Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating and cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY↗

Modeling District Heating and Cooling Systems with URBANopt, GeoJSON to Modelica Translator, and the Modelica Buildings Library

The URBANopt project has successfully leveraged OpenStudio/EnergyPlus to model buildings and electrical systems at an urban scale; however, URBANopt has lacked the ability to model district thermal energy systems until recently. This paper will present the modeling infrastructure that was developed specifically for the analysis of district heating and cooling systems, and how it is integrated into the existing URBANopt framework. The paper also discusses the development of new models added to the Modelica Buildings Library to model various district energy system components including loads, energy transfer stations (ETS), distribution networks, and central plants. The paper describes how different building loads can be modeled including time series, TEASER reduced-order models, or Spawn of EnergyPlus models. URBANopt District Energy Systems allows the user to switch between the various configurations.

district heating and cooling↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Consumer Guide to Home Heating and Cooling

Learn about types of heating and cooling systems, system maintenance, and best practices for saving energy with your heating and cooling. This fact sheet from Energy Saver also includes information on buying a new heating or cooling system; efficiency ratings; and selecting new systems including air conditioners, heat pumps, and furnaces.

heating, cooling, air conditioners, heat pumps, fu↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Can Cooling and Heating Functions Be Modeled with Homogeneous Radiation Fields?

Abstract Cooling and heating functions describe how radiative processes impact the thermal state of a gas as a function of its temperature and other physical properties. In a most general case the functions depend on the detailed distributions of ionic species and on the radiation spectrum. Hence, these functions may vary on a very wide range of spatial and temporal scales. In this paper, we explore cooling and heating functions between 5 ≤ z ≤ 10 in simulated galaxies from the Cosmic Reionization On Computers project. We compare three functions: (1) the actual cooling and heating rates of hydrodynamic cells as a function of cell temperature, (2) the median cooling and heating functions computed using median interstellar medium (ISM) properties (median ISM), and (3) the median of the cooling and heating functions of all gas cells (instantaneous). We find that the median ISM and instantaneous approaches to finding a median cooling and heating function give identical results within the spread due to cell-to-cell variation. However, the actual cooling (heating) rates experienced by the gas at different temperatures in the simulations do not correspond to either summarized cooling (heating) functions. In other words, the thermodynamics of the gas in the simulations cannot be described by a single set of a cooling plus a heating function with a spatially constant radiation field that could be computed with common tools, such as CLOUDY.

79 ASTRONOMY AND ASTROPHYSICS↗

Mobile heat pipe cooled fast reactor system

A mobile heat pipe cooled fast nuclear reactor may be configured for transportation to remote locations and may be able to provide 0.5 to 2 megawatts of power. The mobile heat pipe cooled fast reactor may contain a plurality of heat pipes that are proximate to a plurality of fuel pins inside the reactor. The plurality of heat pipes may extend out of the reactor. The reactor may be configured to be placed in a standard shipping container, and may further be configured to be contained within a cask and attached to a skid for easier transportation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mobile heat pipe cooled fast reactor system

A mobile heat pipe cooled fast nuclear reactor may be configured for transportation to remote locations and may be able to provide 0.5 to 2 megawatts of power. The mobile heat pipe cooled fast reactor may contain a plurality of heat pipes that are proximate to a plurality of fuel pins inside the reactor. The plurality of heat pipes may extend out of the reactor. The reactor may be configured to be placed in a standard shipping container, and may further be configured to be contained within a cask and attached to a skid for easier transportation.

McClure, Patrick Ray↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions in the presence of a generalized incident local radiation field computed by Cloudy. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins (0.5-1, 1-4, and 13-16Ry) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors ≳10 times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions computed by Cloudy in the presence of a generalized incident local radiation field. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins ($0.5-1, 1-4$, and $13-16 \, \mathrm{Ry}$) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors $\gtrsim 10$ times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

Metal foam heat exchangers for air and gas cooling and heating applications

Improved heat exchangers according to several embodiments are provided. The heat exchangers provide improved heat transfer for air flow in wet and dry operating conditions, while minimizing pressure drop across the heat exchanger in some applications. According to one embodiment, an improved heat exchanger includes a plurality of metal foam fins between adjacent heat exchange conduits, the heat exchange conduits being arranged parallel to each other to define parallel flow paths between an inlet header and an outlet header. The metal foam fins occupy a cross-flow region between adjacent conduits, the fins having a fixed angular orientation or being rotatable in unison to vary the thermal capacitance of the heat exchanger.

Nawaz, Kashif↗

The Impact of Neutron Transfer Reactions on the Heating and Cooling of Accreted Neutron Star Crusts

Abstract Nuclear reactions heat and cool the crust of accreting neutron stars and need to be understood to interpret observations of X-ray bursts and long-term cooling in transiently accreting systems. It was recently suggested that previously ignored neutron transfer reactions may play a significant role in the nuclear processes. We present results from full nuclear network calculations that now include these reactions and determine their impact on crust composition, crust impurity, heating, and cooling. We find that a large number of neutron transfer reactions indeed occur and impact crust models. In particular, we identify a new type of reaction cycle that brings a pair of nuclei across the nuclear chart into equilibrium via alternating neutron capture and neutron release, interspersed with a neutron transfer. While neutron transfer reactions lead to changes in crust model predictions and need to be considered in future studies, previous conclusions concerning heating, cooling, and compositional evolution are remarkably robust.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control development and sizing analysis for a 5th generation district heating and cooling network using Modelica

5th generation district heating and cooling system (5GDHC) are a relatively new concept. They use a single district loop near ambient temperature to provide heating and cooling. This paper improves on the modelling and control of a 5GDHC system called the reservoir network. The study updates the sewage heat exchanger plant model to more realistically represent seasonal changes, uses refined pump models with variable efficiency, introduces a ground coupled district pipe model to consider the inertia of the district network and implements a new control strategy for geothermal storage and sewage heat exchanger. The new approach reduced operating costs, mainly due to pumping cost for storage, sewage heat exchanger plant and distribution pump, while increasing the overall robustness of the approach in different sizing conditions. Thanks to the new controller, the pumping consumption was reduced by 21% with respect to the original baseline. Furthermore, the new control makes the system take better advantage of design changes, when reducing borehole field size and increasing the sewage heat exchanger size, the pumping energy savings become 29% with respect to the original baseline. Lastly, borehole field temperature stability was analyzed through 40 years of simulation.

Zanetti, Ettore↗

Two-point and multiple-point spot heating and cooling

Apparatus and methods for producing thermal comfort using two point or multipoint heating or cooling that is applied to portion of a human body part to produce a warm or cool sensation over a larger area than that where the heating or cooling is directly applied. The body is induced to heat or cool itself by adjusting its neutral temperature setpoints. Increased warming perception from two-point, multipoint, and switching point stimulation causes downward adaptation in the neutral skin temperature of the user. Because spot heating and cooling sources operate at higher temperature differences from the skin than do area sources, they create a stronger perceived thermal sensation for the same power consumption. Point heating or cooling, rather than whole-area heating, can result in power savings and cost savings while improving occupant comfort.

Arens, Edward↗