Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Blockchain based Communication Architectures with Applications to Private Security Networks

Existing communication protocols in high consequence security networks are highly centralized. While this naively makes the controls easier to physically secure, external actors require fewer resources to disrupt the system because there are fewer points in the system can be destroyed or interrupted without the entire system failing. We present a solution to this problem using a proof-of-work-based blockchain implementation built on MultiChain. We construct a test-bed network containing two types of data input: visual imagers and microwave sensor information. These data types are ubiquitous in perimeter intrusion detection security systems and allow a realistic representation of a real-world network architecture. The cameras in this system use an object detection algorithm to nd important targets in the scene. The raw data from the camera and the outputs from the detection algorithm are then placed in a transaction on the distributed ledger. Similarly, microwave data is used to detect relevant events and are placed in a transaction. These transactions are then bundled into blocks and broadcast to the rest of the network using the Bitcoin-based MultiChain protocol. We develop five tests to examine the security metrics of our network. We performed the five security metric test using different sized networks from 7 to 39 nodes to determine how the metrics scale with respect to size. We nd that when compared to a centralized architecture our implementation provides a resiliency increase that is expected from a blockchain-based protocol without slowing the system so much that a human operator would notice. Furthermore, our approach is able to detect tampering in real time. Based on these results, we theorize that security networks in general could use a blockchain-based approach in a meaningful way.

97 MATHEMATICS AND COMPUTING↗

Development and Standup Testing of a System to Observe Fission Gas Release During Transient Heating of Nuclear Fuel Element Segments

As part of an effort to increase the burnup of nuclear fuels used in Light Water Reactors, the mechanisms and timing of fission gas release during high temperature transients must be studied. In this work, a system was built to observe fission gas release of fuel element sections under evacuated conditions, at temperatures up to 800 °C. System capabilities and limitations are overviewed in this report. The system was further tested with a hydrogen-infused titanium foils and gas release was observed in agreement with literature observations. Pressure was monitored with two sensors, and temperature was monitored using a thermocouple and a pyrometer with continuous visual imaging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Requirements for Soldering Fluxes Research using the B-53 Test Board

IPC J-STD-004B standard prescribes general requirements for the classification and testing of soldering flux for high qualify interconnections. This standard defines the classification of soldering materials through specifications of test methods and inspection criteria. The materials include liquid flux, paste flux, solderpaste flux, solder preform flux, and flux-cored solder. This research will use the proposed IPC-53 Surface Insulation Resistance (SIR) test patterns by means of an open comb (2D) and closed comb (3D to simulate a component over the comb pattern). The 2D open comb has uniformity of conductor spacing, sheet resistance, and flux outgassing. The 3D-closed comb simulates the effect of leadless or bottom-terminated components, which have non-uniform sheet resistance and flux outgassing. The response variables will include SIR testing and visual imaging. The objective is to investigate IPC test method improvements for characterizing soldering fluxes when using leadless components with narrow pad-to-pad spacing.

Diamond, Louis↗

A VR-based volumetric medical image segmentation and visualization system with natural human interaction

Volume rendering produces informative two-dimensional (2D) images from a 3-dimensional (3D) volume. It highlights the region of interest and facilitates a good comprehension of the entire data set. However, volume rendering faces a few challenges. First, a high-dimensional transfer function is usually required to differentiate the target from its neighboring objects with subtle variance. Unfortunately, designing such a transfer function is a strenuously trial-and-error process. Second, manipulating/visualizing a 3D volume with a traditional 2D input/output device suffers dimensional limitations. To address all the challenges, we design NUI-VR 2 , a natural user interface-enabled volume rendering system in the virtual reality space. NUI-VR 2 marries volume rendering and interactive image segmentation. It transforms the original volume into a probability map with image segmentation. A simple linear transfer function will highlight the target well in the probability map. More importantly, we set the entire image segmentation and volume rendering pipeline in an immersive virtual reality environment with a natural user interface. NUI-VR 2 eliminates the dimensional limitations in manipulating and perceiving 3D volumes and dramatically improves the user experience.

42 ENGINEERING↗

Interactive Visual Study of Multiple Attributes Learning Model of X-Ray Scattering Images

Existing interactive visualization tools for deep learning are mostly applied to the training, debugging, and refinement of neural network models working on natural images. However, visual analytics tools are lacking for the specific application of x-ray image classification with multiple structural attributes. In this paper, we present an interactive system for domain scientists to visually study the multiple attributes learning models applied to x-ray scattering images. It allows domain scientists to interactively explore this important type of scientific images in embedded spaces that are defined on the model prediction output, the actual labels, and the discovered feature space of neural networks. Users are allowed to flexibly select instance images, their clusters, and compare them regarding the specified visual representation of attributes. The exploration is guided by the manifestation of model performance related to mutual relationships among attributes, which often affect the learning accuracy and effectiveness. The system thus supports domain scientists to improve the training dataset and model, find questionable attributes labels, and identify outlier images or spurious data clusters. Case studies and scientists feedback demonstrate its functionalities and usefulness.

97 MATHEMATICS AND COMPUTING↗

In situ multimodal imaging for nanoscale visualization of tribofilm formation

A third of the energy from fuel combustion in passenger car gasoline engines is lost due to friction. Carefully designed engine lubricants can recover some of these losses by reducing friction and wear by forming a nanometer-scale chemico-physico tribofilm between surfaces. Accordingly, attention has focused on developing oil formulations that form low-friction tribofilms. However, analyses of resultant tribofilms are typically conducted after tribo-tests with conventional characterization tools and do not offer insights into tribofilm formation and evolution, precluding information critical to tuning tribofilm properties. In this work, we developed a unique multimodal methodology based on Atomic Force Microscopy (AFM) with local probe heating for in situ tribological studies that activates friction modifiers and simultaneously captures the evolution of friction and surface roughness, with nanometer resolution. As a platform to demonstrate the ability of this methodology to visualize dynamics of tribofilm formation in situ, we apply it to molybdenum-based friction modifiers to distinguish key factors in their functionality and correlate nanoscale AFM and Friction Force Microscopy data to bench tribo-tests used in the industry. To decode the formation mechanisms observed in situ and underlying chemistry of tribofilms, we performed ab initio Molecular Dynamics (AIMD) simulations at comparable conditions. AIMD simulations confirmed both nanoscale and bench tribo-test results and showed deviations in molecular organization in tribofilms that are formed from different molybdenum-based friction modifiers that corroborates with surface functionality. With this innovative methodology, we demonstrate proof-of-principle in situ formation of molybdenum-based tribofilms directly on steel surfaces that could be applied generally to studying tribofilm formation.

36 MATERIALS SCIENCE↗

Probing three-dimensional mesoscopic interfacial structures in a single view using multibeam X-ray coherent surface scattering and holography imaging

Abstract Visualizing surface-supported and buried planar mesoscale structures, such as nanoelectronics, ultrathin-film quantum dots, photovoltaics, and heterogeneous catalysts, often requires high-resolution X-ray imaging and scattering. Here, we discovered that multibeam scattering in grazing-incident reflection geometry is sensitive to three-dimensional (3D) structures in a single view, which is difficult in conventional scattering or imaging approaches. We developed a 3D finite-element-based multibeam-scattering analysis to decode the heterogeneous electric-field distribution and to faithfully reproduce the complex scattering and surface features. This approach further leads to the demonstration of hard-X-ray Lloyd’s mirror interference of scattering waves, resembling dark-field, high-contrast surface holography under the grazing-angle scattering conditions. A first-principles calculation of the single-view holographic images resolves the surface patterns’ 3D morphology with nanometer resolutions, which is critical for ultrafine nanocircuit metrology. The holographic method and simulations pave the way for single-shot structural characterization for visualizing irreversible and morphology-transforming physical and chemical processes in situ or operando .

47 OTHER INSTRUMENTATION↗

Experiments and CFD simulation of mass transfer and hydrodynamics in a cylindrical bubble column

Flow visualization, Particle Image Velocimetry (PIV) and dissolved oxygen charging experiments are carried out in a small-scale cylindrical air-water bubble column at different superficial gas velocities. Void fraction profile, total gas holdup, liquid phase velocity field and volumetric mass transfer coefficient are obtained. Details of each experiment are given, with a new procedure for obtaining a 2D void fraction profile from flow visualization by image processing and time averaging which could provide useful information for CFD model validation. The experimental results are analyzed and compared with simulations where good agreement is found for both local and global flow patterns. The averaged governing equations and constitutive relations used in the simulation are discussed briefly, with emphasis on the proper comparison between simulations and experiments based on the derivation of the two-fluid model. Finally, by conducting three sets of experiments related to phase distribution, velocity field and mass transfer in the same apparatus, a validated CFD model for multiphase mass transfer is established and can be used in the future design of a multi-phase reactor.

42 ENGINEERING↗

An Updated Visual Orbit of the Directly Imaged Exoplanet 51 Eridani b and Prospects for a Dynamical Mass Measurement with Gaia

We present a revision to the visual orbit of the young, directly imaged exoplanet 51 Eridani b using four years of observations with the Gemini Planet Imager. The relative astrometry is consistent with an eccentric (e=0.53{sub -0.13}{sup +0.09}) orbit at an intermediate inclination (i=136{sub -11}{sup +10} °), although circular orbits cannot be excluded due to the complex shape of the multidimensional posterior distribution. We find a semimajor axis of 11.1{sub -1.3}{sup +4.2} au and a period of 28.1{sub -4.9}{sup +17.2} yr, assuming a mass of 1.75 M{sub ⊙} for the host star. We find consistent values with a recent analysis of VLT/SPHERE data covering a similar baseline. We investigate the potential of using the absolute astrometry of the host star to obtain a dynamical mass constraint for the planet. The astrometric acceleration of 51 Eri derived from a comparison of the Hipparcos and Gaia catalogs was found to be inconsistent at the 2σ–3σ level with the predicted reflex motion induced by the orbiting planet. Potential sources of this inconsistency include a combination of random and systematic errors between the two astrometric catalogs and the signature of an additional companion within the system interior to current detection limits. We also explored the potential of using Gaia astrometry alone for a dynamical mass measurement of the planet by simulating Gaia measurements of the motion of the photocenter of the system over the course of the extended 8 yr mission. We find that such a measurement is only possible (>98% probability) given the most optimistic predictions for the Gaia scan astrometric uncertainties for bright stars and a high mass for the planet (≳3.6 M {sub Jup}).

79 ASTRONOMY AND ASTROPHYSICS↗

Structure Perception in 3D Point Clouds: Preprint

Understanding human perception is critical to the design of ef- fective visualizations. The relative benefits of using 2D versus 3D techniques for data visualization is a complex decision space, with varying levels of uncertainty and disagreement in both the liter- ature and in practice. This study aims to add easily reproducible, empirical evidence on the role of depth cues in perceiving structures or patterns in 3D point clouds. We describe a method to synthesize a 3D point cloud that contains a 3D structure, where 2D projec- tions of the data strongly resemble a Gaussian distribution. We performed a within-subjects structure identification study with 128 participants that compared scatterplot matrices (canonical 2D projections) and 3D scatterplots under three types of motion: rota- tion, xy-translation, and z-translation. We found that users could consistently identify three separate hidden structures under ro- tation, while those structures remained hidden in the scatterplot matrices and under translation. This work contributes a set of 3D point clouds that provide definitive examples of 3D patterns per- ceptible in 3D scatterplots under rotation but imperceptible in 2D scatterplots.

data analysis↗

AI/ML Expo Boosting Job Performance with AI: Innovative Approaches and Success Stories

Our technology leverages artificial intelligence (AI) to enhance the user experience in High Performance Computing (HPC) environments. By analyzing user behavior and providing personalized recommendations, our AI system helps HPC users optimize their workflows and improve productivity. Additionally, we offer an advanced image similarity search feature, which utilizes AI algorithms to identify and retrieve visually similar images, saving users valuable time and effort in their research and analysis.

97 - MATHEMATICS AND COMPUTING↗

Make the Fastest Faster: Importance Mask Synthesis for Interactive Volume Visualization using Reconstruction Neural Networks

Visualizing a large-scale volumetric dataset with high resolution is challenging due to the substantial computational time and space complexity. Recent deep learning-based image inpainting methods significantly improve rendering latency by reconstructing a high-resolution image for visualization in constant time on GPU from a partially rendered image where only a portion of pixels go through the expensive rendering pipeline. However, existing solutions need to render every pixel of either a predefined regular sampling pattern or an irregular sample pattern predicted from a low-resolution image rendering. Both methods require a significant amount of expensive pixel-level rendering. In this work, we provide Importance Mask Learning (IML) and Synthesis (IMS) networks, which are the first attempts to directly synthesize important regions of the regular sampling pattern from the user’s view parameters, to further minimize the number of pixels to render by jointly considering the dataset, user behavior, and the downstream reconstruction neural network. Our solution is a unified framework to handle various types of inpainting methods through the proposed differentiable compaction/decompaction layers. Experiments show our method can further improve the overall rendering latency of state-of-the-art volume visualization methods using reconstruction neural network for free when rendering scientific volumetric datasets. Our method can also directly optimize the off-the-shelf pre-trained reconstruction neural networks without elongated retraining.

Large-scale data↗

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

Pulsed Infrared Thermography Nondestructive Imaging of SiC-SiC f Composite Cladding Architectures; Understanding the Performance of SiC-SiC f Composite Cladding Architectures with Cr Coating in Normal Operating and Accident Conditions in LWRs and Advanced Reactors

SiC-SiC f composites, consisting of silicon carbide fibers embedded in a silicon carbide matrix, are advanced materials with high thermal conductivity, temperature stability, and resistance to radiation damage. Traditional methods for quality control of fabricated SiC-SiC f composites involve nondestructive evaluation (NDE) with X-ray computed tomography (XCT). However, XCT imaging of typical SiC-SiC f structures for cladding applications can involve several hours. In this project, we investigate an alternative approach to NDE of SiC-SiC f composites that involves rapid (on the order of seconds) imaging with Pulsed infrared thermography (PIT). PIT images of a planar SiC-SiC f specimen show the structure of the surface monolith layer and internal SiC f structures. The capability of PIT imaging in visualizing SiC f structures is qualitatively confirmed by observing similarity in the PIT and X-ray transmission images of the same specimen. Computer vision analysis of defects in the PIT image of the monolith was performed with thresholding followed by topological structural analysis that computed geometric descriptors, including major/minor axes of fitted ellipses, area, perimeter, Feret diameter, circularity, roundness, and solidity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Rapid custom prototyping of soft poroelastic biosensor for simultaneous epicardial recording and imaging

Abstract The growing need for the implementation of stretchable biosensors in the body has driven rapid prototyping schemes through the direct ink writing of multidimensional functional architectures. Recent approaches employ biocompatible inks that are dispensable through an automated nozzle injection system. However, their application in medical practices remains challenged in reliable recording due to their viscoelastic nature that yields mechanical and electrical hysteresis under periodic large strains. Herein, we report sponge-like poroelastic silicone composites adaptable for high-precision direct writing of custom-designed stretchable biosensors, which are soft and insensitive to strains. Their unique structural properties yield a robust coupling to living tissues, enabling high-fidelity recording of spatiotemporal electrophysiological activity and real-time ultrasound imaging for visual feedback. In vivo evaluations of custom-fit biosensors in a murine acute myocardial infarction model demonstrate a potential clinical utility in the simultaneous intraoperative recording and imaging on the epicardium, which may guide definitive surgical treatments.

36 MATERIALS SCIENCE↗