Heterodyne Doppler 1-micron lidar measurement of reduced effective telescope aperture due to atmospheric turbulence

A pulsed Nd:YAG bistatic focused-beam lidar allowing simultaneous heterodyne and direct detection of the same lidar returns has been experimentally employed to ascertain the effect of atmospheric turbulence on heterodyne and direct-detection lidar at 1 micron, by measuring the average carrier-to-noise ratio and statistical fluctuation level in the return signals under various experimental and atmospheric conditions. Atmospheric turbulence is found capable of reducing the lidar receiver's effective telescope aperture and heterodyne detection efficiency. This observed effective-aperture limitation functionally resembles predictions based on the Clifford and Wandzura (1981) heterodyne wavefront detection theory.

Chan, Kin Pui↗

Heterodyne efficiency for a coherent laser radar with diffuse or aerosol targets

The performance of a Coherent Laser Radar is determined by the statistics of the coherent Doppler signal. The heterodyne efficiency is an excellent indication of performance because it is an absolute measure of beam alignment and is independent of the transmitter power, the target backscatter coefficient, the atmospheric attenuation, and the detector quantum efficiency and gain. The theoretical calculation of heterodyne efficiency for an optimal monostatic lidar with a circular aperture and Gaussian transmit laser is presented including beam misalignment in the far-field and near-field regimes. The statistical behavior of estimates of the heterodyne efficiency using a calibration hard target are considered. For space based applications, a biased estimate of heterodyne efficiency is proposed that removes the variability due to the random surface return but retains the sensitivity to misalignment. Physical insight is provided by simulation of the fields on the detector surface. The required detector calibration is also discussed.

Frehlich, R. G.↗

Laser Metrology Heterodyne Phase-Locked Loop

A method reduces sensitivity to noise in a signal from a laser heterodyne interferometer. The phase-locked loop (PLL) removes glitches that occur in a zero-crossing detector s output [that can happen if the signal-to-noise ratio (SNR) of the heterodyne signal is low] by the use of an internal oscillator that produces a square-wave signal at a frequency that is inherently close to the heterodyne frequency. It also contains phase-locking circuits that lock the phase of the oscillator to the output of the zero-crossing detector. Because the PLL output is an oscillator signal, it is glitch-free. This enables the ability to make accurate phase measurements in spite of low SNR, creates an immunity to phase error caused by shifts in the heterodyne frequency (i.e. if the target moves causing Doppler shift), and maintains a valid phase even when the signal drops out for brief periods of time, such as when the laser is blocked by a stray object.

Loya, Frank↗

Modified Phasemeter for a Heterodyne Laser Interferometer

Modifications have been made in the design of instruments of the type described in "Digital Averaging Phasemeter for Heterodyne Interferometry". A phasemeter of this type measures the difference between the phases of the unknown and reference heterodyne signals in a heterodyne laser interferometer. The phasemeter design lacked immunity to drift of the heterodyne frequency, was bandwidth-limited by computer bus architectures then in use, and was resolution-limited by the nature of field-programmable gate arrays (FPGAs) then available. The modifications have overcome these limitations and have afforded additional improvements in accuracy, speed, and modularity. The modifications are summarized.

Loya, Frank M.↗

Digital Averaging Phasemeter for Heterodyne Interferometry

A digital averaging phasemeter has been built for measuring the difference between the phases of the unknown and reference heterodyne signals in a heterodyne laser interferometer. This phasemeter performs well enough to enable interferometric measurements of distance with accuracy of the order of 100 pm and with the ability to track distance as it changes at a speed of as much as 50 cm/s. This phasemeter is unique in that it is a single, integral system capable of performing three major functions that, heretofore, have been performed by separate systems: (1) measurement of the fractional-cycle phase difference, (2) counting of multiple cycles of phase change, and (3) averaging of phase measurements over multiple cycles for improved resolution. This phasemeter also offers the advantage of making repeated measurements at a high rate: the phase is measured on every heterodyne cycle. Thus, for example, in measuring the relative phase of two signals having a heterodyne frequency of 10 kHz, the phasemeter would accumulate 10,000 measurements per second. At this high measurement rate, an accurate average phase determination can be made more quickly than is possible at a lower rate.

Johnson, Donald↗

An All-Solid-State, Room-Temperature, Heterodyne Receiver for Atmospheric Spectroscopy at 1.2 THz

Heterodyne receivers at submillimeter wavelengths have played a major role in astrophysics as well as Earth and planetary remote sensing. All-solid-state heterodyne receivers using both MMIC (monolithic microwave integrated circuit) Schottky-diode-based LO (local oscillator) sources and mixers are uniquely suited for long-term planetary missions or Earth climate monitoring missions as they can operate for decades without the need for any active cryogenic cooling. However, the main concern in using Schottky-diode-based mixers at frequencies beyond 1 THz has been the lack of enough LO power to drive the devices because 1 to 3 mW are required to properly pump Schottky diode mixers. Recent progress in HEMT- (high-electron-mobility- transistor) based power amplifier technology, with output power levels in excess of 1 W recently demonstrated at W-band, as well as advances in MMIC Schottky diode circuit technology, have led to measured output powers up to 1.4 mW at 0.9 THz. Here the first room-temperature tunable, all-planar, Schottky-diode-based receiver is reported that is operating at 1.2 THz over a wide (≈20%) bandwidth. The receiver front-end (see figure) consists of a Schottky-diode-based 540 to 640 GHz multiplied LO chain (featuring a cascade of W-band power amplifiers providing around 120 to 180 mW at W-band), a 200-GHz MMIC frequency doubler, and a 600-GHz MMIC frequency tripler, plus a biasable 1.2-THz MMIC sub-harmonic Schottky-diode mixer. The LO chain has been designed, fabricated, and tested at JPL and provides around 1 to 1.5 mW at 540 o 640 GHz. The sub-harmonic mixer consists of two Schottky diodes on a thin GaAs membrane in an anti-parallel configuration. An integrated metal insulator metal (MIM) capacitor has been included on-chip to allow dc bias for the Schottky diodes. A bias voltage of around 0.5 V/diode is necessary to reduce the LO power required down to the 1 to 1.5 mW available from the LO chain. The epilayer thickness and doping profiles have been specifically optimized to maximize the mixer performance beyond 1 THz. The measured DSB noise temperatures and conversion losses of the receiver are 2,000 to 3,500 K and 12 to 14 dB, respectively, at 120 K, and 4,000 to 6,000 K and 13 to 15 dB, respectively, at 300 K. These results establish the state-of-the-art for all-solid-state, all-planar heterodyne receivers at 1.2 THz operating at either room temperature or using passive cooling only. Since no cryogenic cooling is needed, the receiver is eminently suited to atmospheric heterodyne spectroscopy of the outer planets and their moons.

Siles, Jose V.↗

Data Processing of Miniaturized Laser Heterodyne Radiometer (mini-LHR) Ground Instrument Retrievals

The Miniaturized Laser Heterodyne Radiometer (mini-LHR) is a passive ground instrument that observes the mole fraction of carbon dioxide (CO) and methane (CH)in the atmospheric column by measuring their absorption of sunlight at 1.6 microns. A laser heterodyne radiometer is similar in design to the super heterodyne radio receiver that is well known by ham radio enthusiasts. While not previously a commercial technique, laser heterodyne radiometers have a history of measuring atmospheric trace gases that started in the 1960s. With the commercial availability of inexpensive, low-power, thumbnail-sized lasers developed for the telecommunications industry, it was possible to miniaturize this technique and ultimately commercialize it. The mini-LHR has been under development at NASA GSFC since 2009. During that time, in addition to signicant technical improvements, processing has also evolved and been streamlined. Here we present details of the processing approach for raw mini-LHR data to produce 30- and 60-minute data products of CH and CO column mole fractions. Processing occurs in two general stages: a python-based pre-processing of raw data, followed by ingestion into a Planetary Spectrum Generator (PSG) retrieval algorithm. Raw data processing involves removal of outliers, correcting for changes in air mass throughout the day, averaging scans, and ultimately converting averaged scans into transmittance vs. wavelength. The PSG retrieval simulates a spectra for the time/day/location of the scan with meteorological inputs from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) data set and then perturbs the concentrations of CO and CH to obtain a t based on an iterative least-squares curve fitting procedure.

Giancarlo Roberto Zambrano↗

Sensitivity of an astronomical infrared heterodyne spectrometer

The factors determining the sensitivity of a real astronomical heterodyne spectrometer are described. The deviation from the ideal heterodyne system for line detection is described in terms of a series of degradation factors. A discussion of degradation due to a low local oscillator power and to line profile detection is presented. Representative values for the degradation factors are given. Even with a total degradation of not less than 30, the heterodyne spectrometer is still found to be a highly sensitive tool in IR astronomy.

Kostiuk, T.↗

Infrared heterodyne spectroscopy of atmospheric ozone

The absorption spectrum of atmospheric ozone is measured within a 1/cm region at 1100/cm, using an IR heterodyne detector (spectrometer with CO2 local oscillator) developed for astronomical work. Absorption spectra obtained by passing radiation from the tunable diode laser through an absorption cell, heterodyne spectra of atmospheric ozone, and a predicted atmospheric spectrum are compared. Water vapor absorbing in the region of interest (1100/cm) is also considered. Preliminary results encourage the use of diode laser local oscillators in tunable heterodyne detector systems for spectroscopy of atmospheric ozone and remote high-resolution spectroscopy of atmospheric constituents and pollutants.

Frerking, M. A.↗

The evaluation of a HgCdTe photomixer with a Tunable Diode Laser (TDL) and the evaluation of TDL's as a local oscillator in a heterodyne detection system

Heterodyne systems would be much more versatile if a broadly tunable laser, such as a semiconductor diode laser (TDL), could be used as the local oscillator (LO). Previous studies have shown that while a TDL can be used as an LO, the TDL lack sufficient power to cause the signal-to-noise ratio to be shot noise limited. The heterodyne system with a HgCdTe photodiode as the LO was characterized and the beat frequency response of the heterodyne systems was mapped out.

Harward, C. N.↗

Electronic heterodyne recording and processing of optical holograms using phase modulated reference waves

The use of a phase-modulated reference wave for the electronic heterodyne recording and processing of a hologram is described. Heterodyne recording is used to eliminate the self-interference terms of a hologram and to create a Leith-Upatnieks hologram with coaxial object and reference waves. Phase modulation is also shown to be the foundation of a multiple-view hologram system. When combined with hologram scale transformations, heterodyne recording is the key to general optical processing. Spatial filtering is treated as an example.

Decker, A. J.↗

Atmospheric monitoring using heterodyne detection techniques

Both passive and active remote-monitoring instruments using discretely tunable infrared gas lasers and heterodyne receivers have been used for measurements of ozone and other trace constituents in the atmosphere. A ground-based solar heterodyne radiometer has been used in discrete spectral regions near 9.5 microns to measure altitude profiles of ozone in both the troposphere and stratosphere. Results indicate that this technique shows promise in providing calibration points for earth-orbiting ozone-measurement instruments. An airborne laser absorption spectrometer has been used to measure tropospheric ozone in two series of flights during the winter and spring of 1977, and these operations are described. Plans are also in progress to fly a balloon-borne heterodyne radiometer during the fall of 1977 in order to measure stratospheric trace species.

Menzies, R. T.↗

Stratospheric sounding by infrared heterodyne spectroscopy

Intensity profiles of infrared spectral lines of stratospheric constituents can be fully resolved with a heterodyne spectrometer of sufficiently high resolution (approximately 5 MHz = 0.000167 kaysers at 10 microns). The constituents' vertical distributions can then be evaluated accurately by analytic inversion of the measured line profiles. Estimates of the detection sensitivity of a heterodyne receiver are given in terms of minimum detectable volume mixing ratios of stratospheric constituents, indicating a large number of minor constituents which can be studied. Stratospheric spectral line shapes and the resolution required to measure them are discussed in light of calculated synthetic line profiles for some stratospheric molecules in a model atmosphere. The inversion technique for evaluation of gas concentration profiles is briefly described, and applications to synthetic lines of O3, CO2, CH4, and N2O are given. Some recent heterodyne measurements of CO2 and O3 absorption lines are analytically inverted, and the vertical distributions of the two gases are determined.

Abbas, M. M.↗

Development and performance of a laser heterodyne spectrometer using tunable semiconductor lasers as local oscillators

A diode laser based IR heterodyne spectrometer for laboratory and field use was developed for high efficiency operation between 7.5 and 8.5 microns. The local oscillator is a PbSSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed cycle cooler. The laser output frequency is controlled and stabilized using a high precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. Single laser modes are selected by a grating placed in the local oscillator beam. The system employs reflecting optics throughout to minimize losses from internal reflection and absorption, and to eliminate chromatic effects. Spectral analysis of the diode laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the infrared spectral regions over which useful heterodyne operation can be achieved. System performance has been studied by making heterodyne measurements of etalon fringes and several Freon 13 (CF3Cl) absorption lines against a laboratory blackbody source. Preliminary field tests have also been performed using the Sun as a source.

Glenar, D.↗

Atmospheric solar absorption measurements in the 9-11 micron region using a diode laser heterodyne spectrometer

A tunable diode laser heterodyne radiometer was developed for ground based measurements of atmospheric solar absorption spectra in the 9 to 12 micron spectral range. The performance and operating characteristics of this tunable infrared heterodyne radiometer (TIHR) is discussed along with recently measured heterodyne solar absorption spectra in the 10 to 11 micron spectral region.

Harward, C. N.↗

Extending the operating temperature, wavelength and frequency response of HgCdTe heterodyne detectors

Near ideal optical heterodyne performance was obtained at GHz IF frequencies in the 10 micrometer wavelength region with liquid nitrogen cooled HgCdTe photodiodes. Heterodyne NEP's as low as 2.7 x 10 to the minus 20th power W/Hz at 100MHz, 5.4 x 10 to the minus 20th power W/Hz at 1.5 GHz, and 9.4 x 19 to the minus 20th power W/Hz at 3 GHz were achieved. Various physical phenomena which occur within a photodiode and affect heterodyne operation were examined in order to assess the feasibility of extending the operating temperature, wavelength, and frequency response of these HgCdTe photomixers.

Spears, D. L.↗

Far infrared heterodyne systems

Three far infrared detectors, the InSb hot electron bolometer, the GaAs Schottky diode and the Josephson point contact junction, were incorporated as mixers into sensitive heterodyne systems. The performances of existing heterodyne receivers/radiometers using these detectors are described and compared. Other applications of submillimeter heterodyne techniques are discussed.

Tannenwald, P. E.↗

Electronic heterodyne recording of interference patterns

An electronic heterodyne technique is being investigated for video (i.e., television rate and format) recording of interference patterns. In the heterodyne technique electro-optic modulation is used to introduce a sinusoidal phase shift between the beams of an interferometer. For phase modulation frequencies between 0.1 and 15 MHz an image dissector camera may be used to scan the resulting temporally modulated interference pattern. Heterodyne detection of the camera output is used to selectively record the interference pattern. An advantage of such synchronous recording is that it permits recording of low-contrast fringes in high ambient light conditions. The application of this technique to the recording of holograms is discussed.

Merat, F. L.↗