Engineering PapersSearch

SEARCH · Engineering Papers

Results for “gas detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nano Sensors for Gas Detection in Space and Ground Support Applications

Personnel living in a space environment as well as technicians and engineers preparing spacecraft for launch can potentially be exposed to small amounts of hazardous gases. It is therefore important to be able to detect, identify and quantify the presence of a gas especially when its presence could lead to a fatal situation. The use of small and sensitive sensors can allow for the placement of these devices over a large area, thus allowing for a more precise and timely determination of a gas leak. ASRC Aerospace and its research partners are developing nano sensors for detection of various gases, including but not limited to: H2, NH3, N2O4, hydrazine and others. Initial laboratory testing has demonstrated the capability to detect the gases in concentrations lower than parts per million. Testing and development is continuing to improve the response and recovery times, to increase the sensitivity of the devices. Different coatings and electrodes are currently being evaluated to determine the optimum configuration of a variety of gases. The small footprint of the Nano sensors allows for several devices, each responsive in a different way to different gases, to be placed into a single substrate. Multiple devices embedded into a single substrate results in increased reliability and in a decrease for periodic calibrations. The use of different coatings will result in a small electronic nose capable of distinguishing between different gases. A multi-channel signal conditioner amplifier built on a small multi chip module is used to process the output of the sensors and to deliver a signal that can be remotely monitored. All the data is digitized and transmitted over the same cable pair used to power the amplifier. Multiple outputs can be connected to a single cable pair in order to minimize the added weight and expense associated with cabling in a spacecraft. The sensors will be run through a qualification process to evaluate their suitability for space applications we are expecting to have fully functional sensors available for initial field deployment and testing by the end of the year 2006.

Medelius, Pedro J.

BOS Gas Detection Pipeline (Integrated System for Optical Hydrogen Detection Using Background Oriented Schlieren and Machine Learning) [SWR-26-007]

This software is the world's first integrated background oriented schlieren and machine learning-based leak detection system. The system provides real time visualization of gas leaks and machine learning interpenetration of leak severity. The software is supplemented by SWR-25-177, "gpu_piv (Graphics Processing Unit Accelerated Background Oriented Schlieren Algorithm", also developed by the National Laboratory of the Rockies. SEE DOECODE ID 182832.

Palin, Ian [National Laboratory of the Rockies (NL

Heterodyne method for high specificity gas detection.

This paper describes a new technique for measuring trace quantities of gases. The technique involves the use of a reference cell (containing a known amount of the gas being sought) and a sample cell (containing an unknown amount of the same gas) wherein the gas densities are modulated. Light passing through the two cells in sequence is modulated in intensity at the vibrational-rotational lines characteristic of the absorption spectrum for the gas of interest. Since the absorption process is nonlinear, modulating the two absorption cells at two different frequencies gives rise to a heterodyning effect, which in turn introduces sum and difference frequencies in the detected signal. Measuring the ratio of the difference frequency signal for example, to the signal introduced by the reference cell provides a normalized measure of the amount of the gas in the sample cell. The readings produced are thereby independent of source intensity, window transparency, and detector sensitivity. Experimental evaluation of the technique suggests that it should be applicable to a wide range of gases, that it should be able to reject spurious signals due to unwanted gases, and that it should be sensitive to concentrations of the order of 10 to the minus 8th power when used with a sample cell of only 20 cm length.

Dimeff, J.

SIM PlanetQuest Key Project Precursor Observations to Detect Gas Giant Planets Around Young Stars

We present a review of precursor observing programs for the SIM PlanetQuest Key project devoted to detecting Jupiter mass planets around young stars. In order to ensure that the stars in the sample are free of various sources of astrometric noise that might impede the detection of planets, we have initiated programs to collect photometry, high contrast images, interferometric data and radial velocities for stars in both the Northern and Southern hemispheres. We have completed a high contrast imaging survey of target stars in Taurus and the Pleiades and found no definitive common proper motion companions within one arcsecond (140 AU) of the SIM targets. Our radial velocity surveys have shown that many of the target stars in Sco-Cen are fast rotators and a few stars in Taurus and the Pleiades may have sub-stellar companions. Interferometric data of a few stars in Taurus show no signs of stellar or sub-stellar companions with separations of <5 mas. The photometric survey suggests that approximately half of the stars initially selected for this program are variable to a degree (1(sigma) >0.1 mag) that would degrade the astrometric accuracy achievable for that star. While the precursor programs are still a work in progress, we provide a comprehensive list of all targets ranked according to their viability as a result of the observations taken to date. By far, the observable that removes the most targets from the SIM-YSO program is photometric variability.

astrophysics

Laser system for natural gas detection. Phase 1: Laboratory feasibility studies

This project demonstrated the feasibility of using laser remote sensing technology as a tool for leak survey work in natural gas distribution systems. A laboratory device was assembled using a pair of helium neon (HeNe) lasers to measure methane. One HeNe laser emits radiation at a wavelength of 3.3922 micrometers, which corresponds to a strong absorption feature of methane, while the other emits radiation at a wavelength of 3.3911 micrometers, which corresponds to a weak absorption by methane. As a particular area is scanned for leaks, the laser is pointed at convenient topographic targets within its operating range, about 25 m. A portion of the backscattered radiation is collected by a receiver and focused onto an indium antimonide (InSb) photodetector, cooled to 77K. Methane concentrations were determined from the differential absorption at the two wavelengths for the backscattered radiation.

Grant, W. B.

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter

Development of trace gas detection instrumentation

Breadboard hardware was constructed to demonstrate detection of a gaseous species by the heterodyne principle. The characteristics of the component parts were investigated and preliminary measurements were made to establish the sensitivity and selectivity of the method for gas analysis of CO, CO2, and N2O. A prototype heterodyne gas analyzer was designed, built, and brought into operational condition. Performance parameters of the prototype analyzer were investigated and its sensitivity to CO2 measured. Further development was undertaken for both the optical bench and the electronic processor components. A three-gas prototype analyzer, capable of measuring the gases CO, CO2, and CH4 was also constructed and tested. Detailed descriptions of the work and results are presented.

Source record

He-Ne and CW CO2 laser long-path systems for gas detection

This paper describes the design and testing of a laboratory prototype dual He-Ne laser system for the detection of methane leaks from underground pipelines and solid-waste landfill sites using differential absorption of radiation backscattered from topographic targets. A laboratory-prototype dual CW carbon dioxide laser system also using topographic backscatter is discussed, and measurement results for methanol are given. With both systems, it was observed that the time-varying differential absorption signal was useful in indicating the presence of a gas coming from a nearby source. Limitations to measurement sensitivity, especially the role of speckle and atmospheric turbulence, are described. The speckle results for hard targets are contrasted with those from atmospheric aerosols. The appendix gives appropriate laser lines and values of absorption coefficients for the hydrazine fuel gases.

Grant, W. B.

Silicon Carbide-Based Hydrogen and Hydrocarbon Gas Detection

Hydrogen and hydrocarbon detection in aeronautical applications is important for reasons of safety and emissions control. The use of silicon carbide as a semiconductor in a metal-semiconductor or metal-insulator-semiconductor structure opens opportunities to measure hydrogen and hydrocarbons in high temperature environments beyond the capabilities of silicon-based devices. The purpose of this paper is to explore the response and stability of Pd-SiC Schottky diodes as gas sensors in the temperature range from 100 to 400 C. The effect of heat treating on the diode properties as measured at 100 C is explored. Subsequent operation at 400 C demonstrates the diodes' sensitivity to hydrogen and hydrocarbons. It is concluded that the Pd-SiC Schottky diode has potential as a hydrogen and hydrocarbon sensor over a wide range of temperatures but further studies are necessary to determine the diodes' long term stability.

Hunter, Gary W.

Semiconducting polymers for gas detection

Conjugated polyenes, and polyesters containing phthalocyanine in their backbone, were synthesized. These polymers were characterized by chemical analysis, thermogravimetric analysis, spectral analysis, and X-ray diffraction studies for crystallinity, as well as for their film-forming capability and gas/polymer interactions. Most of the polymers were relatively insensitive to water vapor up to 50 percent relative humidity, but the polyester/phthalocyanine (iron) polymer was relatively insensitive up to 100 percent RH. On the other hand, poly(p-dimethylaminophenylacetylene) was too conductive at 100 percent RH. Of the gases tested, the only ones that gave any evidence of interacting with the polymers were SO2, NOx, HCN and NH3. Poly(imidazole)/thiophene responded to each of these gases at all relative humidities, while the other polymers gave varying response, depending upon the RH. Thus, since most of these gases were electron-accepting, the electron-donating character of poly(imidazole)/thiophene substantiates the concept of electronegativity being the operating principle for interaction effects. Of the six polymers prepared, poly(imidazole)/thiophene first showed a very good response to smoldering cotton, but it later became nonresponsive; presumably due to oxidation effects.

Byrd, N. R.

Detecting gas leaks in propellant lines

Leak detector consisting of inflatable bladder and flow-measurement equipment, localizes leaks and allows determination of leak rates past individual components. Fail-safe system prevents overpressurized bladder.

Escue, W. T.

Multiple-Diode-Laser Gas-Detection Spectrometer

Small concentrations of selected gases measured automatically. Proposed multiple-laser-diode spectrometer part of system for measuring automatically concentrations of selected gases at part-per-billion level. Array of laser/photodetector pairs measure infrared absorption spectrum of atmosphere along probing laser beams. Adaptable to terrestrial uses as monitoring pollution or control of industrial processes.

Webster, Christopher R.

A Hazardous Gas Detection System for Aerospace and Commercial Applications

The detection of explosive conditions in aerospace propulsion applications is important for safety and economic reasons. Microfabricated hydrogen, oxygen, and hydrocarbon sensors as well as the accompanying hardware and software are being, developed for a range of aerospace safety applications. The development of these sensors is being done using MEMS (Micro ElectroMechanical Systems) based technology and SiC-based semiconductor technology. The hardware and software allows control and interrocation of each sensor head and reduces accompanying cabling through multiplexing. These systems are being, applied on the X-33 and on an upcoming STS-95 Shuttle mission. A number of commercial applications are also being pursued. It is concluded that this MEMS-based technology has significant potential to reduce costs and increase safety in a variety of aerospace applications.

Hunter, G. W.

A Hazardous Gas Detection System for Aerospace and Commercial Applications

The detection of explosive conditions in aerospace propulsion applications is important for safety and economic reasons. Microfabricated hydrogen, oxygen, and hydrocarbon sensors as well as the accompanying hardware and software are being developed for a range of aerospace safety applications. The development of these sensors is being done using MEMS (Micro ElectroMechanical Systems) based technology and SiC-based semiconductor technology. The hardware and software allows control and interrogation of each sensor head and reduces accompanying cabling through multiplexing. These systems are being applied on the X-33 and on an upcoming STS-95 Shuttle mission. A number of commercial applications are also being pursued. It is concluded that this MEMS-based technology has significant potential to reduce costs and increase safety in a variety of aerospace applications.

Hunter, G. W.

Mid-infrared difference-frequency generation source pumped by 1.1-1.5 micrometer dual-wavelength fiber amplifier for trace-gas detection

Continuous-wave mid-infrared radiation near 3.5 micrometers is generated by difference-frequency mixing of the output of a compact 1.1-1.5 micrometer dual-wavelength fiber amplifier in periodically poled LiNbO3. The diode side-pumped amplifier is constructed with double-cladding Yb-doped fiber followed by single-mode Er/Yb codoped fiber. Output powers of as much as 11 microW at 3.4 micrometers are obtained, and spectroscopic detection of CH4 and H2CO is demonstrated. c 1998 Optical Society of America.

Non-NASA Center

Portable fiber-coupled diode-laser-based sensor for multiple trace gas detection

Tunable narrowband mid-infrared radiation from 3.25 to 4.4 micrometers is generated by a compact fiber-coupled, difference-frequency-based spectroscopic source. A 20-mW external cavity diode laser (with a tuning range from 814 to 870 nm) and a 50-mW distributed-Bragg-reflector diode-laser-seeded ytterbium-doped fiber amplifier operating at 1083 nm are difference-frequency mixed in a multi-grating, temperature-controlled periodically poled LiNbO3 crystal. A conversion efficiency of 0.44 mW/(W2cm) (corresponding to a power of approximately equal to 3 microW at 3.3 micrometers) represents the highest conversion efficiency reported for a portable device. Performance characteristics of such a sensor and its application to spectroscopic detection of CO2, N2O, H2CO, HCl, NO2, and CH4 will be reported in this work.

Non-NASA Center