Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “graphite crystal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

K{sub α} x-ray imaging of laser-irradiated, limited-mass zirconium foils

X-ray fluorescence measurements to determine the effect of target heating on imaging efficiency, at a photon energy of 15.7 keV corresponding to the K{sub α} line of zirconium, have been carried out using limited-mass foils irradiated by the Texas Petawatt Laser. Zirconium foils that ranged in volume from 3000 × 3000 × 21 μm{sup 3} to 150 × 150 × 6 μm{sup 3} were irradiated with 100 J, 8 ps-long pulses and a mean intensity of 4 × 10{sup 19} W/cm{sup 2}. The K{sub α} emission was measured simultaneously using a highly ordered pyrolytic graphite crystal spectrometer and a curved quartz imaging crystal. The measured ratio of the integrated image signal to the integrated spectral signal was, within the experimental error, constant, indicating that the imaging efficiency's dependence on temperature is weak throughout the probed range. Based on our experience of target heating under similar conditions, we estimate a temperature of ∼200 eV for the smallest targets. The successful imaging of K{sub α} emission for temperatures this high represents an important proof of concept for Zr K{sub α} imaging. At these temperatures, the imaging of K{sub α} emission from lower-Z materials (such as Cu) is limited by temperature-dependent shifts in the K{sub α} emission energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic study of the hydrogen charging reaction on the graphite e in aqueous solution and in room temperature ionic liquid (RTIL)

Electrochemical impedance spectroscopy and other electrochemical methods were used to study the kinetics of hydrogen entry into porous, isotropic graphite and a single crystal graphite surfaces upon cathodic hydrogen charging and to calculate the hydrogen adsorption efficiencies. This model was first applied to graphite in an aqueous, alkaline solution, then in a room-temperature ionic liquid (RTIL), and, ultimately will be applied to FliNaK molten salt systems in future work. The results demonstrate that our model accurately describes the entry of hydrogen into graphite in harsh environments, which are important for the development of molten salt reactors (MSRs).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray laser resonator for the kilo-electron-volt range

We have designed, constructed, and tested an x-ray laser resonator operating in the hard x-ray, keV energy region. This ring x-ray laser cavity is formed by four highly oriented pyrolytic graphite crystals. The crystals are set at the Bragg angles that allow for the complete 360 Degree-Sign round trip of the 2.37 A, 5.23 keV L{sub {alpha}} line of neodymium. In addition, we also present experimental data of a similar ring laser resonator that utilizes the Cr K{sub {alpha}}, 5.41 keV, x-ray line to propagate through the four mirrors of the cavity. The specific properties of these x-ray laser resonator mirrors, including reflection losses and cavity arrangement, are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A micrographic and gravimetric study of intercalation and deintercalation of graphite fibers

Intercalation and deintercalation of Union Carbide P-100 graphite fibers with liquid and vaporous bromine was studied gravimetrically and microscopically. The mass of the bromine intercalated fibers was found to be 17 to 20 percent greater than their pristine counterpart. This variation decreased to 17 to 18 percent after heating in air for 3 days at 200 C and to 14.5 to 18 percent after 6 days of 260 C heating. The fiber length did not change throughout the experiment. The fiber diameter increased during intercalation and decreased slightly upon deintercalation but was not affected by heating to 260 C for 3 days in air. Comparing the mass and volume data to those with highly oriented pyrolitic graphite or natural single crystal graphite suggested the possibility that the intercalated P-100 fibers could be mostly stage 4.

Hung, C. C.↗

Effect of defocusing on picosecond laser-coupling into gold cones

Here, we show that defocusing of the laser in the interaction of a picosecond duration, 1.053 μm wavelength, high energy pulse with a cone-wire target does not significantly affect the laser energy coupling efficiency, but does result in a drop in the fast electron effective temperature. This may be beneficial for fast ignition, since not only were more electrons with lower energies seen in the experiment but also the lower prepulse intensity will reduce the amount of preplasma present on arrival of the main pulse, reducing the distance the hot electrons have to travel. We used the Vulcan Petawatt Laser at the Rutherford Appleton Laboratory and gold cone targets with approximately 1 mm long, 40 μm diameter copper wires attached to their tip. Diagnostics included a quartz crystal imager, a pair of highly oriented pyrolytic graphite crystal spectrometers and a calibrated CCD operating in the single photon counting regime, all of which looked at the copper K{sub α} emission from the wire. A short pulse optical probe, delayed 400 ps relative to the main pulse was employed to diagnose the extent of plasma expansion around the wire. A ray-tracing code modeled the change in intensity on the interior surface of the cone with laser defocusing. Using a model for the wire copper K{sub α} emission coupled to a hybrid Vlasov-Fokker-Planck code, we ran a series of simulations, holding the total energy in electrons constant whilst varying the electron temperature, which support the experimental conclusions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stellar crystal X-ray spectroscopy on OSO-8

The large-area graphite crystal X-ray spectrometer on the OSO-8 satellite is described, and its response to stellar line and continuum radiation is discussed. A high resolution X-ray spectrum of Sco X-1 obtained from a preliminary analysis of quick look data shows a strong, smooth continuum with an absence of emission or absorption features over the energy range 2.2 to 8 keV. Upper limits are set on narrow line emission from highly ionized states of S, Ca, and Fe.

Kestenbaum, H. L.↗

A novel von Hamos spectrometer for efficient X-ray emission spectroscopy in the laboratory

We present a novel, highly efficient von Hamos spectrometer for X-ray emission spectroscopy (XES) in the laboratory using highly annealed pyrolitic graphite crystals as the dispersive element. The spectrometer covers an energy range from 2.5 keV to 15 keV giving access to chemical speciation and information about the electronic configuration of 3d transition metals by means of the Kβ multiplet. XES spectra of Ti compounds are presented to demonstrate the speciation capabilities of the instrument. A spectral resolving power of E/ΔE = 2000 at 8 keV was achieved. Typical acquisition times range from 10 min for bulk material to hours for thin samples below 1 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Field Electron Emitter in the Form of Iridium Tip with Carbon Coating

The properties of an field electron emitter, the surface of which is obtained by the decomposition of benzene molecules on the iridium tip, have been studied. As a result, a graphite crystal is formed at the top of the tip. Resistance of molecules of residual gases to adsorption, as well as the possibility of localizing emission by adsorption and intercalation of alkali metal atoms are shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Qualification of a high-efficiency, gated spectrometer for x-ray Thomson scattering on the National Ignition Facility

We have designed, built, and successfully fielded a highly efficient and gated Bragg crystal spectrometer for x-ray Thomson scattering measurements on the National Ignition Facility (NIF). It utilizes a cylindrically curved Highly Oriented Pyrolytic Graphite crystal. Its spectral range of 7.4–10 keV is optimized for scattering experiments using a Zn He-α x-ray probe at 9.0 keV or Mo K-shell line emission around 18 keV in second diffraction order. The spectrometer has been designed as a diagnostic instrument manipulator-based instrument for the NIF target chamber at the Lawrence Livermore National Laboratory, USA. Here, we report on details of the spectrometer snout, its novel debris shield configuration and an in situ spectral calibration experiment with a Brass foil target, which demonstrated a spectral resolution of E/ΔE = 220 at 9.8 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusing of millijoule picosecond K{sub a}lpha radiation from 100 TW laser-solid interaction

A calibrated x-ray spectrometer was used to characterize an intense 4.5 keV K{sub a}lpha source. Generated from the interaction of 30 J-320 fs laser pulses focused on 25 mum thick Ti foils, the conversion efficiency into Ti K{sub a}lpha line is estimated to (9+-6)x10{sup -5}. Highly efficient collection, monochromatization and focusing were achieved using an ellipsoidally bent highly oriented pyrolytic graphite crystal. The measured 700 mum full width half maximum (FWHM) focal spot leads to a fluence of (3.0+-2.1) mJ/cm{sup 2} hence paving the way to the study of intense x-ray pulse interaction with matter as demonstrated by a first simple experiment.

36 MATERIALS SCIENCE↗

Focusing crystal polarimeter designed for X-ray polarimetry - Construction and performance

A method for the construction of a graphite crystal polarimeter designed for measuring linear polarization of X-ray continuum sources is described. The dependence of reflected intensity upon the polarization direction of the incident beam at Bragg angles of 45 deg is used to measure the polarization. The particular instrument described was designed for a satellite X-ray polarimeter. By using a focusing parabolic surface instead of a nonfocusing flat crystal, the signal-to-background ratio is improved by a factor of 30 as compared to a flat crystal polarimeter of the same effective area. The focusing properties of the reflector were tested both optically and with X-rays. The performance of the instrument as a polarimeter was tested with a continuum X-ray source of small polarization, which was independently measured by a single flat crystal polarimeter. The agreement between the two measurements is excellent, indicating that the instrument can measure polarizations as low as 0.3%.

Toraskar, J. R.↗

Coupled field-structural analysis of HGTR fuel brick using ABAQUS

High-temperature, gas-cooled reactors (HTGRs) are usually helium-gas cooled, with a graphite core that can operate at reactor outlet temperatures much higher than can conventional light water reactors. In HTGRs, graphite components moderate and reflect neutrons. During reactor operation, high temperature and high irradiation cause damage to the graphite crystal and grains and create other defects. This cumulative structural damage during the reactor lifetime leads to changes in graphite properties, which can alter the ability to support the designed loads. The aim of the present research is to develop a finite-element code using commercially available ABAQUS software for the structural integrity analysis of graphite core components under extreme temperature and irradiation conditions. In addition, the Reactor Geometry Generator tool-kit, developed at Argonne National Laboratory, is used to generate finite-element mesh for complex geometries such as fuel bricks with multiple pin holes and coolant flow channels. This paper presents the proposed concept and discusses results of stress analysis simulations of a fuel block with H-451 grade material properties. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Carbon-rich aggregates in type 3 ordinary chondrites - Characterization, origins, and thermal history

Carbon-rich aggregates from three type 3.4-3.6 ordinary chondrites and two chondritic clasts have been characterized in detail, using TEM techniques. The aggregates in all the meteorites studied range in size from 5-1000 microns and consist of a fine scale intergrowth of poorly graphitized carbon, amorphous carbon, Fe,Ni metal, and minor chromite. Contrary to previous reports, well-crystallized graphite and magnetite are absent. The association of Fe,Ni metal and carbonaceous material suggests that the original carbonaceous material may have formed by Fischer-Tropsch (FT) type reactions at low temperatures (less than 400 K), possibly in the solar nebula. This carbonaceous material probably consisted of a complex mixture of hydrocarbons, kerogen-like material, and other complex organic molecules. The aggregates were subsequently accreted onto the ordinary chondrite parent bodies and underwent planetary thermal processing which resulted in the catalytic graphitization of hydrocarbons, in the presence of Fe,Ni metal, to produce poorly graphitized carbon. None of the meteorites studied experienced temperatures sufficiently high to produce crystalline, ordered graphite. Using the empirical geothermometer of Rietmeijer and Mackinnon (1985), the measured d(002) spacings of poorly graphitized carbon show that graphitization occurred at temperatures between 300 and 450 C. This range of temperatures is significantly lower than the generally quoted metamorphic temperatures for type 3.4-3.6 ordinary chondrites (about 450-500 C).

Brearley, Adrian J.↗

OSO-8 X-ray polarimeter and Bragg crystal spectrometer observations

Results are discussed for observations of the Crab Nebula, Cyg X-1, and Cyg X-2 with the focusing mosaic graphite crystal X-ray polarimeter aboard OSO-8 as well as for observations of A0620-00 with the Bragg crystal spectrometer aboard the same satellite. The observed X-ray polarization of the Crab Nebula is shown to be in agreement with a previous measurement of the optical polarization and to confirm with very high confidence the earlier conclusion that the X-ray emission occurs by the synchrotron process. No evidence is found for polarization of X-rays from Cyg X-1, but a preliminary result of 4.8% + or 1.0% polarization at an energy of 2.6 keV and a position angle of 141.7 + or - 6.6 deg is reported for Cyg X-2. It is noted that this value is within the range expected for accretion disks. The spectrometry of A0620-00 yielded a continuous spectrum that can be accurately fitted with a thermal bremsstrahlung spectrum at a temperature of 15 million K.

Novick, R.↗

On the performance of the scattering and crystal polarimeters for the Spectrum-X-Gamma mission

X-ray scattering from a lithium disk and Bragg reflection from a mosaic graphite crystal can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. The sensitivity is enhanced if the polarimeters are placed at the focus of an X-ray telescope. Such devices form two of the components of the Stellar X-ray Polarimeter experiment scheduled to fly on the Spectrum-X-Gamma mission. The expected on-axis performance of the two components is described based on detailed Monte Carlo simulations. The polarimetry experiment is expected to provide sensitive measurements of linear polarization for many cosmic X-ray sources. The nature and utility of such observations is described for pulsing X-ray sources such as the Crab pulsar and Her X-1.

Elsner, R. F.↗

Graphite revisited

Laboratory measurements are used to constrain the dielectric tensor for graphite, from microwave to X-ray frequencies. The dielectric tensor is strongly anisotropic even at X-ray energies. The discrete dipole approximation is employed for accurate calculations of absorption and scattering by single-crystal graphite spheres and spheroids. For randomly oriented single-crystal grains, the so-called 1/3--2/3 approximation for calculating absorption and scattering cross sections is exact in the limit a/λ→0 and provides better than ∼10% accuracy in the optical and UV even when a/λ is not small, but becomes increasingly inaccurate at infrared wavelengths, with errors as large as ∼40% at λ=10 μm. For turbostratic graphite grains, the Bruggeman and Maxwell Garnett treatments yield similar cross sections in the optical and ultraviolet, but diverge in the infrared, with predicted cross sections differing by over an order of magnitude in the far-infrared. It is argued that the Maxwell Garnett estimate is likely to be more realistic, and is recommended. The out-of-plane lattice resonance of graphite near 11.5 μm may be observable in absorption with the MIRI spectrograph on James Webb Space Telescope. Aligned graphite grains, if present in the interstellar medium, could produce polarized X-ray absorption and polarized X-ray scattering near the carbon K edge.

79 ASTRONOMY AND ASTROPHYSICS↗

Extended X-ray observations of Scorpius X-1 with a Bragg crystal spectrometer

Observations covering multiple orbital periods of the X-ray source Sco X-1 were carried out in 1975 and 1976 with the graphite crystal spectrometer aboard OSO 8. Time-averaged continuum spectra are featureless and are reasonably well described in terms of a Comptonized thermal bremsstrahlung spectrum in which kT is about 1.5-2 keV and in which the number of electron scatterings that each photon is assumed to have undergone is of the order of 100. Line limits, typically with equivalent widths of a few electron volts, are established for important emission lines of Si XIII, Si XIV, S XV, S XVI, and Fe XXV as a function of binary phase.

Long, K. S.↗