Engineering PapersSearch

SEARCH · Engineering Papers

Results for “holders”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spring-Loaded Transducer Holder

Portable ultrasonic scanner moves transducer at constant pressure. Spring-loaded holder moves ultrasonic transducer over test sample at constant pressure. Setup used to determine rate of debond taking place in glued materials subjected to fatigue loading. Holder designed as portable field unit adapted to fatigue machine that transmits data while specimen tested.

Gardner, M. R.

Holder for Tinning Microcircuit Leads

Heat-sinking tool holds microcircuits for lead tinning while protecting circuits from heat of tinning solder. Microcircuit holder dips leads in molten solder. Holder shields microcircuit from solder heat while leads immersed and absorbs heat conducted through leads. Thus keeps microcircuit relatively cool. Application tool was developed for requires tinning not closer than 0.02 in. (0.5 mm) from package body or its glass seals.

Gilbert, G. G.

Numerical prediction of cold turbulent flow in combustor configurations with different centerbody flame holders

A numerical study of cold turbulent flow in a combustor containing a centerbody flame holder is presented. The axisymmetric Navier-Stokes equations incorporating a k-epsilon turbulence model were solved in a nonorthogonal curvilinear coordinate system. The finite volume method, applied to a staggered grid system, was used to discretize the differential equations. These finite differenced equations were then solved iteratively utilizing the SIMPLE algorithm described by Patankar (1980). Solutions were obtained for two combustor duct geometries with various centerbody flame holders which included a disk, a cone, and a sphere. The extent of mixing due to these bodies was evaluated. A comparison with previously obtained experimental data yielded moderately good agreement.

Yung, C. N.

Sample holder support for microscopes

A sample filter holder is disclosed for use with a microscope for holding the filter in a planar condition on the stage of the microscope so that automatic focusing of the microscope can be performed on particle samples dispersed on the filter. The holder includes a base having a well that communicates with an inlet port which is connected to a suction pump. A screen assembly is positioned within the well. The screen assembly includes a disk having a screen positioned on its top surface and secured to the disk at the peripheral edge of the screen. Small bores allow the outer surface of the screen to communicate with the well. The filter is placed on the screen and is held in a flat disposition by the suction forces.

Berry, Anthony

Book Holder And Page Turner For The Elderly And Handicapped

Device holds reading matter and facilitates page turning for person not having use of arms and hands. Accommodates variety of publication formats, whether book, magazine, or newspaper. Holder sits on hospital-bed table and adjusted to convenient viewing angle. Includes flat upright back support for reading matter, hinged base, and main bracket with bent-wire page holders. Top support on back extended for such large items as newspapers. Wings on back support extended for oversize materials. Reader turns page by gripping special rod via mouthpiece, applying friction cup at its tip to page, and manipulating rod. Mouthpiece wide and tapered so user grips with teeth and uses jaws to move it, rather than using tongue or lips. Helpful to older people, whose facial and mouth muscles weak.

Kerley, James

Silicon Holder For Molecular-Beam Epitaxy

Simple assembly of silicon wafers holds silicon-based charge-coupled device (CCD) during postprocessing in which silicon deposited by molecular-beam epitaxy. Attains temperatures similar to CCD, so hotspots suppressed. Coefficients of thermal expansion of holder and CCD equal, so thermal stresses caused by differential thermal expansion and contraction do not develop. Holder readily fabricated, by standard silicon processing techniques, to accommodate various CCD geometries. Silicon does not contaminate CCD or molecular-beam-epitaxy vacuum chamber.

Hoenk, Michael E.

Silicon sample holder for molecular beam epitaxy on pre-fabricated integrated circuits

The sample holder of the invention is formed of the same semiconductor crystal as the integrated circuit on which the molecular beam expitaxial process is to be performed. In the preferred embodiment, the sample holder comprises three stacked micro-machined silicon wafers: a silicon base wafer having a square micro-machined center opening corresponding in size and shape to the active area of a CCD imager chip, a silicon center wafer micro-machined as an annulus having radially inwardly pointing fingers whose ends abut the edges of and center the CCD imager chip within the annulus, and a silicon top wafer micro-machined as an annulus having cantilevered membranes which extend over the top of the CCD imager chip. The micro-machined silicon wafers are stacked in the order given above with the CCD imager chip centered in the center wafer and sandwiched between the base and top wafers. The thickness of the center wafer is about 20% less than the thickness of the CCD imager chip. Preferably, four titanium wires, each grasping the edges of the top and base wafers, compress all three wafers together, flexing the cantilever fingers of the top wafer to accommodate the thickness of the CCD imager chip, acting as a spring holding the CCD imager chip in place.

Hoenk, Michael E.

Helical spring holder assembly

A helically-threaded spring holder on which a helically wound spring is mounted has a groove formed in one side of the thread at the end where the spring engages the spring holder. The groove relieves the portion of the side in which it is formed from restricting the spring against axial movement during deflection of the spring. The circumferential length of this groove is chosen to establish the number of spring coils which can be deflected without contacting the side of the thread. The end of the thread is also made rigid to prevent flexing thereof during maximal elongation of the spring.

Newman, Wyatt S.

Quick-Change Ceramic Flame Holder for High-Output Torches

Researchers at NASA's Langley Research Center have developed a new ceramic design flame holder with a service temperature of 4,000 F (2,204 C). The combination of high strength and high temperature capability, as well as a twist-lock mounting method to the steel burner, sets this flame holder apart from existing technology.

Haskin, Henry

A Spaceflight Experiment to Determine the Effect of Chamfered Sample Holders on Atomic Oxygen Erosion

The exteriors of low Earth orbit (LEO) spacecraft are subjected to many environmental threats that can cause the surface materials to degrade. One of these threats is atomic oxygen (AO), which is formed by photo dissociation of molecular oxygen by energetic UV radiation. Atomic oxygen exposure can result in oxidative erosion of polymers leading to structural or thermal failure of spacecraft components. The amount of AO erosion expected during a mission can be calculated by knowing the AO erosion yield (Ey, volume loss per incident atom) of the material and the AO fluence expected for the mission. The Ey can be determined through dehydrated mass loss measurements of test samples if one knows the AO fluence, density, and exposure area. Such measurements have been made as part of flight experiments, including the Materials International Space Station Experiment 2 (MISSE 2) Polymers Experiment. The MISSE 2 Polymers Experiment sample holders had chamfered circular apertures that controlled the exposure area, but also allowed some additional AO to scatter from the chamfered edges onto the samples thus causing some samples to erode thru and peel at their perimeter due to this scattering effect. By modeling the scattered AO flux one can predict the actual total AO fluence, and hence more accurate sample Ey. Sample holders with different chamfered-perimeter to exposed-area ratios have been designed for future spaceflight experiments that allow a more accurate determination of the Ey for large area polymers, representative of their use on spacecraft surfaces.

Earth Orbital Environments

Effects of Sample Holder Edge Geometry on Atomic Oxygen Erosion Yield of Pyrolytic Graphite Exposed in Low Earth Orbit

The measurement of the erosion yield (volume lost per incident atom) of polymers and carbon using low Earth orbital (LEO) atomic oxygen exposure has typically involved placing small samples in holders that have chamfered edges. The chamfered edges have sometimes cause the samples to tear by their perimeters. This paper reports an evaluation of the erosion profile of a LEO atomic oxygen exposed pyrolytic graphite sample to determine the extent to which the erosion yield is altered by the chamfer and what the expected erosion yield would be for large area samples. The results indicate that the durability of large area samples would be approx. 5.2% lower than predicted based on mass loss of small samples with exposed diameters of 0.838 inch (2.13 cm) and chamfered sample holders.

erosion yield

Specimen Holder Design Improves Accuracy of X-Ray Powder Analysis

Specimen holder for X ray diffraction analysis presents the specimen to the incident X rays in a curvature. This permits the use of an X ray beam having a larger divergence angle, the beam intensity is increased, and the statistical accuracy of analysis is improved.

Mack, M.

X-ray film holder permits single continuous picture of tubing joint

X ray technique produces a clear continuous picture of a welded brazed tubing joint on a single film with one exposure. A stationary X ray source located in the plane of the joint to be inspected, a means of rotating the tube, and a unique internal film holder and positioning fixture are used.

Diamond, J. W.

A space qualified radiation source holder

A radiation source holder was developed to permit controlled exposure of biological material to a gamma-emitting radiation source during flight in a recoverable earth-orbiting satellite. A unique spring drive mechanism, activated by real time commands from the ground station, moved the Sr-85 source from a shielded position to the exposed position and then back to the shielded condition before reentry and recovery. A fail-safe feature utilized the reentry deceleration force to ensure that the source would be in a shielded position during the recovery operations. The device was successfully flown on Biosatellite 2.

Polaski, L. J.