Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events

An analytical, advanced imaging method has been developed for the initial monitoring and identification of foam debris and similar anomalies that occur post-launch in reference to the space shuttle s external tank (ET). Remote sensing technologies have been used to perform image enhancement and analysis on high-resolution, true-color images collected with the DCS 760 Kodak digital camera located in the right umbilical well of the space shuttle. Improvements to the camera, using filters, have added sharpness/definition to the image sets; however, image review/analysis of the ET has been limited by the fact that the images acquired by umbilical cameras during launch are two-dimensional, and are usually nonreferenceable between frames due to rotation translation of the ET as it falls away from the space shuttle. Use of stereo pairs of these images can enable strong visual indicators that can immediately portray depth perception of damaged areas or movement of fragments between frames is not perceivable in two-dimensional images. A stereoscopic image visualization system has been developed to allow 3D depth perception of stereo-aligned image pairs taken from in-flight umbilical and handheld digital shuttle cameras. This new system has been developed to augment and optimize existing 2D monitoring capabilities. Using this system, candidate sequential image pairs are identified for transformation into stereo viewing pairs. Image orientation is corrected using control points (similar points) between frames to place the two images in proper X-Y viewing perspective. The images are then imported into the WallView stereo viewing software package. The collected control points are used to generate a transformation equation that is used to re-project one image and effectively co-register it to the other image. The co-registered, oriented image pairs are imported into a WallView image set and are used as a 3D stereo analysis slide show. Multiple sequential image pairs can be used to allow forensic review of temporal phenomena between pairs. The observer, while wearing linear polarized glasses, is able to review image pairs in passive 3D stereo.

Brown, Richard↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Glass/Glass Photovoltaic Module Reliability and Degradation: A Review - Figures

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

transparent backsheet↗

Chemical speciation correlated with microstructural heterogeneity of interdicted uranium materials

Two uranium powders seized by law enforcement in Victoria, Australia, have been characterized by established nuclear forensic methods in a previously published study. Here, in this work, the results of further characterization by a scanning transmission x-ray microscope (STXM) operating in the soft x-ray regime are reported. STXM images are used to estimate the elemental distribution in micrometer-scale particles of each powder, and oxygen K-edge absorption spectra are used to determine the chemical state of uranium. The results of the current study are consistent with the previous analysis; the first powder is found to be a potassium-uranium hydrate, while the second powder is determined to be a mixture of uranium oxides primarily consisting of UO 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Trace Impurities Identified as Forensic Signatures in CMX-5 Fuel Pellets Using X-ray Spectroscopic Techniques

We report that small-particle analysis is a highly promising emerging forensic tool for analysis of interdicted special nuclear materials. Integration of microstructural, morphological, compositional, and molecular impurity signatures could provide significant advancements in forensic capabilities. We have applied rapid, high-sensitivity, hard X-ray synchrotron chemical imaging to analyze impurity signatures in two differently fabricated fuel pellets from the 5th Collaborative Materials Exercise (CMX5) of the IAEA Nuclear Forensics International Working Group. The spatial distributions, chemical compositions, and morphological and molecular characteristics of impurities were evaluated using X-ray absorption near-edge structure (XANES) and X-ray fluorescence chemical imaging to discover principal impurities, their granularity, particle sizes, modes of occurrence (distinct grains vs incorporation in the UO 2 lattice), and sources and mechanisms of incorporation. Differences in UO 2+x stoichiometry were detected at the microscale in nominally identical UO 2 ceramics (CMX5-A and CMX5-B), implying the presence of multiple UO 2 host phases with characteristic microstructures and feedstock compositions. Al, Fe, Ni, W, and Zr impurities and integrated impurity signature analysis identified distinctly different pellet synthesis and processing methods. For example, two different Al, W, and Zr populations in the CMX5-B sample indicated a more complex processing history than the CMX5-A sample. K-edge XANES measurements reveal both metallic and oxide forms of Fe and Ni but with different proportions between each sample. Altogether, these observations suggest multiple sources of impurities, including fabrication (e.g., force-sieving) and feedstock (mineral oxides). This study demonstrates the potential of synchrotron techniques to integrate different signatures across length scales (angstrom to micrometer) to detect and differentiate between contrasting UO 2 fuel fabrication techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA Tech Briefs, June 2004

Topics covered include: COTS MEMS Flow-Measurement Probes; Measurement of an Evaporating Drop on a Reflective Substrate; Airplane Ice Detector Based on a Microwave Transmission Line; Microwave/Sonic Apparatus Measures Flow and Density in Pipe; Reducing Errors by Use of Redundancy in Gravity Measurements; Membrane-Based Water Evaporator for a Space Suit; Compact Microscope Imaging System with Intelligent Controls; Chirped-Superlattice, Blocked-Intersubband QWIP; Charge-Dissipative Electrical Cables; Deep-Sea Video Cameras Without Pressure Housings; RFID and Memory Devices Fabricated Integrally on Substrates; Analyzing Dynamics of Cooperating Spacecraft; Spacecraft Attitude Maneuver Planning Using Genetic Algorithms; Forensic Analysis of Compromised Computers; Document Concurrence System; Managing an Archive of Images; MPT Prediction of Aircraft-Engine Fan Noise; Improving Control of Two Motor Controllers; Electro-deionization Using Micro-separated Bipolar Membranes; Safer Electrolytes for Lithium-Ion Cells; Rotating Reverse-Osmosis for Water Purification; Making Precise Resonators for Mesoscale Vibratory Gyroscopes; Robotic End Effectors for Hard-Rock Climbing; Improved Nutation Damper for a Spin-Stabilized Spacecraft; Exhaust Nozzle for a Multitube Detonative Combustion Engine; Arc-Second Pointer for Balloon-Borne Astronomical Instrument; Compact, Automated Centrifugal Slide-Staining System; Two-Armed, Mobile, Sensate Research Robot; Compensating for Effects of Humidity on Electronic Noses; Brush/Fin Thermal Interfaces; Multispectral Scanner for Monitoring Plants; Coding for Communication Channels with Dead-Time Constraints; System for Better Spacing of Airplanes En Route; Algorithm for Training a Recurrent Multilayer Perceptron; Orbiter Interface Unit and Early Communication System; White-Light Nulling Interferometers for Detecting Planets; and Development of Methodology for Programming Autonomous Agents.

Source record↗

Advances in Autoradiography Systems for Nuclear Forensic Analysis

Nuclear forensic analysis techniques work to determine the contents of radiological samples with nondestructive and destructive analysis methods. Autoradiography is a nondestructive analysis method that creates an image of the distribution of radioactivity within the sample. These images allow the location of the radiological content within a sample to be ascertained, which can be used for further analysis. Autoradiography has been used since the discovery of radiation and has been continuously developed to better suit the needs of the medical, nuclear security, nuclear safeguards, and nuclear forensic communities. Recent developments in autoradiography have led to a higher spatial resolution down to a level of tens of microns, real-time capabilities that minimize the risk of overexposure, and the ability to discriminate particles. All of these developments in autoradiography would assist the nuclear forensics community in understanding the placement of radiological content within a sample and in understanding the locations of beta-particle interactions versus those for alpha-particle interactions. This article aims to discuss the history of autoradiography as well as multiple different autoradiographic technologies while focusing on imaging plates, the BeaQuant system, and the ionizing-radiation Quantum Imaging Detector system. This article reviews three autoradiographic techniques and detectors, discusses how they relate to nuclear forensics, and addresses the drawbacks and benefits of each detector.

Autoradiography↗

Mixed Element Microparticle Characterization by Electron Probe Microanalysis

Abstract Microparticle compositional characterization for nuclear forensics has traditionally been achieved by “gold-standard” destructive analytical techniques such as large geometry-secondary ion mass spectrometry and fission track-thermal ionization mass spectrometry, but long processing times and total sample consumption eliminate the option of subsequent analysis by other methods. Electron probe microanalysis has long been widely employed for rapid, nondestructive, micrometer-scale compositional measurements and imaging in fields such as material science and geology and may therefore need to be reevaluated as an alternative tool for microparticle analysis for the nuclear forensics community. This study presents the use of electron probe microanalysis for imaging and quantitative characterization of homogeneous microparticles utilizing a calibration curve based on high-precision quadrupole-inductively coupled plasma-mass spectrometry analyses. Samples of opportunity synthesized at Savannah River National Laboratory, nickel-doped cerium oxide microparticles, were selected as analogs for plutonium-doped uranium oxide microparticles. Positive detection and accurate quantification of variable amounts of nickel dopant down to trace levels (10s of parts per million) suggest applicability of this technique to other mixed element systems (e.g., actinides). Quantitative single-particle characterization via electron probe microanalyzer may thus provide a high fidelity, nondestructive complement to techniques currently in use.

Riche, Alexis T. (ORCID:0009000121978126)↗

Remote sensing; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

Advances in optical technology for remote sensing are discussed in reviews and reports of recent experimental investigations. Topics examined include industrial applications, laser diagnostics for combustion research, laser remote sensing for ranging and altimetry, and imaging systems for terrestrial remote sensing from space. Consideration is given to LIF in forensic diagnostics, time-resolved laser-induced-breakdown spectrometry for rapid analysis of alloys, CARS in practical combustion environments, airborne inertial surveying using laser tracking and profiling techniques, earth-resources instrumentation for the EOS polar platform of the Space Station, and the SAR for EOS.

Menzies, Robert T.↗

Expanding Accurate Person Recognition to New Altitudes and Ranges: The BRIAR Dataset

Face recognition technology has advanced significantly in recent years due largely to the availability of large and increasingly complex training datasets for use in deep learning models. These datasets, however, typically comprise images scraped from news sites or social media plat-forms and, therefore, have limited utility in more advanced security, forensics, and military applications. These applications require lower resolution, longer ranges, and ele-vated viewpoints. To meet these critical needs, we collected and curated the first and second subsets of a large multi-modal biometric dataset designed for use in the research and development (R&D) of biometric recognition technolo-gies under extremely challenging conditions. Thus far, the dataset includes more than 350,000 still images and over 1,300 hours of video footage of approximately 1,000 sub-jects. To collect this data, we used Nikon DSLR cameras, a variety of commercial surveillance cameras, specialized long-rage R&D cameras, and Group 1 and Group 2 UAV platforms. The goal is to support the development of algorithms capable of accurately recognizing people at ranges up to 1,000 m and from high angles of elevation. These ad-vances will include improvements to the state of the art in face recognition and will support new research in the area of whole-body recognition using methods based on gait and anthropometry. This paper describes methods used to col-lect and curate the dataset, and the dataset's characteristics at the current stage.

Brogan, Joel↗

Getting the Lowdown on Airborne Pollutants

Opto-Knowledge Systems, Inc. was founded in 1991 specifically to take advantage of the emergence of a new technology field related to spectral imaging. The technology has applications in diverse areas such as Earth remote sensing, agriculture, geology, medical diagnosis, manufacturing, forensics, and more. Under the NASA/Goddard Space Flight Center STTR project, OKSI developed several major aspects to further the state of the art, resulting in several commercial products.

Source record↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗