Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Directional solidification with heat losses

The upward directional solidification of a dilute binary alloy in a tall, thin, two-dimensional slot is considered. Heat losses from the sidewalls produce curved isotherms, interface deformations, and melt convection. An asymptotic approach is used which relates the small heat loss to the thinness of the solidification cell, and solutions are obtained for the resulting melt convection, interface deflection, and the distribution of heat and solute. The model is compared to the numerical results of Chang and Brown (1983) which exclude the effects of solute buoyancy and thermodynamic equilibrium at the interface. The radial segregation at the interface (consistent with both interface shapes and temperature fields) is computed, and it is found that the radial segregation is independent of interfacial shapes; the radial segregation cannot be calculated from only a knowledge of the interface shape.

Brattkus, K.↗

Experimentally-determined external heat loss of automotive gas turbine engine

An external heat balance was conducted on a 150 HP two-shaft automotive gas turbine engine. The engine was enclosed in a calorimeter box and the temperature change of cooling air passing through the box was measured. Cooling airflow ranges of 1.6 to 2.1 lb-per-second and 0.8 to 1.1 lb-per-second were used. The engine housing heat loss increased as the cooling airflow through the calorimeter box was increased, as would be the case in a moving automobile. The heat balance between the total energy input and the sum of shaft power output and various losses compared within 30 percent at engine idle speeds and within 7 percent at full power.

Meng, P. R.↗

A detailed experimental and modeling comparison of molecular radiative heat loss in a spark-ignition engine

Radiative heat transfer has been chiefly considered negligible in internal combustion engines, except for Diesel engines where soot radiation was recognized as a significant radiative transfer source. Only more recently, detailed simulations have shown that molecular radiation can be substantial as well. In extension to this, molecular radiative heat transfer can reach detectable levels of about 5–10% of the total heat transfer in spark-ignited engines. The broadband radiative nature of the significant emitting molecules, carbon dioxide and water, makes it necessary to address whether radiative trapping plays a substantial role in either total heat loss or energy redistribution within the cylinder. An experimental setup that allows measurements of the infrared emissions at a 2-crank-angle-degree resolution was developed to determine the importance of radiative trapping by carbon dioxide and water. Measurements were conducted in the well-characterized and documented TCC-III engine at the University of Michigan. The engine operated on a stoichiometric propane/air mixture at a speed of 1,300 RPM. Large Eddy Simulations with added line-by-line photon Monte-Carlo simulations of the molecular radiation were an integral part of this study to plan and devise the measurements. Post-processing of the simulation data included an accurate representation of the experimental volume from where infrared signals are collected. Additionally, the experimental data were used for validation of the photon Monte-Carlo simulations. Joint analysis of experimental and simulated spectra allowed quantifying the significance of radiative trapping. Results show the significant role of radiative trapping when predicting radiative heat transfer in the TCC-III engine.

42 ENGINEERING↗

Heat Loss Imagery

Infrared scanning devices are being used to produce images that show, by color or black-and-white shading differences, which buildings and homes are losing heat to the outdoors, and how much. Heat loss surveys done by Texas Instruments, Daedalus Enterprises, Inc. and other companies have growing acceptance of their services among industrial firms, utilities, local governments, and state and federal agencies interested in promoting heat loss awareness and inspiring corrective actions.

Source record↗

Comparison of Equivalent System Mass (ESM) and Modeling Results from Improved Heat Loss Approaches for the Carbon Dioxide Deposition (CDep) System

Proper insulation on any type of cryogenic system is essential for its performance to be optimal, as a poorly insulated system will allow for significant heat loss. Different insulation arrangements for CDep were considered, and performance was simulated and measured in Modelica. Heat loss was correlated to cycle time and CO2 deposition efficiency, which led to overall system power usage. Mass, volume, and power consumption were weighted accordingly in the ESM calculations to guide selection of the CDep insulation scheme.

Marian Alcid↗

1D Heat Loss Models Validation Experiment

Contains data from the model validation in the 1D Heat Loss Models to Predict the Aquifer Temperature Profile during Hot/Cold Water Injection Project. The data include two COMSOL models (2D axisymmetric benchmark model and 2D Vinsome model), one python code (1D Vinsome based FEM numerical simulation), one matlab main code (1D Newton analytical solution and all results comparison visualization), and output files generated from the above models.

1D↗

Light masking of circadian rhythms of heat production, heat loss, and body temperature in squirrel monkeys

Whole body heat production (HP) and heat loss (HL) were examined to determine their relative contributions to light masking of the circadian rhythm in body temperature (Tb). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of body temperature and activity. Feeding was also measured. Responses to an entraining light-dark (LD) cycle (LD 12:12) and a masking LD cycle (LD 2:2) were compared. HP and HL contributed to both the daily rhythm and the masking changes in Tb. All variables showed phase-dependent masking responses. Masking transients at L or D transitions were generally greater during subjective day; however, L masking resulted in sustained elevation of Tb, HP, and HL during subjective night. Parallel, apparently compensatory, changes of HL and HP suggest action by both the circadian timing system and light masking on Tb set point. Furthermore, transient HL increases during subjective night suggest that gain change may supplement set point regulation of Tb.

Non-NASA Center↗

Thermal Capacitance (Slug) Calorimeter Theory Including Heat Losses and Other Decaying Processes

A mathematical model, termed the Slug Loss Model, has been developed for describing thermal capacitance (slug) calorimeter behavior when heat losses and other decaying processes are not negligible. This model results in the temperature time slope taking the mathematical form of exponential decay. When data is found to fit well to this model, it allows a heat flux value to be calculated that corrects for the losses and may be a better estimate of the cold wall fully catalytic heat flux, as is desired in arc jet testing. The model was applied to the data from a copper slug calorimeter inserted during a particularly severe high heating rate arc jet run to illustrate its use. The Slug Loss Model gave a cold wall heat flux 15% higher than the value of 2,250 W/sq cm obtained from the conventional approach to processing the data (where no correction is made for losses). For comparison, a Finite Element Analysis (FEA) model was created and applied to the same data, where conduction heat losses from the slug were simulated. The heat flux determined by the FEA model was found to be in close agreement with the heat flux determined by the Slug Loss Model.

Hightower, T. Mark↗

Test-Derived Effective Emittance for Cassini MLI Blankets and Heat Loss Characteristics in the Vicinity of Seams

Thermal performance of Cassini MLI blankets was characterized in thermal vacuum tests. Effective emittance was derived for the standard and high-temperature layups, with or without micrometeoroid protection standoffs, and for a high-performance duo-layup with staggered seams. The all-Kapton layup wa shown to have a 19% higher effective emittance than the hybrid Kapton-Mylar layup, and the duo-layup exhibited a dramatic capability of reducing heat dissipation by 2.6 fold. Several different definitions of effective emittance are discussed, and their relations to distinct hardware-MLI configurations and corresponding modeling techniques clarified. Large temperature differences (up to 70 C) were observed between the center and seam of a blanket. Heat losses in the vicinity of seams are qualified, and a major MLI heat loss mechanism elucidated.

Cassini↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver (2 nd Ed)

High - temperature particle receivers are being pursued to enable next - generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 C) to enable more efficient power cycles, lower overall system costs, and emerging CSP - based process - heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera - based imaging methods were developed and applied to both laboratory - scale and larger 1 MW t on - sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle - sampling methods using volumetric particle - air samplers were applied to the on - sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3 - D printed tipping buckets and tethered balloons were also developed and applied to the on - sun particle - receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera - based imaging methods correlated well with measured values during the on - sun tests.

14 SOLAR ENERGY↗

Corona Formation and Heat Loss on Venus by Coupled Upwelling and Delamination

Coronae are volcanotectonic features that are unique to Venus and are interpreted to be small-scale upwellings. A model in which upwelling causes delamination at the edge of the plume head, along with deformation of a pre-existing depleted mantel Layer, can produce the full range of topographic forms of coronae. If half of the coronae are active, delamination of the lower lithosphere could account for about 10% of venus's heat loss, with another 15% due to upwelling. Delamination may occur in other geologic enviroment and could help account for 'Venus' heat loss 'deficit'.

Corona Formation Venus↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver

High-temperature particle receivers are being pursued to enable next-generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 °C) to enable more efficient power cycles, lower overall system costs, and emerging CSP-based process-heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera- based imaging methods were developed and applied to both laboratory-scale and larger 1 MW t on-sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle-sampling methods using volumetric particle-air samplers were applied to the on-sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3-D printed tipping buckets and tethered balloons were also developed and applied to the on-sun particle-receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera-based imaging methods correlated well with measured values during the on-sun tests.

14 SOLAR ENERGY↗

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗