Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

30 DIRECT ENERGY CONVERSION↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

Building America↗

Simulation-based assessment of ASHRAE Guideline 36, considering energy performance, indoor air quality, and control stability

This study assesses American Society of Heating, Refrigerating and Air-Conditioning Engineers Guideline 36 (G36) with a typical medium office building. Specifically, this study employed a Modelica model of a variable air volume (VAV) system that serves this building, which includes components for representing indoor virus transmission and filtration. It then implemented the G36 control sequences for both water-side and air-side equipment in Python. After that, this study conducted the assessment by co-simulating G36 and the Modelica model using the Building Operations Testing Framework. Unlike existing works, this work has three unique features: (1) It considers the interactions between control sequences for water-side and air-side equipment of the studied VAV system. (2) It assesses the performance of G36 from the perspective of IAQ. (3) It examines the short-term behaviors of the studied building under G36 to understand the control stability. This assessment confirms significant energy savings from G36, largely because of the interaction between supply air temperature and hot water controls. It also reveals a trade-off between the ability to slow the spread of virus and the energy performance via demand controlled ventilation. Lastly, it emphasizes the necessity of tuning local feedback control when implementing G36.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of low-cost indoor air quality monitors for PM 2.5 and PM 10 from residential sources

Advances in particle sensor design and manufacturing have enabled the development of low-cost air quality monitors (LCMs). Here, the sensors use light scattering to estimate mass concentration and thus require evaluation for aerosols of varied composition and size distribution. We tested the performance of six LCMs designed for home use and having a retail price under US$300 in October 2018. We assessed their performance by comparing their output to reference PM 2.5 and PM 10 measurements from 21 common residential sources and from infiltrated outdoor PM 2.5 . Reference data were obtained by using gravimetric measurements to adjust time-resolved output from an aerosol spectrometer with both electrical mobility and optical particle sensors. Compared by linear regression to reference measurements, LCMs had negative intercepts and slopes of 1–2 for infiltrated outdoor PM 2.5 . Semi-quantitative responses (~50–200% of actual PM 2.5 ) were obtained for varied aerosols including minerals (ultrasonic humidifier, vacuuming, test dust); combustion products (incense, mosquito coil, extinguished candles); microwave popcorn; and cooking involving frying or grilling. LCMs had low or no response to sources for which all mass was in particles smaller than 0.25 μm, including steady candle flames and cooking without frying or grilling. PM 10 data from LCMs was more variable than PM 2.5 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California

This work presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ), formaldehyde and carbon dioxide (CO 2 ) and time-integrated formaldehyde, NO 2 and nitrogen oxides (NO X ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM 2.5 , formaldehyde, NO 2 , and CO 2 were 7.7 µg/m 3 , 14.1 ppb, 18.8 ppb, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM 2.5 above the California annual outdoor standard of 12 µg/m 3 and also discrete days above the World Health Organization 24-h guideline of 25 µg/m 3 . Two apartments had weekly NO 2 above the California annual outdoor standard of 30 ppb.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Healthy Indoor Air Quality: A Guide to Understanding Pollutants in Extreme Cold Climates

Internal air quality management through commonly supported recommendations in extreme cold weather climates is complicated by cold air infiltration. Air filtration and IAQ monitoring, through central and stand-alone systems can improve internal air quality to the benefit of occupant health and safety. This fact sheet includes reference information for pollutants, sources, health effects, and mitigation strategies.

cold climate↗

Advances in Desiccant Wheels for Dehumidification, VOC Mitigation, and CO 2 Removal for Energy-Efficient IAQ Management

Humidity control is pivotal to maintain occupant thermal comfort and suppress mold growth in indoor environments. Furthermore, poor indoor air quality (IAQ) due to the presence of volatile organic compounds (VOCs) and high concentrations (>1,000 ppm) of CO 2 can cause health issues and negatively affect cognitive performance. Therefore, providing high-quality indoor air has gained significant attention over the past decade. Conventional cooling coil and filter-based HVAC systems have limited capability to meet the augmented demand for occupant thermal comfort and high indoor air quality. Moreover, modern buildings are increasingly airtight to save energy, and increasing ventilation to mitigate VOC and CO 2 concentration is discouraged. Separate sensible and latent cooling technology using a rotary desiccant wheel presents a promising solution in this respect. Because of the development of desiccant materials with high water vapor, VOC, and CO 2 uptake, desiccant wheels can be used as an integrated technology option for IAQ management. Here, to promote desiccant wheel use for energy-efficient management of IAQ in buildings, this article reviews recent advancements in using desiccant wheels for dehumidification, VOC mitigation, and CO 2 capture from outdoor air. Finally, the article presents the authors’ perspective by summarizing the key research gaps in the field and discussing the future direction of research to address these gaps from two different aspects, namely, suitable adsorbent material development and desiccant wheel design.

CO2 capture↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗