Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gyrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

A poloidal high- k scattering system for NSTX-U

A previous 5-channel tangential high-k scattering system is being replaced by an 8-channel, poloidal high-k scattering system on the National Spherical Torus eXperiment Upgrade (NSTX-U) device located in Princeton, NJ, USA. The 693 GHz poloidal scattering system replaces a 280 GHz tangential scattering system to study high-k electron density fluctuations on NSTX-U, thereby considerably enhancing planned turbulence physics studies by providing a measurement of the k θ -spectrum of both electron temperature gradient (ETG) and ion temperature gradient (ITG) modes. Two approaches to generating the 693 GHz probe beam are under development: an optically-pumped far-infrared (FIR) laser that generates ~50 mW, and a compact gyrotron that can potentially generate in excess of 5 W. Large aperture optics collect radiation scattered from density fluctuations in the plasma core at 8 simultaneous scattering angles ranging from 2 to 15° corresponding to poloidal wavenumbers that extend to >40 cm -1 . Finally, steerable launch optics coupled with receiver optics mounted on a 5-axis receiver carriage allow the scattering volume to be placed radially from r/a = 0.3 out to the pedestal region (r/a ~ 0.99) and translated horizontally as needed to satisfy wavenumber matching.

47 OTHER INSTRUMENTATION↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and Tuning of a THz-Driven Electron Gun

We have developed a THz-driven field emission electron gun and beam characterization assembly. The two cell standing-wave gun operates in the pi mode at 110.08 GHz. It is designed to produce 360 keV electrons with 500 kW of input power supplied by a 110 GHz gyrotron. Multiple gun structures were electroformed in copper using a high precision diamond-turned mandrel. The field emission cathode is a rounded copper tip located in the first cell. The cavity resonances were mechanically tuned using azimuthal compression. This work will discuss details of the fabrication and tuning and present the results of low power measurements.

43 PARTICLE ACCELERATORS↗

ARPA-E PNDIODES "PN Junctions by Ion Implantation" Project (Final Report)

Electricity accounts for nearly 40% of the energy generated in the United States, of which 65% is lost to electrical system inefficiency before reaching end-use sectors. Power electronics will play a growing role in this distribution and end-use, with up to 80% of electricity estimated to pass through power electronics from generation to consumption by 2030. This gives technical improvements in power electronics enormous potential to drive efficiency gains throughout the U.S. economy. Current Si-based power architectures including MOSFETs and IGBTs are limited by high losses, low switching frequency, and poor high-temperature performance. Given the material properties of GaN, devices can exhibit a given turn-on resistance and breakdown voltage with a minute fraction of the area of a Si device—all with higher switching speeds. While n-type doping of III-nitrides has reached a high level of maturity and integration into commercialized products, p-type doping presents distinct challenges that requires continued research. The success of the next generation of GaN-based power devices depends in large part on the ability to form selective-area p-type regions, which can be accomplished by ion implantation of the prevailing acceptor dopant, Mg. This approach is relatively inexpensive and is a fab-ready processing step for creation of current-generation power electronic devices including BJTs, IGBTs, and diode rectifiers. However, ion implantation induces lattice damage and creates point defects within the material, which negatively impacts dopant activation annealing. These forms of damage may be removed by high-temperature annealing, however short annealing time and higher pressures are required to prevent decomposition of the material. We approach this challenge through an innovative combination of approaches toward obtaining high-conductivity p-type GaN. By the novel employment of a gyrotron, a microwave source that can be shaped into a highly localized beam to dissipate very high power in a semiconductor target, a wafer of GaN can be annealed in short (<2 s) ‘pulses’ at temperatures of 1450 °C (2640 °F) to achieve p-type activation without appreciable surface degradation. The p-type activation of Mg-implanted GaN can be further aided by co-implantation with N, believed to enhance the removal of point defects that compensate the acceptors dopant. Elevation to such high temperatures for even a short time induces degradation of GaN-to overcome, we have implemented additional measures to retain high-quality crystalline GaN while removing implant damage and activating Mg dopant. A bilayer cap of AlN is deposited by a combination of chemical and physical vapor deposition to protect the GaN surface. To prevent decomposition of GaN loss of N during annealing, a custom vessel—to contain pressurized N while allowing injection of microwave energy—is employed. By detailed study of the interaction of various measures that are implemented to protect the sample surface (GaN), activate the implanted dopants, and mitigate damage of the lattice heating damage during annealing, we are able to achieve p-type GaN and observe recovery of the crystal and removal of substantial density of defects created during the implantation process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Basement rock hybrid drilling

A system for monitoring and controlling downhole pressure of a well borehole relative to a lithostatic pressure of rock surrounding the borehole is provided. The system can include a millimeter wave drilling apparatus including a gyrotron configured to inject millimeter wave radiation energy into a borehole of a well via a waveguide configured for insertion into the borehole. The borehole can be formed via the millimeter wave drilling apparatus and having a downhole pressure monitored at a bottom of the well. The system can also include a compressor fluidically coupled to the borehole and configured to control the downhole pressure via a gas supplied into and/or received from the borehole. The compressor can be configured to control the downhole pressure relative to a lithostatic pressure determined for rock surrounding the well at the bottom of the well.

Araque, Carlos↗

Plasma heating technology

The operational environment for plasma heating systems presents unprecedented challenges for the success of magnetic fusion. This chapter discusses the current state of ion cyclotron and electron cyclotron heating systems and the research and development priorities needed to establish working solutions for these systems. While much progress has been made, there is much more work to be done to make fusion energy commercially viable. Research and development priorities include radiation-resistant structural and plasma facing materials, advanced manufacturing methods, new cooling methods, first-wall integrated actuators, improvements in power source efficiency, higher frequency gyrotrons, and improved overall system reliability.

Caughman, John↗

Final technical report

A new series of MW-class, RF loads were developed that can dissipate power levels exceeding 1.5 MW at frequencies from 28 GHz to 180 GHz. The new loads are designed to reflect less than 0.25% of the input power and operate continuously (CW). Stainless-steel and anodized aluminum versions were developed. The stainless steel version is designed to meet requirements for nuclear facilities, such as ITER, while the aluminum version is capable of power levels exceeding 2 MW CW. The aluminum version is also lighter and less expensive. This report describes the design activities during the program and the performance characteristics of the loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase I Final Repoert

Explore the source record for details and available documents.

gyrotron, fusion, electron cyclotron heating, plas↗