Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “galvanic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Liquid Galvanic Coatings for Protection of Imbedded Metals

Coating compositions and methods of their use are described herein for the reduction of corrosion in imbedded metal structures. The coatings are applied as liquids to an external surface of a substrate in which the metal structures are imbedded. The coatings are subsequently allowed to dry. The liquid applied coatings provide galvanic protection to the imbedded metal structures. Continued protection can be maintained with periodic reapplication of the coating compositions, as necessary, to maintain electrical continuity. Because the coatings may be applied using methods similar to standard paints, and because the coatings are applied to external surfaces of the substrates in which the metal structures are imbedded, the corresponding corrosion protection may be easily maintained. The coating compositions are particularly useful in the protection of metal-reinforced concrete.

MacDowell, Louis G.↗

The Feasibility of Using a Galvanic Cell Array for Corrosion Detection and Solution Monitoring

An initial investigation into the response of the individual galvanic couples was conducted using potentiodynamic polarization measurements of solutions under conditions of varying corrosivity. It is hypothesized that the differing electrodes may provide a means to further investigate the corrosive nature of the analyte through genetic algorithms and pattern recognition techniques. The robust design of the electrochemical sensor makes its utilization in space exploration particularly attractive. Since the electrodes are fired on a ceramic substrate at 900 C, they may be one of the most rugged sensors available for the anticipated usage.

Kolody, Mark↗

Influence of Electrotactile Tongue Feedback on Controlling Upright Stance during Rotational and/or Translational Sway-referencing with Galvanic Vestibular Stimulation

Integration of multi-sensory inputs to detect tilts relative to gravity is critical for sensorimotor control of upright orientation. Displaying body orientation using electrotactile feedback to the tongue has been developed by Bach-y-Rita and colleagues as a sensory aid to maintain upright stance with impaired vestibular feedback. MacDougall et al. (2006) recently demonstrated that unpredictably varying Galvanic vestibular stimulation (GVS) significantly increased anterior-posterior (AP) sway during rotational sway referencing with eyes closed. The purpose of this study was to assess the influence of electrotactile feedback on postural control performance with pseudorandom binaural bipolar GVS. Postural equilibrium was measured with a computerized hydraulic platform in 10 healthy adults (6M, 4F, 24-65 y). Tactile feedback (TF) of pitch and roll body orientation was derived from a two-axis linear accelerometer mounted on a torso belt and displayed on a 144-point electrotactile array held against the anterior dorsal tongue (BrainPort, Wicab, Inc., Middleton, WI). Subjects were trained to use TF by voluntarily swaying to draw figures on their tongue, both with and without GVS. Subjects were required to keep the intraoral display in their mouths on all trials, including those that did not provide TF. Subjects performed 24 randomized trials (20 s duration with eyes closed) including four support surface conditions (fixed, rotational sway-referenced, translating the support surface proportional to AP sway, and combined rotational-translational sway-referencing), each repeated twice with and without GVS, and with combined GVS and TF. Postural performance was assessed using deviations from upright (peak-to-peak and RMS sway) and convergence toward stability limits (time and distance to base of support boundaries). Postural stability was impaired with GVS in all platform conditions, with larger decrements in performance during trials with rotation sway-referencing. Electrotactile feedback improved performance with GVS toward non-GVS levels, again with the greatest improvement during trials with rotation sway-referencing. These results demonstrate the effectiveness of tongue electrotactile feedback in providing sensory substitution to maintain postural stability with distorted vestibular input.

Wood, Scott J.↗

Passive Resonant Bidirectional Converter with Galvanic Barrier

A passive resonant bidirectional converter system that transports energy across a galvanic barrier includes a converter using at least first and second converter sections, each section including a pair of transfer terminals, a center tapped winding; a chopper circuit interconnected between the center tapped winding and one of the transfer terminals; an inductance feed winding interconnected between the other of the transfer terminals and the center tap and a resonant tank circuit including at least the inductance of the center tap winding and the parasitic capacitance of the chopper circuit for operating the converter section at resonance; the center tapped windings of the first and second converter sections being disposed on a first common winding core and the inductance feed windings of the first and second converter sections being disposed on a second common winding core for automatically synchronizing the resonant oscillation of the first and second converter sections and transferring energy between the converter sections until the voltage across the pairs of transfer terminals achieves the turns ratio of the center tapped windings.

Rosenblad, Nathan S.↗

Evaluation of Galvanic Vestibular Stimulation System

Microgravity exposure results in an adaptive central reinterpretation of information from multiple sensory sources to produce a sensorimotor state appropriate for motor actions in this unique environment, but this new adaptive state is no longer appropriate for the 1-g gravitational environment on Earth. During these gravitational transitions, astronauts experience deficits in both perceptual and motor functions including impaired postural control, disruption in spatial orientation, impaired control of locomotion that include alterations in muscle activation variability, modified lower limb kinematics, alterations in head-trunk coordination as well as reduced dynamic visual acuity. Post-flight changes in postural and locomotor control might have adverse consequences if a rapid egress was required following a long-duration mission, where support personnel may not be available to aid crewmembers. The act of emergency egress includes, but is not limited to standing, walking, climbing a ladder, jumping down, monitoring displays, actuating discrete controls, operating auxiliary equipment, and communicating with Mission Control and recovery teams while maintaining spatial orientation, mobility and postural stability in order to escape safely. The average time to recover impaired postural control and functional mobility to preflight levels of performance has been shown to be approximately two weeks after long-duration spaceflight. The postflight alterations are due in part to central reinterpretation of vestibular information caused by exposure to microgravity. In this study we will use a commonly used technique of transcutaneous electrical stimulation applied across the vestibular end organs (galvanic vestibular stimulation, GVS) to disrupt vestibular function as a simulation of post-flight disturbances. The goal of this project is an engineering human-in-the-loop evaluation of a device that can degrade performance of functional tasks (e.g. to maintain upright balance) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

Kofman, I. S.↗

Preliminary Results Using Galvanic Vestibular Reduction as a Non-Pharmaceutical Tool for Motion Sickness Mitigation

Alterations in vestibular sensory processing following G-transitions lead to motion sickness and spatial disorientation upon return to Earth’s gravity. The use of non-pharmaceutical mitigation for motion sickness has several potential advantages over drug treatment options. The purpose of this study was to validate a non-pharmaceutical tool using galvanic vestibular reduction (GVR) to mitigate G-transitional induced motion sickness and spatial disorientation.

G N Pradhan↗

Preliminary Results Using Galvanic Vestibular Reduction as a Non-Pharmaceutical Tool for Motion Sickness Mitigation

Introduction: Alterations in vestibular sensory processing following G-transitions lead to motion sickness and spatial disorientation upon return to Earth’s gravity. The use of non-pharmaceutical mitigation for motion sickness has several potential advantages over drug treatment options. The purpose of this study was to validate a non-pharmaceutical tool using galvanic vestibular reduction (GVR) to mitigate G-transitional induced motion sickness and spatial disorientation. Methods: Using a repeated measures counter-balanced design, motion sickness and perception are obtained during Coriolis cross-coupling stimuli on a rotating chair across three GVR treatment interventions: throughout stimulus testing (prevention), following symptom onset (rescue), and placebo control. Subjects perform up to 10 sets of pitch head movements during constant rotation. For each set, head movement is cued every 10 seconds, alternating between pitch forward (chin resting to chest) and pitch backward (head upright) for a total of 7 forward and backward movements. During each head movement, subjects are asked to use a joystick to record the magnitude of their perceived rotation along all three axes. During the 2-minute pause between sets, motion sickness symptom scoring was obtained using the Pensacola Diagnostic Index and subject discomfort (0-20) ratings. Performance on a sensorimotor and cognitive test battery is measured during a fourth session to map changes in GVR level with functional performance. Results: Fifteen of 30 subjects have completed testing to date. Preliminary findings suggest GVR may be more effective in reducing symptoms in subjects who self-report less susceptibility on a pre-test motion sickness susceptibility questionnaire. Based on the joystick measures, GVR significantly reduces both the magnitude (mean 22% - 34%) and duration (mean 42% - 49%) of perceived roll and pitch sensation with head movements during constant rotation. It is important to note that comparable levels of GVR (up to 2.5mA) does not impair performance on a functional test battery including mobility and balance tasks. Discussion: Our preliminary findings suggest GVR may be useful in reducing disorienting roll and pitch illusions associated with Coriolis cross-coupling stimuli. While transfer to post-flight treatment will need to be validated, the potential advantages of our non-pharmaceutical countermeasure approach would be to provide rapid therapeutic effect while allowing continuous titration of GVR amplitude during recovery to maintain operational performance.

Gaurav Pradhan↗

Galvanic Vestibular Reduction Modifies Perception of Coriolis Cross-Coupling and Delays Motion Sickness Onset

INTRODUCTION: Alterations in vestibular sensory processing following G-transitions lead to head movement sensitivity and motion sickness upon return to Earth’s gravity. The purpose of this study was to evaluate whether a non-pharmaceutical tool using galvanic vestibular reduction (GVR) could suppress disorienting illusions and mitigate motion sickness. A similar approach using anodal (inhibitory) currents delivered to both ears has been shown to result in a selective reversible ablation of irregular vestibular afferents [1]. METHODS: Using a repeated measures counter-balanced design, motion sickness and perception were obtained in 26 subjects during Coriolis cross-coupling stimuli on a rotating chair across three GVR treatment interventions: throughout stimulus testing (prevention), following symptom onset (rescue), and placebo control. The GVR peak current was maintained at 2.5 mA across subjects and across prevention / rescue sessions. Subjects performed up to 10 sets of pitch head movements during constant rotation. For each set, head movement was cued every 10 seconds, alternating between pitch forward (chin resting to chest) and pitch backward (head upright) for a total of 7 forward and backward movements. During each head movement, subjects were asked to use a joystick to record the magnitude of their perceived rotation along three axes. During the 2-minute pause between sets, motion sickness symptom scoring was obtained using the Pensacola Diagnostic Index and subject discomfort (0-20) ratings. Performance on a sensorimotor and cognitive test battery was measured during a fourth session to map changes in GVR level with functional performance. RESULTS: Fourteen of the 26 subjects were not susceptible to the motion stressor (i.e., did not reach an endpoint in the control condition). While the time to endpoint, or number of head movements, did not significantly vary across the three GVR conditions in the remaining subjects, the symptom levels were significantly lower through the third set of head movements when GVR was on throughout the testing. Initiating GVR following symptom onset did not appear to alter the symptom progression nor time to motion sickness endpoint. Based on the joystick measures, GVR significantly modified the perceived roll and pitch sensation during head movements, reducing the amplitude of tilt in most subjects. It is important to note that comparable levels of GVR did not impair performance on a functional test battery including mobility, balance and cognitive tasks. DISCUSSION: Our findings suggest GVR may be useful in reducing disorienting roll and pitch illusions and delaying the onset of motion sickness. Further enhancements will be required to individualize the stimulation amplitude and optimize the waveform delivery. Adapting this non-pharmaceutical countermeasure approach to allow self-administered titration of current amplitude during recovery would enable transfer to post-flight treatment of motion sickness. [1] Minor L. B. and Goldberg J. M. (1991) J Neurosci 11, 1636-48. 109, 889-894.

G N Pradhan↗

Study of crevice-galvanic corrosion of aluminum

Corrosion effects of aluminum-copper and aluminum-nickel couples in oxygenated distilled water, and aluminum alloys in oxygenated copper sulfate solution were studied. One of each of the couples had a water tight seal, and showed no substantial corrosion, and of the unsealed couples, only the aluminum-copper developed corrosion.

Draley, J. E.↗

Studying Biological Rhythms of Person's Skin-galvanic Reaction and Dynamics of Light Transmission by Isomeric Substance in Space Flight Conditions

Intensity and amplitude of human functional systems and human most important organs are wavelike, rhythmic by nature. These waves have constant periodicity, phase and amplitude. The mentioned characteristics can vary, however their variations have a pronounced reiteration in the course of time. This indicates a hashing of several wave processes and their interference. Stochastic changes in wave processes characteristics of a human organism are explained either by 'pulsations' associated with hashing (superposition) of several wave processes and their interference, or by single influence of environmental physical factors on a human organism. Human beings have respectively periods of higher and lower efficiency, state of health and so on, depending not only of environmental factors, but also of 'internal' rhythmic factor. Sometimes peaks and falls periodicity of some or other characteristics is broken. Disturbance of steady-state biological rhythms is usually accompanied by reduction of activity steadiness of the most important systems of a human organism. In its turn this has an effect on organism's adaptation to changing living conditions as well as on general condition and efficiency of a human being. The latter factor is very important for space medicine. Biological rhythmology is a special branch of biology and medicine, it studies rhythmic activity mechanisms of organs, their systems, individuals and species. Appropriate researches were also carried out in space medicine.

Glushko, Vladimir↗

Salt Spray Test to Determine Galvanic Corrosion Levels of Electroless Nickel Connectors Mounted on an Aluminum Bracket

During preliminary vehicle design reviews, requests were made to change flight termination systems from an electroless nickel (EN) connector coating to a zinc-nickel (ZN) plating. The reason for these changes was due to a new NASA-STD-6012 corrosion requirement where connectors must meet the performance requirement of 168 hr of exposure to salt spray. The specification for class F connectors, MIL-DTL-38999, certifies the EN coating will meet a 48-hr salt spray test, whereas the ZN is certified to meet a 168-hr salt spray test. The ZN finish is a concern because Marshall Space Flight Center has no flight experience with ZN-finished connectors, and MSFC-STD-3012 indicates that zinc and zinc alloys should not be used. The purpose of this test was to run a 168-hr salt spray test to verify the electrical and mechanical integrity of the EN connectors and officially document the results. The salt spray test was conducted per ASTM B117 on several MIL-DTL-38999 flight-like connectors mounted to an aluminum 6061-T6 bracket that was alodined. The configuration, mounting techniques, electrical checks, and materials used were typical of flight and ground support equipment.

Rolin, T. D.↗

Galvanic Protected Anode Materials for Molten Regolith Electrolysis

This effort aimed to explore the use of refractory alloys as long-lifetime electrode materials for use in a molten regolith electrolysis (MRE) reactor, a technology that can produce oxygen (O2) from regolith. To find a material capable of withstanding the high temperatures and corrosive nature of molten regolith, first-principles thermodynamic calculations were performed on platinum group metals in the presence of iron (Fe) and silicon (Si) to determine favorable compositions for resisting unwanted secondary phases that could form on the surface of the material. As a result of these first-principles calculations, the kinetic properties of elements such as aluminum (Al), Fe, and Si can be more easily derived, which would provide insight into the longevity of such a material when used in an MRE reactor. The effort funded by this CIF project mapped the entire phase diagram of platinum group metals, which is beneficial not only to MRE where high temperatures and molten material are present, but also aerospace applications like turbine materials, terrestrial metal processing techniques, and energy storage applications. This project narrowed a broad spectrum of refractory metals down to a small list of alloys that would be able to survive not only the high temperatures of an MRE reactor, but also the thermodynamic forces that would cause inferior alloys to form secondary phases, which would ultimately consume the electrodes of the reactor. This research needs to be followed up with experimental demonstrations of these alloys in an MRE environment.

Kevin Grossman↗