Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high performance analytics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MERRA Analytic Services: Meeting the Big Data Challenges of Climate Science Through Cloud-enabled Climate Analytics-as-a-service

Climate science is a Big Data domain that is experiencing unprecedented growth. In our efforts to address the Big Data challenges of climate science, we are moving toward a notion of Climate Analytics-as-a-Service (CAaaS). We focus on analytics, because it is the knowledge gained from our interactions with Big Data that ultimately produce societal benefits. We focus on CAaaS because we believe it provides a useful way of thinking about the problem: a specialization of the concept of business process-as-a-service, which is an evolving extension of IaaS, PaaS, and SaaS enabled by Cloud Computing. Within this framework, Cloud Computing plays an important role; however, we it see it as only one element in a constellation of capabilities that are essential to delivering climate analytics as a service. These elements are essential because in the aggregate they lead to generativity, a capacity for self-assembly that we feel is the key to solving many of the Big Data challenges in this domain. MERRA Analytic Services (MERRAAS) is an example of cloud-enabled CAaaS built on this principle. MERRAAS enables MapReduce analytics over NASAs Modern-Era Retrospective Analysis for Research and Applications (MERRA) data collection. The MERRA reanalysis integrates observational data with numerical models to produce a global temporally and spatially consistent synthesis of 26 key climate variables. It represents a type of data product that is of growing importance to scientists doing climate change research and a wide range of decision support applications. MERRAAS brings together the following generative elements in a full, end-to-end demonstration of CAaaS capabilities: (1) high-performance, data proximal analytics, (2) scalable data management, (3) software appliance virtualization, (4) adaptive analytics, and (5) a domain-harmonized API. The effectiveness of MERRAAS has been demonstrated in several applications. In our experience, Cloud Computing lowers the barriers and risk to organizational change, fosters innovation and experimentation, facilitates technology transfer, and provides the agility required to meet our customers' increasing and changing needs. Cloud Computing is providing a new tier in the data services stack that helps connect earthbound, enterprise-level data and computational resources to new customers and new mobility-driven applications and modes of work. For climate science, Cloud Computing's capacity to engage communities in the construction of new capabilies is perhaps the most important link between Cloud Computing and Big Data.

Data Analytics↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

Conical-reflector antennas.

The mechanical advantages of a singly curved conical reflector are demonstrated by the experimental test of a furlable 1.83 m conical-Gregorian antenna at 16.33 GHz. The measured gain of 47.5 dB corresponds to a net efficiency of over 57%. A ray-optics analysis of conical-reflector antennas is presented, and data useful in the design of conical antennas are given. The conical-Gregorian antenna, in which a subreflector is used in conjunction with a conventional horn feed, is considered in detail. A physical-optics analysis of the conical-Gregorian antenna is used to investigate diffraction and other effects, and to analytically confirm the high performance of the antenna.

Ludwig, A. C.↗

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Silane primers for use as thermal protection on external tanks were subjected to various analytic techniques to determine the most effective testing method for silane lot evaluation. The analytic methods included high performance liquid chromatography, gas chromatography, thermogravimetry (TGA), and fourier transform infrared spectroscopy (FTIR). It is suggested that FTIR be used as the method for silane lot evaluation. Chromatograms, TGA profiles, bar graphs showing IR absorbances, and FTIR spectra are presented.

Mikes, F.↗

Effects of turbine cooling assumptions on performance and sizing of high-speed civil transport

The analytical study presented examines the effects of varying turbine cooling assumptions on the performance of a high speed civil transport propulsion system as well as the sizing sensitivity of this aircraft to these performance variations. The propulsion concept employed in this study was a two spool, variable cycle engine with a sea level thrust of 55,000 lbf. The aircraft used for this study was a 250 passenger vehicle with a cruise Mach number of 2.4 and 5000 nautical mile range. The differences in turbine cooling assumptions were represented by varying the amount of high pressure compressor bleed air used to cool the turbines. It was found that as this cooling amount increased, engine size and weight increased, but specific fuel consumption (SFC) decreased at takeoff and climb only. Because most time is spent at cruise, the SFC advantage of the higher bleed engines seen during subsonic flight was minimized and the lower bleed, lighter engines led to the lowest takeoff gross weight vehicles. Finally, the change in aircraft takeoff gross weight versus turbine cooling level is presented.

Senick, Paul F.↗

Effects of turbine cooling assumptions on performance and sizing of high-speed civil transport

The analytical study presented examines the effects of varying turbine cooling assumptions on the performance of a high speed civil transport propulsion system as well as the sizing sensitivity of this aircraft to these performance variations. The propulsion concept employed in this study was a two spool, variable cycle engine with a sea level thrust of 55,000 lbf. The aircraft used for this study was a 250 passenger vehicle with a cruise Mach number of 2.4 and 500 nautical mile range. The differences in turbine cooling assumptions were represented by varying amount of high pressure compressor bleed air used to cool the turbines. It was found that as this cooling amount increased, engine size and weight increased, but specific fuel consumption (SFC) decreased at takeoff and climb only. Because most time is spent at cruise, the SFC advantage of the higher bleed engines seen during subsonic flight was minimized and the lower bleed, lighter engines led to the lowest takeoff gross weight vehicles. Finally, the change in aircraft takeoff gross weight versus turbine cooling level is presented.

Senick, Paul F.↗

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.↗

Integrated Requirements Analysis and Technology Roadmaps

In fiscal year 1997, Strategic Insight performed analytical studies for NASA's Highly Reusable Space Transportation (HRST) program, creating program documents which illuminated technical requirements and critical research opportunities. Studies were performed to structure and confirm HRST's evolving technical requirements, building on Marshall's Phase 1 work, which defined HRST system concepts, analytical tools and high-level issues for assessment in Phase 2. Specifically, Strategic Insight: (1) Performed a requirements analysis to update HRST: An Advanced Concepts Study, Study Guidelines, Version 2.0 of January 22, 1996; only minor changes were recommended for the given parameters of interest to concept designers; (2) Conducted mini-workshops during HRST Working Group meetings on April 14-15, 1997 and July 22-24, 1997; and (3) Created structures for technology road maps of candidate HRST concepts, both subsystem and end-to-end concepts, emerging from the 13 cooperative agreement projects.

Source record↗

Climate Analytics as a Service

Climate science is a big data domain that is experiencing unprecedented growth. In our efforts to address the big data challenges of climate science, we are moving toward a notion of Climate Analytics-as-a-Service (CAaaS). CAaaS combines high-performance computing and data-proximal analytics with scalable data management, cloud computing virtualization, the notion of adaptive analytics, and a domain-harmonized API to improve the accessibility and usability of large collections of climate data. MERRA Analytic Services (MERRA/AS) provides an example of CAaaS. MERRA/AS enables MapReduce analytics over NASA's Modern-Era Retrospective Analysis for Research and Applications (MERRA) data collection. The MERRA reanalysis integrates observational data with numerical models to produce a global temporally and spatially consistent synthesis of key climate variables. The effectiveness of MERRA/AS has been demonstrated in several applications. In our experience, CAaaS is providing the agility required to meet our customers' increasing and changing data management and data analysis needs.

big data↗

Analytical and Experimental Demonstration of an Alternate Mixing Performance Metric for High-Speed Fuel Mixing Studies

To experimentally assess the fuel/air mixing performance of high-speed fuel injectors, one-dimensional metrics that quantify the degree of mixing completeness downstream of the fuel injection location are required. The most accurate assessment of mixing performance is achieved with the mixing efficiency parameter. In order to experimentally determine the mixing efficiency parameter, the spatial distributions of both mass flux and fuel mass fraction must be measured. In-stream gas sampling techniques are commonly used to measure the fuel mass fraction distribution; however, the mass flux distribution is not easily determined because it requires the measurement of three independent aerothermodynamic variables in addition to the gas composition. Therefore, to experimentally determine the mixing efficiency parameter, the spatial distributions of four independent properties must be measured, with each property generally requiring its own unique probe. Because of this difficulty, it is commonly assumed that alternate metrics, which rely solely on the fuel distribution, are good indicators of mixing performance. However, since these alternate metrics do not provide a mass flux-weighted measure of mixing completeness, they can lead to incorrect conclusions being drawn about the mixing performance of the studied fuel injector configuration. Recognizing this shortcoming, this work proposes two new alternate mixing performance metrics that are easier to obtain than the mixing efficiency parameter. The analytical development of the new metrics, as well as their application to relevant CFD and experimental data of high-speed fuel injector configurations, is presented in this work. For two different experiments, the new metrics are shown to provide an excellent representation of the true mass flux-weighted mixing performance, unlike the traditionally-used alternatives. The results presented herein suggest that the new metrics can serve as accurate surrogates for mixing efficiency in future high-speed fuel/air mixing studies.

Cody R Ground↗

Climate Analytics as a Service

Exascale computing, big data, and cloud computing are driving the evolution of large-scale information systems toward a model of data-proximal analysis. In response, we are developing a concept of climate analytics as a service (CAaaS) that represents a convergence of data analytics and archive management. With this approach, high-performance compute-storage implemented as an analytic system is part of a dynamic archive comprising both static and computationally realized objects. It is a system whose capabilities are framed as behaviors over a static data collection, but where queries cause results to be created, not found and retrieved. Those results can be the product of a complex analysis, but, importantly, they also can be tailored responses to the simplest of requests. NASA's MERRA Analytic Service and associated Climate Data Services API provide a real-world example of climate analytics delivered as a service in this way. Our experiences reveal several advantages to this approach, not the least of which is orders-of-magnitude time reduction in the data assembly task common to many scientific workflows.

big data↗

High performance N2O4/amine elements blowapart

An experimental and analytical program was conducted to develop an understanding of the mechanisms controlling hypergolic propellant reactive stream separation (RSS). RSS is a combustion induced phenomenon that results in striation of hypergolic propellant oxidizer and fuel sprays fans. This reduced intraelement mixing can influence thrust chamber performance, heat transfer, and stability. The program and product were the development of design criteria for coping with RSS to allow the design of high performance, stable injectors.

Lawver, B. R.↗

Detonation propulsion for high pressure environments

One limitation encountered by chemical rocket propulsion in high pressure planetary atmospheres is illustrated by the conflict between the dependence of specific impulse on the ratio of chamber pressure to ambient pressure and the dependence of the motor structural design on the difference between the pressures. This work proposes to resolve the difficulty by employing detonating propellant in which the high pressures necessary for efficient propulsion are developed over a short time and need not be contained statically. Experimental results are presented to substantiate this claim of relatively high performance, together with an analytical development that approximately describes the flow dynamics.

Varsi, G.↗

Probabilistic structural analysis computer code (NESSUS)

Probabilistic structural analysis has been developed to analyze the effects of fluctuating loads, variable material properties, and uncertain analytical models especially for high performance structures such as SSME turbopump blades. The computer code NESSUS (Numerical Evaluation of Stochastic Structure Under Stress) was developed to serve as a primary computation tool for the characterization of the probabilistic structural response due to the stochastic environments by statistical description. The code consists of three major modules NESSUS/PRE, NESSUS/FEM, and NESSUS/FPI. NESSUS/PRE is a preprocessor which decomposes the spatially correlated random variables into a set of uncorrelated random variables using a modal analysis method. NESSUS/FEM is a finite element module which provides structural sensitivities to all the random variables considered. NESSUS/FPI is Fast Probability Integration method by which a cumulative distribution function or a probability density function is calculated.

Shiao, Michael C.↗

Probability of failure and risk assessment of propulsion structural components

The probabilistic structural analysis method (PSAM) was developed to analyze the effects of fluctuating loads, variable material properties, and uncertain analytical models especially for high performance structures such as the Space Shuttle Main Engine turbopump blades. Risk is calculated after expensive service experience. However, probabilistic structural analysis provides a rational alternative method to quantify uncertainties in the structural performance and durability. NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) was developed as a probabilistic structural analysis computer code which integrates finite element methods and reliability algorithms, capable to predicting the probability distributions of structural response variables such as stress, displacement, natural frequencies, and buckling loads. This computer code is detailed.

Shiao, Michael C.↗

Permeation Resistance of Chlorinated Polyethylene Against Hydrazine Fuels

The permeation resistance of chlorinated polyethylene (CPE) used in chemical protective clothing against the aerospace fuels hydrazine, monomethylhydrazine (MMH), and uns-dimethylhydrazine (UDMH) was determined by measuring breakthrough times and time-averaged vapor transmission rates using an ASTM F 739 permeation cell. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Breakthrough was observed after exposure to liquid MMH, and to vapor and liquid UDMH. No breakthrough was observed after exposure to vapor and liquid hydrazine, or vapor MMH. A model was then used to calculate propellant concentrations inside a totally encapsulating chemical protective suit based on the ASTM permeation data obtained in the present study. Concentrations were calculated under conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng sq cm/min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L/min). Above these permeation rates, the 10 parts per billion (ppb) threshold limit value time - weighted average could be exceeded for chemical protective suits having a CPE torso. To evaluate suit performance at ppb level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential.

Waller, J. M.↗

A high heat flux experiment for verification of thermostructural analysis

A major concern in advancing the state of the art technologies for hypersonic vehicles is the development of an aeropropulsion system capable of handling the high heat fluxes during flight. The leading edges of such systems must not only tolerate the maximum heating rates, but must also minimize distortions to the flow field due to excessive blunting and/or thermal warping of the compression surface to achieve the high inlet performance required. A combined analytical and experimental effort to study the aerothermodynamic loads on actively cooled structures for hypersonic applications was established. A hydrogen/oxygen rocket engine was modified to establish a high enthalpy high heat flux environment. The facility provides heat flux levels from about 200 up to 10000 Btu/sq ft/sec. Cross flow and parallel flow regeneratively cooled model can be tested and analyzed by using cooling fluids of water and hydrogen. Results are presented of the experiment and the characteristics of the Hot Gas Test Facility. The predicted temperature results of the cross flow model are compared with the experimental data on the first monolithic specimens and are found to be in good agreement. Thermal stress analysis results are also presented.

Gladden, Herbert J.↗

A high heat flux experiment for verification of thermostructural analysis

A major concern in advancing the state of the art technologies for hypersonic vehicles is the development of an aeropropulsion system capable of handling the high heat fluxes during flight. The leading edges of such systems must not only tolerate the maximum heating rates, but must also minimize distortions to the flow field due to excessive blunting and/or thermal warping of the conmpression surface to achieve the high inlet performance required. A combined analytical and experimental effort to study the aerothermodynamic loads on actively cooled structures for hypersonic applications was established. A hydrogen/oxygen rocket engine was modified to establish a high enthalpy high heat flux environment. The facility provides heat flux levels from about 200 up to 10000 Btu/sq ft/sec. Cross flow and parallel flow regeneratively cooled model can be tested and analyzed by using cooling fluids of water and hydrogen. Results are presented of the experiment and the characteristics of the Hot Gas Test Facility. The predicted temperature results of the cross flow model are compared with the experimental data on the first monolithic specimens and are found to be in good agreement. Thermal stress analysis results are also presented.

Gladden, H. J.↗