Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “glass formulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Glass Formulation for Next Generation Cold Crucible Induction Melter

Transformational melter technologies are being considered to support mission acceleration within the U.S. Department of Energy (DOE) complex. New glass formulations are required to take full advantage of the next generation melters, for example, the cold crucible induction melter (CCIM). The key advantage of CCIM technology over current reference technologies is its capability to provide higher processing temperatures, which can lead to an increased waste throughput rate by achieving higher waste loadings and by increasing the feed processing rate. Various waste compositions within the DOE complex were evaluated to determine their potential for successfully demonstrating the unique advantages of the CCIM technology. Glass formulations that satisfy a set of constraints for product quality and assumed CCIM processing conditions were developed for two Hanford waste streams, AZ-101 high-level waste (HLW) and AN-105 low-activity waste (LAW). Three glasses selected for AZ-101 HLW have waste loadings of 40, 42.5, and 45 wt%. The 45-wt% waste loading corresponds to a 22% increase from 37 wt%, which is the maximum expected waste loading based on the current reference formulation. One glass selected for AN-105 LAW has a waste loading of 31.3 wt% at 24 wt% Na2O in glass, which is a 14% increase from the current reference formulation maximum of 21 wt% Na2O. These four glasses are planned for scaled melter tests for initial demonstration of the CCIM technologies for Hanford wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Silicate Based Glass Formulations for Immobilization of U.S. Defense Wastes Using Cold Crucible Induction Melters

The cold crucible induction melter (CCIM) is an alternative technology to the currently deployed liquid-fed, ceramic-lined, Joule-heated melter for immobilizing of U.S. tank waste generated from defense related reprocessing. In order to accurately evaluate the potential benefits of deploying a CCIM, glasses must be developed specifically for that melting technology. Related glass formulation efforts have been conducted since the 1990s including a recent study that is first documented in this report. The purpose of this report is to summarize the silicate base glass formulation efforts for CCIM testing of U.S. tank wastes. Summaries of phosphate based glass formulation and phosphate and silicate based CCIM demonstration tests are reported separately (Day and Ray 2013 and Marra 2013, respectively). Combined these three reports summarize the current state of knowledge related to waste form development and process testing of CCIM technology for U.S. tank wastes.

Cold crucible induction melter↗

LAW Glass Formulation to Support Melter Runs with Simulants

The major objective of this work was to prepare and characterize glass formulations in order to develop and select formulations that are compliant with contractual and processing requirements to support melter tests with each of the LAW Sub-Envelopes. Glasses that cover composition ranges of interest were prepared and characterized to ensure that selected glass compositions can tolerate expected composition variations resulting from process errors without adversely affecting processing characteristics or product quality. Glass compositions that are expected to result during transitions from one waste stream to another were also prepared and characterized. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, and identification of glass formulation issues with respect to contract specifications and processing requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Design Using Machine Learning Property Models with Prediction Uncertainties: Nuclear Waste Glass Formulation

The United States Department of Energy is responsible for managing the legacy nuclear waste stored in underground tanks at the Hanford Site. The waste will be separately vitrified as low-activity waste and high-level waste fractions. Waste glass formulation algorithms have been traditionally developed using partial quadratic mixture property-composition models. Recently, machine learning (ML) techniques have been used to predict glass properties and discover new glass materials for nuclear waste vitrification, and these advancements can be utilized to improve waste glass composition design. In this proof-of-principle study, ML algorithms such as Gaussian process regression (GPR) were used to interpolate glass properties (e.g., viscosity, electrical conductivity, chemical durability). After selecting appropriate sets of GPR hyper-parameters for each property, an optimization program was developed to formulate glass compositions to maximize waste loading while simultaneously satisfying property within constraints. The results of the ML-based waste loadings and glass compositions were compared to those obtained using the traditional methods. Comparing to the previous glass design framework, the ML-based optimization methods offer improved glass designs and a streamlined approach to generation of optimally designed data and near real-time updates.

glass formulation, machine learning, constraints, ↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION: KT05- AND KT06-SERIES GLASS COMPOSITIONS

This report is the second in a series of studies of the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. The KT05-series glasses were selected, fabricated, and characterized to further study glass compositions where iron titanate crystals had been previously found to form. The intent was to better understand the mechanisms and compositions that favored the formation of crystals containing titanium. Formation of these crystalline phases was confirmed. Increased Na{sub 2}O concentrations had little if any impact on reducing the propensity for the formation of the iron titanate crystalline phases. Other physical properties of these glasses were not measured since the intent was to focus on crystallization. Additional studies are suggested to investigate the potential impacts of Al{sub 2}O{sub 3} and K{sub 2}O on crystallization in glasses with high TiO{sub 2} concentrations. The KT06-series glasses were selected, fabricated, and characterized to further study glass compositions that, while broader than the current projections for DWPF feeds with SCIX material, are potential candidates for future processing (i.e., the compositions are acceptable for processing by the Product Composition Control System (PCCS) with the exception of the current TiO{sub 2} concentration constraint). The chemical compositions of these glasses matched well with the target values. The chemical durabilities of all the glasses were acceptable relative to the Environmental Assessment (EA) benchmark. Minor crystallization was identified in some of the slowly cooled glasses, although this crystallization did not impact chemical durability. Several of the KT06-series compositions had durability values that, while acceptable, were not accurately predicted by the current durability models. It was shown that for these high TiO{sub 2} concentration glasses, relatively high Fe{sub 2}O{sub 3} concentrations combined with relatively high Al{sub 2}O{sub 3} concentrations led to durabilities that were unpredictable. Several of the KT06-series glasses also had measured viscosity values that were not well predicted by the current model. A statistical partitioning routine showed that the measured viscosities became unpredictable by the current model when the Fe{sub 2}O{sub 3} concentration in the glasses was less than about 8.2 wt % at the elevated TiO{sub 2} concentrations. The current durability and viscosity models will have to be further evaluated should compositions in these regions become necessary for DWPF processing. Overall, the results presented for the KT06-series glasses show that TiO{sub 2} from the SCIX streams can be incorporated into DWPF-type glasses at concentrations of 6 wt % (in glass) without any detrimental impacts on crystallization or chemical durability that are of practical importance. The measured values for chemical durability and viscosity were acceptable for processing; however, not all of the values were predictable by the current PCCS models. Since the compositions selected for the KT06-series glasses were outside the current projections for DWPF processing with the SCIX streams (in terms of waste components other than TiO{sub 2}), these results help identify compositional regions that, if necessary for processing, would require modifications to the current models. Additional experiments are currently underway. Once completed, all of the measured data will be reviewed and compared to model predictions to better determine whether the validation range of the DWPF process control models can be confidently extended, or whether refitting of the models will be necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced HLW glass formulations for the waste treatment and immobilization plant

Current estimates and glass formulation efforts are conservative vis-a-vis achievable waste loadings. These formulations have been specified to ensure that glasses are homogenous, contain essentially no crystalline phases, are processable in joule-heated, ceramic-lined melters and meet WTP Contract terms. The WTP's overall mission will require the immobilization of tank waste compositions that are dominated by mixtures of aluminum, chromium, bismuth, iron, phosphorous, zirconium, and sulfur compounds as waste-limiting components. Glass compositions for these waste mixtures have been developed based upon previous experience and current glass property models. DOE has a testing program to develop and characterize HLW glasses with higher waste loadings. This work has demonstrated the feasibility of increases in waste loading from 25 wt% to 33-50 wt% (based on oxide loading) in the glass depending on the waste stream. It is expected these higher waste loading glasses will reduce the HLW canister production requirement by 25% or more. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE IMPACT OF THE MCU LIFE EXTENSION SOLVENT ON DWPF GLASS FORMULATION EFFORTS

As a part of the Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) Life Extension Project, a next generation solvent (NG-CSSX), a new strip acid, and modified monosodium titanate (mMST) will be deployed. The strip acid will be changed from dilute nitric acid to dilute boric acid (0.01 M). Because of these changes, experimental testing with the next generation solvent and mMST is required to determine the impact of these changes in 512-S operations as well as Chemical Process Cell (CPC), Defense Waste Processing Facility (DWPF) glass formulation activities, and melter operations at DWPF. To support programmatic objectives, the downstream impacts of the boric acid strip effluent (SE) to the glass formulation activities and melter operations are considered in this study. More specifically, the impacts of boric acid additions to the projected SB7b operating windows, potential impacts to frit production temperatures, and the potential impact of boron volatility are evaluated. Although various boric acid molarities have been reported and discussed, the baseline flowsheet used to support this assessment was 0.01M boric acid. The results of the paper study assessment indicate that Frit 418 and Frit 418-7D are robust to the implementation of the 0.01M boric acid SE into the SB7b flowsheet (sludge-only or ARP-added). More specifically, the projected operating windows for the nominal SB7b projections remain essentially constant (i.e., 25-43 or 25-44% waste loading (WL)) regardless of the flowsheet options (sludge-only, ARP added, and/or the presence of the new SE). These results indicate that even if SE is not transferred to the Sludge Receipt and Adjustment Tank (SRAT), there would be no need to add boric acid (from a trim tank) to compositionally compensate for the absence of the boric acid SE in either a sludge-only or ARP-added SB7b flowsheet. With respect to boron volatility, the Measurement Acceptability Region (MAR) assessments also suggest that Slurry Mix Evaporator (SME) acceptability decisions would not be different assuming either 100% of the B{sub 2}O{sub 3} from the SE were retained or volatilized. More specifically, the 0.84 wt% B{sub 2}O{sub 3} in the SE is so minor that its presence in the SME analysis does not influence SME acceptability decisions. In fact, using the 100% retention and 100% volatilization composition projections, only minor differences in the predicted properties of the glass product occur with all of the glasses being acceptable over a WL interval of 32-42%. Based on the 0.01M boric acid flowsheet, there is very little difference between Frit 418 and Frit 418-7D (a frit that was compositionally altered to account for the 0.84 wt% B{sub 2}O{sub 3} in the SE) with respect to melt temperature. In fact, when one evaluates the composition of Frit 418-7D, it lies within the current Frit 418 vendor specifications and therefore could have been produced by the vendor targeting the nominal composition of Frit 418.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in the Glass Formulations for the Hanford Tank Waste Treatment and Immobilization Plant

The Department of Energy-Office of River Protection (DOE-ORP) is constructing the Hanford Tank Waste Treatment and Immobilization Plant (WTP) to treat radioactive waste currently stored in underground tanks at the Hanford site in Washington. The WTP that is being designed and constructed by a team led by Bechtel National, Inc. (BNI) will separate the tank waste into High Level Waste (HLW) and Low Activity Waste (LAW) fractions with the majority of the mass (~90%) directed to LAW and most of the activity (>95%) directed to HLW. The pretreatment process, envisioned in the baseline, involves the dissolution of aluminum-bearing solids so as to allow the aluminum salts to be processed through the cesium ion exchange and report to the LAW Facility. There is an oxidative leaching process to affect a similar outcome for chromium-bearing wastes. Both of these unit operations were advanced to accommodate shortcomings in glass formulation for HLW inventories. A by-product of this are a series of technical challenges placed upon materials selected for the processing vessels. The advances in glass formulation play a role in revisiting the flow sheet for the WTP and hence, the unit operations that were being imposed by minimal waste loading requirements set forth in the contract for the design and construction of the plant. Another significant consideration to the most recent revision of the glass models are the impacts on resolution of technical questions associated with current efforts for design completion.

Kruger, Albert A.↗

Advances in the glass formulations for the Hanford Tank Waste Treatment and Immobilization Plant - 15053

The Department of Energy-Office of River Protection (DOE-ORP) is constructing the Hanford Tank Waste Treatment and Immobilization Plant (WTP) to treat radioactive waste currently stored in underground tanks at the Hanford site in Washington. The WTP that is being designed and constructed by a team led by Bechtel National, Inc. (BNI) will separate the tank waste into High Level Waste (HLW) and Low Activity Waste (LAW) fractions with the majority of the mass (∼90%) directed to LAW and most of the activity (>95%) directed to HLW. The pretreatment process, envisioned in the baseline, involves the dissolution of aluminum-bearing solids so as to allow the aluminum salts to be processed through the cesium ion exchange and report to the LAW Facility. There is an oxidative leaching process to affect a similar outcome for chromium-bearing wastes. Both of these unit operations were advanced to accommodate shortcomings in glass formulation for HLW inventories. A by-product of this are a series of technical challenges placed upon materials selected for the processing vessels. The advances in glass formulation play a role in revisiting the flow sheet for the WTP and hence, the unit operations that were being imposed by minimal waste loading requirements set forth in the contract for the design and construction of the plant. Another significant consideration to the most recent revision of the glass models are the impacts on resolution of technical questions associated with current efforts for design completion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DWPF FLOWSHEET STUDIES WITH SIMULANT TO DETERMINE THE IMPACT OF NEXT GENERATION SOLVENT ON THE CPC PROCESS AND GLASS FORMULATION

As a part of the Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) Life Extension Project, a next generation solvent (NGS), a new strip acid, and modified monosodium titanate (mMST) will be deployed. The NGS is comprised of four components: 0.050 M MaxCalix (extractant), 0.50 M Cs-7SB (modifier), 0.003 M guanidine-LIX-79, with the balance ({approx}74 wt%) being Isopar{reg_sign} L. The strip acid will be changed from dilute nitric acid to dilute boric acid (0.01 M). Because of these changes, experimental testing with the next generation solvent and mMST was required to determine the impact of these changes in 512-S and Defense Waste Processing Facility (DWPF) operations, as well as Chemical Process Cell (CPC), glass formulation activities, and melter operations. Because of these changes, experimental testing with the next generation solvent and mMST is required to determine the impact of these changes. A Technical Task Request (TTR) was issued to support the assessments of the impact of the next generation solvent and mMST on the downstream DWPF flowsheet unit. The TTR identified five tasks to be investigated: (1) CPC Flowsheet Demonstration for NGS; (2) Solvent Stability for DWPF CPC Conditions; (3) Glass Formulation Studies; (4) Boron Volatility and Melt Rate; and (5) CPC Flowsheet Demonstration for mMST.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass formulation and lab-scale testing of glasses designed for in-can Melter and in-container Vitrification of high-assay low-enriched uranium aqueous polishing Raffinate waste

Glasses were designed for processing a nuclear waste from aqueous polishing of high-assay low-enriched uranium using either In-Can Melter (ICM) or GeoMelt® In-Container Vitrification™ (ICV) technologies, which operate at temperatures of T p ≤ 1100 °C and T p ≤ 1450 °C, respectively. Due to the different operating conditions, the melt and glass properties were optimized differently for each technology. Each glass was designed to optimize for maximum waste loading while simultaneously satisfying processing (e.g., crystallization, viscosity, and conductivity) and product quality (e.g., durability, hazard characteristic, and crystal content) constraints. Here, the raffinate waste contains high nitric acid (4 M) and low total solids (9 g·L -1 ) concentrations. Feed preparation processes were tested to facilitate concentration and nitrate destruction/removal while controlling redox of the melter feed. A successful feed process including sugar addition and spray-drying was performed to generate an adequate melter feed for ICV processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION: KT08, KT09, AND KT10-SERIES GLASS COMPOSITIONS

This report is the fourth in a series of studies of the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. MST from the Salt Waste Processing Facility (SWPF) is also considered in the study. The KT08-series of glasses was designed to evaluate any impacts of the inclusion of uranium and thorium in glasses containing the SCIX components. The KT09-series of glasses was designed to study the effect of increasing Al{sub 2}O{sub 3} and K{sub 2}O concentrations on the propensity for crystallization of titanium containing phases in high TiO{sub 2} concentration glasses. Earlier work on the KT05-series glasses recommended that the impact of these two components be studied further. Increased Al{sub 2}O{sub 3} concentrations have been shown to improve the properties and performance of high waste loading glasses, and K{sub 2}O has been reported to improve the retention of TiO{sub 2} in silicate glasses. The KT10-series of compositions was designed to evaluate any impacts of the SCIX components at concentrations 50% higher than currently projected.a The glasses were fabricated in the laboratory and characterized to identify crystallization, to verify chemical compositions, to measure viscosity, and to measure durability. Liquidus temperature measurements for the KT10-series glasses are underway and will be reported separately. All but one of the KT08-series glasses were found to be amorphous by X-ray diffraction (XRD). One of the slowly cooled glasses contained a small amount of trevorite, which had no practical impact on the durability of the glass and is typically found in DWPF-type glasses. The measured Product Consistency Test (PCT) responses for the KT08-series glasses are well predicted by the DWPF models. The viscosities of the KT08-series glasses were generally well predicted by the DWPF model. No unexpected issues were encountered when uranium and thorium were added to the glasses with SCIX components. Increased Al{sub 2}O{sub 3} concentrations were not successful in preventing the formation of iron titanate crystals in the KT09-series glasses. Increased K{sub 2}O concentrations were successful in hindering the formation of iron titanates in some of the glasses after the canister centerline cooled (CCC) heat treatment. However, this result did not apply to all of the CCC versions of the glasses, indicating a compositional dependence of this effect. In addition, high concentrations of K{sub 2}O have been shown to hinder the ability of the DWPF durability and viscosity models to predict the performance of these glasses. The usefulness of increased K{sub 2}O concentrations in preventing the formation of iron titanates may therefore be limited. Further characterization was not performed for the KT09-series glasses since the type of crystallization formed was the characteristic of interest for these compositions. All of the KT10-series glasses were XRD amorphous, regardless of heat treatment. Chemical composition measurements showed that the glasses met the targeted concentrations for each oxide. In general, the measured PCT responses of the KT10-series glasses were well predicted by the DWPF models. The measured, normalized release values for silicon for some of the glasses fell above the 95% confidence interval for the predicted values; however, the PCT responses for these glasses remain considerably lower than that of the benchmark Environmental Assessment (EA) glass. The viscosities of the KT10-series glasses were generally well predicted by the DWPF model. The next step in this study will be to compile all of the data developed and further compare the measured properties and performance with those predicted by the current DWPF Product Composition Control System (PCCS) models. Recommendations will then be made as to which models, if any, may need to be modified in order to accommodate the material from SCIX into DWPF glass production.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in Glass Formulations for Hanford High-Aluminum, High-Iron and Enhanced Sulphate Management in HLW Streams - 13000

The current estimates and glass formulation efforts have been conservative in terms of achievable waste loadings. These formulations have been specified to ensure that the glasses are homogenous, contain essentially no crystalline phases, are processable in joule-heated, ceramic-lined melters and meet Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract terms. The WTP's overall mission will require the immobilization of tank waste compositions that are dominated by mixtures of aluminum (Al), chromium (Cr), bismuth (Bi), iron (Fe), phosphorous (P), zirconium (Zr), and sulphur (S) compounds as waste-limiting components. Glass compositions for these waste mixtures have been developed based upon previous experience and current glass property models. Recently, DOE has initiated a testing program to develop and characterize HLW glasses with higher waste loadings and higher throughput efficiencies. Results of this work have demonstrated the feasibility of increases in waste loading from about 25 wt% to 33-50 wt% (based on oxide loading) in the glass depending on the waste stream. In view of the importance of aluminum limited waste streams at Hanford (and also Savannah River), the ability to achieve high waste loadings without adversely impacting melt rates has the potential for enormous cost savings from reductions in canister count and the potential for schedule acceleration. Consequently, the potential return on the investment made in the development of these enhancements is extremely favorable. Glass composition development for one of the latest Hanford HLW projected compositions with sulphate concentrations high enough to limit waste loading have been successfully tested and show tolerance for previously unreported tolerance for sulphate. Though a significant increase in waste loading for high-iron wastes has been achieved, the magnitude of the increase is not as substantial as those achieved for high-aluminum, high-chromium, high-bismuth or sulphur. Waste processing rate increases for high-iron streams as a combined effect of higher waste loadings and higher melt rates resulting from new formulations have been achieved. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in Glass Formulations for Hanford High-Alumimum, High-Iron and Enhanced Sulphate Management in HLW Streams - 13000

The current estimates and glass formulation efforts have been conservative in terms of achievable waste loadings. These formulations have been specified to ensure that the glasses are homogenous, contain essentially no crystalline phases, are processable in joule-heated, ceramic-lined melters and meet Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract terms. The WTP?s overall mission will require the immobilization of tank waste compositions that are dominated by mixtures of aluminum (Al), chromium (Cr), bismuth (Bi), iron (Fe), phosphorous (P), zirconium (Zr), and sulphur (S) compounds as waste-limiting components. Glass compositions for these waste mixtures have been developed based upon previous experience and current glass property models. Recently, DOE has initiated a testing program to develop and characterize HLW glasses with higher waste loadings and higher throughput efficiencies. Results of this work have demonstrated the feasibility of increases in waste loading from about 25 wt% to 33-50 wt% (based on oxide loading) in the glass depending on the waste stream. In view of the importance of aluminum limited waste streams at Hanford (and also Savannah River), the ability to achieve high waste loadings without adversely impacting melt rates has the potential for enormous cost savings from reductions in canister count and the potential for schedule acceleration. Consequently, the potential return on the investment made in the development of these enhancements is extremely favorable. Glass composition development for one of the latest Hanford HLW projected compositions with sulphate concentrations high enough to limit waste loading have been successfully tested and show tolerance for previously unreported tolerance for sulphate. Though a significant increase in waste loading for high-iron wastes has been achieved, the magnitude of the increase is not as substantial as those achieved for high-aluminum, high-chromium, high-bismuth or sulphur. Waste processing rate increases for high-iron streams as a combined effect of higher waste loadings and higher melt rates resulting from new formulations have been achieved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Sulfate Management in HLW Glass Formulations

The present report describes a series of small-scale crucible tests to determine sulfate solubility in HLW glasses, tests to assess the effect of compositional changes on sulfate solubility, and small-scale meIter tests to determine maximum acceptable sulfate loadings in HLW feeds to the meIter. The work was performed in accordance with the Test Plan for this work and the ORP contract. Glasses produced in previous melter tests using WTP and ORP waste and glass compositions were tested in the present work to determine sulfur solubility. In parallel, a glass formulation was developed for a previously untested HLW composition with one of the highest projected sulfate concentrations; that formulation was subsequently processed on the DM10 melter system at successively higher waste loadings to determine the maximum waste loading. Tests were also conducted on the DM10 on several HLW formulations which had been previously subjected to crucible-scale sulfur solubility testing; these formulations were selected based on sulfur solubility information for HLW glasses that was compiled in a previous report to WTP; similar information for LAW glasses was compiled in a report to ORP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GLASS FORMULATION FOR THE HANFORD TANK WASTE TREATMENT AND IMMOBILIZATION PLANT (WTP)

A computational method for formulating Hanford HLW glasses was developed that is based on empirical glass composition-property models, accounts for all associated uncertainties, and can be solved in Excel{sup R} in minutes. Calculations for all waste form processing and compliance requirements included. Limited experimental validation performed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SUMMARY REPORT ON POTENTIAL IMPACTS OF SMALL COLUMN ION EXCHANGE ON DWPF GLASS FORMULATION

This report summarizes a large amount of experimental work completed to identify the potential impacts of material from Small Column Ion Exchange (SCIX) on glass formulation at the Defense Waste Processing Facility (DWPF). The results show no significant issues with the predicted values of chemical durability and viscosity using the current Product Composition Control System (PCCS) models when the SCIX components are added to projected DWPF glass compositions. No modifications to the viscosity and durability models appear to be necessary at this time in order to incorporate the SCIX streams at DWPF. It is recommended that the Savannah River National Laboratory (SRNL) continue to verify the durability and viscosity models as the projected compositions for DWPF processing evolve. It is also recommended that the data generated thus far be reviewed and a determination be made as to how best to extend the validation ranges of the durability and viscosity models. The liquidus temperatures for the experimental glasses are also reported and discussed in this report. The results show that the measured or estimated (based on measured data) liquidus temperature values for the glasses with SCIX components added are consistently higher than those predicted by the current model. Therefore, the PCCS liquidus temperature model will need to be modified in order to incorporate the SCIX streams at DWPF. It is recommended that SRNL carry out full measurements of the liquidus temperatures for those KT-series glasses where estimates have been made. These data should then be used to support an evaluation of whether a refitting of the liquidus temperature model coefficients will be sufficient to correctly predict the liquidus temperature of glasses containing the SCIX components (particularly higher TiO{sub 2} concentrations), or whether additional modifications to the model are required. While there are prediction issues with the current liquidus temperature model, they are not at this time expected to hamper the incorporation of SCIX streams at DWPF. The estimated liquidus temperatures, while higher than the model predicted values, remain below the current DWPF limit of 1050 C for most of the study glasses. Note that the properties and performance of the glasses in this study are highly dependent on glass composition. Therefore, should significant changes be made to the projected compositions or processing rates for SCIX or DWPF, many of the assessments and experiments may have to be revisited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗