Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat of absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Effect of melting processes on the structure and precipitation of a heavy rainstorm in Beijing

Abstract Beijing and its surrounding areas experienced a torrential rainstorm from July 21 to 22, 2012. Previous studies have shown that melting was the main rainwater source in this process. In this paper, melting conversion processes were set to zero (NPMLT test) to analyze the effect of microphysical processes on the structure and precipitation of the convective system. The results showed that without the melting processes, the wind shear at the 700 hPa level decreased, and the wind field in Beijing and its surrounding areas changed. The cold front system moved faster, and the rainfall amount only reached the low rain level, much lower than that during the actual rainstorm. The hydrometeors sources had apparently changed. Though the latent heat release was large and little latent heat absorption occurred in the NPMLT test, the net latent heat did not affect the development of the convective system, and the precipitation was low. Therefore, microphysical processes greatly influence precipitation and convective system.

Guo, Chunwei↗

The encasulation effect on thermal performance of micro-encapsulated phase change materials during energy absorption

Understanding the performance of the thermal storage materials is required to successfully meet the needs of next generation concentrating solar power projects. This study focuses on the thermal characteristics of the micro-encapsulated phase change material (MEPCM) with metallic core under high temperature. A numerical model was developed and verified to study the transient heat absorption process of MEPCMs made of tin, aluminum and copper core. Convective heat transfer rate, total energy absorption and volumetric energy density were presented. The effect of encapsulation on theses variables was analyzed under various boundary and initial conditions. Its impact on characteristic time variables was discussed. The method presented can be adopted to analyzing both manufacturing and application processes for MEPCMs of various compositions, during which melting and solidification happen. Given certain operating conditions, the results from the model can be referenced to obtain optimal thermal performance of these materials.

Benner, Jingru↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simplified method for calculating the atmospheric heating rate by absorption of solar radiation in the stratosphere and mesosphere

Calculations of the atmospheric heating rate by absorption of solar radiation by O3, H2O, and CO2 are reported. The method needs only seven parameters for each molecule and is particularly useful for heating calculations in three-dimensional global circulation models below 80 km. Applying the formula to the observed distributions of O3, H2O, and CO2 produces reasonable latitudinal and seasonal variations in the heating rate. The calculated heating rate, however, is sensitive to the global distributions of the absorbing gases, and uncertainties in the O3 distribution above approximately 50 km and the H2O distribution below approximately 20 km may seriously affect the global distributions of the heating rate in these regions.

Shimazaki, T.↗

Non-Venting Thermal and Humidity Control for EVA Suits

Future EVA suits need processes and systems to control internal temperature and humidity without venting water to the environment. This paper describes an absorption-based cooling and dehumidification system as well as laboratory demonstrations of the key processes. There are two main components in the system: an evaporation cooling and dehumidification garment (ECDG) that removes both sensible heat and latent heat from the pressure garment, and an absorber radiator that absorbs moisture and rejects heat to space by thermal radiation. This paper discusses the overall design of both components, and presents recent data demonstrating their operation. We developed a design and fabrication approach to produce prototypical heat/water absorbing elements for the ECDG, and demonstrated by test that these elements could absorb heat and moisture at a high flux. Proof-of-concept tests showed that an ECDG prototype absorbs heat and moisture at a rate of 85 W/ft under conditions that simulate operation in an EVA suit. The heat absorption was primarily due to direct absorption of water vapor. It is possible to construct large, flexible, durable cooling patches that can be incorporated into a cooling garment with this system. The proof-of-concept test data was scaled to calculate area needed for full metabolic loads, thus showing that it is feasible to use this technology in an EVA suit. Full-scale, lightweight absorber/radiator modules have also been built and tested. They can reject heat at a flux of 33 W/ft while maintaining ECDG operation at conditions that will provide a cool and dry environment inside the EVA suit.

Izenson, Mike↗

Rocket engine thrust chamber wall temperature distribution calculation and analysis

An analytical computational concept is presented which predicts the temperature profiles along a regeneratively cooled thrust chamber wall on the hot gas side and on the coolant side, and also the coolant bulk temperature profile. The computational model is based upon a coupling of the boundary layer heat transfer process with the heat transfer process through the chamber wall and the coolant flow heat absorption. The calculation is started with approximate temperature distributions for the hot gas side wall and the coolant flow. The iteration process of the computer program is terminated when the total heat transfer rates from the hot gas boundary layer to the wall and from the wall to the coolant are equal. The computer program for the integration of regenerative cooling process to a thrust chamber is kept general such that this program can be used with any boundary layer analysis computer program for temperature profile and heat transfer studies. A sample application of this concept is shown by using a boundary layer analysis program for the RL10 rocket engine thrust chamber.

Saha, H.↗

Two-Flux and Green's Function Method for Transient Radiative Transfer in a Semi-Transparent Layer

A method using a Green's function is developed for computing transient temperatures in a semitransparent layer by using the two-flux method coupled with the transient energy equation. Each boundary of the layer is exposed to a hot or cold radiative environment, and is heated or cooled by convection. The layer refractive index is larger than one, and the effect of internal reflections is included with the boundaries assumed diffuse. The analysis accounts for internal emission, absorption, heat conduction, and isotropic scattering. Spectrally dependent radiative properties are included, and transient results are given to illustrate two-band spectral behavior with optically thin and thick bands. Transient results using the present Green's function method are verified for a gray layer by comparison with a finite difference solution of the exact radiative transfer equations; excellent agreement is obtained. The present method requires only moderate computing times and incorporates isotropic scattering without additional complexity. Typical temperature distributions are given to illustrate application of the method by examining the effect of strong radiative heating on one side of a layer with convective cooling on the other side, and the interaction of strong convective heating with radiative cooling from the layer interior.

Siegel, Robert↗

Heat storage in alloy transformations

The theory of eutectic transformation was examined to find guidelines to the best material combinations to examine. The heats of transformation were measured calorimetrically, and the volume changes of expanding solid mixtures and homogeneous liquid solutions, especially during the transformation between the two states at fixed temperature, were measured by changes in X-ray absorption. Heat flow models appropriate to storage in phase change materials were developed along with efficient calculating procedures so that the relative importance of the problems associated with energy storage density, heat conduction, and similar properties could be assessed.

Birchenall, C. E.↗

Cryogenic Fluid Management Technology Development for Nuclear Thermal Propulsion

The purpose of this paper is to investigate, facilitate a discussion and determine a path forward for technology development of cryogenic fluid management technology that is necessary for long duration deep space missions utilizing nuclear thermal propulsion systems. There are a number of challenges in managing cryogenic liquids that must be addressed before long durations missions into deep space, such as a trip to Mars can be successful. The leakage rate of hydrogen from pressure vessels, seals, lines and valves is a critical factor that must be controlled and minimized. For long duration missions, hydrogen leakage amounts to large increases in hydrogen and therefore vehicle mass. The size of a deep space vehicle, such as a mars transfer vehicle, must be kept small to control cost and the logistics of a multi launch, assembled in orbit vehicle. The boil off control of the cryogenic fluid is an additional obstacle to long duration missions. The boil off caused by heat absorption results in the growth of the propellant needs of the vehicle and therefore vehicle mass. This is a significant problem for a vehicle using nuclear (fission) propulsion systems. Radiation from the engines deposits large quantities of heat into the cryogenic fluid, greatly increasing boil off beyond that caused by environmental heat leakage. Addressing and resolving these challenges is critical to successful long duration space exploration. This paper discusses the state of the technology needed to address these challenges and discuss the path forward needed in technology development.

Taylor, Brian↗

Energy demand reduction in the built environment using shallow geothermal integrated energy systems: Part II – Hybrid ground source heat pump for building heating

The research collection aims at finding the various possible opportunities for the effective integration of shallow geothermal energy (SGE) to decrease the energy demand in the built environment and to reduce emission associated with it. The direct utilization of SGE using a ground source heat pump (GSHP) has been reviewed in comprehensive review part I and part II. From the extensive review, we have found that the hybrid GSHP is needed to avoid ground thermal imbalance and peak demand. Hybrid GSHP can adopt various supplemental heat sources and sinks according to the local climatic conditions and the balance of energy demands. The primary focus on the integration of subsystems such as biomass, solar energy (PV, PVT, and collector), phase change material, micro gas turbine, and absorption heat pump with GSHP is presented for heating application. This comprehensive review part III highlights the recent research findings and a potential gap in hybrid GSHP for further research and developments

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗