Prospect for cislunar spacecraft and near-earth asteroid detection using heliostat fields at night
this manuscript for SPIE Optics + Photonics 2024 is based on SAND2023-13117R previously published as unclassified unlimited release
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
this manuscript for SPIE Optics + Photonics 2024 is based on SAND2023-13117R previously published as unclassified unlimited release
SolarPILOT is a software package that generates heliostat field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. SolarPILOT was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL's System Advisor Model (SAM) in a simplified format. Prior means for user interaction with SolarPILOT have included the application's graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called "LK." This paper presents a new, full-featured Python-based application programmable interface (API) for SolarPILOT, which we hereafter refer to as CoPylot. CoPylot provides access to all SolarPILOT's capabilities to generate and characterize power tower CSP systems seamlessly through Python. Supported capabilities include (i) creating and destroying a model instances with message reporting tools; (ii) accessing and setting any SolarPILOT variable including custom land boundaries for field layout; (iii) programmatically managing receiver and heliostat objects with varied attributes for systems with multiple receiver or heliostat types; (iv) generating, assigning, and modifying heliostat field layouts including the ability to set individual heliostat locations, aimpoints, soiling rates, and reflectivity levels; (v) simulating heliostat field performance; (vi) returning detailed results describing performance of individual heliostats, the aggregate field, and receiver flux; and, (vii) exporting Python-based model instances to multiple file formats. CoPylot enables Python users to perform detailed tower CSP analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. In addition to CoPylot's functionality, Python users have access to the over 100,000 open-source libraries to develop, analyze, optimize, and visualize CSP tower research.
Concentrating Solar Power (CSP) tower systems use heliostat fields to direct solar energy to a central receiver. The efficiency of the heliostat field is crucial for achieving thermal generation targets and is also the largest cost component, making up 30-40% of total project costs. Developers face a tradeoff: reducing heliostat costs may decrease optical performance and increase land use, while improving performance could raise manufacturing costs (through higher precision). The optimal design depends on land, labor, and manufacturing costs. Additionally, inherent performance limitations exist - optical errors result in larger solar images as heliostats move farther from the receiver, increasing spillage and attenuation losses. Ultimately, there exists a point where receiver design power can no longer be achieved at design conditions for a given solar field area. This point depends on key heliostat field design parameters including field layout, heliostats size, focus method, and heliostat optical error. In this work, we explore and characterize the performance trade-offs between heliostat size, focus method, and optical error using Monte Carlo ray-tracing simulations using NREL's high performance computing resources. The goal of this fundamental investigation is to understand practical heliostat design performance impacts that can be used to produce more cost-effective heliostat fields while still achieving plant thermal generation targets.
This work demonstrates methods of mapping high-spatial-resolution direct normal irradiance (DNI) data from satellites, Total Sky Imagers (TSIs), and analogous data sources onto a heliostat field for characterizing the spatial and temporal variation of the incident flux on a central receiver tower during cloud transient events. The mapping methods are incorporated into an optical software module that interfaces with CoPylot–SolarPILOT’s python API– to provide computationally efficient optical simulation of the heliostat field and the solar power tower. Eventually, this optical model will be incorporated into optimization models whereby a plant operator can understand the effects of cloud transient events on overall power production and receiver lifetime due to creep-fatigue damage and therefore make better informed decisions about receiver shutdown events. By more accurately modelling the effects of cloud events on receiver flux maps, this work may determine the magnitude and frequency of thermal cycling on receiver tubes and panels using actual or realistic cloud shapes instead of averaged DNI values–which may undercount the total cycle number. This work may also prevent unnecessary plant shutdowns due to overly precautionary control strategies and characterize the relative impact of various cloud types on receiver life. We plan to eventually integrate this methodology into the System Advisor Model (SAM) to improve performance model accuracy during periods of cloudiness. In this paper, we demonstrate generating DNI maps and mapping them to a solar field in CoPylot using 10 m resolution data from publicly available Sentinel-2 satellite data over the Crescent Dunes plant.
Heliostat fields are one of the main components of a concentrated solar thermal plant. As GEN3 technology has been developed at pilot plant level targeting higher temperatures >700C, having a precise Heliostat field control system will enable the success of the GEN3 technology. Heliogen Inc. has developed the next generation of control systems for heliostat fields. Their early development was on single facet heliostats at their R&D facility in Lancaster, California. This new system allows for a closed loop integration to a current open loop setup of a regular Heliostat control system. Sandia National Laboratories and Heliogen Inc. have partnered together to test Heliogen’ s innovative new SOHOT system at the National Solar Thermal Test Facility.
This project has sought to develop new uses for surveying-quality Light Detecting and Ranging (LiDAR) 3D scanning sensors in the automatic/autonomous assessment of optical errors in largescale concentrating solar power heliostat fields. Past experiments have demonstrated the ability of a 3D-LiDAR to acquire highly accurate point cloud measurements across several Sandia NSTTF heliostats. The goal of this project is to expand upon this work to see if and how it can be used in large commercial heliostat fields.
Falling particle receivers are an emerging technology for use in concentrating solar power systems. In this paper, quartz half-shells are investigated for use as full or partial aperture covers to reduce receiver thermal losses. Quartz half-shell aperture covers offer the ability to minimally interfere with incoming solar radiation from the heliostat field while obstructing thermal radiation and advection from leaving the receiver cavity. The fluid dynamics and heat transfer of a receiver subdomain and surrounding air are modeled using ANSYS®FLUENT We compare the percentage of total incident solar power lost due to conduction through the receiver walls, advective losses through the aperture, and radiation exiting the aperture. Contrary to expected outcomes, results show that quartz aperture covers can increase radiative losses and result in modest to nonexistent reductions in advective losses. The increased radiative losses are driven by elevated quartz half-shell temperatures and have the potential to be mitigated by active cooling and/or material selection. Quartz half-shell total transmissivity was measured experimentally using a radiometer and the National Solar Thermal Test Facility heliostat field with values up to 0.97 ± 0.01. Quartz half-shell aperture covers did not yield expected efficiency gains in numerical results due to increased radiative losses, but efficiency improvement in some numerical results and the performance of quartz half-shells subject to concentrated solar radiation suggest that quartz half-shell aperture covers should be investigated further.
Since its establishment, the Heliostat Consortium (HelioCon) has made substantial progress toward closing many of the gaps in concentrating solar power (CSP) research. Numerous techno-economic studies have been performed, investigating topics ranging from the trade-off between size and temperature for industrial process heat applications to optimization of the heliostat design itself for various applications. Significant improvements have been made in optical metrology techniques, with first steps toward in situ measurement of heliostat fields. Several standards have been, and continue to be, developed with the coordination of an international group of CSP industry participants. Training programs have been developed, with universities including CSP in their engineering curricula, and many public webinars have been held to provide broad access to the latest CSP research. Improved CSP components such as mirror facets and wireless communication systems have been developed, and the solar tower at Sandia National Laboratories has been upgraded with a testbed for closed-loop controls research and development. Field deployment challenges involving heliostat foundations and sensitive wildlife habitats have been explored, with progress made toward methods for streamlining project development and permitting. Additional knowledge has been added to the body of work on wind behavior of heliostats and arrays of heliostats, with progress made toward a holistic understanding of wind design methods. Finally, techniques have been developed and demonstrated for assessing soiling conditions at a proposed project site, with predictive models for the soiling rate showing good results. Taking these results together, HelioCon has contributed greatly to the global CSP research and development effort over the past several years.
Explore the source record for details and available documents.
Our motivation is to develop more efficient heliostats that can provide commercially viable solar thermal power at temperatures > 800°C. Such high temperatures will enable high-temperature industrial processes, as well as electrical generation after sunset with high efficiency. The importance of this research is that such heliostats have the potential to substantially expand the global use of solar energy, by adding solar thermal power as a major component. Thermal solar currently accounts for only 1% of all solar power (with PV being the rest), with heliostat fields providing just 0.25%. Our goals have been 1) to demonstrate a technical improvement for heliostats that can enable fields of them to more efficiently power receivers and reactors, and 2) to show a path to low-cost mass production. Our solution uses new opto-mechanical technology to correct a fundamental deficiency of present heliostats that limits their concentration, namely that they have fixed shape. Most of today’s heliostat research does not address this, but is directed simply toward cost reduction in an effort to make heliostats commercially viable. We are motivated to explore also improving heliostat efficiency, which can be done by continually changing their shape to maximize the concentration of sunlight throughout the day. This is not a new concept, but it has never been implemented in a practical, cost-effective way that approaches the theoretical limit to concentration while also improving mechanical performance; this is our goal. Our major accomplishments have been: 1) We have realized the planned design, construction, and test of a prototype heliostat that achieves the required shape changes in an 8 m2 single-piece glass mirror. The mirror is attached to a steel support frame that is automatically mechanically twisted by the heliostat drives that orient the mirror to direct sunlight to the tower-mounted receiver. Closed-loop tracking is done using a new beamsplitter camera that exploits the target-oriented mount configuration. Field tests of the heliostat show that the light is reflected through the day to always form a disc image of the sun, as needed to obtain the highest concentration. 2) We have developed the design for a field of 431 heliostats to deliver annual average of 1 MW of thermal power at 3,000 sun concentration, matched to a high-temperature ≥ 1000°C chemical reactor. 3) We have also developed, beyond the original stated goals of the project, a new concept for closed-loop tracking and shape-sensing for all the heliostats in the above field, using just 6 cameras around the concentrated reactor focus. Our research adds to the understanding of solar thermal energy by its demonstration of the technical effectiveness of a higher performing heliostat, and by its concept for a new powerful method for real-time tracking and shape sensing in the field, as described above. We have studied the economic feasibility of fields of our twisting heliostats to provide high- temperature heat at a price competitive with that of burning gas, to satisfy the DOE’s studied zero-emissions scenario, where the gas price has to include the cost of carbon capture. The project has the potential to greatly benefit the public if it helps limit global warming by 1) reducing carbon emission from industrial heating, which is currently a major contributor to the 40-billion-ton annual increase in atmospheric CO 2 . 2) Ultimately, the technology could prove to be the least expensive method to power direct air capture of CO 2 on the very large scale needed to remove the 1 trillion-ton excess of CO 2 already in the atmosphere.
Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.
Next-generation concentrating solar power concepts currently being developed under the U.S. Department of Energy's Gen3 program include several novel heliostat field and receiver arrangements. Among these concepts are solar fields utilizing multiple receivers or several distinct receiver flux control zones, and each of which has particular power or peak flux constraints. In this paper, we present a linear program that identifies optimal heliostat-to-receiver assignment strategies for multi-receiver or multi-zone solar fields based on detailed calculations made by an optics modeling package. Two distinct problems are addressed: namely, (1) a design problem that chooses the optimal set of heliostats to include in a final layout given receiver constraints and performance, and (2) an operations problem that assigns existing heliostats to a receiver, maximizing field power output while maintaining receiver power constraints. The optimization methodology is integrated into the concentrating solar power tower modeling package SolarPILOTTM, and results are presented showing that heliostat assignment strategies can impact both initial heliostat field layout characteristics and the cost of thermal energy produced by the field. The methodology succeeds in maintaining power requirements but at the expense of producing different flux profiles on each receiver surface. Consequently, the paper also discusses additional measures that are applied to ensure that desirable flux distribution properties are maintained, reducing local flux mean-absolute-deviation values from a baseline of 17% or greater to less than 5% compared to a desired reference flux profile.
No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.
The present disclosure describes non-intrusive optical (NIO) characterization methods which efficiency measures optical errors (such as mirror surface slope error, mirror canting error, and heliostat tracking error) of a heliostat field. The methods utilize photogrammetry and deflectometry to analyze an image taken of a heliostat to determine optical errors and increase the amount of solar energy delivered by the heliostat to the receiver.
Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.
This report describes an initial investigation into a proposed solution to the important problem of performing a detailed evaluation of heliostat optical performance, in situ in a heliostat field. Our approach is to place digital cameras in a position near the receiver where they look back toward the heliostat mirrors. The pixels of each camera sensor identify a set of small cells on the mirror surface, each corresponding to a “mixel.” By either passing reflected sunbeam over the camera or passing the camera through the reflected sunbeam, the cameras intercept sunlight reflected from each mixel. We then analyze the recorded video data to determine times when each mixel transitions from dark to light, and then back to dark. We then use these transitions to construct vectors from the camera to the mixel, and then from the mixel to the edge of the Sun at that moment. We then compute the surface normal at the mixel, which bisects the angle between these vectors. Performing this analysis for all mixels in the mirror yields a high-resolution map of slope across the mirror surface. We have implemented most of this process, successfully collecting data for an example heliostat facet and computing a preliminary estimated slope map. However, more work remains to complete this calculation, since certain factors and transformations are not yet included. Our observations so far support our hypothesis that such a system is possible, but we have not yet completed our quantitative evaluation of the concept.
The NSTTF O&M Project continues the operation and maintenance activities of the existing critical capabilities and infrastructure at the NSTTF. This project is to support and assure the success of Solar Heat for Industrial Process in the United States and the larger global community by ensuring the NSTTF is a safe and operational facility. The primary goal of this project will be to maintain the solar tower and heliostat field while also allowing NSTTF staff to improve processes for operations and maintenance. This includes expanding our preventative maintenance program, inventory systems, and our data sharing capabilities. Additionally, this will support an outreach program with regular seminars, sharing of data, and the release of open-source software to support heliostat metrology
The Heliostat Consortium (HelioCon) was launched in 2021 to advance heliostat technology. One of its first efforts was to do a detailed analysis of gaps in technology and capabilities in the heliostat industry and complete a roadmap study describing high-priority gaps. HelioCon gathered gaps through a series of outreach activities with representatives and experts from industries and research institutes. Here, this paper discusses the gap analysis for the techno-economic analysis (TEA) topic. One of the main objectives of the TEA topic is to relate the cost and performance of heliostats and heliostat components to the overall system performance. In this study, we limit the scope of this topic to the heliostat field, tower, and receiver and do not consider downstream applications or uses of thermal energy. We conducted a thorough review of existing models and compiled a list of the state of the art in open-source tools currently available to researchers. We collected an initial list of gaps for the TEA of heliostats from industry developers and experts. Each gap is briefly described, and the heliostat development cycle stages that the gap impacts are indicated. We ranked the initial list of TEA gaps into tiers depending on their potential impact. For TEA, most of the gaps identified are related to developing models or data. Strictly speaking, none of these gaps are essential for heliostat development, but all would aid in the heliostat development process.