of different plasma-facing component (PFC) technologies and materials, particularly lithium. Flowing liquid lithium PFC technologies are currently into their third generation of development and deployment in EAST, demonstrating recycling control and mitigation of edge-localized modes (ELMs). A lithium powder dropper has also been used to control ELMs while a lithium granule injector has demonstrated ELM triggering and pacing. To support this work, the facilities at the Center for Plasma Material Interactions such as HIDRA are being commissioned and utilized to develop/test the technologies before deployment on EAST. This paper will present a summary of the collaborative lithium PMI program on EAST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of Different Vein Catheter Sizes for Mechanical Power Injection in CT: In Vitro Evaluation with Use of a Circulation Phantom

The purpose of this study was to evaluate the influence of different peripheral vein catheter sizes on the injection pressure, flow rate, injection duration, and intravascular contrast enhancement. A flow phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used. High-iodine-concentration contrast medium (370 mg iodine/ml; Ultravist 370) was administered in the venous compartment through peripheral vein catheters of different sizes (14, 16, 18, 20, 22, and 24 G) using a double-head power injector with a pressure limit of 325 psi. The flow rate was set to 5 ml/s, with a total iodine load of 36 g for all protocols. Serial CT scans at the level of the pulmonary artery and the ascending and the descending aorta replica were obtained. The true injection flow rate, injection pressure, injection duration, true contrast material volume, and pressure in the phantom during and after injection were continuously monitored. Time enhancement curves were computed and both pulmonary and aortic peak time and peak enhancement were determined. Using peripheral vein catheters with sizes of 14-20 G, flow rates of approximately 5 ml/s were obtained. During injection through a 22-G catheter the pressure limit was reached and the flow rate was decreased, with a consecutive decreased pulmonary and aortic contrast enhancement compared to the 14- to 20-G catheters. Injection through a 24-G peripheral vein catheter was not possible because of disconnection of the canula due to the high flow rate and pressure. In summary, intravenous catheters with sizes of 14-20 G are suitable for CT angiography using an injection protocol with a high flow rate and a high-iodine-concentration contrast medium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗