Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “health physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Criticality Accident Alarm System Benchmark Creation

Over the last few decades, the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group has focused on gathering critical and subcritical benchmark experiment data from different facilities around the world for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook). The compiled data can be used by criticality safety analysts to help validate their calculation tools and cross-section libraries for a variety of applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Engineering Enrollments and Degrees Survey, 2019 Data (Brief 82)

The 2019 survey includes degrees granted between September 1, 2018 and August 31, 2019, and enrollments for fall 2019. Thirty-four nuclear academic programs were surveyed with all but two programs responding. The enrollments and degrees data include students majoring in nuclear engineering or in an option program equivalent to a major. Some nuclear engineering programs have indicated that health physics option enrollments and degrees are also reported in the health physics enrollments and degrees survey.

99 GENERAL AND MISCELLANEOUS↗

Results for Gamma-Ray Spectroscopy Characterization of Residual Radioactivity on Personal Protective Clothing

In early 2019, Health Physics Services (HPS) personnel put together a test plan to use the shielded gamma-ray spectroscopy instruments in the Health Physics Services Technical Laboratory (HPSTL) to perform a series of measurements on laundered personal protective clothing used in radiological areas at the Savannah River Site (SRS). That test plan describes the methodology used to determine the quantities of laundry to be obtained from operational facilities, the methods for quality control checking the instruments throughout the measurement period, and the physical arrangement of samples in the counting shields. The test plan is documented in SRNS-J6700-2019-00037 (Reference 1).

61 RADIATION PROTECTION AND DOSIMETRY↗

Systems and methods for control system security

A resilient security agent determines a cyber and/or physical health of a control system by, inter alia, communicating cyber-physical key data through cyber-physical control paths of the system, and determining error introduced by the communication. The resilient security agent may be further configured to verify the integrity of acquired cyber-physical state information. The cyber health of the control system may be evaluated by comparing the acquired cyber state information to one or more cyber state profiles. The physical health of the control system may be evaluated by comparing the acquired physical state information to one or more physical state profiles.

97 MATHEMATICS AND COMPUTING↗

Radiation Protection [Slides]

Health Physics is a profession dedicated to the protection of human health and the environment from the dangers of radiation and radioactivity WHILE providing for its beneficial use.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Systems of Radiological Protection for Ionizing and Non-Ionizing Radiation

This paper summarizes the presentations and panel discussion held at Plenary Session 1 of the 16th IRPA International Congress/69th Health Physics Society Annual Meeting, in Orlando, FL, in July 2024. Plenary Session 1 discussed the basics of the systems of radiological protection (RP) for ionizing radiation (IR) and non-ionizing radiation (NIR) and included five presentations and a panel discussion. Rodney Croft, Chair of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), delivered the first presentation. Croft introduced the System of RP for NIR and provided an overview of ICNIRP’s coverage and current areas of work. Werner Rühm, Chair of the International Commission on Radiological Protection (ICRP), delivered the second presentation. He gave an overview of the System of RP for IR and covered the key principles of justification, optimization, and dose limitation, including the current plans of ICRP toward the envisaged revision of the System of RP. The third speaker, Sigurður Magnús Magnússon, from the International Radiation Protection Association (IRPA), provided the perspective of the RP professionals on the development of the Systems of RP for IR and NIR. Emilie van Deventer, from the World Health Organization (WHO), presented WHO’s views of both Systems of RP and discussed the relevant current activities of WHO with regard to IR and NIR. Kathryn Higley, President of the National Council on Radiation Protection and Measurements (NCRP), delivered the final presentation. Higley outlined the history of NCRP, the differences between ICRP and NCRP, and discussed the role of the NCRP in the System of RP, including NCRP’s role to analyze mechanisms of interaction of NIR with biological systems, including humans. The session concluded with a fruitful panel discussion, where the audience had the opportunity to ask the five invited speakers questions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of WELL certification on occupant satisfaction and perceived health, well-being, and productivity: A multi-office pre- versus post-occupancy evaluation

The WELL Building Standard (WELL) is currently one of the most comprehensive building certification programs that aim to enhance the health and well-being of building occupants. However, there is a lack of systematic evaluation of the effectiveness of WELL in achieving its goal. This study investigates the impact of WELL certification on occupant satisfaction with the workplace and occupant perceived health, well-being, and productivity. More than 1300 pre- and post-occupancy survey responses provided by the nearly same cohort of occupants from six companies in North America were quantitatively analyzed. The results showed that transitioning to WELL certified offices from non-WELL certified offices had a positive impact on occupant satisfaction with the workplace and occupant perceived health, well-being, and productivity, with increases in means from pre-to post-occupancy being highly statistically significant. The majority of the studied occupant satisfaction parameters as well as occupant perceived mental health had large effect sizes. While they improved from pre-to post-occupancy, the analysis revealed small effect sizes for occupant perceived physical health and self-assessed productivity. The majority of the effect sizes for the perceived well-being parameters were large and medium. In addition to analyzing the survey responses in aggregate, the responses were examined at the individual company level to confirm the by-company and aggregate findings aligned.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combined Effort to De-Inventory the New Brunswick Laboratory of Plutonium Certified Reference Materials - 20504

To de-inventory plutonium Certified Reference Materials standards (CRMs) from the New Brunswick National Laboratory (NBL), the Argonne National Laboratory (ANL) and Savannah River National Laboratory (SRNL) formed a unique team. This teaming arrangement leveraged the different capabilities and expertise of both laboratories, helping to ensure the effort would be performed both safely and cost-effectively. With the NBL then physically housed on the ANL site, ANL served as the host-site, providing the necessary facilities and support services (e.g., supplying everything from hoods, loading equipment, and scales to Health Physics supports). From a packaging perspective, ANL's responsibilities focused mainly on characterizing and preparing the contents for shipment, followed by performing the Shipper of Record activities. With SRNL being the Package Design Authority of the 9978, the Type B packaging used for this effort, SRNL's scope included developing a Safety Analysis Report in Packaging (SARP) Letter Amendment to add the CRMs as authorized contents to the 9978. Recognizing competency, ANL prodigiously tasked SRNL to perform the actual loading of the CRMs into the 9978s, while physically on the ANL site. This paper details five different aspects of this effort. They are: 1. Characterization/validation of the CRM contents. 2. Development of the 9978 SARP Letter Amendment for the content change. 3. Development of the nitrogen inerting method to address SARP identified potential flammability concerns. 4. Renewal of the SRNL 9978 loading procedure. 5. Performance of the actual work execution activities. In 2017, the first nine packages were successfully loaded and shipped from NBL, while in 2019, the last ten were successfully loaded and planned for shipment. Without ANL leveraging SRNL's strengths, the de-inventorying of NBL of its plutonium CRMs would have likely taken many years longer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Lithium-ion battery physics and statistics-based state of health model

A pseudo-2d model using COMSOL Multiphysics® software is developed to simulate performance and performance degradation of Li-ion batteries consisting of layered and olivine cathodes with graphite anode when subjected to peak shaving grid service. Multiple degradation pathways are considered, including solid electrolyte interphase (SEI) formation and breakdown at the anode, cathode dissolution and its synergistic effect on SEI formation at the anode. The model is validated by simulating commercial cylindrical cell performance. A global model is developed to simulate performance across all chemistries, along with individual chemistry models using global model parameters as initial values. There is good agreement between these models for various optimization parameters such as SEI equilibrium potential, cathode dissolution exchange current density, solvent diffusivity in the SEI and SEI ionic conductivity. To circumvent time constraints related to the COMSOL model, a 0d global model is developed which fits data well and provides more clarity on differences in cathode dissolution exchange current density. Again, good agreement for various optimization parameters is obtained among the COMSOL global & individual chemistry models and the 0-d model. The lessons learned from the physics-based model is used to develop a top down statistics-based model using current, voltage and anode volumetric change per mole lithium intercalated, along with their interactions as degradation predictors. This model predicts out of sample degradation for multiple grid services and electric vehicle drive cycle with high accuracy and provides the pathway to develop an efficient battery management system combining machine learning and findings from physics-based computationally intensive algorithms.

Crawford, Aladsair J.↗

Early Lab scientists had questions, Plastic Man gave them answers

He was a willing subject in countless scientific experiments, a superstar of health physics, as well as a favorite photo prop -- and not just around Halloween time. He was Plastic Man. Beginning in the mid-1950s, the Lab (then called Los Alamos Scientific Laboratory) often relied on several life-sized synthetic test subjects to avoid experimenting on people. In the early days of the Laboratory, not much was known about how different radioisotopes interacted with the human body and how much it absorbed from different radiation sources. Answering queries like these is where Plastic Man came in. For example, during the 1950s and 1960s, the Lab was tasked with developing nuclear rockets for space exploration under the Rover Program. One of the concerns was how astronauts might be affected when exposed to radiation from these rocket engines. So, the Lab’s health group set up an experiment in which Plastic Man was placed in close proximity to an experimental Rover nuclear rocket engine. Running experiments like this using Plastic Man kept humans safer. How life-like was he? There were actually two variations of Plastic Man. Both had hard plastic exteriors, but one of the models encased a real human skeleton. They also had movable joints and simulated organs, such as a liver, a spleen, kidneys, lungs and a thyroid. Although Plastic Man in its entirety was used in experiments, much of the data collected were from research conducted inside on these replicated organs. In time, technology advanced and Plastic Man was able to retire from the Lab. He found a new home in 1964 as a display at the Laboratory’s science museum, and is sometimes displayed today in the Bradbury Science Museum in downtown Los Alamos.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Preparing Underrepresented Minorities for STEM Careers in Energy

The purpose of the grant was to increase the participation of underrepresented minorities and women in STEM disciplines that are critical for the energy industry. The grant was implemented by the Fort Valley State University’s (FVSU) Cooperative Developmental Energy Program (CDEP). FVSU-CDEP enrolled two cohorts of six academically talented freshmen students into its accelerated five-year 3+2 dual degree STEM program. In the 3+2 dual degree format, students enroll at FVSU for three years and earn bachelor’s degrees in biology, chemistry, or mathematics and transfer to a partnering university for two years to earn second bachelor’s degrees in engineering, geology/geophysics, or health physics. FVSU-CDEP partnering universities consist of Georgia Tech, Grand Valley State University, Penn State University, University of Alabama, University of Arkansas, University of Nevada-Las Vegas, and the University of Texas-Austin. Cohort I enrolled at FVSU fall semester of 2017 and cohort II enrolled fall semester of 2020. All six of the students in cohort I earned bachelor’s STEM degrees at FVSU and transferred to a partnering university. Five of the six who transferred to a partnering university earned the second bachelor’s degree. One student transferred from a partnering university to a non-partner university to continue pursuit of the second degree. All students in cohort I had internships, attended professional meetings, and made presentations. Cohort II enrolled the fall-semester of 2020 in the midst of COVID epidemic. Cohort II was only funded for one year, 2020/2021. The DOE Office of Economic Impact and Diversity informed the PI that there would not be any funding for the fifth and final year (2021/2022) of the project. All six of the students in cohort II earned bachelor’s STEM degrees from FVSU and transferred to one of CDEP’s partnering universities. One of the students in cohort II graduate with an MS degree spring of 2023. Currently, four are pursuing graduate degrees at partnering universities and one withdrew from a partnering school because health reasons. Students in cohort II opportunities to participate in internship were negatively impact by the COVID epidemic (2020-2022). Of the 12 scholarship participants, 8 were females. Fifty percent of the males pursued second degrees in Engineering while only twenty-five percent of the females chose Engineering as their second degree.

42 ENGINEERING↗

Baseline Hypothetical Facility for the Production of 131 I, 99 Mo, and 133 Xe from HALEU Fission Targets

The report describes the development of a hypothetical facility to produce the pharmaceutical radioisotope 131 I at an amount of 60 curies per week via the fission of a High Assay Low Enriched Uranium (HALEU) target, along with the chemical and physical processes and equipment needed to separate the 131 I and co-produced 99 Mo and 133 Xe. The hypothetical design was carried out using a 10 MWt research reactor. The irradiation calculation determined that three HALEU targets with aluminum cladding can be used to produce 60 Ci/week of 131 I, 750 Ci/week of 99 Mo and 560 Ci/week of 133 Xe. The process selected for the baseline design uses caustic dissolution of the target material with ion exchange processes to separate and purify the iodine and molybdenum. The xenon is processed using a cryogenic carbon bed separation process. Target processing occurs in seven shielded hot cells with a total footprint of 16m 2 and waste management occurs in an eight hot cell with a 2.5 m 2 footprint. Waste generated from the processing of the three targets per week would generate less than 4 shielded drums of waste annually. These hot cells would need varying levels of shielding due to the amount of fission products being handled in the unit. Hot cell facilities also require support services including QA/QC, health physics, administrative staff, operator changing room, radiological buffer areas, and waste storage. The overall facility would require a footprint of 1050 m 2 with 20.25 m 2 of shielded hot cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tensioned metastable fluid detector sensing technology for multifarious-multiscale applications in the nuclear fuel cycle

The nuclear fuel cycle presents formidable 10 30+ multiscale challenges for high-efficiency spectroscopic sensing of alpha-neutron-fission radiation signatures amidst extreme gamma-beta radiation backgrounds at various stages of the cycle; it involves diverse arenas ranging from continuous/pulsed power production, security/safeguards, spent fuel, environmental remediation, and personnel health-dosimetry. This paper discusses the novel tensioned metastable fluid detector (TMFD) sensor technology. It discusses the results of studies demonstrating extreme (10 4 Sv/h) gamma-beta field blind high intrinsic efficiencies (80–100%) for neutron-alpha-fission radiation spectrometric detection. Example studies discussed in this paper include Neutron detection with spectroscopy; H*10 neutron radiation dosimetry upwards from ultra-low10 −2 µSv/h levels; Air and/or liquid-borne trace (10 –3 Bq/mL) quantity, 1 keV energy resolved alpha/fission spectroscopy for Rn/Po/U/Pu/Am environmental isotope assays at 106:1 (β:α) ratios; Directional-position enabled extended standoff tracking of neutron emitting (shielded/unshielded) special nuclear materials while stationary or moving at highway speeds; and, U.S. Department of Energy nuclear complex wide nuclear waste reprocessing, criticality safety, health physics, and environmental applications.

Alpha-fission-neutron spectrometry↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗