Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high fundamental frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High-dimensional discrete Fourier transform gates with a quantum frequency processor

The discrete Fourier transform (DFT) is of fundamental interest in photonic quantum information, yet the ability to scale it to high dimensions depends heavily on the physical encoding, with practical recipes lacking in emerging platforms such as frequency bins. In this article, we show that d -point frequency-bin DFTs can be realized with a fixed three-component quantum frequency processor (QFP), simply by adding to the electro-optic modulation signals one radio-frequency harmonic per each incremental increase in d . We verify gate fidelity F W > 0.9997 and success probability P W > 0.965 up to d = 10 in numerical simulations, and experimentally implement the solution for d = 3, utilizing measurements with parallel DFTs to quantify entanglement and perform tomography of multiple two-photon frequency-bin states. Our results furnish new opportunities for high-dimensional frequency-bin protocols in quantum communications and networking.

97 MATHEMATICS AND COMPUTING↗

Infrared detector responsivity measured simultaneously at multiple frequencies

The responsivity (the ratio of the output electrical signal to the incident radiation power) of an IR detector is measured at several frequencies simultaneously. A computer-controlled variable frequency chopper is used. Chopper modulation of a blackbody is square-wave-like, hence measurements can be taken not only at the fundamental frequency but also at the harmonics. The technique gives excellent agreement with the classical technique of measuring the fundamental response alone at a set of modulation frequencies. With a small enough aperture and a high enough chopper speed, agreement can be within five percent out to 31 times the fundamental frequency. The technique allows the rapid and automated acquisition of the frequency response of IR detectors, which may then be screened for responsivity, noise, and noise equivalent power.

Brasunas, John C.↗

Passive imaging through the turbulent atmosphere - Fundamental limits on the spatial frequency resolution of a rotational shearing interferometer

The signal-to-noise (S/N) ratio to be expected when a 180 deg rotationally shearing interferometer is used for image recovery at the diffraction limit of a large telescope is computed. The variance and covariance of the irradiance fluctuations at the detector array are shown to yield measures of the high-frequency spatial spectrum of the source. Four fundamental sources of noise are considered: temporal fluctuations of the source, space-time fluctuations of the atmosphere, shot noise in the detected photocurrents, and the effects of finite sampling. S/N is found to be directly proportional to the angular resolution of the telescope, the single-frame integration time, the square root of the number of frames, the cube of the operating wavelength, the quantum efficiency of the detector, and the average spectral irradiance from the source on the pupil. It is inversely proportional to the cube of the field angle subtended by the source (or part thereof) under study.

Burke, J. J.↗

Decoupling excitons from high-frequency vibrations in organic molecules

The coupling of excitons in π-conjugated molecules to high-frequency vibrational modes, particularly carbon–carbon stretch modes (1,000–1,600 cm -1 ) has been thought to be unavoidable. These high-frequency modes accelerate non-radiative losses and limit the performance of light-emitting diodes, fluorescent biomarkers and photovoltaic devices. Here, by combining broadband impulsive vibrational spectroscopy, first-principles modelling and synthetic chemistry, we explore exciton–vibration coupling in a range of π-conjugated molecules. We uncover two design rules that decouple excitons from high-frequency vibrations. First, when the exciton wavefunction has a substantial charge-transfer character with spatially disjoint electron and hole densities, we find that high-frequency modes can be localized to either the donor or acceptor moiety, so that they do not significantly perturb the exciton energy or its spatial distribution. Second, it is possible to select materials such that the participating molecular orbitals have a symmetry-imposed non-bonding character and are, thus, decoupled from the high-frequency vibrational modes that modulate the π-bond order. We exemplify both these design rules by creating a series of spin radical systems that have very efficient near-infrared emission (680–800 nm) from charge-transfer excitons. We show that these systems have substantial coupling to vibrational modes only below 250 cm -1 , frequencies that are too low to allow fast non-radiative decay. This enables non-radiative decay rates to be suppressed by nearly two orders of magnitude in comparison to π-conjugated molecules with similar bandgaps. Our results show that losses due to coupling to high-frequency modes need not be a fundamental property of these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical simulation of nonlinear development of instability waves

The nonlinear interactions of high amplitude instability waves in turbulent jets are described. In plane shear layers Riley and Metcalf (1980) and Monkewitz (1987) have shown that these interactions are dependent, among other parameters, on the phase-difference between the two instability waves. Therefore, here researchers consider the nonlinear development of both the amplitudes and the phase of the instability waves. The development of these waves are also coupled with the development of the mean flow and the background turbulence. In formulating this model it is assumed that each of the flow components can be characterized by conservation equations supplemented by closure models. Results for the interactions between the two instability waves under high-amplitude forcing at fundamental and subharmonic frequencies are presented here. Qualitative agreements are found between the present predictions and available experimental data.

Mankbadi, Reda R.↗

Search for TeV gamma-ray emission from Hercules X-1

Six years of observations of Hercules X-1 with the Whipple Observatory gamma-ray telescope have been subjected to a Fourier analysis to search for emission at the 0.8079 Hz neutron star frequency. Evidence for a signal is found at the 99.5 percent confidence level for data taken with the medium-resolution imaging camera with some indications of emission at frequencies blueshifted from the fundamental frequency. However, analysis of the high-resolution camera data base have failed to substantiate this effect. Selection of events on the basis of gamma-ray-like image parameters did not enhance the signal from the medium-resolution data nor produce any indication of a signal from the high-resolution data. The overall conclusion is that no statistically significant evidence for TeV gamma-ray emission was found in the Whipple Observatory data base when the 6 years of data are taken as a whole.

Reynolds, P. T.↗

Spatial-frequency spectrum of patterns changes the visibility of spatial-phase differences

It is shown that spatial-frequency components over a 4-octave range affected the visibility of spatial-phase differences. Contrast thresholds were measured for discrimination between two (+45- and -45-deg) spatial phases of a sinusoidal test grating added to a background grating. The background could contain one or several sinusoidal components, all in 0-deg phase. Phase differences between the test and the background were visible at lower contrasts when test and background frequencies were harmonically related than when they were not, when test and background frequencies were within 1 octave than when they were farther apart, when the fundamental frequency of the background was low than when it was high, and for some discriminations more than for others, after practice. The visibility of phase differences was not affected by additional components in the background if the fundamental and difference frequencies of the background remained unchanged. Observers' reports of their strategies gave information about the types of attentive processing that were used to discriminate phase differences. Attentive processing facilitated phase discrimination for multifrequency gratings spanning a much wider range of spatial frequencies than would be possible by using only local preattentive processing. These results were consistent with the visibility of phase differences being processed by some combination of even- and odd-symmetric simple cells tuned to a wide range of different spatial frequencies.

Lawton, T. B.↗

Accurate ab initio Quartic Force Fields of Cyclic and Bent HC2N Isomers

Highly correlated ab initio quartic force field (QFFs) are used to calculate the equilibrium structures and predict the spectroscopic parameters of three HC2N isomers. Specifically, the ground state quasilinear triplet and the lowest cyclic and bent singlet isomers are included in the present study. Extensive treatment of correlation effects were included using the singles and doubles coupled-cluster method that includes a perturbational estimate of the effects of connected triple excitations, denoted CCSD(T). Dunning s correlation-consistent basis sets cc-pVXZ, X=3,4,5, were used, and a three-point formula for extrapolation to the one-particle basis set limit was used. Core-correlation and scalar relativistic corrections were also included to yield highly accurate QFFs. The QFFs were used together with second-order perturbation theory (with proper treatment of Fermi resonances) and variational methods to solve the nuclear Schr dinger equation. The quasilinear nature of the triplet isomer is problematic, and it is concluded that a QFF is not adequate to describe properly all of the fundamental vibrational frequencies and spectroscopic constants (though some constants not dependent on the bending motion are well reproduced by perturbation theory). On the other hand, this procedure (a QFF together with either perturbation theory or variational methods) leads to highly accurate fundamental vibrational frequencies and spectroscopic constants for the cyclic and bent singlet isomers of HC2N. All three isomers possess significant dipole moments, 3.05D, 3.06D, and 1.71D, for the quasilinear triplet, the cyclic singlet, and the bent singlet isomers, respectively. It is concluded that the spectroscopic constants determined for the cyclic and bent singlet isomers are the most accurate available, and it is hoped that these will be useful in the interpretation of high-resolution astronomical observations or laboratory experiments.

Inostroza, Natalia↗

Some critical questions about deterministic and stochastic adaptive control algorithms

The purpose of this informal paper is to discuss certain robustness issues associated with existing adaptive control algorithms. A modeling framework for incorporating high-frequency unknown dynamics in the adaptive control framework is suggested. Possible fundamental limitations of existing adaptive control framework is suggested. Possible fundamental limitations of existing adaptive control algorithms are also discussed, with emphasis upon their closed-loop stability properties in the presence of unmodeled high-frequency dynamics.

Athans, M.↗

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Vibrational Stabilization of Flexible Structures

It has been demonstrated that a high frequency excitation (HFE) field significantly changes the fundamental properties of mechanical systems. The most important contribution of HFE is the stiffening effect of an elastic continuum in the direction of the wave vector. This effect allows control of stiffness in any selected direction by the corresponding changes in the intensity of HFE. This new approach can be effective for large flexible space structures. Such an approach may prove to be very practical in the sense that large structures need to be made as flimsy as possible for low cost under ordinary situations. However, for certain operations such as development, orbital transfer, docking, and other circumstances, it would be vital to have a means of temporarily stiffening certain structural members. If the structure was designed to meet these occasional loads without temporary stiffening, it would be considerably more massive and more expensive.

Zak, M.↗

High-Accuracy Quartic Force Field Calculations for the Spectroscopic Constants and Vibrational Frequencies of 1(exp 1)A' l-C3H(-): A Possible Link to Lines Observed in the Horsehead Nebula PDR

It has been shown that rotational lines observed in the Horsehead nebula photon-dominated-region (PDR) are probably not caused by l-C3H+, as was originally suggested. In the search for viable alternative candidate carriers, quartic force fields are employed here to provide highly accurate rotational constants, as well as fundamental vibrational frequencies, for another candidate carrier: 1 (sup 1)A' C3H(−). The ab initio computed spectroscopic constants provided in this work are, compared to those necessary to define the observed lines, as accurate as the computed spectroscopic constants for many of the known interstellar anions. Additionally, the computed D-eff for C3H(−) is three times closer to the D deduced from the observed Horsehead nebula lines relative to l-C3H(+). As a result, 1 (sup 1)A' C3H(−). is a more viable candidate for these observed rotational transitions and would be the seventh confirmed interstellar anion detected within the past decade and the first C(sub n)H(−) molecular anion with an odd n.

Horsehead nebula↗

A modified pump laser system to pump the titanium sapphire laser

As a result of the wide tunability of the titanium sapphire laser NASA has sited it to be used to perform differential absorption lidar (DIAL) measurements of H2O vapor in the upper and lower troposphere. The titanium sapphire laser can provide a spectrally narrow (0.3 to 1.0 pm), high energy (0.5 to 1.0 J) output at 727, 762, and 940 nm which are needed in the DIAL experiments. This laser performance can be obtained by addressing the line-narrowing issues in a master oscillator and the high energy requirement in a fundamental mode oscillator. By injection seeding, the single frequency property of the master oscillator can produce a line narrow high energy power oscillator. A breadboard model of the titanium sapphire laser that will ultimately be used in NASA lidar atmospheric sensing experiment is being designed. The task was to identify and solve any problem that would arise in the actual laser system. One such problem was encountered in the pump laser system. The pump laser that is designed to pump both the master oscillator and power oscillator is a Nd:YLF laser. Nd:YLF exhibits a number of properties which renders this material an attractive option to be used in the laser system. The Nd:YLF crystal is effectively athermal; it produces essentially no thermal lensing and thermally induced birefringence is generally insignificant in comparison to the material birefringence resulting from the uniaxial crystal structure. However, in application repeated fracturing of these laser rods was experience. Because Nd:YLF rods are not commercially available at the sizes needed for this application a modified pump laser system to replace the Nd:YLF laser rod was designed to include the more durable Nd:YAG laser rods. In this design, compensation for the thermal lensing effect that is introduced because of the Nd:YAG laser rods is included.

Petway, Larry B.↗

Acoustic Observations of the OSIRIS-REx Sample Return Capsule Re-Entry from Wendover Airport

The Origins, Spectral Interpretation, Resource Identification, and Security‐Regolith Explorer sample return capsule (SRC) re‐entered the Earth’s atmosphere at hypersonic speeds from interplanetary space on 24 September 2023. The current work reports on 18 ground‐based acoustic sensors deployed at Wendover Airport, the same location that the Genesis and Stardust SRC re‐entries were recorded. Four different sensors (Chaparral Physics, Gem, Wilson Engineering Research and Development [WERD], and RedVox) were deployed in close proximity to compare their performance. All the sensors captured an N‐wave signal associated with the SRC re‐entry shock wave followed by a broadband coda. The Chaparral Physics array served as the high‐fidelity reference measurement. The N‐wave signal had a peak‐to‐peak amplitude of 4.07 Pa with a fundamental frequency of 4.98 Hz from 167.5° measured clockwise from north, nearly perpendicular to the SRC trajectory. In addition, high coherence in the coda was shown to be associated reflections from the surrounding mountains. In general, the more economical sensors (Gem, WERD, and RedVox) produced results that were consistent with these observations and sensor specifications. Beamforming with these single sensors arranged as an array showed agreement with the high‐fidelity array to within a couple of degrees. Furthermore, the current high‐fidelity results were compared with the measurements during the Genesis and Stardust SRC re‐entries. All three entries produced a broadband fundamental peak at a frequency that was inversely related to the SRC diameter as well as evidence of reflections from the surrounding topography.

KC, Real J. [Oklahoma State University, Stillwater↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Acoustic Wind Tunnel Measurements of a Quadcopter in Hover and Forward Flight Conditions

An experimental testing campaign was conducted in the NASA Langley Low Speed Aeroacoustic Wind Tunnel (LSAWT) in order to better understand the acoustic characteristics of a representative quadcopter system in both hover and forward flight conditions. Aerodynamic performance measurements were acquired using a multi-axis load cell to trim the vehicle to desired thrust/lift conditions. Hover acoustic measurements provide evidence of prominent rotor-airframe interaction noise that manifests in the form of high-amplitude harmonics of the fundamental rotor blade passage frequency. Forward flight acoustic measurements of simultaneous rotor operations indicate the presence of strong forward-aft rotor wake interactions that yield increased broadband noise levels relative to cases of individual rotor operation. These results indicate the potential need for modeling complex noise generation mechanisms associated with multirotor and rotor-airframe interactions for vehicles of this class.

Zawodny, Nikolas S.↗

Coherent frequency combs from electrons colliding with a laser pulse

Highly coherent and powerful light sources capable of generating soft x-ray frequency combs are essential for high precision measurements and rigorous tests of fundamental physics. In this work, we derive the analytical conditions required for the emission of coherent radiation from an electron beam colliding with a laser pulse, modeled as a plane wave. These conditions are applied in a series of numerical simulations, where we show that a soft x-ray frequency comb can be produced if the electrons are regularly-spaced and sufficiently monoenergetic. High quality beams of this kind may be produced in the near future from laser-plasma interactions or linear accelerators. Furthermore, we highlight the advantageous role of employing few-cycle laser pulses in relaxing the stringent monoenergeticity requirements for coherent emission. The conditions derived here can also be used to optimize coherent emission in other frequency ranges, such as the terahertz domain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗