A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A rare gas optics-free absolute photon flux and energy analyzer for solar and planetary observations

We have developed a prototype spectrometer for space applications requiring long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

Inflight Radiometric Calibration of New Horizons' Multispectral Visible Imaging Camera (MVIC)

We discuss two semi-independent calibration techniques used to determine the inflight radiometric calibration for the New Horizons Multi-spectral Visible Imaging Camera (MVIC). The first calibration technique compares the measured number of counts (DN) observed from a number of well calibrated stars to those predicted using the component-level calibration. The ratio of these values provides a multiplicative factor that allows a conversation between the preflight calibration to the more accurate inflight one, for each detector. The second calibration technique is a channel-wise relative radiometric calibration for MVIC's blue, near-infrared and methane color channels using Hubble and New Horizons observations of Charon and scaling from the red channel stellar calibration. Both calibration techniques produce very similar results (better than 7% agreement), providing strong validation for the techniques used. Since the stellar calibration described here can be performed without a color target in the field of view and covers all of MVIC's detectors, this calibration was used to provide the radiometric keyword values delivered by the New Horizons project to the Planetary Data System (PDS). These keyword values allow each observation to be converted from counts to physical units; a description of how these keyword values were generated is included. Finally, mitigation techniques adopted for the gain drift observed in the near-infrared detector and one of the panchromatic framing cameras are also discussed.

Howett, C. J. A.↗

RADIATION DETECTION CHALLENGES

Pacific Northwest National Laboratory (PNNL) is a key part in the international community in the detection of radioxenon. PNNL’s design of radioxenon detection systems have resulted in the need for multiple sources to be capable of producing high quality NaI and CsI well detectors. Testing of NaI and CsI detectors from multiple manufactures has resulted in the discovery of two issues. First, there is potential for a dead layer, due to the manufacturer handling of the crystal, to be present on both the CsI and NaI crystals. The second issue is an energy drift caused by incorrect mating of PMT and PMT base to the crystal. These two issues cause adverse effects on the measurement of radioxenon or any other radiological measurement. It is clear that additional handling and inspection procedures are necessary during the manufacturing process. This paper will discuss the matter in more detail and give evidence of the presence of these issues in PNNL purchased crystals. The paper will also propose procedures for handling and testing to high quality CsI and NaI crystals get delivered on future purchases.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Amplifier drift tester

Automatic measurement of gain and zero drift characteristics of dc amplifier

TEST EQUIPMENT↗

Amplifier drift tester

Automatic measuring and recording of gain and zero drift characteristics of electronic amplifier

Cree, D.↗

Strong Laser Field Fragmentation of H{sub 2}: Coulomb Explosion without Double Ionization

We observe fragmentation of H{sub 2} molecules exposed to strong laser fields into excited neutral atoms. The measured excited neutral fragment spectrum resembles the ionic fragmentation spectrum including peaks due to bond softening and Coulomb explosion. To explain the occurrence of excited neutral fragments and their high kinetic energy, we argue that the recently investigated phenomenon of frustrated tunnel ionization is also at work in the neutralization of H{sup +} ions into excited H* atoms. In this process the tunneled electron does not gain enough drift energy from the laser field to escape the Coulomb potential and is recaptured. Calculation of classical trajectories as well as a correlated detection measurement of neutral excited H* and H{sup +} ions support the mechanism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-201-04: Evaluation of Elekta Agility MLC Performance Using Statistical Process Control

Purpose: to evaluate the performance and stability of the Elekta Agility MLC model using an automated quality control (QC) test in combination with statistical process control tools. Methods: Leaf positions were collected daily for 11 Elekta units over 5–19 months using the automated QC test, which analyzes 23 MV images to determine the location of MLC leaves relative to the radiation isocenter. The leaf positions are measured at 5 nominal positions, and images are acquired at collimator 0° and 180° to capture all MLC leaves in the field-of-view. Leaf positioning accuracy was assessed using individual and moving range control charts. Control limits were recomputed following MLC recalibration (occurred 1–2 times for 4 units). Specification levels of ±0.5, ±1 and ±1.5mm were tested. The mean and range of duration between out-of-control and out-of-specification events were determined. Results: Leaf position varied little over time, as confirmed by very tight individual control limits (mean ±0.19mm, range 0.09–0.44). Mean leaf position error was −0.03mm (range −0.89–0.83). Due to sporadic out-of-control events, the mean in-control duration was 3.3 days (range 1–23). Data stayed within ±1mm specification for 205 days on average (range 3–372) and within ±1.5mm for the entire date range. Measurements stayed within ±0.5mm for 1 day on average (range 0–17); however, our MLC leaves were not calibrated to this level of accuracy. Conclusion: The Elekta Agility MLC model was found to perform with high stability, as evidenced by the tight control limits. The in-specification durations support the current recommendation of monthly MLC QC tests with a ±1mm tolerance. Future work is on-going to determine if Agility performance can be optimized further using high-frequency QC test results to drive recalibration frequency. Factors that can affect leaf positioning accuracy, including beam spot motion, leaf gain calibration, drifting leaves, and image artifacts, are under investigation.

60 APPLIED LIFE SCIENCES↗

AI Applications to Physics Experiments at Jefferson Lab

We survey how AI/ML is being deployed across Jefferson Lab's experimental and accelerator programs. In EPSCI, Hydra applies computer vision to automate real-time data-quality monitoring across all four experimental halls, replacing manual inspection of hundreds to thousands of histograms per shift. AIEC (AI Experiment Controls) uses ML to stabilize drift chamber gains and is now part of standard CEBAF production running, while AI Optimized Polarization (AIOP) targets autonomous control of polarized targets and photon beam angular alignment. In CASA, cavity fault classification models identify faulted cavities and trip types from waveform data with ~85% and ~78% agreement to labeled data, respectively, and are deployed in production; a separate effort applies LLMs and hybrid search to make the CEBAF operations logbook AI-ready. QCD-focused work includes transformer- and GAN-based generative models for particle-level event simulation, with distributed GAN training scaling studies on Polaris. Additional efforts span ML-on-FPGA for the EIC and a new Data Science Department coordinating anomaly detection, uncertainty quantification, and HPC-scalable ML lab-wide. Collectively, these projects illustrate AI's growing role in improving efficiency across JLab's nuclear physics mission.

Mei, Xinxin [Thomas Jefferson National Accelerator↗

Low cost instrumentation amplifier

Amplifier can be used for many applications requiring high input impedance and common mode rejection, low drift, and gain accuracy on order of one percent. Performance of inexpensive amplifier approaches that of some commercial instrumentation amplifiers in many specifications.

Sturman, J. C.↗

The NASA OBPG 2020 On-Orbit Calibration of SNPP VIIRS for Ocean Color Applications

The NASA Ocean Biology Processing Group (OBPG) has continued monitoring the SNPP VIIRS on-orbit calibration for bands M1-M11 over its mission to optimize the calibration for ocean color applications. The OBPG has recently implemented several changes to the calibration scheme: using solar-derived f-factors to detrend the lunar observations; using long-term exponentials of time as basis vectors (along with libration angles) for radiometric fits to any resulting lunar temporal drifts; deriving gain adjustments to the solar f-factors from these exponentials; and deriving gain adjustments due to modulated RSRs outside of the solar/lunar calibration using TOA reference spectra. These calibration changes minimize the impact of uncertainties in any one component of the calibration on the derived f-factors. The final f-factors incorporate VIIRS solar diffuser measurements, h-factor BRDF corrections, lunar-derived gains, and modulated RSR gains. The combined BRDF corrections, lunar gain adjustments, and mRSR gain adjustments define effective h-factors for each band. The improvements in the on-orbit calibration are validated by evaluation of globally-derived anomaly plots of remote sensing reflectance for the ocean color bands. The ultimate goal of the OBPG calibration effort is incorporation of a consistent SNPP VIIRS ocean color data set into the NASA multi-mission ocean color climate data record.

VIIRS↗

UHECR acceleration in dark matter filaments of cosmological structure formation

A mechanism for proton acceleration to ∼ 10{sup 21} eV is suggested. It may operate in accretion flows onto thin dark matter filaments of cosmic structure formation. The flow compresses the ambient magnetic field to strongly increase and align it with the filament. Particles begin the acceleration by E × B drift with the accretion flow. The energy gain in the drift regime is limited by the conservation of the adiabatic invariant p{sub p}erpendicular{sup 2}/B(r). Upon approaching the filament, the drift turns into the gyro-motion around the filament so that the particle moves parallel to the azimuthal electric field. In this 'betatron' regime the acceleration speeds up to rapidly reach the electrodynamic limit cp{sub max} = eBR for an accelerator with magnetic field B and the orbit radius R (Larmor radius). The periodic orbit becomes unstable and the particle slings out of the filament to the region of a weak (uncompressed) magnetic field, which terminates the acceleration. To escape the filament, accelerated particles must have gyro-radii comparable with the filament radius. Therefore, the mechanism requires pre-acceleration that is likely to occur in large scale shocks upstream or nearby the filament accretion flow. Previous studies identify such shocks as efficient proton accelerators, with a firm upper limit ∼ 10{sup 19.5} eV placed by the catastrophic photo-pion losses. The present mechanism combines explosive energy gain in its final (betatron) phase with prompt particle release from the region of strong magnetic field. It is this combination that allows protons to overcome both the photo-pion and the synchrotron-Compton losses and therefore attain energy ∼ 10{sup 21} eV. A customary requirement on accelerator power to reach a given E{sub max}, which is placed by the accelerator energy dissipation ∝E{sub max}{sup 2}/Z{sub 0} due to the finite vacuum impedance Z{sub 0}, is circumvented by the cyclic operation of the accelerator.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of WFIRST Coronagraph Broadband Contrast Performance to DM Actuator Errors

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory (JPL), we have investigated the sensitivity of a Hybrid Lyot Coronagraph (HLC) broadband contrast performance to DM actuator errors and actuator limits. Considered case include drifts in actuator gains or actuator response curves, paired actuators, as well as the limits imposed by a neighboring-actuator rule. Actual data about the actuator drifts and the knowledge about the paired-actuators obtained in several DM characterization experiments conducted at JPL, as well as the neighboring-actuator rule implemented on the OMC testbed were used in simulations. We obtained good agreement between the model prediction and the testbed measurement in terms of static HLC contrast floor and contrast chromaticity.

Sidick, Erkin↗

Method of calibrating an interferometer and reducing its systematic noise

Methods of operation and data analysis for an interferometer so as to eliminate the errors contributed by non-responsive or unstable pixels, interpixel gain variations that drift over time, and spurious noise that would otherwise degrade the operation of the interferometer are disclosed. The methods provide for either online or post-processing calibration. The methods apply prescribed reversible transformations that exploit the physical properties of interferograms obtained from said interferometer to derive a calibration reference signal for subsequent treatment of said interferograms for interpixel gain variations. A self-consistent approach for treating bad pixels is incorporated into the methods.

Hammer, Philip D.↗

Development of Resistive Electrode Gas Electron Multiplier (RE-GEM)

We successfully produced Resistive-Electrode Gas Electron Multiplier (RE-GEM) which has resistive electrodes instead of the metal ones which are employed for the standard GEM foils. RE-GEM has a resistive electrode of 25 micron-thick and an insulator layer of 100 micron-thick. The hole structure of RE-GEM is a single conical with the wider and narrower hole diameters of 80 micron and 60 micron, respectively. A hole pitch of RE-GEM is 140 micron. We obtained the maximum gain of about 600 and the typical energy resolution of about 20% (FWHM) at an applied voltage between the resistive electrodes of 620 V, using a collimated 8 keV X-rays from a generator in a gas mixture of 70% Ar and 30% CO2 by volume at the atmospheric pressure. We measured the effective gain as a function of the electric field of the drift region and obtained the maximum gain at an drift field of 0.5 kV/cm.

detectors↗

Probing the proton exchange kinetics of BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3− δ ceramic electrolyte by operando diffuse reflectance infrared Fourier transform spectroscopy

Proton exchange kinetics plays an important role in governing the performance of intermediate-temperature protonic ceramic electrolysis cells (PCECs) for hydrogen production. Our understanding of the nature of the surface hydration reaction at the single-cell level, however, remains very limited, hampering further efficiency improvements. Here, in this study, we developed a custom operando diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) platform that operates under high temperature and steam conditions with applied bias. Quantitative investigations of surface H 2 O/D 2 O isotope exchange in a BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3−δ (BZCYYb1711) protonic electrolyte-based single cell were conducted under different applied voltages using this DRIFTS platform, to gain molecular-level insight into hydration kinetics. The findings show that the application of an external voltage significantly enhances the surface proton exchange rate, decreasing the apparent activation energy from 29.1 kJ mol −1 at open-circuit voltage (OCV) to 6.8 kJ mol −1 at 1.3 V. In addition, distinct voltage-induced spectral shifts in O–D vibrations point to dynamic changes in surface hydration. These findings demonstrate a sensitive spectroscopic platform for probing interfacial proton processes and reveal strong electrochemical control over surface proton kinetics, offering new opportunities for probing electrolyte hydration behavior in PCECs.

36 - MATERIALS SCIENCE↗