Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high frequency testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modal survey tests for high-frequency vibration analysis of the Space Shuttle Main Engine

Variations in the modal characteristics of different Space Shuttle Main Engines (SSMEs) are presented herein to study their structural dynamics vibrations, especially under fluid/structure interaction. The results of extensive modal survey tests and analysis relative to significant features in the modal characteristics of different powerheads and components are discussed.

Panossian, H. V.↗

Small-sized specimen design with the provision for high-frequency bending-fatigue testing

The testing and study of emerging materials—such as additively manufactured materials—demands for specimen designs that are cost effective and time saving. Here the design of a small-sized bending-fatigue test specimen for an ultrasonic fatigue testing system is reported in this paper. The design is optimized based on the finite element analysis and analytical-solution results to achieve the proper vibration shape and stress distribution. The proposed design is evaluated in the high- and very-high-cycle fatigue regimes under 20-kHz frequency. Both simulation and testing results confirm that the desirable vibration mode occurs and the specimen fails at the designated test (gauge) section, where the maximum stress exists. The stress–life (S–N) curve is obtained for Inconel alloy 718 and indicates an expected trend.

36 MATERIALS SCIENCE↗

Variable frequency response testbed to validate protective relays up to 20 kHz☆

Microgrids operate in islanding or utility grid mode. In islanding mode, distributed energy sources with power electronics inverters can generate fault currents over a wide range of frequencies. To gain a better understanding of the nature of these events, it is crucial to measure currents at frequencies of up to 20 kHz at transient states with protective relays. Protective relays at these frequency responses should be tested prior to being installed in microgrids. However, testing at high-frequency currents cannot be done with Relay Test Equipment (RTE) that generate signals up to 50th Harmonic for 60 Hz (3 kHz). In this study, a frequency response method and testbed for high-frequency currents of up to 20.16 kHz was developed and tested. The testbed utilized a RTE and High-Frequency Power Source/ Amplifier. Furthermore, frequency relay experiments were run at frequencies of up to 1 and 20.16 kHz at a current magnitude of 0.1 and 0.5 A, respectively. The events were collected, and the current magnitude and frequency were plotted at time and frequency domain, respectively. The study of current magnitude and frequencies of up to 20.16 kHz for two overcurrent relays was performed and validated the variable frequency testbed and methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Development of Test Facilities for Induced, High-Frequency Plasma Instabilities

We present results from modifications to test facilities equipped with a plasma source capable of producing a LEO-type environment. The modifications impose an oscillation to the output, thus simulating ionospheric disturbance. The frequency of the oscillations is adjustable as well as the base-line output of the source. Test results indicate that the density of the plasma can be varied with minimal impact on other plasma properties such as electron temperature. It is, therefore, possible to simulate realistic plasma environments such as day/night transitions or localized turbulence. The modified source is an effective tool for testing space instruments in a relevant environment increasing the instruments technology readiness level.

McTernan, Jesse K.↗

The Development of Test Facilities for Induced, High-Frequency Plasma Instabilities

We present results from modifications to test facilities equipped with a plasma source capable of producing a LEO–type environment. The modifications impose an oscillation to the output, thus simulating ionospheric disturbance. The frequency of the oscillations is adjustable as well as the base-line output of the source.

McTernan, Jesse K.↗

Online Monitoring of Medium Voltage Cable Systems with Spread Spectrum Time Domain and Frequency Domain Reflectometry

In-service failures of wave energy convertor (WEC) cable systems can have a significant cost and power availability impact. Close parallel research 2019 data showed > 1B£ and 9 Terra-Watt-Hours associated with global off-shore wind (OSW) cable failures (Strang-Moran 2020). OSW is a closely related technology but currently is significantly cheaper than WEC technology. For wave energy to compete, the problem of reliable cable transmission must be mitigated. This project develops isolation technology to allow online high frequency reflectometry testing of medium voltage cables (1 to 10 kV and higher) without arcing or damage to the test instrument. Online spread spectrum time domain reflectometry (SSTDR) testing has been established for low voltage cable systems in the aircraft and rail industry and the ability to detect and locate cable flaws of interest is well understood. Extending reflectometry testing to medium voltage systems could enable detection of cable damage before failures occur thereby allowing repair and replacement of damaged cable segments to be scheduled and managed. The seedling project succeeded to pass and receive high frequency SSTDR signals onto a cable up to 1 kV using a parallel trace isolation circuit board that can be connected onto the test cable. The approach used a novel circuit design for which an invention disclosure has been filed. A proposed sapling project would extend the technology toward the higher operating voltages used by WEC systems, thereby enabling online SSTDR cable monitoring. The goal of the seedling project was to extend the capability of the ARENA cable/motor test bed to address medium voltages and to develop a high pass filter isolation architecture to protect the reflectometry instrument from the low frequency (DC – 60 Hz) line voltage while allowing the high frequency diagnostic signal to pass to and from the test instrument to the live line. Initial efforts focused on passive LCR filter circuits to reduce 60 Hz levels below 10 volts from a 10 kV line while allowing the MHz high frequency chirps to pass onto the cables and for mV signals to be detected. We discovered that the parasitic loss behavior of real high voltage components precluded this approach from working. An alternate approach was adapted for the electric field to couple between two parallel traces on a printed circuit board much like a radio-frequency coupler. The challenge here was and is to have the parallel traces close enough to each other to effectively pass the high frequency chirp onto the live line and receive any reflected signal from any encountered impedance change along the cable. This reflected signal will be in the mV range. The traces however must be far enough apart to not allow arcing on the board. A design with 3 mm spacing was determined to allow the high frequency signal to pass onto the live line and receive the mV signal back into the instrument while reducing the 60 Hz voltage amplitude by >80 dB (more than a factor of 10,000) without allowing arcing from across the parallel traces. This was confirmed by simulation and test.

16 TIDAL AND WAVE POWER↗

Study of high performance alloy electroforming

More panels electroformed with intentional variations of pulse plating parameters are being made. Pulse plating frequency was noted to have a significant effect regarding mechanical properties. The use of a high pulse frequency (assuming fixed duty cycles) results in an increase in ductility and a decrease in ultimate and yield strengths. Electroforming to intermediate frequencies is being done to obtain the best possible combination of ductility and strength. Results of some tests from high frequency specimens are tabulated.

Malone, G. A.↗

Identification and detection of anomalies through SSME data analysis

The goal of the ongoing research described in this paper is to analyze real-time ground test data in order to identify patterns associated with the anomalous engine behavior, and on the basis of this analysis to develop an expert system which detects anomalous engine behavior in the early stages of fault development. A prototype of the expert system has been developed and tested on the high frequency data of two SSME tests, namely Test #901-0516 and Test #904-044. The comparison of our results with the post-test analyses indicates that the expert system detected the presence of the anomalies in a significantly early stage of fault development.

Pereira, Lisa↗

The phototron: A light to RF energy conversion device

The phototron, a photoelectric device that converts light to radio frequency energy, is described. It is a vacuum tube, free electron, device that is mechanically similar to a reflex klystron with the hot filament cathode replaced by a large area photocathode. The device can operate either with an external voltage source used to accelerate the photoelectrons or with zero bias voltage; in which case the photokinetic energy of the electrons sustains the R.F. oscillations in the tuned R.F. circuit. One basic design of the phototron was tested. Frequencies as high as about 1 GHz and an overall efficiency of about 1% in the biased mode were obtained. In the unbiased mode, the frequencies of operation and efficiences are considerably lower. Success with test model suggests that considerable improvements are possible through design refinements. One such design refinement is the reduction of the length of the electron flight path.

Freeman, J. W.↗

Reducing the Effect of Transducer Mount Induced Noise on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

Flight vehicle aeroacoustic environments induced during transonic and supersonic flight are usually predicted by subscale wind tunnel testing utilizing high frequency miniature pressure transducers. In order to minimize noise induced by the measurement itself, transducer flush mounting with the model surface is very important. The National Aeronautics and Space Administration (NASA) has accomplished flushness in recent testing campaigns via use of a transducer holder that can be machined and sanded. A single hole in the holder allows the flow medium to interact with the transducer diaphragm. Noise is induced by the resulting cavity however, and is a challenge to remove in post-processing. A new holder design has been developed that minimizes the effects of this transducer mount induced noise (XMIN) by reducing the resonance amplitude or increasing its resonance frequency beyond the range of interest. This paper describes a test conducted at the NASA/George C. Marshall Space Flight Center Trisonic Wind Tunnel intended to verify the effectiveness of this design. The results from this test show that this new transducer holder design does significantly reduce the influence of XMIN on measured fluctuating pressure levels without degrading a transducer's ability to accurately measure the noise external to the model.

Herron, Andrew J.↗

Offshore Wind to Hydrogen - Modeling, Analysis, Testing and International Collaboration Work

This project explores electrolytic hydrogen production from an offshore wind turbine by: Modeling: Simulate an offshore wind turbine and generate power output profiles; Analysis: Analyze offshore conditions and determine operational modes of the stack; Testing: Perform hardware testing to evaluate dynamic characteristics; and International Collaboration Work: Share learnings and publish. Potential Outcomes: Accelerate development of an integrated, in-turbine offshore wind hydrogen system; and Support two DOE Energy Earthshots - Hydrogen and Floating Offshore Wind.

electrolyzer↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Control of Combustion-Instabilities Through Various Passive Devices

Results of a computational study on the effectiveness of various passive devices for the control of combustion instabilities are presented. An axi-symmetric combustion chamber is considered. The passive control devices investigated are, baffles, Helmholtz resonators and quarter-waves. The results show that a Helmholtz resonator with a smooth orifice achieves the best control results, while a baffle is the least effective for the frequency tested. At high sound pressure levels, the Helmholtz resonator is less effective. It is also found that for a quarter wave, the smoothness of the orifice has the opposite effect than the Helmholtz resonator, i.e. results in less control.

Frendi, Abdelkader↗