Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat of absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

Thermodynamics-guided machine learning model for predicting convective boundary layer height and its multi-site applicability

Accurate estimation of convective boundary layer height (CBLH) is vital for weather, climate, and air quality modeling. Machine learning (ML) shows promise in CBLH prediction, but input parameter selection often lacks physical grounding, limiting generalizability. This study introduces a novel ML framework for CBLH prediction, integrating thermodynamic constraints and the diurnal CBLH cycle as an implicit physical guide. Boundary layer growth is modeled as driven by surface heat fluxes and atmospheric heat absorption represented with the low tropospheric stability, using the diurnal cycle as input and output. TPOT and AutoKeras are employed to select optimal models, validated against Doppler lidar-derived CBLH data, achieving an R 2 of 0.84 across untrained years. Comparisons of eddy covariance (ECOR) and energy balance Bowen ratio (EBBR) flux measurements show the same prediction capability. Models trained on the ARM SGP C1 site with ECOR data and tested at E37 and E39 yield R 2 values of 0.79 and 0.81, respectively, demonstrating their adaptability. The ML model trained with all sites' data slightly enhances the performance compared with ML models trained over single-site data. The interquartile range for predicted CBLH is consistently narrower than that for DL-derived CBLH, reflecting lower variability in predicted CBLH compared to DL-derived CBLH, which is influenced by additional factors, which are not well represented with the model inputs. The model's generalizability across multiple sites at the ARM SGP site demonstrates its potential for transfer to greater distances, offering a scalable approach for enhancing boundary layer parameterization in atmospheric models.

Chu, Yufei [Stony Brook Univ., NY (United States)]↗

Solar receivers and methods for capturing solar energy

Thermal receivers, systems, and methods are disclosed that efficiently capture concentrated solar energy into a plurality of heat absorption bodies for conversion into thermal energy. In an embodiment, the thermal receivers, systems, and methods enable simultaneous electricity conversion and thermal energy capture. The receiver design enables a high penetration of concentrated sunlight deep into the thermal receiver to increase light trapping and reduce thermal losses. The thermal receiver is integrated with a photovoltaic (PV) receiver platform that converts some of the incident light to electricity while passing the remaining light to the thermal receiver. In another embodiment, other thermal receivers, systems, and methods are disclosed that efficiently capture concentrated solar energy into a sheet of falling particles. In an embodiment, the thermal receivers, systems, and methods enable simultaneous electricity conversion and thermal energy capture.

Ho, Clifford K.↗

Membrane-based Ionic Liquid Absorption System for Ultra-Efficient Dehumidification and Heating

The project team – comprising the University of Florida (UF), GTI Energy, and Modine Manufacturing – sought to develop a highly efficient heat-powered absorption cycle with combined dehumidification and heat pumping. This DOE-supported project advanced the technology from a TRL of 3 to 6, culminating in the development of a 1,000 CFM system. Key innovations implemented in the system addressed the low efficiency, size, cost, and reliability challenges of conventional absorption cycles. Specifically, the system was enabled by: (1) a semi-open cycle that allowed simultaneous dehumidification and heat recovery, (2) non-crystallizing ionic liquids (ILs) that enabled “double-effect” operation at elevated temperatures without the need for costly control equipment, (3) a compact membrane-based absorber that confined the IL and directly cooled it to achieve low dew points, and (4) a novel, highly integrated desorber–condenser assembly that reduced size, weight, and cost. The technology was developed with commercial HVAC applications in mind, particularly for separate sensible and latent cooling (SSLC), an innovation aimed at achieving independent and more efficient humidity control.

42 ENGINEERING↗

Inferring Heat Flow in Laser Absorption Regions using Diagnostic Magnetic Fields

This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of micro-encapsulation on thermal characteristics of metallic phase change materials

Micro-encapsulated phase change material with metallic core can work under high temperature for energy storage purpose, making it an appealing candidate for renewable energy technologies, such as thermal energy storage for concentrating solar power plants. Here, the objective of this work is to study the impact of encapsulation on the thermal performance of the micro-encapsulated phase change materials under various operating conditions. To evaluate the thermal performance of the micro-encapsulated phase change material particles, the governing equation of transient heat conduction with phase change in spheres with composite walls is solved numerically. The impact of encapsulation shell on the convective heat transfer rate, total energy absorption, latent heat ratio, energy density, and duration of phase change is presented and analyzed under different operating conditions. Three different core materials including tin, aluminum and copper with distinct Stephan numbers are investigated. In addition to the encapsulation shell effect, this model can be used to study micro-encapsulated phase change materials with different material compositions, core to shell ratios, and it can be used to analyze the impact of air gaps in between materials. Understanding the thermal performance at particle level is essential, and the results of this study could potentially be used as input for thermal energy storage system level analysis, such as the charging and discharging processes.

42 ENGINEERING↗

Inferring Heat Flow in Laser Absorption Regions using Diagnostic Magnetic Fields: Abstract

This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Langdon effect in laser plasmas: Absorption and conduction

A plasma heated by inverse bremsstrahlung absorption of laser light develops a non-Maxwellian electron distribution function, called the Langdon effect [A. B. Langdon, Phys. Rev. Lett. 44, 575 (1980)]. These non-Maxwellian distributions are sufficiently long-lived to impact the absorption processes itself as well as the transport of heat by electrons. The theory of the Langdon effect in a homogeneous plasma is reviewed to clarify some aspects of Langdon's derivation as well as to confirm that the widely used super-Gaussian approximation works fairly well to describe the shape of the distribution function and reduction of the absorption rate. The Langdon effect on thermal conduction in an inhomogeneous plasma is developed by considering perturbations in a homogeneous absorbing plasma, which develops a heat flux due to both temperature and density gradients. A practical theory of the heat flux is developed by fitting the results of Vlasov–Fokker–Planck simulations, which avoids several approximations that compromised the usefulness of past theoretical predictions, most critically, the effect of electron–electron collisions on the fluxes. The present fits parameterize the coefficients of the temperature gradient (thermal conductivity) and the density gradient for a plasma of any ionization state and for any laser intensity where the theory of the Langdon effect remains locally valid. It is expected that this generalized theory of heat flow in an absorbing plasma will improve the predictive capability of radiation-hydrodynamics simulations of laser-produced plasmas, especially those formed in inertial confinement fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for CSP- Fabrication and Testing of Receiver Design Feature Specimens in a Simulating Lab Test via Laser Heating

Critical to the creation of a multi-component SiC receiver design concept capable of meeting the SETO CST cost goal objectives of <$150/kWth is the optimal utilization of material for solar absorption and heat transfer to transport fluid. This is to maximize the solar-thermal efficiency in the techno-economic analysis of derived use case. As a first step in preparation of sub-component design for on-sun test evaluations we use different proposed SiC absorber element in a customized laser heat flux test to assess an effective heat transfer coefficient characteristic of the design. The test results are analyzed to extract the effective heat transfer coefficient, thus enable optimization of the geometry of receiver components for heat transfer, efficiency attributes and the thermo-structural management of the components. High intensity CO2 laser is used in combination with air flow through the test specimen to assess the effective heat transfer coefficient under heat flux conditions corresponding to high solar concentrations in the range of 1000-2000 suns.

14 SOLAR ENERGY↗

Optimal Design and Operation of Intensified Absorbers with 3D-Printed Packing for Solvent-Based CO 2 Capture

Many potential solvent-based carbon capture processes suffer from a high heat of absorption of CO 2 that adversely affects the thermodynamic driving force. While interstage coolers are often used for removing a portion of the generated heat by removing the solvent or a portion of the solvent from a stage and cooling and returning it back to the absorber, they can be placed only at discrete locations in the tower. This work investigates intensified absorbers with 3D-printed packing that includes an internal cooler and therefore can be potentially used for maximizing the operational efficiency of the absorbers for CO 2 capture. The intensified absorber is modeled by using a generic, first-principles, equation-oriented absorber column model. Since the placement of these intensified packings would cause a loss of area/volume used for mass transfer, optimization of the proposed intensified absorber is performed by optimally selecting the locations at which to place these devices and designing them such that the trade-off due to the addition of the heat removal area and the resulting loss in the mass transfer area is accounted for. Results show that optimally placed and designed intensified packings can lead to a significant increase in the capture efficiency of the process in comparison to a similar column with no internal cooling. It is also observed that by optimally placing and designing intensified packings, the lean solvent flow rate to the absorber can be decreased, and the CO 2 lean loading can be increased while still maintaining the same capture efficiency. These process changes can lead to a substantial reduction in the cost of capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamic expansion and near-infrared absorption of x-ray heated aluminum plasmas

We use x-ray pulses from dense argon plasmas at the Z Machine (Sandia National Laboratories) to generate hypersonic aluminum plasmas akin to material ejecta during proposed planetary defense missions, fusion reactor wall excursions, and other high-energy density processes. Near-infrared absorption is used to diagnose the controlled expansion of the plasmas through cylindrical cavities following their generation from x-ray heating of solid aluminum 7075 alloy. The data are compared to multidimensional radiation hydrodynamics simulations utilizing the ALEGRA multiphysics code, accounting for the dynamics of radiation scattering, material phase change, plasma expansion, thermal re-irradiation, and interactions with the cavity and with the infrared beams. To allow for accurate simulation, density functional theory is used to apply the Hagen–Rubens relation for the far-infrared and is adjoined with a detailed configuration accounting model using the Propaceos code, producing opacities spanning 10 −1 –10 4 eV photon energy for aluminum 7075 alloy, and in comparison with pure aluminum. The model is found to agree with experimental data in the higher-fluence regime when the Hagen–Rubens relation is applied. The ejected material, which is observed to travel up to 55 km/s, is comprised of a strongly ionized, non-LTE plasma front at ∼10 eV temperature followed by a weakly ionized LTE gas at higher density. The present findings lend some confidence to the broad-range equation of state and infrared opacity models for weakly ionized aluminum plasmas while demonstrating an approach to their future refinement, with potential application to astrophysical plasmas and other extreme processes.

Adiabatic process↗

Simulation Studies of Electromagnetic Energy Absorption by Hydride Materials

This paper investigates the key parameters that contribute to electromagnetic (EM) energy absorption and heating of hydride materials which could be used to release hydrogen for use as a fuel. Our simulation study using COMSOL focuses on EM energy absorption and resulting temperature rise in a thin circular slab of hydride material using resonant dipole and loop antennas. Presented results delineate the effects of conductivity, relative permeability, antenna type and slab size on temperature rise when the distance and amount of RF power are kept fixed.

Brown, Michael A.↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

A Comparative Radiative Property Evaluation of Sintered Bauxite and AMS4003 Ceramic Particles

The radiative properties of sintered bauxite (ACCUCAST ID80) and AMS4003 particles were measured and compared to assess their performances as direct absorption and heat transfer media for particle-based concentrated solar power (CSP) plants. Reflectance measurements were performed over the spectral range 0.2–20 µm and used to calculate solar and thermal emission properties of the particles. In addition, reflectance was measured as a function of temperature up to 1000 °C for the spectral range 1–20 µm. The solar absorptance of AMS4003 was greater than that of ACCUCAST both before and after thermal cycling of the materials at 1000 °C, although thermal cycling was found to substantially decrease the solar absorptance of both materials. The thermal emittance of AMS4003 was also greater than that of ACCUCAST at all temperatures tested. Finally, the radiaitve properties measured in this study were used to estimate absorber efficiencies as a way to compare the particles in terms of their performance in a solar receiver. AMS4003 yielded greater efficiencies than ACCUCAST, suggesting its potential as a material for CSP.

14 SOLAR ENERGY↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗

A dynamic thermal algal growth model for pilot-scale open-channel raceways

Here this study describes the makeup of and results from a simulation consisting of a lumped thermal model integrated with a dynamic algae growth model to simulate the microalgae productivity of an open-channel raceway cultivation system. The thermal model considers the dynamic effects of weather, light absorption, convective heat transfer, radiation heat transfer, conductive heat transfer, thermal capacitance, and water control strategies. The dynamic algae growth model solves a set of ordinary differential equations consisting of growth functions dependent on incident radiation, temperature, nutrient availability, basal metabolism, and losses due to dark- and photo-respiration. Relative errors in the predicted ash-free dry weight of Nannochloropsis oceanica are 12.5%, -6.1%, and 4.4% for three separate replicates of cultivation cycles (~4.2 m 2 ) performed at AzCATI during the ATP 3 Unified Field Studies in Fall, Spring, and Summer. This research demonstrates that thermal modeling is an essential contributor to the validation of microalgae growth models.

09 BIOMASS FUELS↗

Modeling laser interactions with aluminum and tantalum targets using a hybrid atomistic-continuum model

A hybrid atomistic-continuum method can model the microstructure evolution of metals subjected to laser irradiation. This method combines classical molecular dynamics (MD) simulations with the two-temperature model (TTM) to account for the laser energy absorption and heat diffusion behavior. Accurate prediction of the temperature evolution in the combined MD-TTM method requires reliable accuracy in electron heat capacity, electron thermal conductivity, and electron–phonon coupling factor across the temperatures generated. This study uses the electronic density of states (DOS) obtained from first-principle calculations. The calculated electron temperature-dependent parameters are used in MD-TTM simulations to study the laser metal interactions in FCC and BCC metals and the phenomenon of laser shock loading and melting. This study uses FCC Al and BCC Ta as model systems to demonstrate this capability. When subjected to short pulsed laser shocks, the dynamic failure behavior predicted using temperature-dependent parameters is compared with the experimentally reported single-crystal and nanocrystalline Al and Ta systems. The MD-TTM simulations also investigate laser ablation and melting behavior of Ta to compare with the ablation threshold reported experimentally. In conclusion, this manuscript demonstrates that integrating the temperature-dependent parameters into MD-TTM simulations leads to the accurate modeling of the laser–metal interaction and allows the prediction of the kinetics of the solid–liquid interface.

36 MATERIALS SCIENCE↗