Hot-wire anemometry in transonic flow

The use of hot-wire anemometry for obtaining fluctuating data in transonic flows has been evaluated. From hot-wire heat loss correlations based on previous transonic data, the sensitivity coefficients for velocity, density, and total temperature fluctuations have been calculated for a wide range of test conditions and sensor parameters. For sensor Reynolds number greater than 20 and high sensor overheat ratios, the velocity sensitivity remains independent of Mach number and equal to the density sensitivity. These conditions were verified by comparisons of predicted sensitivities with those from recent direct calibrations in transonic flows. Based on these results, techniques are presented to obtain meaningful measurements of fluctuating velocity, density, and Reynolds shear stress using hot-wire and hot-film anemometers. Example of these measurements are presented for two transonic boundary layers.

Horstman, C. C.↗

Uncertainties in hot-wire measurements of compressible turbulent flows implied by comparisons with laser-induced fluorescence

A hot-wire anemometer and a new nonintrusive laser-induced fluorescence (LIF) technique are used to survey a Mach 2 turbulent boundary layer. The hot-wire anemometer's ability to accurately measure mass flux, temperature, and density fluctuations in a compressible flow is examined by comparing its results with those obtained using LIF. Several methods of hot-wire calibration are used, and the uncertainties in their measurements of various fluctuating flow parameters are determined. The results show that although a hot-wire operated at high overheat can measure mass flux fluctuations, temperature and density fluctuations are not determined accurately from such measurements. However, a hot-wire operated at multiple overheats can be used to measure static and total temperature fluctuations. The presence of pressure fluctuations and their correlation with density can prevent the use of hot-wire data to determine density fluctuations.

Mckenzie, R. L.↗

Hot-wire Anemometry and Planned Test Entries

- Hot-wire anemometers are sensitive to mass flux and total temperature - Applications for hot-wire anemometry include - Determining the flow quality within a facility - Mapping the flowfield that is influenced by a model - Mean flow distortion - Boundary-layer instabilities & transition - It’s an especially important diagnostic if there is no line of sight - We use a constant temperature anemometer (CTA) at a high overheat & calibrate the wire using a modified King’s Law

Hypersonics↗

A dual-amplifier hot-wire anemometer

The conceptual design of a dual-amplifier constant-temperature hot-wire anemometer is described. This hot-wire anemometer consists of three basic independent modules: a Wheatstone bridge in which the hot wire is one of its arms, an error-correction amplifier, and a voltage-controlled current source. The last two modules constitute the feedback network of this hot-wire anemometer. Thus the output voltage across the wire is a true function of the instantaneous changes in the wire resistance induced by the cooling effect of the flow. The dual-amplifier is capable of reaching relatively high frequency response through adequate selection of its active elements. Suitable gain of the error-correction amplifier and proper choice of the transfer function of the current source has yielded a frequency bandwidth up to 200 kHz.

Sadeh, W. Z.↗

The Measurement of Fluctuations of Air Speed by the Hot-Wire Anemometer

The hot-wire anemometer suggests itself as a promising method for measuring the fluctuating air velocities found in turbulent flow. The only obstacle is the presence of a lag due to the limited energy input which makes even a fairly small wire incapable of following rapid fluctuations with accuracy. This paper gives the theory of the lag and describes an experimental arrangement for compensating for the lag for frequencies up to 100 or more per second when the amplitude of the fluctuation is not too great. An experimental test of the accuracy of compensation and some results obtained with the apparatus in a wind-tunnel air stream are described. While the apparatus is very bulky in its present form, it is believed possible to develop a more portable arrangement. (author)

Dryden, H L↗

Hot-wire anemometry in hypersonic helium flow

Hot-wire anemometry techniques are described that have been developed and used for hypersonic-helium-flow studies. The short run time available dictated certain innovations in applying conventional hot-wire techniques. Some examples are given to show the application of the techniques used. Modifications to conventional equipment are described, including probe modifications and probe heating controls.

Wagner, R. D.↗

Analysis of the uncertainties in velocity measurements with triple hot-wire probes

A detailed computerized sensitivity analysis of the triple hot-wire equations has been performed in order to delineate the uncertainties associated with measurements of the velocity components. Absolute and relative uncertainties for the instantaneous hot-wire outputs are calculated as functions of roll and pitch angles, based on a constant probability combination of the uncertainties in the inputs. From the results, it is concluded that the small inherent difficulties associated with the triple hot-wire data do not reflect artifacts introduced by the data processing. Fixed errors present in the V and W channels of the output are due to the nonzero measuring volume of the triple wire probe, and are entirely predictable.

Frota, M. N.↗

A Hot-wire Circuit with Very Small Time Lag

A circuit for a hot-wire anemometer for the measurement of fluctuating flow is presented in the present report. The principal elements of the circuit are a Wheatstone bridge, one branch of which is the hot wire; and an electronic amplifier and a current regulator for the brief current which in combination maintain the bridge balance constant. Hence the hot wire is kept at practically constant resistance and temperature, and the time lag caused by thermal inertia of the wire is thereby reduced. Through the addition of a nonlinear amplifying stage the reading of the instrument has been rendered proportional to the velocity. A discussion of certain characteristics of the circuit and the results of related calibrating tests are given.

Weske, John R↗

A review of hot wire anemometry in transonic flows

The present paper provides a review of hot wire anemometry for compressible flows, giving particular attention to the transonic flow problem. It is pointed out that the first and most important definitive work in hot wire anemometry for compressible flows was reported by Kovasznay (1953). The existence of three independent fluctuating modes in compressible flows for small perturbations was found, taking into account the vorticity mode, the entropy mode, and the sound-wave mode. A review of Kovasznays' method for supersonic flows is also presented, and advances reported by Markovin (1956) are examined. Attention is given to experiments conducted by Horstman and Rose (1977), a general solution to the hot wire problem at transonic conditions sought by Stainback et al. (1983), and some apparent problems.

Stainback, P. C.↗

Nanoscale Hot-Wire Probes for Boundary-Layer Flows

Hot-wire probes having dimensions of the order of nanometers have been proposed for measuring temperatures (and possibly velocities) in boundary-layer flows at spatial resolutions much finer and distances from walls much smaller than have been possible heretofore. The achievable resolutions and minimum distances are expected to be of the order of tens of nanometers much less than a typical mean free path of a molecule and much less than the thickness of a typical flow boundary layer in air at standard temperature and pressure. An additional benefit of the small scale of these probes is that they would perturb the measured flows less than do larger probes. The hot-wire components of the probes would likely be made from semiconducting carbon nanotubes or ropes of such nanotubes. According to one design concept, a probe would comprise a single nanotube or rope of nanotubes laid out on the surface of an insulating substrate between two metallic wires. According to another design concept, a nanotube or rope of nanotubes would be electrically connected and held a short distance away from the substrate surface by stringing it between two metal electrodes. According to a third concept, a semiconducting nanotube or rope of nanotubes would be strung between the tips of two protruding electrodes made of fully conducting nanotubes or ropes of nanotubes. The figure depicts an array of such probes that could be used to gather data at several distances from a wall. It will be necessary to develop techniques for fabricating the probes. It will also be necessary to determine whether the probes will be strong enough to withstand the aerodynamic forces and impacts of micron-sized particles entrained in typical flows of interest.

Tedjojuwono, Ken T.↗

High speed photographic study of hot wire dynamic behavior

Investigation of hot wire dynamic behavior under high-current heating aimed at a better understanding of the ignition process, using high-speed photographic techniques for visual observation of the bridgewire itself during high current heating. Tests were conducted with Tophet A bridgewires in an air environment, as well as in a cell of distilled water at room temperature, and with a boron-potassium perchlorate-Viton pyrotechnic against the bridgewire behind a Plexiglas window.

Sernas, V.↗

Landing Gear Components Noise Study - PIV and Hot-Wire Measurements

PIV and hot-wire measurements of the wake flow from rods and bars are presented. The test models include rods of different diameters and cross sections and a rod juxtaposed to a plate. The latter is representative of the latch door that is attached to an aircraft landing gear when the gear is deployed, while the single and multiple rod configurations tested are representative of some of the various struts and cables configuration present on an aircraft landing gear. The test set up is described and the flow measurements are presented. The effect of model surface treatment and freestream turbulence on the spanwise coherence of the vortex shedding is studied for several rod and bar configurations.

Hutcheson, Florence V.↗

Development of subminiature multi-sensor hot-wire probes

Limitations on the spatial resolution of multisensor hot wire probes have precluded accurate measurements of Reynolds stresses very near solid surfaces in wind tunnels and in many practical aerodynamic flows. The fabrication, calibration and qualification testing of very small single horizontal and X-array hot-wire probes which are intended to be used near solid boundaries in turbulent flows where length scales are particularly small, is described. Details of the sensor fabrication procedure are reported, along with information needed to successfully operate the probes. As compared with conventional probes, manufacture of the subminiature probes is more complex, requiring special equipment and careful handling. The subminiature probes tested were more fragile and shorter lived than conventional probes; they obeyed the same calibration laws but with slightly larger experimental uncertainty. In spite of these disadvantages, measurements of mean statistical quantities and spectra demonstrate the ability of the subminiature sensors to provide the measurements in the near wall region of turbulent boundary layers that are more accurate than conventional sized probes.

Westphal, Russell V.↗

Flying-hot-wire study of two-dimensional mean flow past an NACA 4412 airfoil at maximum lift

Hot-wire measurements have been made in the boundary layer, the separated region, and the near wake for flow past an NACA 4412 airfoil at maximum lift. The Reynolds number based on chord was about 1,500,000. The main instrumentation was a hot-wire probe mounted on the end of a rotating arm. A digital computer was used to control synchronized sampling of hot-wire data at closely spaced points along the probe arc. Ensembles of data were obtained at several thousand locations in the flow field. The data include intermittency, two components of mean velocity, and twelve mean values for double, triple, and quadruple products of two velocity fluctuations. The data are available on punched cards in raw form and also after use of smoothing and interpolation routines to obtain values on a fine rectangular grid aligned with the airfoil chord. The data are displayed in the paper as contour plots.

Coles, D.↗

Hot wire anemometer measurements in the unheated air flow tests of the SRB nozzle-to-case joint

Hot-Wire Anemometer measurements made in the Solid Rocket Booster (SRB) nozzle-to-case joint are discussed. The study was undertaken to glean additional information on the circumferential flow induced in the SRB nozzle joint and the effect of this flow on the insulation bonding flaws. The tests were conducted on a full-scale, 2-D representation of a 65-in long segment of the SRB nozzle joint, with unheated air as the working fluid. Both the flight Mach number and Reynolds number were matched simultaneously and different pressure gradients imposed along the joint face were investigated. Hot-wire anemometers were used to obtain velocity data for different joint gaps and debond configurations. The procedure adopted for hot-wire calibration and use is outlined and the results from the tests summarized.

Ramachandran, N.↗

A hot-wire method for high-intensity turbulent flows

A measuring technique for determing instantaneous, three-dimensional velocity vectors in highly turbulent flows by means of a 4-sensor hot-wire probe is described. As is well known, the hot-wire signal received in reversing flows cannot uniquely be interpreted. This difficulty is circumvented by tracking the thermal wake of a heated wire. Whenever the approximate flow direction is indicated by a temperature-sensitive wake detector, all components of the instantaneous velocity vector are evaluated by means of a digital data reduction method. Uniqueness of the solution derived from the triple-hot-wire response equations is examined. A first application of the proposed measuring technique in the recirculating flow downstream of a backward-facing step is described.

Mueller, U. R.↗

Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

Unsteady active flow control (AFC) has been used experimentally for many years to minimize bluff-body drag. This technology could significantly improve performance of rotorcraft by cleaning up flow separation. It is important, then, that new actuator technologies be studied for application to future vehicles. A boundary layer wind tunnel was constructed with a 1ft-x-3ft test section and unsteady measurement instrumentation to study how AFC manipulates the boundary layer to overcome adverse pressure gradients and flow separation. This unsteady flow control research requires unsteady measurement methods. In order to measure the boundary layer characteristics, both hot-wire and hot-film Constant Temperature Anemometry is used. A hot-wire probe is mounted in the flow to measure velocity while a hot-film array lays on the test surface to measure skin friction. Hot-film sensors are connected to an anemometer, a Wheatstone bridge circuit with an output that corresponds to the dynamic flow response. From this output, the time varying flow field, turbulence, and flow reversal can be characterized. Tuning the anemometers requires a fan test on the hot-film sensors to adjust each output. This is a delicate process as several variables drastically affect the data, including control resistance, signal input, trim, and gain settings.

Control Test↗