Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

First Results From the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14,2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employed five electron impact ion sources with available electron energies of either 70 or 25 eV. Three ion sources served as detectors for the GC columns and two were dedicated to direct atmosphere sampling and ACP gas sampling, respectively. The GCMS gas inlet was heated to prevent condensation, and served to evaporate surface constituents after impact.

Niemann, Hasso B.↗

Atmospheric measurements of carbonyl sulfide, dimethyl sulfide, and carbon disulfide using the electron capture sulfur detector

Measurements of atmospheric dimethyl sulfide (DMS), carbonyl sulfide (COS), and carbon disulfide (CS2) were conducted over the Atlantic Ocean on board the NASA Electra aircraft during the Chemical Instrumentation Test and Evaluation (CITE 3) project using the electron capture sulfur detector (ECD-S). The system employed cryogenic preconcentration of air samples, gas chromatographic separation, catalytic fluorination, and electron capture detection. Samples collected for DMS analysis were scrubbed of oxidants with NaOH impregnated glass fiber filters to preconcentration. The detection limits (DL) of the system for COS, DMS, and CS2 were 5, 5, and 2 ppt, respectively. COS concentrations ranged from 404 to 603 ppt with a mean of 489 ppt for measurements over the North Atlantic Ocean (31 deg N to 41 deg N), and from 395 to 437 ppt with a mean of 419 ppt for measurements over the Tropical Atlantic Ocean (11 deg S to 2 deg N). DMS concentrations in the lower marine boundary layer, below 600-m altitude, ranged from below DL to 150 ppt from flights over the North Atlantic, and from 9 to 104 ppt over the Tropical Atlantic. CS2 concentrations ranged from below DL to 29 ppt over the North Atlantic. Almost all CS2 measurements over the Tropical Atlantic were below DL.

Johnson, James E.↗

Multiple-ionization of xenon atoms by positron impact

Previously the cross sections were measured for positronium formation and single ionization by positron impact for He and H2. With the same apparatus, slightly modified, the single and multiple ionization of xenon is now investigated. The principle of the method is the detection of ion and positron in time correlation which allows the discrimination of positronium formation (whereby the positron vanishes) and the destinction of single, double and triple impact ionization (which lead to different ion flight times from the gas target to the ion detector). By using secondary electrons from the positron moderator, similar measurements were performed on electron impact ionization. By comparing with literature values for electron multiple ionization cross sections, the detection-probability ratios were determined for the differently charged ions.

Kruse, Georg↗

Definition phase study of the grand tour missions

The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.

Simpson, J. A.↗

Wave-particle interactions induced by SEPAC on Spacelab 1 Wave observations

Space experiments with particle accelerators (SEPAC) flew on Spacelab 1 in November and December 1983. SEPAC included an accelerator which emitted electrons into the ionospheric plasma with energies up to 5 keV and currents up to 300 mA. The SEPAC equipment also included an energetic plasma generator, a neutral gas generator, and an extensive array of diagnostics. The diagnostics included plasma wave detectors, and energetic electron analyzer, a photometer, a high sensitivity television camera, a Langmuir probe and a pressure gage. Twenty-eight experiments were performed during the mission to investigate beam-plasma interactions, electron beam dynamics, plasma beam propagation, and vehicle charging. The wave-particle interactions were monitored by the plasma wave instrumentation, by the energetic electron detector and by the optical detectors. All show evidence of wave-particle interactions, which are described in this paper.

Taylor, W. W. L.↗

Micromachined Electron-Tunneling Infrared Detectors

Pneumatic/thermal infrared detectors based partly on Golay-cell concept, but smaller and less fragile. Include containers filled with air or other gas trapped behind diaphragms. Infrared radiation heats sensors, causing gas to expand. Resulting deflections of diaphragms measured by displacement sensors based on principle of electron-tunneling transducers of scanning tunneling microscopes. Exceed sensitivity of all other miniature, uncooled infrared sensors presently available. Expected to include low consumption of power, broadband sensitivity, room-temperature operation, and invulnerability to ionizing radiation.

Kenny, Thomas W.↗

Fabrication and evaluation of large-area ultrasoft X-ray detectors suitable for spacecraft application

The modifications to the Houston/MSC design of the gas proportional counter flight electronics system are discussed. The following modifications are described: charge amplifier bandwidth improvements, power converter redesign, serial data output buffer, second differentiator, and risetime discriminator. In addition, the redesign of the stellar aspect camera is discussed along with developments in thin film fabrication.

Bowyer, S.↗

VETA-1 x ray detection system

The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.

Podgorski, W. A.↗

Application of reversal electron attachment for ultrasensitive detection of thermal electron-attaching molecules - CCl4 and C6H5O2

A standard gas-dilution method was used to determine the selective response of the reversal electron attachment detector to carbon tetrachloride concentrations in nitrogen. Data are provided that determine the lowest concentration of sample detectable with the present instrumental configuration as being below 1.0 part per trillion by volume. The incorporation of a 90-deg electrostatic deflector with the quadrupole mass spectrometer is shown to be vital, and with it, negative-ion quadrupole mass spectrometry is used to characterize the ionization process. Observations are also made of the reversal electron attachment response to nitrobenzene. The analytical potential of reversal electron capture negative-ion mass spectrometry is examined, and areas for future development are discussed.

Bernius, Mark T.↗

Rate and Gain Limitations of MSGC's and MGC's Combined with GEM and other Preamplification Structures

We have studied the rate and gain limits of diamond-coated Microstrip Gas Counters (MSGC's) and Micro-Gap Counters (MGC's) when combined with various preamplification structures: Gas Electron Multiplier (GEM), Parallel-Plate Avalanche Chamber (PPAC) or a MICROMEGAS-type structure. Measurements were done both with X rays and alpha particles with various detector geometries and in different gas mixtures at pressures from 0.05 to 10 atm. The results obtained varied significantly with detector design, gas mixture and pressure, but some general features can be identified. We found that in all cases, bare MSGC'S, MGC'S, PPAC's and MICROMEGAS, the maximum achievable gain drops with rate. The addition of preamplification structures significantly increases the gain of MSGC's and MGC'S, but this gain is still rate dependent. There would seem to be a general rate-dependent effect governing the usable gain of all these detectors. We speculate on possible mechanisms for this effect, and identify a safe, spark-free, operation zone for each system (detector + preamplification structure) in the rate-gain coordinate plane.

Fonte, P.↗

Ion tracking in an electrostatic potential distribution

An ion tracking system utilizing a single detector was designed to resolve two dimensional potential distributions in a vacuum. The ion detector consisted of a continuous dynode electron multiplier tube mounted behind a series of aperture plates. The detector was located on a track below a wedge shaped structure used to produce the desired potential distribution. A 150 volt electron beam aimed at selected regions, ionized the residual gas in the chamber. The ions were ejected from their source points by electrostatic forces causing them to drift downward toward the detector. Measurements of particle energy, detector position, and entry angle of the incoming particle flux were used to initialize a computer trajectory-tracing program. The program assumes a known theoretically calculated potential distribution near the wedge for computation of particle trajectories, providing a basis for evaluating the data. Special attention was given to characterization of the ion detector.

Ross, D. P.↗

GaAs CCD readout for engineered bandgap detectors

GaAs and related heterostructure charge-coupled devices (CCDs) for detector array readout multiplexer applications are described. Features of resistive-gate CCDs are compared with capacitive-gate CCDs for this application. Design examples of GaAs CCD readouts for linear and two-dimensional detector arrays with different detection methods and signal coupling schemes are described. Recent progress in two-dimensional electron gas (2DEG) Al(0.3)Ga(0.7)As/GaAs resistive-gate CCDs is also presented. The 2DEG resistive-gate CCD conventional buried-channel GaAs CCD.

Song, J.-I.↗

The development of a high energy cosmic ray detector for Spacelab-2

A large cosmic ray detector aimed at measurements of the energy spectra and of the elemental abundances of cosmic ray nuclei at very high energies, up to several TeV/nucleon was constructed. The instrument is an electronic counter telescope with a geometric factor of 5 sq ster. It accomplishes measurements of the particle energies through the use of gas Cerenkov counters and of transition radiation detectors. The solutions of a number of technological problems that are encountered when developing such instrumentation for Shuttle missions are discussed.

Lheureux, J.↗

Properties of the Flight Model Gas Electron Multiplier for the GEMS Mission

We present the gain properties of the gas electron multiplier (GEM) foil in pure dimethyl ether (DME) at 190 Torr. The GEM is one of the micro pattern gas detectors and it is adopted as a key part of the X-ray polarimeter for the GEMS mission. The X-ray polarimeter is a time projection chamber operating in pure DME gas at 190 Torr. We describe experimental results of (1) the maximum gain the GEM can achieve without any discharges, (2) the linearity of the energy scale for the GEM operation, and (3) the two-dimensional gain variation of the active area. First, our experiment with 6.4 keV X-ray irradiation of the whole GEM area demonstrates that the maximum effective gain is 2 x 10(exp 4) with the applied voltage of 580 V. Second, the measured energy scale is linear among three energies of 4.5, 6.4, and 8.0 keV. Third, the two-dimensional gain mapping test derives the standard deviation of the gain variability of 7% across the active area.

gas electron multiplier (GEM)↗

Variations of the cosmic ray general component in Antarctica

A cosmic ray variations, zonal cosmic ray modulation, was found in the lower atmosphere from the sonde measurement results. The variations give rise to anomalies in the latitude distributions of the cosmic ray charged component and the anomalous north-south asymmetry. To find the nature of the variations, the cosmic ray general component was measured with the same detectors as in the sonde measurements gas discharge counters and the counter telescopes with 7-mm Al filters detecting the electrons of energy above 200 keV and 5 MeV. The measurement data obtained in Antarctica in the years 1978 to 1983 are presented and discussed.

Charakhchyan, T. N.↗