Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Vacuum ultraviolet light source utilizing rare gas scintillation amplification sustained by photon positive feedback

A source of light in the vacuum ultraviolet (VUV) spectral region includes a reflective UV-sensitive photocathode supported in spaced parallel relationship with a mesh electrode within a rare gas at low pressure. A high positive potential applied to the mesh electrode creates an electric field which causes drifting of free electrons occurring between the electrodes and producing continuous VUV light output by electric field-driven scintillation amplification sustained by positive photon feedback mediated by photoemission from the photocathode. In one embodiment the lamp emits a narrow-band continuum peaked at 175 nm.

Aprile, Elena↗

Hybrid gas scintillation proportional counter/phoswich detector for hard X-ray astronomy

A concept is presented for a balloon-borne imaging hybrid proportional counter/phoswich detector of medium to hard X-rays. The phoswich would be optically coupled to the exit window of the proportional counter, and both detectors would use a common position-sensitive readout. It is anticipated that such a detector could combine the good energy and position resolution and excellent background rejection ability of the proportional counter for incident photon energies less than 100 keV with the extended response of the phoswich for higher energies. The phoswich could also be used to reject Compton scattering events in the proportional counter. This detector concept is studied using numerical simulations of a 400 sq cm square prototype detector. Results from this simulation indicate that current levels of proportional counter and phoswich performance are attainable at small cost in quantum efficiency, compared to a bare phoswich detector.

Grindlay, Jonathan E.↗

A broad band X-ray imaging spectrophotometer for astrophysical studies

A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

Lum, Kenneth S. K.↗

Spectroscopy in X-ray astronomy

Detailed features in cosmic X-ray sources and their associated temporal variation over a wide energy range were studied. Excess emission and absorption at approximately 6 to 7 kiloelectron volts in the spectra of supernova remnants, binary X-ray sources, and clusters of galaxies were observed. A gas scintillation proportional counter (GSPC) will be used as the detector system. In the gas scintillator the principal limitation is due to the statistics of the initial ionization process only.

Andresen, R.↗

For the detection of subkiloelectron-volt X-rays

A large-area, imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1-micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. Over a sensitive area of 21 sq cm, the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

A Measurement of the Energy Spectra of Cosmic Rays from 20 to 1000 GeV Per Amu

The design features and operational performance from the test flight of the fourth generation of spherical geometry cosmic ray detectors developed at Bristol University (Bristol University Gas Scintillator 4 - BUGS-4) are presented. The flight from Ft. Sumner (NM) in Sept. 1993 was the premier flight of a large (1m radius) spherical drift chamber which also gave gas scintillation and Cerenkov signals. The combinations of this chamber with one gas and two solid Cerenkov radiators lead to a large aperture factor (4.5 m2sr), but low (approximately 3.5 g/sq cm) instrument mass over the energy sensitive range 1 to several hundred GeV/a. Moreover, one simple timing measurement determined the impact parameter which provided a trajectory (path length) correction for all detector elements. This innovative and efficient design will be of interest to experimental groups engaged in studies of energetic charged particles. Although there were technical problems on the flight, which were compounded by the total destruction of BUGS-4 by fire while landing in Oklahoma, there was a period of stable operation during which the instrument was exposed at float altitude (approximately 125,000 ft.) to high energy cosmic rays. We present the performance of the instrument as determined from the analysis of these data and an appraisal of its novel design features. Suggestions for design improvements in a future instrument are made.

Gregory, J. C.↗

Ariel 6 measurements of ultra-heavy cosmic ray fluxes in the region 34 or = Z or = 48

The Ariel VI satellite was launched by NASA on a Scout rocket on 3rd June 1979 from Wallops Island, Virginia, USA, into a near circular 625 km orbit inclined at 55 deg. It carried a spherical cosmic ray detector designed by a group from Bristol University. A spherical aluminum vessel of diameter 75 cm contains a gas scintillation mixture and a thin spherical shell of Pilot 425 plastic, and forms a single optical cavity viewed by 16 photomultipliers. Particle tracks through the detector may be characterized by their impact parameter p and by whether or not they pass through the cup of plastic scintillator placed between the sphere and the spacecraft body (referred to below as the Anti-Coincidence Detector or ACD). Individual particle charges are determined by separately measuring the gas scintillation and the Cerenkov emission from the plastic shell. This is possible because of the quite different distribution in time of these emissions.

Fowler, P. H.↗

Imaging X-ray spectrophotometers

A new instrument which combines the good energy resolution of the gas scintillation proportional counter with the high position resolution of the microchannel plate is proposed. A study of the factors which determine the combined energy and position resolution of the new instrument is discussed. Submillimeter position resolution along with good energy resolution (8% fwhm at 6 keV) should be achievable.

Hailey, C. J.↗

Support of research in X-ray astronomy

Activities described include: (1) the evaluation of CCD detectors for X-ray astronomy applications; (2) contributions to the development of an imaging gas scintillation proportional counter; (3) the evaluation of certain metal oxide crystals as potential radiation detectors; (4) optical observations and searches for X-ray sources discovered by the HEAO-1 A2 experiment; and (5) theoretical modeling of nonequilibrium ionization structure of supernova remnants.

Garmire, G.↗

Detalied X-ray observations of the Cygnus Loop

High quality X-ray spectra and imaging observations of the Cygnus Loop have been obtained with three different instruments. The High Resolution Imager (HRI) on the Einstein Observatory was used to obtain arcsecond resolution images of select bright regions in the Cygnus Loop which permit detailed comparisons between the X-ray, optical, and radio structure of the Loop. The Imaging Proportional Counter (IPC) on the Einstein Observatory was used to obtain an arcminute resolution map of essentially the full Loop structure. Finally, an Imaging Gas Scintillation Proportional Counter (IGSPC), carried aloft by a sounding rocket last fall, obtained modest resolution, spatially resolved spectrophotometry of the Cygnus Loop. An X-ray map of the Loop in the energy of the O VIII line was obtained. These data combine to yield a very powerful probe of the abundance, temperature, and density distribution of material in the supernova remnant, and in the interstellar medium.

Ku, W. H.-M.↗

Imaging X-ray spectrophotometric observation of SN 1006

An imaging gas scintillation proportional counter (IGSPC) at the focal plane of a grazing incidence telescope was carried aloft by a sounding rocket and used to observe soft X-ray emission from the supernova remnant SN 1006. The instrument obtained the first unambiguous detection of strong (8 + or 0.0-2 photons/sq cm s) oxygen He-alpha and Ly-alpha emission at 0.59 + or - 0.02 keV from SN 1006. This line emission is consistent with emission from a 1.8 x 10 to the 6th K plasma, although hard X-ray emission from an additional power law or a higher temperature component was also observed. The X-ray emission may be interpreted as due to either (1) a combination of blast-wave and reverse shock assuming equilibrium ionization in the plasma or (2) blast-wave emission alone with a significant degree of ionization disequilibrium.

Vartanian, M. H.↗

Variation of the pulse profile of Hercules X-1

The X-ray pulsar Her X-1 was observed in an on-state during its 35th cycle of activity in May, 1983 using the gas scintillation proportional counter (GSPC) array of the Tenma X-ray astronomy satellite. The outstanding features observed during the declining phase of the on-state included: a sharp decrease in the main X-ray pulse amplitude; and a steady increase in the column density of cool matter. On the basis of the spectral shape of the pulses, it is suggested that the main phase was attenuated due to electron scattering of the X-ray beam in a highly ionized medium located 3 x 10 to the 8th cm from the neutron star. Near the end of the on-state, the main pulse totally disappeared and a plain sinusoidal profile was observed. The observed pulse profiles are reproduced in graphic form.

Ohashi, T.↗

Transient dips of Cygnus X-1 observed from Tenma

The transient intensity dips of the binary system Cyg X-1 have been observed, using the gas scintillation proportional counter (GSPC) array onboard the Tenma X-ray astronomy satellite. The duration of the dips was in the range from several seconds to 10 minutes, with several dips occurring as much as 15 h before the superior conjunction. Within the dips, complex structures were observed with time scales of several seconds, and, in at least one case, shorter than two seconds. For a dip lasting longer than 10 minutes, a high-quality spectrum was obtained which reveals the K-absorption edge of iron at 7.18 + or - 0.18 keV. On the basis of the observed absorption, it is suggested that the dips are caused by absorption due to relatively cool matter (less than about 30,000 k); the low-energy excess observed during the dips is due either to an extended soft X-ray emitting corona or to partial obscuration of the X-ray source by multiple blobs. From the time structure of the dip, a blob size of the order of 10 to the 9th cm is derived.

Kitamoto, S.↗

X-ray spectroscopy of the ultrasoft transient 4U 1543 - 47

The X-ray transient 4U 1543 - 47 was observed in August 1983 by the Exosat observatory near the maximum of an outburst. The X-ray spectrum was measured using a gas scintillation proportional counter (GSPC) and a transmission grating spectrometer (TGS). A broad (FWHM about 2.7 keV) line at 5.9 keV is detected in the GSPC, which is interpreted as a redshifted and broadened iron K-alpha line. The line broadening and redshift may arise from either Compton scattering in a cool plasma with small optical depth and/or from Droppler and relativistic effects in the vicinity of compact object. The spectrum below 2 keV, obtained with the TGS, shows evidence for a broad emission feature at 0.74 keV, which may be an iron L-transition complex. However, such an emission feature could be an artifact caused by an anomalously low interstellar absorption by neutral oxygen. The contimuum emission is extremely soft and is well described by an unsaturated Comptonized spectrum from very cool plasma (kT = 0.84 keV) with large scattering depth.

Van Der Woerd, H.↗

Exosat observations of Cygnus X-2 continuum and line spectrum

An analysis of five Exosat observations of Cyg X-2, taken around a full binary orbit is presented. The data were obtained using all instrumentation (1000 lines/mm Transmission Grating Spectrometer, Channel Multiplier Array + filters, Medium-Energy experiment, and Gas Scintillation Proportional Counter) simultaneously, and span the full energy range 0.5-20 keV. No clear evidence was found for a correlation of any of the source characteristics with orbital phase. During two of the observations, significant iron K emission at 6.7 keV was detected, the relative strength of which seems to correlate with total X-ray intensity during two sharp intensity dips. The previous detection of discrete emission features in the 12-19 A band with the Einstein grating is confirmed.

Chiappetti, L.↗

SIGHT - A balloon borne hard X-ray telescope

The authors report on progress toward developing a large-area, high-pressure xenon gas scintillator for use in hard X-ray astrophysics. Proof test results for a low-mass pressure vessel are presented. The design of a high-voltage multiplier board operating inside the scintillation chamber is discussed. The development of tetrakis-dimethylamine-thylene (TMAE)-based proportional tubes for detecting primary scintillation in the xenon is described. Finally, Monte Carlo tests of a scheme to use conventional photomultiplier tubes are discussed.

Wilkerson, J.↗

An instrument to measure the charge, and energy spectrum (20-1000 GeV/a) of the cosmic ray species oxygen to iron

BUGS-4 (Bristol University Gas Scintillator-4) made its maiden engineering flight from Fort Summer (NM) on the 29th of September 1993. The instrument was consumed by fire after striking a power line during landing following 24 hours at float. The analysis of the telemetered data from this sophisticated instrument is a demanding task. Early analysis was compromised by electronic artifacts. Unravelling these problems has been difficult and time consuming, especially as the flight hardware was burned beyond salvage, but is is an essential preliminary to analysis. During this report period we have concentrated on a small sub-set of data (the first 30,000 events; 90 minutes at float), and developed software algorithms to correct systematic errors. Using these corrected events we have begun to develop the analysis algorithms. Although the analysis is preliminary, and restricted to the first 30,000 events, the results are encouraging, and suggest the design concepts are well matched to this application. Further work will refine the analysis, and allow quantitative evaluation of the concepts employed in BUGS-4 for applicability to future instruments. We believe this work will justify fabrication of a new instrument employing techniques deployed on BUGS-4.

Gregory, J. C.↗